DITCH WITCH LOCATORS

Similar documents
S u b s i t e L o c at o r s

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Obsolete Document. Dynatel

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

UTILITY LOCATING EQUIPMENT

UAT-600 Series. amprobe.com

Leica DIGISYSTEM TM Safe and fast location of underground services

Leica Digisystem Safe and fast location of underground services

Leica Digicat i-series Safe and fast location of underground services

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

cable and pipe locators RD Utility cable and pipe locator

F I S H E R R E S E A R C H L A B O R A T O R Y

SeekTech SR-60 SeekTech SR-20 NaviTrack Scout

TRIAD SERIES 2310 SC

TW-82 TW-82 ACCESSORIES. Operating Manual Revision Level 1 DIGITAL LINE TRACER

TW-82. Operating Manual DIGITAL LINE TRACER. Revision Level 1

TW-82 DIGITAL LINE TRACER. Operating Manual

A higher performance product designed for safer excavating.

TW-82P DIGITAL LINE TRACER WITH PASSIVE POWER DETECTION. Operating Manual

AT-5000 Professional Underground Cable / Pipe Locator System

900R/T Series. Operator s Manual. Issue CMW

Utility cable and pipe locator

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Leica Digisystem i-series Safe and fast location of underground utilities

Easy Locator HDR. Terraplus Inc. 52 West Beaver Cr. Rd. #12, Richmond Hill, ON. Canada L4B 1L9. Utility Locating System

The new CXL2 and DXL2 Cable Avoidance Tools and SGA2 and SGV2 Signal Generators from C.Scope have been designed to set a new benchmark in excavating

Dynatel 2250E/2273E Advanced Cable and Fault Locator

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

Pipeline Current Mapper

RD1000 Ground Probing Radar

TW Operating Manual F I S H E R R E S E A R C H L A B O R A T O R Y. Digital Line Tracer

Report. Mearns Consulting LLC. Former Gas Station 237 E. Las Tunas Drive San Gabriel, California Project # E

pipeline integrity PCM + Pipeline Current Mapper

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Armada Technologies Pro800D Hi-Power Wire and Valve Locator. Operating Instructions

Get To The Point. Faster!

Quick Start Guide AT-6000 Advanced Wire Tracer Series

AT-7000 Advanced Wire Tracer

9800 XT. Utility Line Locator OPERATIONS MANUAL SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION. Page 1 of 45

spy pig Tracking systems

STAFF User Manual. Manual Part #

EZi & ULTRA SYSTEMS. Cable Tracing and Locating EZi & ULTRA Sytems

RD8100 OPTIMUM PRECISION FOR DAMAGE PREVENTION

Universal precision cable and pipe locator

Dynatel Locating and Marking System

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

3M Dynatel Locating and Marking System

spy pig Tracking systems

User Manual 8880 Series Fault Finding & Locating Kit

User Manual Pathfinder Precision Locating System

Locate Plastic. Pipe &Conduit. 3M Infrastructure Protection Division

Products. Locating DAMAGE PREVENTION

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Fault Mapper Cable Length Meter & Fault Locator Alphanumeric TDR Model CA7024

vscan Data Sheet V1.0

Locate Plastic. Pipe &Conduit. 3M Electrical Markets Division

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

Electronic Pipeline Technology

Insulation Testers and Earth Ground Testers

Universal precision cable and pipe locator

RD5100 Series. Precision water industry pipe and cable locator kits

MIT415 Insulation tester

Table of Contents - 2 -

vloc Series 2 Smaller and lighter Over four times battery life Define, set and lock available features Customizable startup screen and much more...

3M Dynatel Locating and Marking Products

MG2 Series. Corrosion Thickness Gages. MG2, MG2-XT, and MG2-DL. MG2-xt and MG2-DL are. B-scan and optional Live A-scan with Waveform Adjust

3M Dynatel. Locating and Marking System. Quickly & Accurately. Identify Underground. Assets

Easy to use, single frequency. pipe and cable locator

use, more powerful, delivers cleaner data with more detail and up to 20% better penetration depth than comparable systems.

