CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Similar documents
KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

User Manual CTP4/8/16

Telemetrie-Messtechnik Schnorrenberg

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

Kraus Messtechnik GmbH

MTP-NT. Preliminary version Sophisticated multi-channel telemetry system for rotating application, fully software programmable with 16 bit resolution

MTP-NT INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

User Manual MTP Multi-channel telemetry system for rotating application, full software programmable with 16 bit resolution

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

Digital Telemetry Solutions

SC-4/M User manual 4-channel measuring amplifier

Digital Telemetry Solutions

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Kistler LabAmp for DynoWare

Calibration and Testing

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction

Dx: Digital Multi-Channel Telemetry System

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Series GLET Accessory for dataloggers series GL in modular enclosure

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Digital RMC-Sensor-Telemetry with 16 Bit resolution and direct PC Interface

Special Solution for Wheel and Axial Shafts Wheel transmitter, Universal shaft transmitter

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

WIND VANE THIES COMPACT

Modular Radio Telemetry System

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Modular Radio Telemetry System

Modular Smart Interfaces

Product Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface

The universal Data Acquisition system

imc C-SERIES: CS-1016-N, CL-1032-N

ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

Torque Sensor Accessories and Services

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

ULTRASTAB I U Precision

Paperless Recorder PR20

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MX1615. Data sheet. Bridge/strain gauge amplifier

Wind Transmitter First Class

Signal Conditioning Amplifier

200, 201 Series Radio Telemetry Transmitters

GSV-2MSD-DI IP43. Highlights

Developer Techniques Sessions

Configuration (modular inductive Telemetry)

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

5-step-switch for adjustment of sensitivity (switching threshold) LED (super-bright, yellow) for switching state indication.

Model Channels Input type Sample rate Resolution

Temperature Transmitters - Head Mounted

AN Wireless analog data acquisition system with 4-20 ma (current loop) inputs and built-in data logger

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

MCTS II Multi Channel Current Transducer System. Installation Manual

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

FO-TX 2-EC FO-TX 2-OPT FO-RX 2-EC

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

RMC S ENSOR TELEMETRY. A Sensortelemetrie M MANNER. FGP Sensors & Instrumentation

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

Digital FM Telemetry Steering Effort Sensor from Sensor Developments Inc Model Installation & Operators Manual 2.4

FC-33, DC SELECTABLE SIGNAL CONDITIONER

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Load Cell Accessories and Services

Force and strain sensors. Measure. Test. Control. Edition 2016

Analog Isolation Amplifiers

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

Technical data. Your advantages

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

CSG110 Strain Gauge Universal Amplifier

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

WIND VANE THIES FIRST CLASS 2014 TMR

RTD), LM335 Voltage, or AD592 current. c. Constant TE Current (8350 only)

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Radio Sensortelemetry

96x48. m/s. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output. Sensor supply

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

ULTRASTAB IHF Precision Current Transducer

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wireless Strain Gauge System

Transducer for Measurement Bridges SCM90, SIGS15

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Product Information. ECN 1313 ECN 1325 ERN 1387 Rotary Encoders with Plane-Surface Coupling for Elevator Servo Drive Control

Components Signal Conditioning For Your Computer Instruments Standard Models

Transcription:

KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP16-Rotate 16 channel telemetry for rotating applications like wheels or rotors, high signal bandwidth, 16bit, software programmable Inputs for STG, TH-K, ICP, VOLT Battery power up to 8-10h Simultaneous sampling 16 bit resolution Software programmable Signal bandwidth: 16 x 0-6000Hz Radio telemetry transmission Output analog +/- 10V Digital data interface to PC (option) Waterproofed ENC housing (IP65)

