ELPF Load Cell DESCRIPTION

Similar documents
FC22 Compression Load Cell

Altitude and Airspeed Measurements Temperature Range. Range psid psig psia 0 to 1 0 to 5 0 to 15 0 to 30 0 to 50 0 to to to 300

FC22 Compression Load Cell

A Simple Pressure Sensor Signal Conditioning Circuit

XP5 Miniature pressure sensor

P125 High pressure sensor

Signal Conditioning for MEAS Pressure Sensors

U5700 Submersible Liquid Level Pressure Transducer

XPC10 High temperature miniature pressure sensor

M5200 Industrial Pressure Transducer

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

P-Series Inclinometer

Accelerometer ACH-01. Piezoelectric Accelerometer Wide Bandwidth; AC Coupled Ultra Low Power High G Ranges

MiniSense 100 Analog PCB

U5200 Industrial Pressure Transducer

NDT1-220K Ultrasonic Transducer

Miniature pressure sensor

U5300 Industrial Pressure Transducer

AccuStar Electronic Clinometer

80 khz Cylindrical Ultrasound Transducer

Model 140 Inline Amplifier

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Linear measurement with a magnetic pole stripe (I 2 C-Mode)

Freescale Semiconductor Data Sheet: Technical Data

EPIH Sub-Miniature Pressure sensor

E2-Series Inclinometer

OPERATION MANUAL LDM-1000

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

MPXM2051G, 0 to 50 kpa, Gauge Compensated Pressure Sensors

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

TSYS02S Digital Temperature Sensor

HTM25X0LF Temperature and Relative Humidity Module

HM1500LF Relative Humidity Module

ED-17 Serial Output Magnetic Encoder

Model LBS Miniature Compression Load Button

PSI Temperature Scanners

M5800 Pressure Transducer with Rotatable Display


Load Cell Accessories and Services

Freescale Semiconductor, Inc. SEMICONDUCTOR TECHNICAL DATA

Signal Conditioning Amplifier

MODEL AT-10 ANALOG TRANSMITTER

Freescale Semiconductor, I

Instruction Manual Single and Dual Axis Inclinometer V-Series

SEMICONDUCTOR TECHNICAL DATA

MPX2010 SEMICONDUCTOR TECHNICAL DATA. COMPENSATED PRESSURE SENSOR 0 to 10 kpa (0 to 1.45 psi) FULL SCALE SPAN: 25 mv

HS1101LF Relative Humidity Sensor

HTG3500 Series Relative Humidity and Temperature Module

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Freescale Semiconductor, I

Signal Conditioning Amplifier

P-Series Inclinometer

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Freescale Semiconductor, I

V-SERIES INCLINOMETER

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

TSYS01 Digital Temperature Sensor

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Freescale Semiconductor

Signal Conditioning Amplifier

FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output Up to ±0.1% Accura

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Non-Submersible Industrial Pressure Transducer

Model 3A Series 3-Axis Load Cell

Pressure Sensors, Accelerometers, and Custom Microstructures

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

ORDERING INFORMATION # of Ports Pressure Type Device Name Case No.

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

HTM2500LF Temperature and Relative Humidity Module

M5200 Industrial Pressure Transducer

Model 3A Series 3-Axis Load Cell

up to 200 C, 4007B... Technical Data 4007B, General Measuring range bar Overload bar Power supply ma* 1 Output signal (FS

Instruction Manual Single and Dual Axis Inclinometer P-Series

CSG110 Strain Gauge Universal Amplifier

Installation and Operating Manual

Freescale Semiconductor, I

miniature pressure sensors

INSTRUCTION MANUAL. IM7298, Revision A ( )

bar, Type 413xA..., 414xA... Technical Data (based on Tref = 25 C; power supply 1 ma constant) Type 413xA... 0,2... 0,

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

SEMICONDUCTOR TECHNICAL DATA

U5300 Industrial Pressure Transducer

LM118/LM218/LM318 Operational Amplifiers

Making Basic Strain Measurements

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

SEMICONDUCTOR TECHNICAL DATA

CTE7000 Series Miniature pressure transmitters

Wirewound Resistors, Military, MIL-PRF Qualified, Type RE, Aluminum Housed, Chassis Mount

Hygro-ThermoTransmitter-compact xxx

SINGLE PHASE HALL EFFECT LATCH General Description. Features. Applications

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

SL MHz Wideband AGC Amplifier SL6140. Features

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter

H(T)U(F)3500 SERIES Analog Relative Humidity module with Temperature output

Transcription:

Compact Tension/Compression Design 10 500 lbf High Level and mv Output High Stability Industry Standard Packing Resists Off Axis Load Components Full NIST Traceable 11 Point Calibration Shielded Teflon Cabling with Strain Relief IP65 Rating DESCRIPTION The ELPF series tension/compression load cells raise the bar for high performance at low cost. proprietary Microfused technology, derived from demanding aerospace applications, employs micro-machined piezoresistive strain gages fused with high temperature glass to a high performance stainless steel force measuring flexure. Microfused technology eliminates age-sensitive organic epoxies used in traditional load cell designs providing excellent long term span and zero stability. Operating at very low strains, Microfused technology utilizes strain gages providing gage factors greater than 100, an essentially unlimited cycle life expectancy, superior resolution, exceedingly high over-range capabilities (without the need for stops) and an amplified ratiometric high level 0.5 to 4.5 V output or 20 mv/v bridge output. Microfused sensors are ideal for your test and measurement applications. ELPF Test and Measurement series sensors, unlike most competitive designs, are provided with a "four-bar" design where a flexible diaphragm parallels the measuring flexure. This configuration is far less susceptible to off-axis load components than single diaphragm traditional designs. Shielded, Teflon insulated instrumentation cabling is provided along with spring steel strain reliefs and full NIST traceable calibration certificates. The ELPF unit is fully thermally compensated and will provide an essentially unlimited cycle life expectancy. The ELPF can be configured with a variety of options to fine-tune the instrument to your application: select from several standard package geometries, compensated temperature ranges, input voltages, lead lengths or specify entirely unique combinations of these options. FEATURES APPLICATIONS Low Cost Theatrical Rigging Loads Optional High Level Output Assembly Forces Small, Low Profile Design Weighing Low Noise Tool Forces Robust: High Over-Range Thrust Measurements High Reliability Batch Weighing Low Deflection Robotics End Effectors Low Off-Axis Response Product Validation Testing Fast Medical Instruments Essentially Unlimited Life Cycle Hoist and Winch Loads IP65 Rating 1/5