Utility cable and pipe locator

3M Dynatel Cable/Pipe/Fault Locator 2550/2573 Series

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

8873 v3 Pathfinder Locator User Manual

The future of installation testing is here. The 1650 Series Multifunction Testers

IC-F7000. Advanced selective call and ALE make HF communication easier than ever!

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

Schonstedt Magnetic Locators

TRANSACTION RECORD TR

Advanced instrumentation solutions crafted with highest precision

Agilent EPM Series Power Meters

TraceMaster. Pipe and Cable Locator Multi-Frequency Receiver and Radio Linked to Transmitter. Instruction Manual

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

DUNHAM & MORROW By Schonstedt Instrument Company Tel: Fax:

APPA 300 Series. The Most User-Friendly High Performance Multimeter

Ca b l e Tr a c i n g a n d L o c a t i n g EZi & ULTRA Sytems

PV210. Why buy the PV210?

C.A.T and Genny User Guide. Revision

Version 1.0 English. EziSYSTEM User Manual

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Transcription:

DITCH WITCH LOCATORS

YOUR WINDOW TO THE UNDERGROUND.

DITCH WITCH 950R/T and 970T Pipe and Cable Locator System Like real estate, underground construction is all about location, location, location. The three modes and 20+ frequencies of the 950R help you quickly locate buried telephone, CATV, power, gas and water lines. In active mode, the 950T and 970T transmit via direct line connection, induction clamp or induced broadcast signals. In passive mode, the 950R detects signals generated by 31 khz (CATV) and 50/60 Hz power, as well as re-radiated radio frequencies. And in beacon mode, the 950R detects signals from optional beacons to locate non-metallic service lines; with the 512 Beacon, the 950R locates cast-iron pipe.

KEY FEATURES DETAILS Simultaneous 8 and 29 khz transmission means an alternate signal is available if one is hard to detect; 80 khz frequency is helpful in locating old tracer wires or pipes with insulators where low frequencies do not work well. Enhanced backlit LCD offers optimal visibility in low-light conditions. 950T and 970T s rugged case and sealed keypad withstand tough weather conditions and provide superior moisture resistance. Patented digital signal processing (DSP) offers more effective locating and reduces interference; stable DSP depth readings do not vary with temperature or time, as analog readings do. Lightweight 950R receiver is balanced for easy handling. The 970T s 5-watt output is the most productive in our line and in its class. 970T transmits all 950T frequencies plus an optional 200-kHz frequency for more difficult locates. 970T has 80 hours of battery life, the longest in its class. 970T is equipped with built-in circuit protection, reverse battery protection, and live wire hookup protection for reliability.

DITCH WITCH 910R Pipe and Cable Locator The 910R is an easy-to-use, affordable pipe- and cable-locating receiver that s made to order. Select the frequencies that best suit the application locating pipe, cable, or non-directional beacons simplify operation, and pay only for the frequencies you need. DETAILS KEY FEATURES Built on the same platform as the highly productive 950R, the 910R comes standard with up to four frequencies, while additional frequencies may be added for a small fee (over 20 to choose from). Active frequencies can be transmitted by 950T or 970T transmitters. Passive frequencies are used in sweeps or in the location of buried power and CATV lines. Simplified controls help novice users quickly become proficient. Durable and reliable, the 910R features circuit breakers, leftright arrows, and 50 hours of battery life.

DITCH WITCH 300SR/ST Pipe and Cable Locator System The 300SR/ST system is one of the most simple to use, efficient and cost-effective methods for locating and avoiding buried telephone, CATV, power, gas, and water lines. Consisting of a passive or active 300SR receiver and 300ST transmitter, this simple, lightweight system features multiple antennas, intuitive controls, an easy-to-read backlit display, and depth estimation up to 15 feet (4.6 m). Whether you use it passively or actively, the 300SR/ST helps you get a handle on any situation. KEY FEATURES DETAILS Transmitter s dual-power output levels help save battery life when the application requires low-level output. Rugged design and moistureresistant cases stand up to longterm use and tough weather conditions. The 300SR is the only unit in its class with standard backlighting. Ergonomically balanced design means greater comfort and reduced fatigue to the operator. Operates on six standard C-cell batteries. System helps to verify location of underground facility in order to help avoid damage due to excavation. At-a-glance controls are arranged for simple, balanced operation.

