Kotron Model 82 CE RF Level Transmitter

Similar documents
Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter

Echotel Model 910 Ultrasonic Level Switch

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Echotel Model 911/921 Ultrasonic Level Switches

Solitel Vibrating Rod Level Switch

Solitel Vibrating Rod Level Switch

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Kotron Series 82 CE. Level. Transmitter. Installation and Operating Manual

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Model 961/962 Ultrasonic Level Switches

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Guided Wave Radar Liquid-Liquid Interface Transmitter

Echotel Model 350/351

Horizon Model 704 Guided Wave Radar Level Transmitter

RF Capacitance Level Controls

Non-Submersible Industrial Pressure Transducer

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

IP26 Series Current to Pneumatic Converter

670K9 SORtrax Level Transmitter

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

RF Capacitance Level Controls

Instruction Manual. HB Series Mini Level Sensor

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

HORIZON 704. Guided Wave Radar Level Transmitter. Worldwide level and flow solutions

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 3101, 3102, and 3105

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Princo MagneLevel Model LML

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

H O R I Z O N G U I D E D W A V E R A D A R

Two-Wire Programmable Transmitter for:

Fisher 646 Electro-Pneumatic Transducers

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Fisher 646 Electro Pneumatic Transducer

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

ECHOTEL CONTACT ULTRASOUND. Worldwide Level and Flow Solutions SM

Level Measurement Continuous level measurement Radar transmitters

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Magnetostrictive Level Transmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Proximity Transmitters and Seismic Vibration Transmitters

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Model R82 Pulse Burst Radar Level Transmitter

MEAS CAL ALARM CONF APT2000 TC

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

CSIS CAPACITANCE TRANSMITTER. Intrinsically-Safe Continuous Output Level Transmitter INSTALLATION AND OPERATIONS MANUAL

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

CS02 CAPACITANCE TRANSMITTER. Continuous Output Transmitter with Advanced Features INSTALLATION AND OPERATIONS MANUAL

Coriolis Massflowmeter

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

2-Wire Toroidal Conductivity Transmitters Series APT2000 Specifications

Process display RIA 261

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

Level Lance Model 5100

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

2-wire level transmitter

Rod probe With coaxial tube reference probe

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Fisher 4200 Series Electronic Position Transmitters

Level Measurement Continuous level measurement Radar transmitters

Operating Principles

Coriolis Massflowmeter

Magnetostrictive Level Transmitter

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

All TXI7850 products are ROHS compliant.

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Certificate of Compliance

American Power Design, Inc.

STT 3000 Smart Temperature Transmitter

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

Humidity Sensor/Transmitter Assembly

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Wireless Base Radio. Wireless Transmitters

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Instruction Manual IUC-7X-RTX. X=1: Deg. F. X=2: Deg. F. X=3: Deg. F. X=7: X=1: 1-5 ma X=2: 4-20 ma X=3: 0-1 ma X=7:

Non-Spring Return DuraDrive Modulating Actuator

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

Transcription:

Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art surface mount technology in an encapsulated (potted) module for a stable, accurate measurement in a wide range of materials. FEATURES 4 20 ma isolated output signal (reversed 20 4 ma output optional) Utilizes a 24 VDC current loop for power source and signal transmission 120/240 VAC option available for four-wire applications Minimum span 50 pf Maximum span 4000 pf Integral metering points to allow the local measurement of 4 20 ma loop current without breaking the two-wire circuit loop Power indicator LED varies in brightness with level changes ±0.25% repeatability FM, CSA, and ATEX listed intrinsically safe when used in conjunction with an approved barrier CSA explosion proof designs Available with a full range of rigid and flexible sensing probes to 5000 psig (345 bar) and +1000 F (+538 C) Input voltage of 14 to 40 VDC at transmitter terminals Two-wire, integrally mounted units meet CE requirements for RFI/EMI noise immunity APPLICATIONS Continuous level monitoring Liquid-liquid interface level measurement Clean or dirty liquids Viscous liquids Light slurries High temperature liquids Hydrocarbons & solvents Acids & corrosive liquids Food & beverage

TECHNOLOGY The amount of capacitance developed in any vessel is determined by the size (surface area) of the probe, the distance from the probe to its ground reference (e.g. tank wall), and the dielectric of the medium being measured. If the probe s position is fixed and the dielectric value of the medium is constant, then the amount of capacitance developed becomes dependent on the media in contact with the probe. As media rises and falls in the tank, the amount of capacitance developed between the sensing probe and the ground also rises and falls. This change in capacitance is converted into a proportional 4 20 ma output signal. ELECTRICAL SPECIFICATIONS Supply Voltage 24 VDC, (14 40 VDC) 120/240 VAC, 50 60 Hz, (+10/-15%) Current 38 ma maximum Line Variation Less than ±.10%/volt, for voltages between 14 40 VDC Ambient Temperature -40 to +160 F (-40 to +70 C) ➀ Zero Range 1000 pf (max.), 0 pf (min.) Span Range 4000 pf (max.), 50 pf (min.) Output Linearity 50 500 pf ±1% of span 501 1500 pf ±2% of span 1501 4000 pf ±1% of span Response Time Less than 0.1 second Repeatability ±0.25% Temperature Coefficient of Output 4000 pf span: Less than 0.035%/ F (0.063%/ C) -40 to +160 F (-40 to +70 C) 1000 pf span: Less than 0.025%/ F (0.045%/ C) 50 pf span: Less than 0.075%/ F (0.135%/ C) ➀ Consult factory for higher temperatures on remote mounted transmitter 2

