Medium Voltage Drives in Industrial Applications. By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON

Similar documents
PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer

Frequently Asked Questions (FAQs) MV1000 Drive

Part Five. High-Power ac Drives

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

MV VFD Discussion MIA Detroit 2016

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

VARIABLE FREQUENCY DRIVE

IEEE-ICIT 2010 CHILE A New Medium Voltage Drive System Based on ANPC-5L Technology

TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

CHAPTER 1 INTRODUCTION

Medium Voltage AC Drives Selection Guide PowerFlex 7000 Direct-to-Drive Technology Air-Cooled Liquid-Cooled

A Single-Phase Cascaded Multilevel Inverter Based on a New Basic Unit with Reduced Number of Power Switches

Comparison of Hybrid Asymmetric and Conventional Multilevel Inverters for Medium Voltage Drive Applications

Reliability Starts Here. PowerFlex TM 7000 Family of MV Drives

Fundamentals & Application of Medium Voltage Adjustable Speed Drives (ASD)

Design of Five-Level Bidirectional Hybrid Inverter for High-Power Applications

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

Meduim Voltage Drives

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

Literature Review. Chapter 2

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

Switches And Antiparallel Diodes

International Journal of Advance Engineering and Research Development

Matrix Drives Boost Power Quality and Energy Savings

Modern Concepts of Energy Control Technology through VVVF Propulsion Drive

5-Level Parallel Current Source Inverter for High Power Application with DC Current Balance Control

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

AMV-I Medium Voltage Inverter Manual

Development of Transformerless Multi-Level Medium Voltage Inverters

Type of loads Active load torque: - Passive load torque :-

6. Explain control characteristics of GTO, MCT, SITH with the help of waveforms and circuit diagrams.

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

Power Electronics (BEG335EC )

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation

11. Define the term pinch off voltage of MOSFET. (May/June 2012)

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Industrial Electronics

VFDs and Harmonics in HVAC Applications

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Medium Voltage VFD MVC Series. 200kW to 40MW 2.3kV to 18kV

Matrix Technology for next generation Variable Speed Electric Motor Control

Fundamentals of Power Electronics

Mr. DILIP J. Final Year Mtech Student Dept of EEE The Oxford College of Engineering, Bangalore

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

HIGH-POWER CONVERTERS AND AC DRIVES

Large PWM Inverters for Rolling Mills

Low Pass Harmonic Filters

A Highly Versatile Laboratory Setup for Teaching Basics of Power Electronics in Industry Related Form

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

POWER ISIPO 29 ISIPO 27

Lecture 19 - Single-phase square-wave inverter

Transformer-less PWM High Power Medium Voltage Variable Speed Drive

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

Introduction to HVDC VSC HVDC

ECEN 613. Rectifier & Inverter Circuits

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota

ECET Industrial Motor Control. Variable Frequency Drives. Electronic Motor Drives

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLY Mamallapuram chennai

1. INTRODUCTION 1.1 MOTIVATION AND OBJECTIVES

Multilevel Technology with ALSPA VDM6000

CHAPTER 4 FULL WAVE RECTIFIER. AC DC Conversion

A Power Electronics based Transformer design and its Optimization to reduce the losses

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

COOPERATIVE PATENT CLASSIFICATION

New Approaches for Harmonic Reduction Using Cascaded H- Bridge and Level Modules

How adjustable speed drives affect power distribution

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

Speed Control of Induction Motor using Multilevel Inverter

Application Note. Applicable Product: AC Drives

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Multi-Level Inverters

COMPARISON OF POWER QUALITY SOLUTIONS USING ACTIVE AND PASSIVE RECTIFICATION FOR MORE ELECTRIC AIRCRAFT

Harmonics White Paper

Multi-Level Inverters

Univerter-MV. Medium Voltage Variable Speed Drive

Power Supplies in Accelerators

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Understanding Input Harmonics and Techniques to Mitigate Them

MODELING AND SIMULATION OF Z- SOURCE INVERTER

High Voltage DC Transmission 2

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

ELG3336: Power Electronics Systems Objective To Realize and Design Various Power Supplies and Motor Drives!

Conventional Paper-II-2013

Design and Simulation of Passive Filter

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar.

