Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Similar documents
D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

CHAPTER 8 PARAMETER SUMMARY

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

SX (400V) System configuration

SX (400 V) System configuration

SX (690 V) System configuration

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

Manual Overview...1 2

Inverter Drive /Vector Drive Motors & Controls

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

FD423-EA-000 EtherCAT Servo Drive

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

vacon nxs robust drive for heavy use

VF-nC1 Adjustable Speed Drive Engineering Specification

This Chapter contains:

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

PowerFlex 400 AC Drive Guide Specification

S11 Adjustable Speed Drive Engineering Specification

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

ACH550 HVAC Drive Submittal

KNC-SRV-FD423 Series Servo Driver

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

PowerFlex 400 Submittal

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

General Specifications FECA-TE /2010. Phone: Fax: Web:

ADJUSTABLE SPEED DRIVES. AS1 Drive

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ADJUSTABLE SPEED DRIVES FS1

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

TOSVERT TM VF-nC3 Parameter List

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

E3 Adjustable Speed Drive Engineering Specification

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

Preface WARNING. CAUTION! Heat sink may heat up over 70 o C (158 o F), during the operation. Do not touch the heat sink.

CHAPTER 3 WIRING DANGER

Emotron FDU 2.0 Variable Speed Drive

GS1 Parameter Summary Detailed Parameter Listings...4 9

Emotron FDU 2.0 Variable Speed Drive

Product description. At a glance. Customer benefits

RSi SG Series Sensorless Vector Variable Frequency Drive

General Purpose Drives

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Operation Instructions NORDAC SK 400E. Frequency Inverter. SK 400E B / SK 400E B (0.4kW / 0.7kW, 1~ 115V)

FUJI Inverter. Standard Specifications

NX series Constant and variable torque Variable Speed Drives for induction motors

PLC-K506 Series FEATURES DESCRIPTION FEATURES

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

FE0 9

Fan and Pump AC Inverter

Design Characteristics. FlexDrive II. Series

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

VFD-EL Series User Manual

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

EFC 3600 Frequency converter for higher energy efficiency and improved process control

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

Dynamic drives for low power AC motors

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

Preface PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

A510 INVERTER. 230VClas3~ kW 1-3HP HP kW 1-425HP. 460VClas3~ 575/690VClas3~ 1-270HP INSTRUCTIONMANUAL

MH300 Series / MS300 Series

WJ200 series Pursuing the Ideal Compact Inverter

VarioTrane TR1. Series 2800 TR1-PRC002-E4

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

Inverter MICROMASTER 410

E L (0) / FAX:+31(0)

NX Series Inverters. HVAC Pocket Programming Guide

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive.

VFD-EL Series User Manual

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

B850 Boiler House Energy Monitor

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

High on efficiency big on reliability AC Drive for Fans & Pumps

Why choose Danfoss? VLT Technical data Dimensions Ordering

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

Specifications of ASDA A2-E_220V Series

Phoenix DX Clean Power (18 Pulse) AC Drive

VFS11 Parameter List for up to CPU version 105

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Transcription:

Type number key VFD 007 E 43 A Version number A=standard P=Cold Plate (Frame A only) T= (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC VFD-E series Power 007=0.75kW 022=2.2kW 055=5.5kW 110=11kW etc Delta Variable Frequency Drive Option Keypad KPE-LE02 230V single phase 0.2 ~ 2.2kW Type number VFD 002E21A 004E21A 007E21A 015E21A 022E21A Rated power kw 0.2 0.4 0.75 1.5 2.2 Rated output current A RMS 1.6 2.5 4.2 7.5 11 Rated output capacity kva 0.6 1 1.6 2.9 4.2 Rated input current (1-phase/3-phase) A RMS 4.9/1.9 6.5/2.7 9.7/5.1 15.7/9 24/15 Mains fuse (for UL: Bussmann) JJN-10 JJN-15 JJN-20 JJN-30 JJN-50 Dimensions HxWxD mm 142x72x152 174x100x152 Size **** A B Weight kg 1.1 1.2 Section of power cables mm 2 2 ~ 3 0.8 ~ 8 Cooling Convection Fan Recommended brake resistor Ω/W 250/200 ** 150/200 ** 85/300 60/450 Minimum brake resistor value Ω 200 ** 100 ** 80 ** 40 ** With external BUE20015 brake chopper **** See dimensional drawing on Page 7. DELTA ELECTRONICS, INC. 1 Delta reserves the right to make Datasheet VFD-E Version11 May2011.doc

