ELECTRICAL CABLE SPLICE KIT. Roctest Limited, All rights reserved.

Similar documents
Product Manual MNX10050 / REV B MODELS:

Product Manual MNX10050 / REV C MODELS:

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

SKDG Cable Repair Kit Instructions

UPC-LL Power Connection Kit

ELECTRICALLY LONG NGP ANTENNA SYSTEMS

3M 200 Amp Loadbreak Connector System

1.0 Tool Components and Operation Instructions

Spiderbeam Balun Construction Guide

Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable

1.0 Tool Components and Operation Instructions

Water Level Meter: Op Instructions

SELF-ALIGNING PLASTIC INCLINOMETER CASING IN BOREHOLES. Model GEO-LOK. Roctest Limited, All rights reserved.

GORE Aerospace Ethernet Cables

Pacific Antenna RF Probe assembly

C99-20LL System Cable P/N 40935G-06 INSTALLATION SHEET

Bel Stewart Connector

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

GORE Aerospace Ethernet Cables

Terminal Replacement Procedures

General characteristics and technical data Series VarioPro Basic

3M Electrical Markets Division 3M Cold Shrink Silicone Rubber Splices QS-III. Easy Installation. High reliability.

3M Power Clamp Wiremount Connectors

Termination of D-621 Triaxial Connectors to Shielded Twisted Pair Cable for MIL-STD-1553B Applications

Manual Assembly of PureID DIY Cables

ARCTIC TRACE INSTALLATION INSTRUCTIONS 352C Hazardous Location Water Proof Strain Relief Kit for TL Series Heating Cable

THE TOOLS RECOMMENDED Phillips Screwdriver Stripper/Crimper Electrician Pliers ½ open end wrench or ratchet wrench with ½ deep socket Utility knife

Service Bulletin Terminal Replacement Instructions (Replaces , dated May 2, 1995) December 18, 2000 ALL

AMPLIMITE Cable Connectors and Shielding Hardware Kits

Risk Assessment & Safe Working Practice

Modifying a USB sound fob to act as a repeater interface for app_rpt

Pacific Antenna 20 and 40M Lightweight Dipole Kit

AEE. Canada. Australia

Pacific Antenna 20 and 40M Lightweight Dipole Kit

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

Product Specification provides test results and product performance requirements.

87.5 TO MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA

Repairing MagSafe Connector

User Guide.

No crimping is required just solder the the wire to the crimp piece and use some heat shrink tubing to cover the end of the crimp.

QSLVM2500 QSLV-M Cold Shrink Insulator

insulate seal protect EquipmEnt insulation and ConnECtion products

K1FO 12 ELEMENT 144/147 MHz YAGI

ELECTRICAL WIRING SOLDERING AND CRIMPING Article No. REPAIRS SERVICE TIPS

JCN cables. The. splice is an

C-L-X ARMOR REMOVAL PROCEDURES

PO Box 1879, 515 Tucker Ave. Friday Harbor, WA Phone: (360) Fax: (360)

1. General Repair Methods

SELF-ALIGNING PLASTIC INCLINOMETER CASING IN BOREHOLES. Model GEO-LOK. Roctest Limited, All rights reserved.

DiiVA DIY Field Termination User Manual For terminating Cat6 cables with DiiVA connectors

Miniature Waterproof Shielded Connectors

COOLEDGE TILE GEN2 INTERIOR-TUNABLE WHITE INSTALLATION MANUAL

MiniSeal D-436 Series Sealed Crimp Splice Products Installation Guidelines

Wiring Repair WIRING REPAIR

E2500 Antenna Installation Instructions:

Reasons for reissue are in Section 6, REVISION SUMMARY.

TERMINATION & SPLICING OF SHIELDED PRODUCTS

BIG CEE. ENGINEERING 627 N Michigan Ave #5 Pasadena, CA

1.0 Receiver TAC Contact Insertion/Extraction. 2.0 TAC (Receiver) Module Installation/Removal. 3.0 Wiring Contact Insertion/Extraction

Miniature Waterproof Shielded Connectors

Pacific Antenna 20 and 40M Lightweight Dipole Kit

LAGGING PIPES UP TO 125 mm IN DIAMETER WITH K-FLEX TUBING

4200 JSP, KSP, LSP and MSP Cabinets

unit 3: GENErAL ElectriCAL SySTEM DiAGNOSiS

Builder s Log Helicycle N750G

Patent pending. Product Manual

Miniature Waterproof Shielded Connectors

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.