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Performance Analysis of The Simple Low Cost Buck-Boost Ac-Ac Converter

A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES

LARGE ac-drive applications have resulted in various

Power Electronics. Contents

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

Transcription:

Medium Voltage Drives in Industrial Applications By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON

Outline Introduction Medium Voltage Drive Topologies A Brief Comparison Power Semiconductors Influence of the Semiconductor on Drives Influence of Topology on Power System A Hypothetical Drive for the Future Conclusion 2

Medium Voltage Drive Introduction ac mains rectifier dc link inverter ac motor Voltage range 1 kv 2. kv. kv 4.16 kv 6.6 kv 11 kv 15 kv Power Range 0.2 MW 0.5 MW 1 MW 2 MW 4 MW 8 MW 12 MW

Target Industries / Applications Petrochemical Pipeline pumps Gas compressors Brine pumps Mixers / extruders Electrical submersible pumps Induced Draft Fans Boiler feed water pumps Cement Kiln induced draft fans Forced draft fans Cooler baghouse fans Preheat tower fans Raw mill induced draft fans Kiln gas fans Cooler exhaust fans Seperator fans Baghouse fans Forest Products Fan pumps Induced draft fans Boiler feed water pumps Pulpers Refiners Kiln drives Line shafts Water / Waste Water Raw sewage pumps Bioroughing tower pumps Treatment pumps Freshwater pumps Miscellaneous Test stands Wind tunnels Agitators Rubber mixers Mining & Metals Slurry pumps Ventilation fans Descaling pumps Conveyors Baghouse fans Cyclone feed pumps Electric Power Feed water pumps Induced draft fans Forced draft fans Baghouse fans Effluent pumps Compressors 4

Medium Voltage Basic Topologies M M Current Source Inverter Voltage Source Inverter 5

Medium Voltage Topology Summary MV Industrial Drives Series connection of LV Modules HV Devices Cascaded HBridge Current Source PWM Rectifier PWM CSI 12/18P PWM CSI Voltage Source 2 Level Level (NPC) 5 Level 6

Current Source Inverter M Inverter GCT based PWM Rectifier (AFE) GCT based 6, 12, 18, or 24 pulse phase controlled thyristor Converter voltage capability increased by placing devices in series 7

2 Level Voltage Inverter M Inverter IGBT based 6, 12, 18, or 24 pulse diode rectifier PWM Rectifier (AFE) Converter voltage capability increased by placing devices in series 8

Level Voltage Inverter Inverter GCT or IGBT based 12, or 24 pulse diode rectifiers PWM Rectifier (AFE) with GCTs or IGBTs Converter voltage capability is 4.16 kv. For greater voltage series devices are required doubling number of devices in the inverter M M 9

Cascaded H Bridge with LV IGBTs Inverter LV IGBT based Diode 6 pulse rectifiers fed from a minimum of 9 windings HBridge 11 HBridge 12 Converter voltage capability is increased by adding a set of secondary windings and HBridge modules HBridge 21 HBridge 22 HBridge 1 HBridge 2 HBridge 1 HBridge 2 HBridge M 10

Cascaded H Bridge with HV IGBTs Inverter HV IGBT based Diode 6 pulse rectifiers fed from a minimum of 12 windings Converter voltage capability is increased by greater secondary winding voltage and higher voltage Diodes & IGBTs M 11

Medium Voltage Topology Summary MV Industrial Drives Series connection of LV Modules HV Devices Cascaded HBridge Current Source PWM Rectifier PWM CSI 12/18P PWM CSI Voltage Source 2 Level Level (NPC) 5 Level Indicates the technology is still evolving! 12

Performance Comparison Load Types 18% Constant Torque Medium Performance <10 rad/sec 2% High Performance <50 rad/sec Speed Regulation Open Loop 80% Variable Torque Low Performance < 5 rad/sec Typical Performance Criteria Values Close loop Speed Regulator Bandwidth Speed Range VFD Efficiency CSIPWMGTO 0.5% 0.1% < 10 rad/s 075 Hz >97 Inherent CSIPWMSGCT 0.5% <0.1% < 20 rad/s 075 Hz >97 Inherent Regeneration LevelIGCT 0.5% 0.01% Approx. 50 rad/s 066Hz >97 With PWM rectifier LevelIGBT 0.5% 0.01% Approx. 50 rad/s 150Hz at 4 kv 66 Hz at 6.6 kv >97 With PWM rectifier Series HBridge 0.5% 0.1% Unknown 0120 Hz >97 Not available 1