400V 0.4 ~ 2.2kW Type number VFD 004E43A 007E43A 015E43A 022E43A Rated power kw 0.4 0.75 1.5 2.2 Rated output current A RMS 1.5 2.5 4.2 5.5 Rated output capacity kva 1.2 2 3.3 4.4 Rated input current A RMS 1.9 3.2 4.3 7.1 Mains fuse (for UL: Bussmann) JJS-6 JJS-10 JJS-15 Dimensions HxWxD mm 142x72x152 174x100x152 Size **** A B Weight kg 1.1 1.9 Section of power cables mm 2 2 ~ 3 0.8 ~ 8 Cooling Convection Fan Recommended brake resistor Ω/W 400/300 ** 300/400 ** 200/600 Minimum brake resistor value Ω 400 ** 200 ** 160 ** 140 ** With external BUE40015 brake chopper **** See dimensional drawing on Page 7. 400V 3.7 ~ 11kW Type number VFD 037E43A 055E43A 075E43A 110E43A Rated power kw 3.7 5.5 7.5 11 Rated output current A RMS 8.5 13 18 24 Rated output capacity kva 6.5 9.9 13.7 18.3 Rated input current A RMS 11.2 14 19 25 Mains fuse (for UL: Bussmann) JJS-20 JJS-30 JJS-40 JJS-50 Dimensions HxWxD mm 174x100x152 260x130x169.2 Size **** B C Weight kg 1.9 3.5 4.2 Section of power cables, stranded (with ring) mm 2 0.8 ~ 8 1 ~ 8 Cooling Fan Recommended brake resistor Ω/W 140/750 96/1100 69/1500 53/2000 Minimum brake resistor value Ω 96 69 53 **** See dimensional drawing on Page 7. DELTA ELECTRONICS, INC. 2 Delta reserves the right to make

400V 15 ~ 22kW Type number VFD 150E43A 185E43A 220E43A Rated power kw 15 18.5 22 Rated output current A RMS 32 38 45 Rated output capacity kva 24 29 34 Rated input current A RMS 35 41 49 Mains fuse (for UL: Bussmann) JJN-70 JJN-80 JJN-100 Dimensions HxWxD mm 310x190x200 Size **** D Weight kg 7.5 Section of power cables mm 2 2 ~ 21 Cooling Fan Recommended brake resistor Ω/W 31/4800 Minimum brake resistor value Ω 31 **** See dimensional drawing on Page 7. DELTA ELECTRONICS, INC. 3 Delta reserves the right to make

230V single phase 0.2 ~ 0.75kW Cold Plate Type number VFD 002E21P 004E21P 007E21P Rated power kw 0.2 0.4 0.75 Rated output current A RMS 1.6 2.5 4.2 Rated output capacity kva 0.6 1 1.6 Rated input current (1-phase/3-phase) A RMS 4.9/1.9 6.5/2.7 9.7/5.1 Mains fuse (for UL: Bussmann) JJN-10 JJN-15 JJN-20 Dimensions HxWxD mm 155x72x111.5 Size **** EP1 Weight kg 1.1 Section of power cables mm 2 2 ~ 3 Cooling Cold Plate Recommended brake resistor Ω/W 250/200 ** 150/200 ** Minimum brake resistor value Ω 200 ** 100 ** 80 ** ** With external BUE20015 brake chopper. **** See dimensional drawing on Page 6. 400V 0.4 ~ 0.75kW Cold Plate Type number VFD 004E43P 007E43P 015E43P Rated power kw 0.4 0.75 1.5 Rated output current A RMS 1.5 2.5 4.2 Rated output capacity kva 1.2 2 3.3 Rated input current A RMS 1.9 3.2 4.3 Mains fuse (for UL: Bussmann) JJS-6 JJS-10 Dimensions HxWxD mm 155x72x111.5 Size **** EP1 Weight kg 1.1 Section of power cables mm 2 2 ~ 3 Cooling Cold plate Recommended brake resistor Ω/W 400/300 ** 300/400 ** Minimum brake resistor value Ω 400 ** 200 ** 160 ** ** With external BUE40015 brake chopper. **** See dimensional drawing on Page 6. DELTA ELECTRONICS, INC. 4 Delta reserves the right to make