EP-60 END OF CAR JUNCTION BOX KIT and ASSEMBLY AND INSTALLATION INSTRUCTIONS

CRIMP CONNECTORS & ACCESSORIES Universal Crimp Termination System. Heavy-duty lightweight stamped steel frame.

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

Signal Mirror Installation Instructions

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

2 Recommended Tools / Supplies

Powersafe Termination Guide

Installation & Weatherproofing Guide for ENCOM Broadband Radios

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Electrical - Wiring Soldering/Crimping Service Tips

MI: (Secure this number someplace, for possible future need) SPECIFICATIONS:

BARCO PROJECTION SYSTEMS

Elektor Construction Guide TAPIR

MINI-SAS HIGH DENSITY

kwiqmate Connectors Product Catalog Johnson

LESLIE CONSOLE CONNECTOR KIT 8400 INSTALLATION INSTRUCTIONS

Instructions for Preparing OPTICAL GROUND WIRE IN AN ISOLATOR

PEM130ENG 02/08 SJK & SJKK INSTALLATION INSTRUCTION ENGLISH. 1 kv JOINTS FOR 4 TO 4 CORE AND 4 TO 3+1 CORE PLASTIC INSULATED CABLES SJK & SJKK

Installation Instructions

Hatchback Wing Riser Kit

Detailed Specifications & Technical Data

SERVICE ADVISORY SA-11

Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions

Arducopter 3DR-B Hardware

Miniature Waterproof Shielded Connectors

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

Product Bulletin. Quick-Build Harness Board System

Installation Manual. Seasons Collection. Models: OS54 OS56 OS54DT OS64 OS66 OS64DT

75 Ω SSMB Type Connectors

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Construction Guide: Spiderbeam 40m Add-On Dipole

Transcription:

INSTRUCTION MANUAL ELECTRICAL CABLE SPLICE KIT Roctest Limited, 2014. All rights reserved. This product should be installed and operated only by qualified personnel. Its misuse is potentially dangerous. The Company makes no warranty as to the information furnished in this manual and assumes no liability for damages resulting from the installation or use of this product. The information herein is subject to change without notification. E1135-140528 Tel.: 1.450.465.1113 1.877.ROCTEST (Canada, USA) 33.1.64.06.40.80 (France) 41.91.610.1800 (Switzerland) www.roctest.com

TABLE OF CONTENTS 1 INTRODUCTION... 1 2 SPLICE KIT... 1 3 SPLICING PROCEDURE... 1 3.1 Non-vented electrical cable... 1 3.2 vented electrical cable... 2 4 FIGURES... 4 i

1 INTRODUCTION The following instructions can be applied to the following splice kit models: FR-1135050900 FR-1135050900A FR-1135050900B 2 SPLICE KIT All splice kits include: One (1) splice sleeve Two (2) connectors FR-1135050900BV FR-1135050900C FR-1135050900D Splice kits FR-1135050900BV & FR-1135050900EV also include: Note: One (1) capillary metal tube FR-1135050900E FR-1135050900EV FR-1135050900F Roctest recommends using the 3M Scotchcast electrical insulating Resin 4A. See detail here: http://bit.ly/m4v8h6. There is no resin included in the splice kit. The 3M Scotchcast electrical insulating Resin 4A is considered a Dangerous Good and since there are restrictions of the Transportation of Dangerous Goods, Roctest recommends getting the resin at its point of use when possible. However, Roctest can provide the resin as a separate item if ground shipment is possible (Roctest P/N: 05-0027C0080). 3 SPLICING PROCEDURE For non-vented electrical cables (most common), see section 3.1 For vented electrical cables, see section 3.2 3.1 NON-VENTED ELECTRICAL CABLE Different splice kit models are available as explained on section 1 and as illustrated on Figure 1 to 4 below. However the splicing method is almost the same for all type of splice kit as explained in the following step. Small modifications can be done on field according to the model of cable and splice kit used. 1. Cut carefully both ends of cable to splice. 2. Clean carefully both ends of the electric cable to be spliced over approximately 20 cm. 3. Slide the free connector on one end of the cable. On the other end, slip on the splice sleeve - with the second connector screwed on it - until the end of the cable exceeds the sleeve approximately 30 cm (see illustration "A"). 4. On both ends of the cable, remove approximately 3 cm of the outer jacket. Remove 1 cm of insulation jacket on each (see illustration "B"). Do not get rid of the braid shield if it exists, as it will be reconnected afterwards. With the Roctest IRC-41A cable or similar, discard the aluminum foil but keep the drain wire. Page 1