Component Count Numerous reasons for reduction in complexity of system and component count general increase in reliability possibly reduce the number of spare parts required possibly eliminate the need for costly entire cell replacement Ideally reduce complexity with the elimination of the multi winding transformer presently only the PWMCSI is known to achieve this 14

Component Count Rectifier Component Count for Transformerless 4160 V, 750kW drive IEEE5191992 PWMCSISGCT 2Level IGBT Level IGCT Level IGBT GTO Not Available Not Available Not Available Not Available Series H Bridge Not Available PWMCSI Rectifier Semi 12 6.5 kv Conductors SGCTs Rectifier Snubber 12 RC 15

Component Count Cont d Transformer Rectifier Semi Conductors Rectifier Snubber Rectifier Component Count for 4160 V, 750kW drive with isolation transformer meeting IEEE5191992 Isc/Il<20 PWMCSIGTO 18p PWMCSISGCT 18p 2Level IGBT 18p Level IGCT 24p Level IGBT 24p Series H Bridge 24p 1 primary 1 primary 1 primary 1 primary 1 primary 1 primary secondaries secondaries secondaries 4 secondaries 4 secondaries 12 secondaries 18 thyristors 18 thyristors 18 diodes 24 diodes 24 diodes 72 diodes 18 RC 18 RC Not required Not required Not required Not required 16

Component Count Cont d Charging circuitry DC link PWMCSI GTO 18p DC Link & Inverter Component Count for 4160 V, 750kW PWMCSISGCT 18p 2Level IGBT 18p Level IGCT 24 p Level IGBT 24p Series H Bridge Not required Not required 1 1 1 1 per cell 1, 0.6 per unit inductor 1, 0.4 per unit inductor Oil Film, 4 0.5pu DC link Voltage sharing networks Not Required Not Required Internal to capacitors DC Link Fusing Not required Not required Normally not required Inverter 126500 V 12 6500 V 2400 V Semiconductors GTOs SGCTs IGBTs Neutral Point Not Clamping Required network Snubber for inverter Output filter 24p Oil Film, 40.5pu Oil Film, 4 0.5pu 180 electrolytic capacitors @ 600uF Internal to Internal to 6 sharing capacitors capacitors resistors Yes or Normally not Normally not IGCTs required required 125500V 2400 V 481400V IGCTs IGBTs Not Required Not Required 6diodes 6diodes or 1200 V IGBTs 12RCD 12RC Not Required Clamp snubber May not be required depends on layout 0.40.6 per unit capacitor 0.250.5 per unit capacitor LC output filter (fres=5 6pu) LC output filter (fres=78pu) LC output filter (fres=78pu) L =0.1 pu L=0.1 pu L=0.1pu C= 0. pu C=0.2 pu C=0.2pu IGBTs Not Required Not Required Not Implemented 17

Loss & Efficiency Estimation System efficiency greatly affected by : semiconductor, control algorithms, fsw, selection of passive components Literature has numerous comparisons between the IGBT and IGCT All manufactures indicate a drive efficiency of >97% some do not include ancillary components fans, power supplies, etc.. Which manufacturer is more correct? difficult and challenging question for the end user to answer 18

19 Simulation Results for Input Power Factor vs Load Power for Different Rectifier Options (Variable Torque Load)

Power System Impact Input Harmonic Performance line current harmonics and THD 0.0% 25.0% 20.0% 15.0% % harmonics PWMR 10.0% 24P 18P 5.0% 12P 0.0% 6P topology 6P 12P 18P 24P PWMR 5th 7th 11th 1th 17th 19th 2rd 25th 29th 1st rd 5th THD harmonics order 20

Output Impact Motor Voltage and Current Harmonics SGCTCSI GTOCSI Hbridge VSI LVSI with filter THDI THDV LVSI without filter 2LVSI with filter 0.0% 10.0% 20.0% 0.0% 40.0% 21

Power Semiconductor Devices in MV Drives Wide variety of devices are used Low voltage devices IGBTs up to 1700 V High voltage devices. kv to 6.5 kv GCTs (symmetric, asymmetric, reverse conducting) IGBTs State of the art IGBTs 6500 V, 600 A State of the art GCT 6500 V, 6000A 10 kv devices have been demonstrated New device technology (e.g. SiC ) would have a significant impact in consolidating the offerings or perhaps enabling a new MV topology Device technology has yet to force a standard topology as in low voltage drives. 22