230V single phase 0.2 ~ 0.75kW built-in Type number VFD 002E21T 004E21T 007E21T Rated power kw 0.2 0.4 0.75 Rated output current A RMS 1.6 2.5 4.2 Rated output capacity kva 0.6 1 1.6 Rated input current (1-phase/3-phase) * A RMS 4.9/1.9 6.5/2.7 9.7/5.1 Mains fuse (for UL: Bussmann) JJN-10 JJN-15 JJN-20 Dimensions HxWxD mm 142x72x152 Size **** A Weight kg 1.1 Section of power cables mm 2 2 ~ 3 Cooling Convection Recommended brake resistor Ω/W 250/200 150/200 Minimum brake resistor value Ω 200 100 80 * Single-phase drives can also be connected to 230V 3-phase. **** See dimensional drawing on Page 6. 400V 0.4 ~ 1.5kW built-in Type number VFD 004E43T 007E43T 015E43T Rated power kw 0.4 0.75 1.5 Rated output current A RMS 1.5 2.5 4.2 Rated output capacity kva 1.2 2 3.3 Rated input current A RMS 1.9 3.2 4.3 Mains fuse (for UL: Bussmann) JJS-6 JJS-10 Dimensions HxWxD mm 142x72x152 Size **** A Weight kg 1.1 1.9 Section of power cables mm 2 2 ~ 3 0.8 ~ 8 Cooling Convection Fan Recommended brake resistor Ω/W 400/300 300/400 Minimum brake resistor value Ω 400 200 160 **** See dimensional drawing on Page 6. DELTA ELECTRONICS, INC. 5 Delta reserves the right to make

Common data VFD-E Mains voltage range V 200V: 180 ~ 264 400V: 342 ~ 528 Mains frequency Hz 47 ~ 63 Output frequency range Hz 0 ~ 600 Output voltage range V 0 ~ Mains Operating temperature C -10 ~ +50 * Storage temperature C -20 ~ +60 Atmospheric pressure kpa 86 ~ 106 Relative humidity % 90 (non condensing) Vibration <20Hz: 1g / 20~50Hz: 0.6g Degree of protection IP20 Pollution degree 2 Altitude m 1000 Keypad Option (detachable) Max. Signal cable section mm 2 0.2 ~ 1 ** SINK or SOURCE Range Digital inputs 6x MIx Scan time Pull-up (internal) Via jumper 24VDC 2~40ms 4kΩ (5.5mA) Analogue inputs Accuracy 10 bits 1x AVI Range 0~10VDC Impedance 47kΩ 1x ACI Range 4~20mA or 0~10VDC (AVI2***) Impedance 250Ω 47kΩ Digital outputs 1x MOx Optocoupler OC 48VDC/50mA Analogue outputs Accuracy 1x AFM Range Impedance 8 bits 0~10VDC/2mA 470Ω Relays 1x Change-over NO: R A ~R C NC: R B ~R C Signal supply 1x +24VDC/20mA Potentiometer supply 1x +10VDC/3mA Trip memory Last 5 errors Acc/Dec Times s 0.01 ~ 600s Modbus RS485 Baudrate Serial communication 1x RJ45 Address Mode * Side-by-side mounting 10 ~ +40 C ** For standard relay 0.2 ~ 3mm 2 *** Select via switch ACI/AVI ASCII Modbus RTU Resistive 5A/240VAC-24VDC Inductive 1.5A/240VAC-24VDC Resistive 3A/240VAC-24VDC Inductive 0.5A/240VAC-24VDC 4800 ~ 38400 1 ~ 254 7N2/7E1/7O1/7N1/7E2/7O2 8N2/8E1/8O1/8N1/8E2/8O2 DELTA ELECTRONICS, INC. 6 Delta reserves the right to make