DITCH WITCH 150R/T Cable Avoidance System The 150R/T is an easy, affordable way to see what obstacles lie beneath the surface of your next jobsite. So you can dig a posthole or footing, install a French drain, or lay fiber-optic cable with confidence. Weighing just over 5 lb (2.3 kg), the lightweight, compact 150R/T is just as easy to carry as it is to operate. DETAILS KEY FEATURES Color-coded components make the 150R/T system easy to buy just pick your frequency at the time of purchase. Optional beacons help you trace water, sewer, or drain lines with ease. Both the 150R receiver and the 150T transmitter operate using consumer C-cell alkaline batteries. System helps to verify location of underground facility in order to help avoid damage due to excavation. Every 150R/T locating system is backed by superior quality service and support, all available from a worldwide network of Ditch Witch dealers. With only four buttons and an easy-to-read display, the 150R receiver is simple to operate. All locating information is at your fingertips. Rugged, water-resistant housings stand up to extreme jobsite conditions. System comes complete with a convenient carrying bag.

DITCH WITCH Electronic Marker Locator (EML) Say goodbye to your identity problem. The Ditch Witch EML accessory virtually eliminates the search for buried facilities when properly marked with 3M ScotchMark Electronic Markers. When buried with the facility, these markers serve as signaling devices. Each marker is color-coded to APWA standards and produces an industry-specific frequency that is pinpointed by the Ditch Witch 910R or 950R locator and EML. KEY FEATURES DETAILS Easy to use: the EML transmits a signal to the buried marker, and the marker returns a signal to the EML; location of the marker is indicated by an audible tone from the locator. Electronic Markers can be buried over key facilities such as valve boxes, splices, service stubs, and cable paths during construction or at the time of maintenance. Marker s passive antenna requires no internal power source. Water-resistant polyethylene shells withstand minerals, chemicals, and underground temperature extremes. Metallic conductors, fences, AC power lines or other utility electronic markers will not affect the locating process.

DITCH WITCH 2150GR Ground Penetrating Radar For municipalities, contractors, utilities, subsurface utility engineers, and other companies with significant infrastructure and outdated utility maps, the Ditch Witch 2150GR helps put everything in proper perspective. It can detect both metallic and non-metallic pipes and cables to depths of up to 19 feet (6 m), depending on soil conditions and antenna selection. And with 5.6 mph (9 km/h) survey speed four times faster than that of competitive models and digitally controlled radar, the 2150GR provides faster, clearer images.

KEY FEATURES DETAILS 2150GR provides an accurate survey whether the operator is pushing or pulling it across any surface. User-friendly software enables the operator to manually input landmarks such as water hydrants and sewer drains, for more accurate survey maps. Earth-engaged antenna provides better contact on uneven terrain and reduces signal loss. Data recording and storage capabilities provide on-site data review, post-collection analysis, and proof of work when jobs require it. Multiple frequencies allow the operator to customize the unit for the job conditions. Auto-calibrating gain and filter take the guesswork out of setup. Folds for easy transport in a standard car trunk.

DITCH WITCH AF2/FT14 Fault Locator System The sophisticated and extremely accurate AF2 A-frame detector and FT14 fault transmitter system locates secondary faults in direct-buried, unshielded cables to within inches at streetlight circuits and meter risers; across driveways, sidewalks, and streets; and even under snow or frozen ground. The FT14 places high-voltage, pulsed DC signals on target lines, breaking down corrosive buildup in the process; the AF2 then probes the ground to locate leakages and pinpoint faults. KEY FEATURES DETAILS Unique system that serves a variety of industries, including power and communications utility companies, general contractors, and subsurface utility engineering contractors. Ruggedly built; designed to withstand heavy use in a wide variety of conditions. Corresponding transmitter pulse, sound, and indicator light; and faster settle time. Easy-to-understand analog meter display indicates the direction of the fault and shows when detector is located directly above the fault. FT14 s fault indicator helps the operator determine the presence of a fault (break, short, etc.). AF2 detector comes with a remote probe for working around obstacles. Both units operate on ordinary alkaline batteries.