Symmetrical Gate Commutated Thyristor (SGCT) Modified GTO with integrated gate drive Gate drive close to the device creates low inductance path more efficient and uniform gating Low conduction & switching losses Low failure rate 100 failures per billion hours operation Double sided cooling Non rupture failure mode 2

Houses main power components Compact, modular package Common design for rectifier & inverter modules Patented* Power Cage 24

25 4160 Volt PWM Rectifier

Conclusions There is a diverse approach by industry Each of the topologies presented meet the performance requirements of a majority of the applications in industry Higher voltage semiconductors inherently reduce overall component count and system complexity can eliminate the isolation transformer on CSI PWM rectifiers Higher voltage semiconductor costs have an advantage over low voltage devices. The (S)(I)GCT technology is presently very cost effective IEEE519 can be met with 18, 24, and PWM rectifiers The power factor for CSI PWM rectifiers can be held close to unity throughout the load range 26

A Medium Voltage Drive for the Future What should we expect from this future drive? Competitive pricing Greater ease of installation, operation and maintenance Greater reliability We should expect to continue to see (for the next to 5 years) MV drives with standard stages of rectification, DC energy storage and inversion It is unlikely that a different methodology will displace the traditional approach used today ac mains rectifier dc link inverter ac motor We must strive for greater simplicity and functionality! 27

Bidirectional device Possible Alternative Device Using RBIGBT technology can lead to the matrix converter e a L1 Va e a L2 C12 C1 Vb M e a L Vc Clamp Circuit It remains to be seen if this is commercially viable at low voltage! 28

The Drive Layout Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface Input Rectifier DC Link Inverter Output cables in Standard cables Line current/ voltage meet standards/ guidelines Active rectifier Control power factor to near unity Provide active damping/clamping for oscillations/ transients Regenerative 6device structure Line impedance, not necessarily transformer Single to few components designed for the life of drive Optimize/ minimize stage Active Inverter Provide low THD to motor Provide damping/clamping for oscillations/transients 6 device structure Mitigate neutral to ground voltage cables out Standard cables Motor current/voltage facilitate standard motor design Cable length limited only due to voltage drop 29

Input Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface 0 cables in to drive Cables are to be standard Line current/voltage meet harmonic standard/guide lines Input impedance should be minimal with out the need to isolate the drive from the power system (no transformer)

Rectifier Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface 1 Active line converter providing: Harmonic mitigation Power factor near unity through the load range Capable of damping/clamping any system oscillation or transient Regeneration 6 device line converter for voltages in the 4.16 kv to 6.6 kv Device would be selfpowered identical to that used in the inverter

DC Link Energy Storage Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface Consist of a single to a few parts designed for life of the drive system No snubber or clamp assisting the operation of the converter devices 2

Inverter Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface 6 device machine converter for voltages in the 4.16 kv to 6.6 kv Device would be selfpowered identical to that used in the rectifier Output voltage and current would be near sinusoidal eliminating issues with dv/dt, and wave reflection due to cable length Actively damp / clamp oscillations or transients Mitigate neutral to ground voltage concerns on the motor

Output Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface cables from the output of the drive to the motor The output voltage/current waveforms allow for the use of standard motor designs Cable length from drive to the motor is unlimited 4

Motor Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface 5 The inverter waveform quality would result in no need for: Inverter duty designs Added insulation due to neutral to ground offset voltage Derating of existing standard machines while running on MV drives

Control Medium Voltage Phase Supply MV Drive System/Structure for the Future 5 years out 2007 2010 + Z 0 fsw ~ Z 0 fsw MOTOR Self powered gating with isolation Device Tj Device Tj Self powered gating with isolation Input Current Sensing Input Voltage Sensing Control prognostics Output Current Sensing Output Voltage Sensing Test Power Interface Software based algorithms characterizing systems will decline in favor of adaptive controllers making knowledge of the system less critical More prognostic capability which will reduce the potential for unexpected down time 6

Conclusion A summary of the MV topologies has been given A summary of the power semiconductors and their influence on topologies described A hypothetical drive for the near term described A significant advancement in power device technology will be the key to greater simplicity and functionality 7