Sizes and dimensions in mm [inches] Size A Size B Size C Size D DELTA ELECTRONICS, INC. 7 Delta reserves the right to make

Size EP1 DELTA ELECTRONICS, INC. 8 Delta reserves the right to make

Keypad option 71.9 [2.83] 25.9 [1.02] 42.4 [1.67] 16.3 [0.64] 8.6 [0.34] 52.4 [2.06] M3*0.5(2X) Basic wiring diagram 34.3 [1.35] 61.0 [2.40] 1.5 [0.06] 8.1 [0.32] Power terminals (general) Terminal symbol Terminal function R/L1, S/L2, T/L3 Mains input * U/T1, V/T2, W/T3 Motor output +2(/B1) ~ B2 Brake resistor (external option) +2(/B1) ~ - Brake unit (BUE series) (external option) Ground * Use R/L1 and S/L2 terminals for single phase connection. Built-in brake chopper type Options Filters : 2 nd Environment, C3, motor cable 15m, carrier frequency 8kHz Frame A 230V 1-phase: 1 st Environment, C2, motor cable 1m carrier frequency 8kHz Braking Brake resistors and Brake units. Keypad&Cables PU06 Copy Keypad and Extension cables for cabinet door mounting. Mounting I/O cards Encoder cards DIN-rail and Earthing plate. Digital I/O card with 3 Inputs and 3 Outputs Relay cards: 2 relays with NO/NC contacts or 3 relays with NO contacts Analogue I/O: 2 Inputs (12 bit) and 2 Outputs (12 bit) EME-PG01 (Ext. power supply required) for closed-loop speed control. Communication USB card CME-USB01, Communication converters, Splitters, Cables. Fieldbus Software Option cards: Devicenet, Profibus, LonWorks, CApen. To read, save, copy, change parameters, download VFDSoft. For PLC programming download WPL2.12. Both can be downloaded from www.delta.com.tw [Products] [Industrial Automation] [Drive]. Select any drive series and go to Download. DELTA ELECTRONICS, INC. 9 Delta reserves the right to make

Programming Group 00-xx Group 01-xx Group 02-xx Group 03-xx Group 04-xx Group 05-xx Group 06-xx Group 07-xx Group 08-xx Group 09-xx Group 10-xx Group 11-xx Group 12-xx Group 13-xx PLC-mode User Parameters Drive ID, Software version, Password, Control Mode, User-defined display, etc. Basic Parameters V/f-curve, Acc/Dec times, Jogging, S-curve, etc. Operation Method Parameters Source of frequency/operation, Carrier frequency, 2-3 Wire operation, Motor direction inhibit, Stop method, etc. Output Function Parameters Function and setting of analogue and digital outputs and relay, Count values, Fan control, Brake control, etc. Input Function Parameters Function and setting of analogue and digital inputs, Index function, Debounce time, Digital input status, etc. Multi-step Speed and PLC-Parameters 15 Speed steps with time duration for PLC function, Frequency cycling. Protection Parameters Protection settings, Fault memory, etc. Motor Parameters Setting of motor parameters, Auto-tuning, PTC-function. Special Parameters DC-Braking, 3 Skip frequencies, Speed search, AVR, Auto energy saving, Auto reset, Braking level, etc. Communication Parameters Protocol, Address, Transmission speed, etc. PID Control Parameters PID settings, Sleep and Wake-up, etc. Digital I/O Parameters for Option Cards Digital inputs, Digital outputs, Relays. Analogue I/O Parameters for Option Cards Analogue inputs, Analogue outputs. Encoder Parameters for Option Encoder Card Input, Pulse number, Feedback error treatment, PID values, Filter, etc. PLC functionality via Editor on PC: Disable, Run, Edit, Read/Write in VFD-E 45 Commands (28 basic, 17 application) 6 Input and 2 Output contacts 32 points 500 steps www.delta.com.tw DELTA ELECTRONICS, INC. 10 Delta reserves the right to make