SPECIFICATIONS 950R Receiver DIMENSIONS U.S. METRIC HEIGHT 27.75 IN 705 MM LENGTH 12.8 IN 325 MM WIDTH 5.9 IN 145 MM OPERATING WEIGHT 4.5 LB 2 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C ANTENNA CONFIGURATIONS SINGLE PEAK, TWIN PEAK, NULL, LEFT/RIGHT (LINE ONLY) AUDIO OUTPUT SPEAKER DEPTH ESTIMATE TOLERANCES* ACTIVE LINE ± 3% 0.2-5 FT 0.06-1.5 M ACTIVE LINE ± 5% 5-10 FT 1.5-3 M ACTIVE LINE ± 10% 10 FT AND DEEPER 3 M AND DEEPER PASSIVE LINE ± 10% 0.5-10 FT 1.5-3 M BEACON ± 5% 0.5-10 FT 1.5-3 M LCD BACKLIGHT LED (GREEN) EXTERNAL PORTS RS-232 SERIAL BATTERIES TYPE BATTERY LIFE BATTERY SAVER 6 C-CELL ALKALINE APPROXIMATELY 50 HOURS (CONTINUOUS USE AT 70 F / 21 C) UNIT SHUTS OFF AFTER 5 MINUTES OF INACTIVITY OPERATIONAL FREQUENCIES PASSIVE (STANDARD) 50 HZ 60 HZ RADIO PASSIVE (OPTIONAL) 50 P POWER 60 P POWER 100 HZ 120 HZ 31 KHZ ACTIVE (STANDARD) 512 HZ 1 KHZ 8 KHZ 29 KHZ 80 KHZ 33 KHZ (EML) ACTIVE OTHER (OPTIONAL) 400 HZ 560 HZ 815 HZ 200 KHZ BEACON (NON-ROLL) 512 HZ 29 KHZ 33 KHZ SPECIFICATIONS 950T Transmitter DIMENSIONS U.S. METRIC HEIGHT 11 IN 280 MM LENGTH 14 IN 355 MM WIDTH 4.2 IN 107 MM OPERATING WEIGHT 7.25 LB 3.3 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C MAXIMUM POWER OUTPUT 3 WATTS OPERATING MODES 512 HZ, 1 KHZ, 8 KHZ, 29 KHZ, 80 KHZ, AND DUAL (8 KHZ AND 29 KHZ) TIMER UNIT RUNS CONTINUOUSLY OR SHUTS OFF AFTER RUNNING FOR SELECTED HOUR INTERVAL (8-HOUR MAXIMUM) BATTERIES TYPE 8 D-CELL ALKALINE BATTERY LIFE APPROXIMATELY 40 HOURS (CONTINUOUS USE AT POWER LEVEL 2) *LOCATORS ARE CALIBRATED TO THESE TOLERANCES UNDER IDEAL TEST FIELD CONDITIONS. ACTUAL OPERATING FIELD CONDITIONS MAY HAVE SIGNAL DISTORTIONS OR MAY CONTAIN NOISE SOURCES WHICH RESULT IN DEPTH ESTIMATES ACCURACY THAT IS LESS THAN SPECIFIED.

