Coupling modes. Véronique Beauvois, Ir Copyright 2015 Véronique Beauvois, ULg

Similar documents
Power Quality Issues from an EMC Point of View

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC Test report for LED Panel Light Models , , , , ,

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Power Quality Basics. Presented by. Scott Peele PE

An Introduction to Power Quality

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Electromagnetic Compatibility

2620 Modular Measurement and Control System

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Emerging Standards for EMC Emissions & Immunity

EMC standards. Presented by: Karim Loukil & Kaïs Siala

1. Introduction to Power Quality

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

PQ Monitoring Standards

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Fundamentals of Power Quality

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 9

Power Quality Analysers

UNDERSTANDING POWER QUALITY

Harmonic control devices. ECE 528 Understanding Power Quality

Immunity Testing for the CE Mark

POWER QUALITY AND SAFETY

IEC Electrical fast transient / Burst immunity test

10 Safety earthing/grounding does not help EMC at RF

Electromagnetic Compatibility of Power Converters

Application Note # 5438

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Conventional Paper-II-2011 Part-1A

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

Components. Véronique Beauvois, Ir Copyright 2015 Véronique Beauvois, ULg

EMC in the railway environment Hans Bängtsson

EMC Test Report. Report Number: M030826

OUTLINE. Introduction. Introduction. Conducted Electromagnetic Interference in Smart Grids. Introduction. Introduction

Emicon Engineering Consultants L.L.C.

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

p. 1 p. 6 p. 22 p. 46 p. 58

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

HARMONICS CAUSES AND EFFECTS

via cable Route of signal interferences Shielding against radiation

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Trees, vegetation, buildings etc.

CE Testing Results and Explanation

Introduction to Harmonics and Power Quality

ELECTRONICS TESTING CENTER(ETC), TAIWAN

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

Test Specification for Type Approval

TEST REPORT... 1 CONTENT...

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

HEC-100RTA-48QSCA Rev A1.0

Low Frequency Measuring System

EMC of Power Converters

Power Quality in Metering

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

DISTRIBUTION SOLUTIONS. Technical Application Papers No. 25 Electromagnetic compatibility: theory and application measures in MV environments

Solution of EMI Problems from Operation of Variable-Frequency Drives

COOPERATIVE PATENT CLASSIFICATION

Inter Harmonics of Cycloconveter Excited Induction Motor and Design its Filter Circuit

EMC Overview. What is EMC? Why is it Important? Case Studies. Examples of calculations used in EMC. EMC Overview 1

Power supply CP-E 24/2.5

Tuningintobetter power quality

Converters for Cycling Machines

AP7301 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY L T P C COURSE OBJECTIVES:

Power quality as a reliability problem for electronic equipment

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

TE90 90W Single Output External Power Test & Measurement/Industrial Series

There s Gold in Those Waveforms Richard P. Bingham, Dranetz-BMI

Power supply CP-E 24/20.0

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

Insulation Test System

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

HEC-30/35LTA-33TDAA Rev A

Cable Solutions for Servo and Variable Frequency Drives (VFD)

HEC-35LTA-XXTSAA Rev A

ENERGY SAVING WITH OPTIMIZATION OF VOLTAGE AND CURRENT QUALITY

PLC-K506 Series FEATURES DESCRIPTION FEATURES

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

BIODEX MULTI- JOINT SYSTEM

08/07/2015

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Vacon Baltic Days Tallinn, Estonia

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

TE60 60W Single Output External Power Test & Measurement/Industrial Series

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

LS200 TEST DATA IEC61000 SERIES

Transcription:

Coupling modes Véronique Beauvois, Ir. 2015-2016

General problem in EMC = a trilogy Parameters Amplitude Spectrum Source (disturbing) propagation Coupling modes Victim (disturbed) lightning electrostatic discharges motors, converters etc. conducted (I / U) radiated (cables, slot, shielding defect, ) receivers sensors amplifiers µc etc.

General solution in EMC = a trilogy Source (disturbing) propagation Coupling mode Victim (disturbed) To act on the source (not always possible) To reduce the efficiency of the coupling mode = frequently only solution To act on the victim (increasing immunity reducing susceptibility) or different combined solutions Remark : reciprocity (to improve emission frequently improve also immunity)

1st step: to identify the disturbing elements Protections Ä for inter-system Ä for intra-system = source & victim inside the same system

Envelop Power supply 1 To identify the disturbing elements, the coupling paths, 2 Control/ Communication 3

Envelop Power supply 1 To add elements/components to reduce some effects 2 Control/ Communication 3

ABB Drives

Coupling modes The coupling modes between source and victim could be classified according to: Common mode Differential mode Differential mode (DM) (or symetrical) : current is on one conductor in one direction and in phase opposition on the second conductor (e.g. power supply, RS-485, CAN, USB).

Coupling modes Common Mode (CM) (or asymetrical or longitudinal) : current on both conductors in the same direction. The EM disturbances are weakly coupled in DM as conductors are nearby. On the other hand, in CM, current could be induced by an external field.