5. Make the connection of each conductor respecting the colour code. For best results, the use of a soldering iron with soldering wire is highly recommended. Skilled personnel should conduct the soldering operation in order to avoid "cold" solders. Isolate each conductor with heat shrink tubing (3/32 diameter) or, if not available, electrical tape (see illustration "D"). 6. Form a twisted wire with braid shield or drain wire and solder each end together, again using a soldering iron. 7. If applicable, attach each end of central reinforcement core suitably, in order to restore mechanical strength of cable, either by using a suitable crimp, or brazing. In the latter case, be careful not to damage the conductors when using the brazing torch. 8. Tie all the connections together by using electrical tape (see illustration "E"). 9. Slide and center the splice sleeve over the connections and screw tight the first connector to the end of the sleeve. 10. Prepare the resin as per the manufacturer s instruction. 11. When the resin is ready, hold the sleeve vertically and pour it in the opening left by the unscrewed connector. 12. When filled up, slide and screw the second connector. 13. If you have plug on sleeve as illustrated on Figure 4 then you can screw both connectors and fill the resin by one hole until resin evacuated from the second hole. Then screw both plugs and let the resin dry. 3.2 VENTED ELECTRICAL CABLE 1. Cut carefully both ends of cable to splice. 2. Clean carefully both ends of the electric cable to be spliced over approximately 20 cm. 3. Slide the free connector on one end of the cable. On the other end, slip on the splice sleeve - with the second connector screwed on it -until the end of the cable exceeds the sleeve approximately 30 cm (see illustration "A"). 4. On both ends of the cable, remove approximately 3 cm of the outer jacket. Remove 1 cm of insulation jacket on each conductor and of one end of vent tube(s) (see illustration "B"). Do not get rid of the vent tube(s), braid shield if they exist, as they will be reconnected afterwards. With an IRC-41A cable or similar, discard the aluminium foil but keep the drain wire. 5. Make sure about 2 cm of heat shrink (1/16 diameter) is slid on one side of each vent tube and insert the capillary metal tube in both ends of each vent tube, respecting the colour code (see illustration C ). Pull the shrink tube to overlap both ends of the vent tube and heat it up to complete the connection of the vent tube. 6. Make the connection of each conductor respecting the colour code. For best results, the use of a soldering iron with soldering wire is highly recommended. Skilled personnel should conduct the soldering operation in order to avoid "cold" solders. Isolate each conductor with heat shrink tubing (3/32 diameter) or, if not available, electrical tape (see illustration "D"). Page 2

7. Form a twisted wire with braid shield or drain wire and solder each end together, again using a soldering iron. 8. Attach together each end of central reinforcement core suitably, in order to restore mechanical strength of cable, either by using a suitable crimp, or brazing. Be careful not to damage the conductors when using the brazing torch. 9. Tie all the connections together by using electrical tape (see illustration "E"). 10. Slide and center the splice sleeve over the connections and screw tight the first connector to the end of the sleeve (if not already in place). 11. Mix the resin as per the manufacturer s instruction. 12. When the resin is ready, hold the sleeve vertically and pour the resin in the opening left by the unscrewed connector. 13. When filled up, slide and screw the second connector. Page 3

4 FIGURES Figure 1: Steps for cable splicing with T&B connectors Page 4

Figure 2: Cable splicing assembly with T&B (metal) connectors (FR-1135050900C) Figure 3: Cable splicing assembly with PVC connectors for IRC-41A cable (FR-1135050900) Figure 4: Cable splicing assembly with IRC-390 cable with vented plug (FR-1135050900E) Page 5