SPECIFICATIONS 970T Transmitter DIMENSIONS U.S. METRIC HEIGHT 11 IN 280 MM LENGTH 14 IN 355 MM WIDTH 4.2 IN 107 MM OPERATING WEIGHT 7.25 LB 3.3 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C MAXIMUM POWER OUTPUT 5 WATTS OPERATING MODES 512 HZ, 1 KHZ, 8 KHZ, 29 KHZ, 80 KHZ, 200 KHZ (OPTIONAL), AND DUAL (8 KHZ AND 29 KHZ) TIMER UNIT RUNS CONTINUOUSLY OR SHUTS OFF AFTER RUNNING FOR SELECTED HOUR INTERVAL (8-HOUR MAXIMUM) BATTERIES TYPE 8 D-CELL ALKALINE BATTERY LIFE APPROXIMATELY 80 HOURS (CONTINUOUS USE AT POWER LEVEL 2) SPECIFICATIONS 910R Receiver DIMENSIONS U.S. METRIC HEIGHT 27.75 IN 705 MM LENGTH 12.8 IN 325 MM WIDTH 5.9 IN 145 MM OPERATING WEIGHT 4.5 LB 2 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C ANTENNA CONFIGURATIONS SINGLE PEAK, TWIN PEAK, NULL, LEFT/RIGHT (LINE ONLY) AUDIO OUTPUT SPEAKER DEPTH ESTIMATE TOLERANCES* ACTIVE LINE ± 3% 0.2-5 FT 0.06-1.5 M ACTIVE LINE ± 5% 5-10 FT 1.5-3 M ACTIVE LINE ± 10% 10 FT AND DEEPER 3 M AND DEEPER PASSIVE LINE ± 10% 0.5-10 FT 1.5-3 M BEACON ± 5% 0.5-10 FT 1.5-3 M LCD BACKLIGHT LED (GREEN) EXTERNAL PORTS RS-232 SERIAL BATTERIES TYPE BATTERY LIFE BATTERY SAVER 6 C-CELL ALKALINE APPROXIMATELY 50 HOURS (CONTINUOUS USE AT 70 F / 21 C) UNIT SHUTS OFF AFTER 5 MINUTES OF INACTIVITY OPERATIONAL FREQUENCIES PASSIVE 50 HZ 60 HZ 100 HZ 120 HZ 50 P 60 P ACTIVE 512 HZ 1 KHZ 8 KHZ 29 KHZ 80 KHZ 200 KHZ ACTIVE OTHER 400 HZ 560 HZ 815 HZ BEACON (NON-ROLL) 512 HZ 29 KHZ 33 KHZ OTHER 31 KHZ CATV PASSIVE 33 KHZ EML RADIO PASSIVE (NO DEPTH CAPABILITY)

SPECIFICATIONS 300SR Receiver DIMENSIONS U.S. METRIC HEIGHT 27.5 IN 700 MM LENGTH 11.5 IN 290 MM WIDTH 4 IN 100 MM OPERATING WEIGHT 5 LB 2.3 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C ANTENNA CONFIGURATIONS PEAK, NULL AUDIO OUTPUT SPEAKER LCD BACKLIGHT LED (GREEN) BATTERIES TYPE 6 C-CELL ALKALINE BATTERY LIFE APPROXIMATELY 40 HOURS (CONTINUOUS USE AT 70 F / 21 C) BATTERY SAVER UNIT SHUTS OFF AFTER 5 MINUTES OF INACTIVITY OPERATIONAL FREQUENCIES PASSIVE 50 HZ 60 HZ RADIO ACTIVE 8 KHZ 29 KHZ BEACON (NON-ROLL) 29 KHZ OPTION ONLY SPECIFICATIONS 300ST Transmitter DIMENSIONS U.S. METRIC HEIGHT 9.25 IN 235 MM LENGTH 12.25 IN 311 MM WIDTH 4.5 IN 114 MM OPERATING WEIGHT 5 LB 2.3 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C MAXIMUM POWER OUTPUT 1 WATT OPERATING MODES ACTIVE LINE 8 KHZ OR 29 KHZ BATTERIES TYPE BATTERY LIFE BATTERY SAVER 6 D-CELL ALKALINE APPROXIMATELY 150 HOURS (CONTINUOUS USE AT LOW POWER LEVEL) UNIT SHUTS OFF AFTER 5 MINUTES OF INACTIVITY *LOCATORS ARE CALIBRATED TO THESE TOLERANCES UNDER IDEAL TEST FIELD CONDITIONS. ACTUAL OPERATING FIELD CONDITIONS MAY HAVE SIGNAL DISTORTIONS OR MAY CONTAIN NOISE SOURCES WHICH RESULT IN DEPTH ESTIMATES ACCURACY THAT IS LESS THAN SPECIFIED.