Coupling modes How to measure CM and DM? With a current clamp CM DM

Coupling modes Conversion between DM and CM Related to the parasitic impedances of different values Origin? When 2 conductors have a different impedance regarding earth (parasitic capacitors) If Z A =Z B, there is no voltage accross R L due to I CM If Z A Z B, V charge(cm) = I CM.(Z A -Z B )

Coupling modes A. Common impedance coupling (conducted coupling) = common conductor Considering a conductor AB, impedance Z(f) ( 0) : i p Solutions: to decrease Z (coupling) to decrease i p (source)

Coupling modes A. Common impedance coupling (conducted coupling) = common conductor

Coupling modes A. Common impedance coupling (conducted coupling) = common conductor

Coupling modes B. Inductive Coupling The circulation of a current in a conductor creates a magnetic field, which could couple with a nearby circuit, and induced a voltage. Solutions: source: to decrease db/dt victim: to decrease S or modify orientation (n and B perpendicular, B // loop) coupling: to increase distance or add a magnetic screen

Coupling modes External disturbance B. Inductive Coupling To reduce S loop

Coupling modes B. Inductive Coupling Inductive diaphony Δi s > B > i p V=L 2 di 2 /dt+mdi 1 /dt

Coupling modes B. Inductive Coupling V N = - M x di L /dt

C. Capacitive Coupling du/dt > E electric field could couple with a nearby conductor and generate a voltage Solutions: source: to reduce du/dt coupling: to increase distance Coupling modes

Coupling modes C. Capacitive Coupling Capacitive diaphony

Coupling modes C. Capacitive Coupling V = C C x dv L /dt x (Z in // R S ) Impedance of victim circuit to ground

Coupling modes Input impedance? Electric coupling increases with Z IN growing whereas magnetic coupling decreases. For the same reason, magnetic coupling is related to circuits with low input impedance as electric coupling to high input impedance.

Coupling modes Relationship distance - L and C

Coupling modes D. Radiated Coupling H-field (field to loop) E-field (field to conductor)

Coupling modes D. Radiated Coupling 1. Electromagnetic field of short electric dipole Conductor length l with a current Io l <<< λ of the field So Io is constant on l

1. Electromagnetic field of short electric dipole Electromagnetic fields (in spherical coordinates) is evaluated at an observation point P at a distance r from the origin:

1. Electromagnetic field of short electric dipole We have to consider 3 cases: - r >> λ/(2π) or kr >> 1 far-field - r << λ/(2π) or kr << 1 near-field - r λ/(2π) or kr 1 intermediate zone

1. Electromagnetic field of short electric dipole Far-field For θ=0, no electromagnetic wave, consider θ=90 (maximum of radiation): Caracteristic Impedance

1. Electromagnetic field of short electric dipole Near-field Caracteristic Impedance

1. Electromagnetic field of short electric dipole

Coupling modes D. Radiated Coupling 2. Electromagnetic field of magnetic dipole Consider a loop with Io

2. Electromagnetic field of magnetic dipole Electromagnetic fields (in spherical coordinates):

2. Electromagnetic field of magnetic dipole Far-field (r >> λ/(2π) ) For θ=90 : Caracteristic Impedance

2. Electromagnetic field of magnetic dipole Near-field (r << λ/(2π) ) Caracteristic Impedance

2. Electromagnetic field of magnetic dipole

D. Radiated Coupling Wave impedance of electromagnetic field E/H is called wave impedance. It is an important parameter as it determines the couplign efficiency ot this wave with a structure, and the efficiency of a shielding structure. In far-field (r>>λ/2π), plane wave, E and H are decreasing in the same proportion with distance. Z is a constant and in air 377Ω. In near-field (r<<λ/2π), Z is determined by the characteristics of the source.

D. Radiated Coupling

D. Radiated Coupling Far-field near-field Rayleigh criterion This criterion is related to the radiating diagram of an antenna, too large to be considered as a ponctual source. To consider a far-field condition as acceptable, it is needed that the phase shift of the components of the radiated field from the 2 ends of the antenna is small, regarding λ. We have a criterion related to λ and maximum dimension D of antenna: d > 2D²/λ

Disturbances and Power Quality Véronique Beauvois, Ir. 2015-2016

Definition of a disturbance An electromagnetic phenomenon susceptible to degrade the performances of an apparatus or system. Groupe Schneider

Types of disturbances - Classification frequency: L.F. / H.F. conducted / radiated narrowband / broadband duration (t): permanent, repetitive, transient, random common mode/differential mode

Types of disturbances - Classification Frequency: L.F. / H.F. 0 f 1 MHz conducted f > 30MHz radiated

Types of disturbances - Classification Conducted Voltage/current Radiated Electric/Magnetic fields

Types of disturbances - Classification Narrowband (disturbance bandwidth < receiver s one) Broadband (disturbance bandwidth > receiver s one)

Types of disturbances - Classification Common Mode Differential Mode

Types of disturbances L.F. & conducted >> Power Quality 3-phase systems Parameters? frequency (50 Hz) amplitude (V) waveshape (sinusoidal) symetry (phase shift 120 )