General functions: The CTP16-Rotate is a 16-channel telemetry system for rotating applications with integrated signal conditioning for sensor signals, wireless digital transmission and analog reproduction. In the encoder/transmitter unit the sensor signals are conditioned, filtered (anti-aliasing) and digitized (16-bit). Simultaneous sampling is provided for all channels. Finally, the PCM encoded data is transmitted via radio frequencies to the receiver. Various configurations of different sensor modules are available incl. signal conditioning for strain gages (STG), thermocouples type K (TH-K), Pt100/1000, ICP sensors, potentiometer sensors (POT) and also voltage inputs. Mixed configuration available (2-CH-steps). All sensor modules are software programmable via LAN-Adapter. The LAN-Adapter has an integrated web interface and enables easy access to modules! The stationary receiver provides 16 +/-10V analog outputs via Sub-D male socket (option: digital PC interface). The analog signal bandwidth is 0-375 Hz (320kbit) and up to 0-6000Hz (5000kbit) for 16 channels. The measurement accuracy is <±0.2 % (without sensor). The CTP16-Rotate is specified for operational temperatures from -20 C to +70 C. The maximum distance between transmitter and receiving antenna is approx. 10-20 m (30-60 feet) depending on the application! Mixed configuration available (2-CH-steps). Specify CTP-xx modules at order!! Frequency table Cut off frequency from anti-aliasing filter (-3dB) and sampling rate (see red) Bit rate 16 CH. 5000kbit 6000Hz (15625Hz) 2500kbit 3000Hz (7812.50Hz) 1250kbit 1500Hz (3906.25Hz) 625kibt 750Hz (1953.125Hz) 312.5kbit 375Hz (976.56Hz) CAR wheel Truck wheel Helicopter rotor Version 2016-05 2 Technical Data are subject to change without notice!

CTP16-Rotate Transmitting Unit Technical Data (Encoder) Encoder in IP65 Aluminum housing System Parameters ENCODER: Channels: 16 Resolution: Line-of-sight distance: Powering: Power consumption: Analog signal bandwidth: Transmission: Transmission Power: Dimensions: Operating temperature: Housing: CTP acquisition modules (rotor side) CTP-STG-V3 Acquisition module for 2 strain gages Full, half and quarter bridge ( 350 ) Fixed excitation 4V DC Offset calibration by auto zero Manual offset shifting after auto zero Gain: 125-250-500-1000-2000 Test shunt-cal step Signal bandwidth 0Hz to 6000Hz* Current consumption with full bridge 350 ohm 75mA CTP-ICP -V3 - Acquisition module for 2 ICP sensors Current EXC. 4mA, 28V Gain: 1-2-4-8-16-32 Signal bandwidth 3 Hz to 6000Hz* (*see table of cut-off-frequency) Current consumption 100mA CTP-Pt100/1000 (RTD) V3 Acq. module for 2 RTD sensors Range -100 to 600 C, -50 to 300 C or -25 to 150 C Type Pt100 or Pt1000 Current EXC. 1mA Connection: 4-, 3- and 2 wire Sensor break detection Signal bandwidth 6Hz Current consumption 60mA Encoder inside 16 bit A/D converter with anti-aliasing filter, simultaneous sampling of all channels up to 20m (depends of application and bit rate) Li Ion Accumulator 7.2V, 7800mA, capacity up to 8-10 hours 700 ma using 16x STG full bridge sensors 350 Ohms See table Digital PCM Miller format - FSK 10mW! Diameter 190mm, bottom plate diameter 220mm, height 70mm (without antenna) 2.00kg without sensor cables and antenna - 20 +70 C Aluminum anodized, waterproofed (IP65) 20... 80% no condensing 5g Mil Standard 810C, Curve C 100g in all directions, 2000 RPM 200g in all directions CTP-VOLT-V3 Acquisition module for 2x high level inputs Range: ±0,625V, ± 1,25V, ±2,5V, ± 5V, ±10V Signal bandwidth 0Hz to 6000Hz* (*see table of cut-off-frequency) Current consumption 60mA CTP-TH-K-V3 Acquisition module for 2x TH-K Inputs galvanic isolated Range -50 to 1000 C, -50 to 500 C or -50 to 250 C Cut-off filter 30Hz (more on request) Accuracy: 0.2% at 1000 C range Current consumption 110mA CTP-CONTROL-V3 Controller 1-32 acquisition modules Output: PCM Programmable via LAN adapter Current consumption 40mA, with LAN-adapter 140mA Technical specifications are subject to change without notice! Version 2016-05 3 Technical Data are subject to change without notice!