SPECIFICATIONS 150R Receiver DIMENSIONS U.S. METRIC HEIGHT 2.37 IN 60 MM LENGTH 12 IN 305 MM WIDTH 4.37 IN 110 MM OPERATING WEIGHT 2 LB 0.91 KG OPERATION OPERATING TEMPERATURE RANGE -4 F TO 122 F -20 C TO 50 C ANTENNA CONFIGURATIONS PEAK, NULL AUDIO OUTPUT SPEAKER RECOMMENDED DEPTH RANGES* 640 BEACON IN AIR 12 FT 3.66 M 640 BEACON IN CAST IRON 6 FT 1.83 M 30K BEACON IN AIR 12 FT 3.66 M 30K ACTIVE (DIRECT CONNECT) 15 FT 4.57 M 83K ACTIVE (DIRECT CONNECT) 15 FT 4.57 M OPERATIONAL FREQUENCIES PASSIVE 50P (50 HZ) 50S (150 HZ) 60P (60 HZ) 60S (180 HZ) ACTIVE 30 KHZ 83 KHZ BEACON (NON-ROLL) 640 HZ 30 KHZ BEACONS 640 WS LENGTH 2.2 IN 56 MM FLEX ROD ¼-20 UNC DIAMETER 0.75 IN 19 MM WEIGHT 1.9 OZ 52.73 G 30K CONDUIT LENGTH 3.6 IN 91 MM FLEX ROD ¼-20 UNC DIAMETER 0.75 IN 19 MM WEIGHT 2.3 OZ 65.2 G 640 CONDUIT LENGTH 3.6 IN 91 MM FLEX ROD ¼-20 UNC DIAMETER 0.75 IN 19 MM WEIGHT 2.3 OZ 65.2 G BATTERIES TYPE BATTERY LIFE BATTERY SAVER 2 C-CELL ALKALINE APPROXIMATELY 40 HOURS (CONTINUOUS USE AT 70 F/21 C) UNIT SHUTS OFF AFTER 5 MINUTES OF INACTIVITY SPECIFICATIONS 150T Transmitter DIMENSIONS U.S. METRIC HEIGHT 3.43 IN 87 MM LENGTH 12 IN 305 MM WIDTH 6.25 IN 159 MM OPERATING WEIGHT 3 LB 1.36 KG OPERATION OPERATING TEMPERATURE RANGE -4º F TO 122º F -20º C TO 50º C MAXIMUM POWER OUTPUT 300 MW OPERATING MODES 30 KHZ, 83 KHZ BATTERIES TYPE 6 C-CELL ALKALINE BATTERY LIFE APPROXIMATELY 40 HOURS (CONTINUOUS USE AT 70 F/21 C)

