Lines, plugs and sockets for ph, redox, conductivity and temperature sensors

Similar documents
JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Condumax CLS21D/CLS21

1000TR. Instructions

Technical Information Condumax CLS15D/CLS15

Condumax CLS21 and CLS21D

USi Product Presentation. Mayser Ultrasonic Industrial Sensor USi

Absolute Encoders Singleturn

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS15 and CLS15D

Condumax CLS21 and CLS21D

Condumax W CLS15 and CLS15D

Rotary Measuring Technology

Technical data. General specifications. Transducer frequency Indicators/operating means

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Condumax CLS15 and CLS15D

ph or ORP Transmitter

Technical data. General specifications. Transducer frequency Indicators/operating means

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Condumax W CLS15 and CLS15D

Datasheet. Datasheet-No Type: GAN LU. Page: 1 of 9

Absolute Encoders Multiturn

B Operating Instructions V1.00/EN/

Absolute Encoders - Singleturn

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Absolute Encoders - Singleturn

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

XXXX e. X d.. X X X a

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Getting Started with OGS100. OrigaLys. Electr Chem

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

High-quality pressure transmitter For general industrial applications Model S-10

Technical Information Memosens CLS82D

B Operating Instructions /

TURCK Industrial Connectivity Products

TURCK Industrial Connectivity Products

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Conductivity sensor for hygienic applications

Pressure transmitter for general industrial applications Model A-10

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

High-quality pressure transmitter For general industrial applications Model S-20

Absolute Encoders Multiturn

SMARTPAT PH 1590 Technical Datasheet

QUICK REFERENCE. A-Size (7/8 ) powerfast. D-Size (1 3/8 ) powerfast. M16 powerfast. M23 powerfast. M40 powerfast. 3 & 4 pole 14 AWG conductors

Pressure transmitter For general industrial applications Model A-10

XXXX e. X d.. X X X a

RoHS. High shaft load capacity. Shock / vibration resistant

Screw-in resistance thermometers with plug connector

Rotary Measuring Technology

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Load Cell Accessories and Services

ENCODER. Analog Multiturn Encoder. Serie 8.M5861. Key-Features:

C10. Data sheet. Force transducer. Special features. B de

Phone: Fax: Web: -

SMARTPAT COND 1200 Technical Datasheet

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Capacitive BEROs. 6/2 Introduction. 6/4 DC 10 to 65 V. 6/6 AC 20 to 250 V

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Pressure transmitter for general industrial applications Model A-10

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Mineral-insulated resistance thermometers to EN

A-Size 7/8" powerfast Connectivity

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

ENCODER. SSI Multiturn. Series , Key-Features: Content:

Flexible AC current probes

Rotary Measurement Technology Absolute Encoders, Multiturn

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

Signal converter for electromagnetic flowmeters

NOVOSTRICTIVE Transducer up to 4250 mm touchless. Series TH1

Stripping. Contents. Stripping. Stripping Introduction C.2 C.1. Stripping and cutting tools C.4. Stripping tool C.10

D10 Demonstration Board

Installation guide 971 SmartRadar LTi

Data Sheet for Angle Sensors

Conductive Sensors 2 to 4-point level controller Type CL with potentiometer

Signal converter for electromagnetic flowmeters

JUMO Wtrans Receiver with Wireless Data Transmission

Liquisys M CPM223/253

* _1116* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Synchronous Servomotors CMP40 CMP112, CMPZ71 CMPZ100

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Sensor technologies Distance measuring sensors Series SM6. Brochure. C/ Centauro, 13 Área Empresarial Las Cubiertas Griñón (Madrid)

Temperature Sensor G1/2" Standard

Temperature Sensor G1/2" Standard

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

INFO-PTr. PT-100 Measuring Card. PT-100 Temperature Measurement. Technical Data

Electrical devices may only be mounted and connected by electrically skilled persons.

Liquisys M CPM223/253

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

Electronic Thermostat TE-1 Version according to EN

Introduction. Applications

Ultrasonic Sensors. Special-Sensors for. Automation. Level control Distance measurement Monitoring of all materials Waterproof Teach-in function

Float switch For industrial applications, plastic version Model RLS-2000

Distance sensors. System description. Distance measurement using triangulation

IBV 100/EXE 100 Interpolation and Digitizing Electronics

Transcription:

Page 1/5 Lines, plugs and sockets for ph, redox, conductivity and temperature sensors Brief description The use of electrochemical sensors for liquid analysis requires special connection lines and connectors. JUMO offers a selection of tried and tested versions for this application. They are available either as a finished preassembled connection line, as loose material by the roll or as individual plugs/sockets for self-assembly. As a general rule: The measuring lead selected between an electrochemical sensor and the transmitter/indicator/ controller should be as short as possible. Typical line lengths in this case are 5 to 10 m with high functional reliability. If longer line lengths must be selected in some cases, the technical documentation of the sensors and measuring instruments must be observed. The line between the sensor and evaluation instrument must be laid directly and without interruption (for example terminal strips) or cable extensions. ph and redox measurement Specially designed coaxial lines are used for ph and redox measurements. In these measurements direct voltages of a lower level are generated by the sensor and transferred to the evaluation instrument. These measurements, some of which are high-resistive measurements (potentiostatic measurement principle, internal resistors up to several gigaohms) are sensitive to electrical faults and radiation. Even a movement of the line can falsify measurement values in unfavorable conditions. An additional layer of insulation in JUMO coaxial line increases the insulation resistance of the line, thereby ensuring a reliable connection from the sensor to the transmitter. Other coaxial lines of the type used for antennas and computers are not suitable and could damage the sensors. This could also result in immediate failure of the sensor or reduced service life. For multiple sensors, for example with integrated temperature sensors, coax lines with individual core wires are available (Variopin, etc.). Conductive conductivity measurement Connecting cables for conductive conductivity probes as per data sheets 202922 to 202930 are also specially optimized and selected for the application. Alternating voltages of low amplitude in the range of a few Hertz to several Kilohertz are transferred. Accordingly these measuring leads are normally equipped with shielding. The shielding itself must be designed according to applicable technical rules and the relevant application. The individual core wires must be twisted for increased "twisted pair" signal reliability. Type 202990/xx-xx-xx-11 Ferrules Type 202990/xx-xx-xx-04 N connector Type 202990/xx-xx-xx-13 Shield-Kon connector Type 202990/xx-xx-xx-22 BNC connector, straight Type 202990/xx-xx-xx-23 BNC connector, angled Type 202990/11-95-xx-xx-xx with VP line socket Key features Type 202990/xx-xx-xx-90 N line socket High-quality preassembled connection lines Highest possible protection type with factory assembly Wide range of connectors/sockets and special selection Customer-specific versions on request

Page 2/5 Order details (1) Basic type 202990 Lines, plugs and sockets for ph, redox, conductivity and temperature sensors (2) Type of line 02 Line for ph and redox, Ø 5 mm, 75 C 09 Line for conductive conductivity probes, 4-core 11 VP coaxial line (3) Connection end 1 92 N line socket, 95 VP line socket, 6-pin, for lines Ø 5 mm (4) Line length for line type 02 1,5 1.5 m 3 3 m 5 5 m 10 10 m 25 25 m 50 50 m 100 100 m for line type 09 25 25 m 50 50 m for line type 11 5 5 m 10 10 m 15 15 m 20 20 m (5) Connection end 2 04 N connector 11 Ferrules 13 Shield-Kon connector 22 BNC connector, straight, for lines Ø 5 mm 23 BNC connector, angled, for lines Ø 5 mm 90 N line socket, for lines Ø 5 mm (1) (2) (3) (4) (5) Order code / - - - Order example 202990 / 02-92 - 10-00 Minimum order quantity: Plugs and sockets, 5 pieces per type, deviating and preassembled line 10 pieces per type

Page 3/5 Stock versions (delivery 3 days after receipt of order) Preassembled lines 92 02 0 N-line socket, Length 3 m: 202990/02-92-3-00 2992-2(3)-0 00082672 Length 5 m: 202990/02-92-5-00 2992-2(5)-0 00082673 Length 10 m: 202990/02-92-10-00 2992-2(10)-0 00082659 Length 25 m: 202990/02-92-25-00 2992-2(25)-0 00082660 Length 50 m: 202990/02-92-50-00 2992-2(50)-0 00303525 92 02 22 N line socket, BNC connector, straight Length 1 m: 202990/02-92-1-22 - 00328997 Leitungsart Type Old type Line end 2 92 02 13 N line socket, Shield-Kon connector Length 1,5 m: 202990/02-92-1,5-13 - 00085154 Length 5 m: 202990/02-92-5-13 - 00307298 Length 10 m: 202990/02-92-10-13 - 00082649 ø1,5 ø2

Page 4/5 Connecting cables for ph and redox electrodes and glass conductivity cells and multisensors with integrated temperature sensor; VP terminal head 95 11 11 VP (Variopin)- line socket, 6-pin VP (Variopin) coaxial line with shield +4 stranded wire and cable shield, temperature: -30 to +70, Ferrules Length 5 m: 202990/11-95-5-11 - 00372919 Length 10 m: 202990/11-95-10-11 - 00373029 Length 15 m: 202990/11-95-15-11 - 00451481 Contact assignment: (1) ph glas (2) ph reference (3) Pt100/1000 (3-wire) (4) free (5) Pt100/1000 (6) Pt100/1000 (7) Shield Lines (by the roll without plugs or sockets) Coaxial lines, Ø 5 mm for ph and redox measurements 0 02 0 Length 100 m: 202990/02-00-100-00 2990-2(100)-0 00085976 Connecting cables, Ø 5.7 mm for conductive conductivity probes (2-electrode system) 0 09 0 4 stranded wire and shield temperature: -5 to +80 PVC, grey Length 25 m: 202990/09-00-25-00 2990-9(25)-0 00303681 Length 50 m: 202990/09-00-50-00 2990-9(50)-0 00304181.7 20 5 WH BN YE GN Color coding to DIN IEC 757: BU = Blue GN = Green GN/YE = Green/Yellow GY = Grey RD = Red TR = Transparent WH = White YE = Yellow

Page 5/5 Plugs 1 (for self-assembly on coaxial line) Designation/illustration Type Old type for line type N connector 202990/00-00-000-04 2990-00-4 02 00061202 BNC connector, straight 202990/00-00-000-22 2990-00-22 02 00068842 BNC connector, angled 202990/00-00-000-23 2990-00-23 02 00064222 Sockets 1 (for self-assembly on coaxial line) Designation/illustration Type Old type for line type N line socket 202990/00-00-000-90 2991-00-0 02 00057350 1 Minimum order quantity: Plugs and sockets, 5 pieces per type, deviating and preassembled line 10 pieces per type