STANDARD RANGES Lbf N Body Style 10 50 T1 20 100 T2 50 250 T2 100 500 T3 200 1K T3 500 2.5K T3 PERFORMANCE SPECIFICATIONS Supply Voltage: 5V Ambient Temperature: 25 C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Output Span (Amplified/Ratiometric) 0.5 to 4.5 ±3% Span V Output Span (Bridge Output) ±5.0 ±5 %Span mv/v Zero Force Output ±5 %FSO 1 Non Linearity ±0.25 %FSO Hysteresis ±0.25 %FSO Temperature Error Zero (Over Compensated ±0.01 %FSO/ C Temperature Range) Temperature Error Span (Thermal Sensitivity Shift ±0.01 %/ C Over Compensated Temperature Range) Maximum Over Load 250 % Impedance In 3 KΩ Impedance Out 2.2 KΩ Compensated Temperature 20 80 C Operating Temperature -40 +120 C Storage Temperature C Excitation Voltage 5 Vdc Isolation Resistance (250Vdc) 50 MΩ Deflection at Rated Load <0.05 mm Cycle Life Expectancy Essentially Unlimited Solder Temperature Notes 1. Re: Zero output: Lower trim values available on request. Application Schema Remarks Positive output in compression. Laser welded stainless steel body construction. Spring strain relief and shielded Teflon cable provided standard. Unique 4 bar linkage design provides resistance to off axis load components. 2/5

DIMENSIONS 3/5

OPTIONS Standard Compensation Range: 20 to 80 C Z0: -40 to +20 C Z1: -20 to +40 C Z2: 0 to 60 C Z*: Nonstandard compensation temperature range Excitation Voltage (Bridge Output): 5 Vdc standard V00: Replace 00 with excitation between 1 and 10V. (At excitations less than 5V, sensitivity decreases proportionately.) Sensitivity at excitations > 5V equals 20mV/V.) V2.5: Sensitivity equals 50 mv FSO nominal. V10: Sensitivity equals 100 mv FSO. Note that input impedance may increase substantially when excitations > 5Vdc are specified. Excitation Voltage (Amplified): 5 Vdc standard (higher excitations available: Consult factory.) Standard Cable Length = 5ft (1.5m) L00F: Replace 00 with total cable length in feet. Specified only on units with SAE threads and lbf range. L10F: Units provided with 10 ft total cable length. Specified only on units with SAE threads and lbf range. L00M: Replace 00 with total cable length in meters. Specified only on units with metric threads and N range. L6M: Units provided with 6m total cable length. Specified only on units with metric threads and N range. L10M: Units provided with 10m total cable length. Specified only on units with metric threads and N range. MXXP: MXXP Special Compensation Module Location: Replace XX with percentage of cable length. M10P: Module located at 10% of cable length ±5% M25P: Module located at 25% of cable length ±5% M50P: Module located at 50% of cable length ±5% M75P: Module located at 75% of cable length ±5% C: Microtech type male or equivalent (w/o mate) R: RJ Telephone type male (w/o mate) AN: Calibrate lbf range unit in Newtons AL: Calibrate N range unit in lbf AC: Alternate calibration: Units with studs are calibrated in tension by default. Option AC provides compression calibration in addition to tension calibration. AMP: Provides amplified, ratiometric output of 0.5 4.5V in tension only. Amplified units with option AC for amplified operation in tension and compression: Zero trimmed to +2.5Vdc ± of 2V ±3% span in tension and compression at 5 Vdc input. ELECTROMAGNETIC COMPATIBILITY: RESIDENTIAL, COMMERCIAL, AND LIGHT INDUSTRIAL 4/5

ORDERING INFORMATION ELPF - T3 E - 500 N - /V10/M25P/... Options (See Options Table) Units (L = lbf, N = Newton) Multiplier (K for ranges > 1000) Range Thread Type (M = Metric, E = SAE) Body (T1, T2, T3) Model NORTH AMERICA EUROPE ASIA 45738 Northport Loop West Fremont, CA 94538 Tel: 1-800-767-1888 Fax: 1-510-498-1578 Sales: pfg.cs.amer@meas-spec.com (Europe), Ltd. 26 Rue des Dames 78340 Les Clayes-sous-Bois, France Tel: +33 (0) 130 79 33 00 Fax: +33 (0) 134 81 03 59 Sales: pfg.cs.emea@meas-spec.com (China), Ltd. No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen 518107 China Tel: +86 755 3330 5088 Fax: +86 755 3330 5099 Sales: pfg.cs.asia@meas-spec.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer., Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. 5/5