SPECIFICATIONS Electronic Marker Locator [EML] EML LOCATOR ACCESSORY (LOCATES 3M MARKERS) U.S. METRIC OPERATING WEIGHT 2.3 LB 1.1 KG SHIPPING WEIGHT 4.0 LB 1.8 KG BATTERY LIFE 40 HOURS (TYPICAL) BATTERIES 6 AA ALKALINE TEMPERATURE RANGE -4 TO 122 F -20 TO 50 C OPERATING STORAGE -40 TO 158 F -40 TO 70 C SPECIFICATIONS 3M ScotchMark Electronic Markers DESCRIPTION RANGE COLOR CODE FREQUENCIES FULL-RANGE MARKER TELEPHONE 8 FT (2.4 M) ORANGE 101.4 KHZ POWER 8 FT (2.4 M) RED 169.8 KHZ WATER 8 FT (2.4 M) BLUE 145.7 KHZ WASTEWATER 8 FT (2.4 M) GREEN 121.6 KHZ GAS 8 FT (2.4 M) YELLOW 83 KHZ SHIPPING WEIGHT 1.75 LB (0.08 KG) EACH, 44 LB (19.9 KG) PER CASE PRODUCT SIZE 15" DIAMETER X 1" THICK (3810 MM X 250 MM) SHIPPING QUANTITIES 25 PER CASE, 200 PER PALLET MID-RANGE MARKER TELEPHONE 6 FT (1.8 M) ORANGE 101.4 KHZ POWER 6 FT (1.8 M) RED 169.8 KHZ WATER 6 FT (1.8 M) BLUE 145.7 KHZ WASTEWATER 6 FT (1.8 M) GREEN 121.6 KHZ GAS 6 FT (1.8 M) YELLOW 83 KHZ SHIPPING WEIGHT 5 OZ (141.8 G) EACH, 17 LB (7.7 KG) PER CASE PRODUCT SIZE 8.25" DIAMETER X 1.25" THICK (2090 MM X 320 MM) SHIPPING QUANTITIES 50 PER CASE, 600 PER PALLET 4" BALL MARKER TELEPHONE 4 FT (1.2 M) ORANGE 101.4 KHZ POWER 4 FT (1.2 M) RED 169.8 KHZ WATER 4 FT (1.2 M) BLUE 145.7 KHZ WASTEWATER 4 FT (1.2 M) GREEN 121.6 KHZ GAS 4 FT (1.2 M) YELLOW 83 KHZ CATV 4 FT (1.2 M) BLACK/ORANGE 77 KHZ SHIPPING WEIGHT 1 LB (0.45 KG) EACH, 25 LB (11.35 KG) PER CASE PRODUCT SIZE 4" (1020 MM) DIAMETER SPHERE SHIPPING QUANTITIES 24 PER CASE, 576 PER PALLET NEAR-SURFACE MARKER TELEPHONE 2 FT (0.6 M) ORANGE 101.4 KHZ POWER 2 FT (0.6 M) RED 169.8 KHZ WATER 2 FT (0.6 M) BLUE 145.7 KHZ WASTEWATER 2 FT (0.6 M) GREEN 121.6 KHZ GAS 2 FT (0.6 M) YELLOW 83 KHZ SHIPPING WEIGHT 0.88 OZ (24.9 G) EACH, 3.75 LB (1.71 KG) PER CASE PRODUCT SIZE 3" LENGTH X 0.75" DIAMETER (890 MM X 160 MM) SHIPPING QUANTITIES 50 PER CASE (PALLET N/A) *LOCATORS ARE CALIBRATED TO THESE TOLERANCES UNDER IDEAL TEST FIELD CONDITIONS. ACTUAL OPERATING FIELD CONDITIONS MAY HAVE SIGNAL DISTORTIONS OR MAY CONTAIN NOISE SOURCES WHICH RESULT IN DEPTH ESTIMATES ACCURACY THAT IS LESS THAN SPECIFIED.

SPECIFICATIONS 2150GR SYSTEM U.S. METRIC LANGUAGES ENGLISH, FRENCH, GERMAN, SPANISH, ITALIAN, PORTUGUESE, CHINESE DATA COLLECTION TYPE PARALLEL PROFILE LINES, PERPENDICULAR TO THE EXPECTED ORIENTATION OF UTILITIES SURVEY PATH WIDTH 19.7 IN 500 MM RECORDING CHANNELS 1 TRANSMITTING FREQUENCY 100 KHZ TYPICAL ANTENNA FREQUENCY 250 OR 700 MHZ TYPICAL COLLECTION SPEED 100 (SCANS/SECOND) TYPICAL COLLECTION SPEED @ 2" (5-CM) SAMPLING INTERVAL 5.6 MPH 9 KM/H DISPLAY MODE GRAY SCALE/COLOR PALETTE ZOOM UP TO 4X DATA STORAGE LAPTOP HARD DRIVE MAXIMUM PROFILE LENGTH UNLIMITED STORED DATA FORMAT RAW DATA SETTING OF GPR PROPAGATION VELOCITY GROUND TRUTH OR HYPERBOLA FITTING METHODS (TO GET ACCURATE EVALUATION OF DEPTH OF DETECTED TARGETS) READING OF PIPE POSITION/DEPTH SOFTWARE CURSOR SYSTEM OUTPUT RADAR MAP WITH DESCRIPTOR OF DETECTED UTILITIES DIAGNOSTIC RADAR AND POWER SUPPLY STATUS, EXCESSIVE SPEED, DATA LOSS RADAR POWER REQUIREMENTS BATTERY OPERATING TIME POWER SUPPLY >10 HOURS 12V SEALED LEAD ACID, 12AH MECHANICAL/ENVIRONMENTAL OPERATING TEMPERATURE 14 F TO 104 F -10 C TO 40 C HUMIDITY 100% (SEALED) WEIGHT (WITHOUT BATTERY) 19.8 LB 9 KG LENGTH (WITHOUT HANDLE) 26.7 IN 680 MM WIDTH (WITHOUT HANDLE) 31.4 IN 800 MM ENVIRONMENTAL IP65 250 MHZ ANTENNA PERFORMANCE ANTENNA TECHNOLOGY ULTRA-WIDE BAND, GROUND COUPLED, SHIELDED DIPOLE TYPICAL RANGE 0.6-8.2 FT 0.2-2.5 M MAXIMUM RANGE 0.6-19.7 FT 0.2-6.0 M 700 MHZ ANTENNA PERFORMANCE ANTENNA TECHNOLOGY ULTRA-WIDE BAND, GROUND COUPLED, SHIELDED DIPOLE TYPICAL RANGE 0.32-4.9 FT 0.1-1.5 M MAXIMUM RANGE 0.32-8.2 FT 0.1-2.5 M DUAL FREQUENCY ANTENNA TECHNOLOGY ULTRA-WIDE BAND, GROUND COUPLED, SHIELDED DIPOLE TYPICAL RANGE 0.32-8.2 FT 0.1-2.5 M MAXIMUM RANGE 0.32-19.7 FT 0.1-6.0 M