CTP-DEC16 Receiver unit for max 16 Channels output via 37 pol. Sub D (radio transmission version with diversity receiver 312.5 1250kbit) Front side view Rear side view Female 37 pole Sub-D for analog signal output, CH 1 to 16 Auto Zero LED Bright on, if analog output is over 60mV Low Pwr LED ON = BATT empty! Power Switch Transmission error LED Fuse of powering defect LED 7-pole female TUCHEL connector for power supply input (10 30V DC) PCM out for IP-LAN-Interface (Opt.) (Option) HF Field strength display SMA antenna connector with active LED of antenna (diversity) Channel: Resolution: Power supply input: Transmission: Dimensions: Plug-side Optional BNC16 Box. Connect on 37pol Sub-D CTP DEC16 System Parameters: 16 x +/-10V analog outputs via Sub-D male socket 16 bit D/A converter, with smoothing filter 10-30 VDC, power consumption <24 Watt Digital PCM Miller Format FSK, 205 x 105 x 65mm 1.25 kg without cables and antenna Overall system accuracy between encoder input and decoder output: +/-0.25% without sensor influences Environmental Operating: -20 +70 C 20... 80% not condensing 5g 10g in all directions 100g in all directions Version 2016-05 4 Technical Data are subject to change without notice!

CTP-DEC16 Receiver unit for max 16 Channels output via 37 pol. Sub D (radio transmission version via quad receiver for 2500kbit and 5000kbit) Front side view Female 37 pole Sub-D for analog signal output, CH 1 to 16 GND cable to ground the housing Rear side view Low Pwr LED ON = BATT empty! Power ON LED Power Switch Transmission error LED Fuse of powering defect LED 7-pole female TUCHEL connector for power supply input (10 30V DC) PCM IN coming from HF-BOX Plug-side Optional BNC16 Box. Connect on 37pol Sub-D CTP - DEC16 System Parameters: Channels: 16 x +/-10V analog outputs via Sub-D male socket Resolution: 16 bit D/A converter, with smoothing filter Power supply input: 10-30 VDC, power consumption <24 Watt Analog signal bandwidth: see frequency table Transmission: Digital PCM Format Dimension: 205 x 105 x 65mm 1.00kg without cables and antenna Overall system accuracy between encoder input and decoder output: +/-0.2% without sensor influences Environmental Operating: -20 +70 C 20... 80% not condensing 5g 10g in all directions 100g in all directions Version 2016-05 5 Technical Data are subject to change without notice!

CTP-DEC16 Receiver unit for max 16 Channels output via 37 pol. Sub D (radio transmission version via quad receiver for 2500kbit and 5000kbit) PCM OUT Pin 1 ----- Pin 2 = PCM + (pink wire) Pin 3 = PCM -- (blue wire) Pin 4/5 = common GND & shield (black/green) Pin 6 ----- Transmission error LED Fuse of powering defect LED GND cable to ground the housing 4x HF Level display Active DATA LED, up to 2 receivers can be active! If a fault data is identified, it will switch automatically to a valid data from other receiver 7-pole female TUCHEL connector for power supply input (10 30V DC) 4x SMA inputs for RX antenna Power Switch PCM/ DATA cable Length 0.5m standard (up to 25m on request) HF BOX Quad System Parameters: HF receivers 4 Antenna connection SMA Output PCM Power supply input: 10-30 VDC, power consumption <24 Watt Dimensions: 205 x 105 x 65mm 1.05 kg without cables and antenna Environmental Operating: -20 +70 C 20... 80% not condensing 5g 10g in all directions 100g in all directions Version 2016-05 6 Technical Data are subject to change without notice!