1. Frequency Deviation Types of disturbances Frequency variations are very small (less than 1 %) in the European network (mesh). Consequently, very few problems for electronic equipement. In a small isolated network (e.g. island or emergency power system), the situation is different. Some process need a very precise control of speed and frequency variation could disturb. 47

Types of disturbances 2. Amplitude 2.1 Voltage dips and short interruptions Voltage dips could be related to short-circuit in the network or at the customer premises (defaults, atmospheric problems, ). In this case only drop of voltages more than 10 % are considered (otherwise they are voltage fluctuations). Definition of voltage dip [EN 50160] : quick reduction of power supply at a value between 90 and 1 % of the nominal voltage, followed by a recovering very soon. Duration from 10 ms to 1 min., by definition. Short interruptions [EN 50160] : reduction of power supply under 1 % of the nominal voltage. Short : less than 3 minutes. Consequences : some equipment could stop, if the depth and duration are over certain limits (according to the sensitivity of the load). U(t) Urms Uref Uref-10% Δ U Δ t Voltage dip Short interruption 48

Types of disturbances 2. Amplitude 2.1 Voltage fluctuations / Flicker In some installations, quick variations of power (produced or consumed) could be observed (welding, wind turbines, arc furnaces, air conditioning, ). This could lead to voltage variations. Flicker [EN 50160] : visible change in brightness of a lamp due to rapid fluctuations in the voltage of the power supply. The voltage drop is generated over the source impedance of the grid by the changing load current of an equipment (frequent starting of an elevator motor, air conditioning systems, arc furnaces, welding machines, ). Effects in the band 0.5-25Hz. Major consequences on lamps. Standards EN 61000-3-3 (I < 16A) EN 61000-3-11 (16A < I < 75A) 49

Types of disturbances 3. Waveshape 3.1 Harmonics / Interharmonics Harmonics: components of frequencies which are multiple of fundamental (50Hz) and create a distortion of the sinusoidal waveshape. Interharmonics: components which are non integer multiples of fundamentals (very rare, arc furnaces, static frequency converters for low speed applications and cycloconverters, e.g. cement crushers). K.f m +/- k.f o (f m is mains frequency and f o for output frequency). 50

Harmonics We have seen that a periodic signal could be represented by a sum of sinus with different amplitudes and phases, with frequency multiple integer of fundamental (frequency f). Harmonics.

Harmonics Origin? All non linear loads are associated with a non sinusoidal current and generates harmonics Sources? inverters, choppers, dc-dc converters rectifiers speed controllers frequency converters dimmers lighting Induction heating systems Saturated magnetic circuits

Harmonics Consequences? Heating (motors, transformers, cables, ) Losses (transformers) Saturation (transformers) Additional torque components (motors) Resonance (Q compensation capacitors) Homopolar compenents (H3) Defaults (power electronics, IT, relays, controlers, )

Types of disturbances 3. Waveshape 3.2 Transient Overvoltages: related to the release of low voltage apparatus, inductive loads, capacitor banks start (Q compensation) and fuse fusion. Sinusoidal damped overvoltages: some actions on the medium voltage network as a breaker opening or closing, switches disconnection, may cause a voltage variation which excites the line with a very short pulse with a short rise time. The consequence is a damped sinus. 54

Types of disturbances 3. Waveshape 3.2 Transient Burst 0 200MHz 55

Types of disturbances 3. Waveshape 3.2 Transient Surge 4kV Normalized waveshape Voltage 1,2/50µs Current 8/20µs 0 100MHz 56

4. Symmetry / Unbalance Dissymmetry in the network are very small. Types of disturbances The main problem is the one-phase loading in a 3-phase network, and the repartition of those loads. Consequences: additional heating and flickering problems. 57

Types of disturbances DEFINITION OF POWER QUALITY (PQ) Power Quality = Voltage Continuity + Voltage Quality Voltage Continuity (Reliability of Supply) - long interruptions Voltage Quality frequency - deviations magnitude - deviations - dips & short interruptions - flicker waveform - (inter)harmonics symmetry - unbalance 58

Power Quality - Examples Véronique Beauvois, Ir. 2015-2016

A. Harmonics Neutral and cables diameter One of the major effects due to harmonics is the increasing of RMS currents in the mains. Harmonic 3 in phase Ø Sum is not zero Ø Sum in neutral : 3 x Iphase Ø Heating Ø Destruction risk Ø Diameter of cabling should be adapted (same for 3k multiples) 60

A. Harmonics Neutral and cables diameter Distorsion rate I1 225A I3 183A 81.3 % I5 152A 67.6 % I7 118A 52.4 % Iph = 348A (1.55 x I1) (RMS of harmonics) In = 3 x 183A = 549A (2.44 x I1) Phases: 225A > 70mm² with Hn 150mm² (385A) Neutral > 35mm² with Hn 300mm² (615A) Based on R.G.I.E. 61

B. Eco light 62

B. Eco light 63

C. LED 64

D. Generators Renewable Energy 65