SPECIFICATIONS AF2 A-Frame Detector DESCRIPTION U.S. METRIC BATTERY 1 ALKALINE 9VDC SENSITIVITY ADJUSTABLE BALANCE (METER CENTERING) ADJUSTABLE DIRECTION INDICATOR ANALOG METER IS INTENDED TO SHOW DIRECTION TO THE FAULT WHEN THE DETECTOR ORIENTATION IS CORRECT (RED PROBE TOWARD THE TRANSMITTER, BLACK PROBE DOWN THE CABLE PATH) BATTERY INDICATOR INDICATES BATTERY CONDITION REMOTE PROBE ON/OFF, ELECTRONICALLY DISCONNECTS THE RED A-FRAME PROBE AND CONNECTS THE REMOTE PROBE SPECIFICATIONS FT14 Transmitter DESCRIPTION U.S. METRIC BATTERY 6 D-CELL ALKALINE OR EXTERNAL 12VDC SOURCE; 12VDC @ 24 WATTS PULSING; 12VDC @ 0.5 WATTS NORMAL; 12VDC INPUTS PROTECTED WITH 4-AMP PANEL MOUNT FUSE (INSIDE BATTERY COMPARTMENT) BATTERY INDICATOR INDICATES BATTERY CONDITION OUTPUT VOLTAGE 2300-2500VDC INITIAL, ACROSS 10-MEGAOHM LOAD; OUTPUT PULSE RATE IS ONE PULSE EVERY 3-4 SECONDS; OUTPUT PULSE DURATION IS TYPICALLY 200 MILLISECONDS FAULT IMPEDANCE INDICATOR GIVES APPROXIMATE VALUE TO FAULT OUTPUT TONE USER SELECTABLE ON/OFF OUTPUT LIGHT USER SELECTABLE ON/OFF

THE CHARLES MACHINE WORKS, INC. DITCH WITCH WORLDWIDE HEADQUARTERS PERRY, OK 73077-0066 U.S.A. TOLL FREE 800 654 6481 PHONE 580 336 4402 FAX 580 336 3458 INTERNATIONAL FAX 580 572 3561 ASK ABOUT THE DITCH WITCH PLATINUM CARD AND DITCH WITCH FINANCIAL SERVICES TO FIND THE DEALER NEAREST YOU, VISIT DITCHWITCH.COM GROUNDBREAKING EQUIPMENT FROM THE COMPANY THAT LAUNCHED THE INDUSTRY COMPACT UTILITY TRENCHERS HDD ELECTRONICS CERTIFIED QUALITY MANAGEMENT SYSTEM ISO 9001:2000 LFCMWL2045-0907-1 2007 The Charles Machine Works, Inc.