MODEL NUMBER STANDARD PRESSURE Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP) BASIC 082 82 CE transmitter HOUSING 8 FM/CSA/CENELEC EEx ia, aluminum 3 4" NPT dual conduit FUNCTION/INPUT POWER 0 Four-wire, 120 VAC ➀ 1 Four-wire, 240 VAC ➀ 3 Two-wire, 24 VDC Nominal (14 to 40 VDC), FM, CSA 4 Two-wire, 24 VDC Nominal (14 to 40 VDC), ATEX Intrinsically Safe METER 0 None 1 Analog meter (Not FM/CSA approved) OUTPUT SIGNAL 3 Standard 4 20 ma 4 Reversed 20 4 ma ➁ ➂ (Not CSA approved) MOUNTING CONFIGURATION 00 Integral, NEMA 4X/7/9 aluminum housing 04 Integral, NEMA 4X/7/9 316 stainless steel housing ➂ ➅ 10 Remote, NEMA 4X/7/9 aluminum housing ➃ ➄ 14 Remote, NEMA 4X/7/9 316 stainless steel housing ➂ ➃ ➄ ➅ PROBE ASSEMBLIES ➆ A full range of rigid and flexible probes for conductive and non-conductive process media is available. For further information on probe assemblies, please refer to bulletin 50-125. ➀ Not available with codes 04 and 14. ➁ Consult factory on reversed output model. ➂ Not available with function/input power codes 0 and 1. ➃ Remote units supplied with separate probe and transmitter housing, 20 feet (6 meters) of cable and transmitter housing bracket. ➄ Remote units up to 40 feet (12 meters) with special cable, order cable part number 009-8222-001. ➅ Not available with Meter option code 1. ➆ Delivery is ESP only if Model 082 and probe selected are both ESP. 0 8 2 4 3

DIMENSIONAL SPECIFICATIONS INCHES (mm) 12.65 (321) 2.75 (70) 1" NPT Integral Mount with Rigid Probe Integral Mount with Rigid Probe and Meter anchor assembly P/N 032-8814-001 2 4.54 (115) 4.38 (111) 4.87 (124) 2.95 (75) 3/4" NPT 2 Probe diameter.1875 (5).2500 (6) 2 Holes.38 (10) 2.37 (60) 4.76 (121) 2.00 (51) 3.50 (89) Bracket Front View 6.68 (170) 3.75 (95) Side View 2.75 (70) 3/4" NPT 5.50 (141).75 (19) weight P/N 032-8814-001 1.25 (32) Remote Mount with Rigid Probe Integral Mount with Flexible Probe (120 VAC or 240 VAC Four-Wire) 2.00 (51) 2 Holes.38 (10) 2.37 (60) 4.76 (121) 3.50 (89) Bracket Front View 3.75 (95) Side View 14.08 (358) 10.33 (262) 1" NPT 2.75 (70) Remote Mount with Rigid Probe and Meter 4

AGENCY APPROVALS AGENCY APPROVED MODEL PROTECTION METHOD AREA CLASSIFICATION FM 082-8303-400 Intrinsically Safe Class I, Div 1, Groups A, B, C & D; 082-8303-410 Class II, Div 1, Groups E, F & G; 082-8304-400 Class III, NEMA 4X 082-8304-410 Non-Incendive Class I, Div 2, Groups A, B, C & D Suitable for: Class II, Div 2, Groups F & G; Class III CSA 082-8303-400 Intrinsically Safe ➀ Class I, Div 1, Groups A, B, C & D; 082-8303-410 Class II, Div 1, Groups E, F & G; Class III, TYPE 4X Suitable for: Class I, Div 2, Groups A, B, C & D; Class II, Div 2, Groups F & G; Class III 082-8303-400 Explosion Proof ➁ Class I, Div 1, Groups C & D; 082-8303-410 Class II, Div 1, Groups E, F & G Class III, TYPE 4X ATEX 082-84XX-4XX II 1G EEx ia IIC T6 ➀ Not I.S. (CSA) for Groups E & F when used with a bare probe. ➁ Approval is valid only with the use of insulated rigid probes. These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. MAXIMUM LOOP RESISTANCE (Ohms) (Including Barrier Resistance) 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 Loop Resistance vs. Power Supply Voltage 500 ohms at 24V 0 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Power Supply Voltage (Volts) 1300 ohms @ 40V Electrical data 5

QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. ESP Expedite Ship Plan Several Model 82 CE transmitter models are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, match the color coded model number codes in the selection charts (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. WARRANTY All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. 5300 Belmont Road Downers Grove, Illinois 60515-4499 630-969-4000 Fax 630-969-9489 www.magnetrol.com 145 Jardin Drive, Units 1 & 2 Concord, Ontario Canada L4K 1X7 905-738-9600 Fax 905-738-1306 Heikenstraat 6 B 9240 Zele, Belgium 052 45.11.11 Telex 25944 Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. Burgess Hill, Sussex RH15 9TL U.K. 01444-871313 Fax 01444-871317 Copyright 2004 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International. Performance specifications are effective with date of issue and are subject to change without notice. The brand and product names contained within this document are trademarks or registered trademarks of their respective holders. BULLETIN: 50-123.18 EFFECTIVE: January 2004 SUPERSEDES : December 2001