SHADOWGRAPH ILLUMINIATION TECHNIQUES FOR FRAMING CAMERAS

Similar documents
DISCLAIMER. Portions of this document may be illegible. in electronic image products. Images are. produced from the best available original document.

Performance of Image Intensifiers in Radiographic Systems

Five-beam Fabry-Perot velocimeter

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

Laser Surface Profiler

Nanosecond, pulsed, frequency-modulated optical parametric oscillator

GYROTRON-BASED MILLIMETER-WAVE: BEAMS FOR MATERIAL PROCESSING. Thomas Hardek Wayne Cooke. William P e r r y D a n i e l Rees

UCRL-ID Broad-Band Characterization of the Complex Permittivity and Permeability of Materials. Carlos A. Avalle

Performance of Keck Adaptive Optics with Sodium Laser Guide Stars

Gerhard K. Ackermann and Jurgen Eichler. Holography. A Practical Approach BICENTENNIAL. WILEY-VCH Verlag GmbH & Co. KGaA

SUBJECT: PHYSICS. Use and Succeed.

Performance of Smoothing by Spectral Dispersion (SSD) with Frequency Conversion on the Beamlet Laser for the National Ignition Facility

BEAM HALO OBSERVATION BY CORONAGRAPH

DCS laser for Thomson scattering diagnostic applications

ECEN 4606, UNDERGRADUATE OPTICS LAB

Preliminary Comparison of Monolithic and Aperture Optics for XRMF. George J. Havrilla CST-8 Christopher G. Worley CST-8

OPTICS DIVISION B. School/#: Names:

The below identified patent application is available for licensing. Requests for information should be addressed to:

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

High Explosive Radio Telemetry System. Federal Manufacturing & Technologies. R. Johnson, FM&T; B. Mclaughlin, FM&T;

Sandia National Laboratories MS 1153, PO 5800, Albuquerque, NM Phone: , Fax: ,

Systems Biology. Optical Train, Köhler Illumination

Exercise 8: Interference and diffraction

TIME DEPENDENT IMAGING OF CYLINDRICAL SHOCKS AT THE PEGASUS FACILITY

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Physics 3340 Spring Fourier Optics

Chapter 23 Study Questions Name: Class:

Argonne National Laboratory P.O. Box 2528 Idaho Falls, ID

Detection of Targets in Noise and Pulse Compression Techniques

Los A LA-UR Los Alamos National Laboratory Los Alamos, New Mexico 87545

Chapter Wave Optics. MockTime.com. Ans: (d)

GA A FABRICATION OF A 35 GHz WAVEGUIDE TWT CIRCUIT USING RAPID PROTOTYPE TECHNIQUES by J.P. ANDERSON, R. OUEDRAOGO, and D.

Physics 3340 Spring 2005

Up-conversion Time Microscope Demonstrates 103x Magnification of an Ultrafast Waveforms with 300 fs Resolution. C. V. Bennett B. H.

A simple and effective first optical image processing experiment

DISCLAIMER. Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

DISCLAIMER. Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

Armlication For United States Patent For HOT CELL SHIELD PLUG EXTRACTION APPARATUS. Philip A. Knapp Moore, ID. and. Larry K. Manhart Pingree, ID

National Accelerator LaboratoryFERMILAB-TM-1966

MAPPING INDUCED POLARIZATION WITH NATURAL ELECTROMAGNETIC FIELDS FOR EXPLORATION AND RESOURCES CHARACTERIZATION BY THE MINING INDUSTRY

Stimulated Emission from Semiconductor Microcavities

Be aware that there is no universal notation for the various quantities.

Sub-nanometer Interferometry Aspheric Mirror Fabrication

GA A23281 EXTENDING DIII D NEUTRAL BEAM MODULATED OPERATIONS WITH A CAMAC BASED TOTAL ON TIME INTERLOCK

Far field intensity distributions of an OMEGA laser beam were measured with

Recent advances in ALAMO

Chapter Ray and Wave Optics

Option G 4:Diffraction

Why is There a Black Dot when Defocus = 1λ?

Parasitic Pencil Beams Caused by Lens Reflections in Laser Amplifier Chains

Quarterly Technical Progress Report. For the period starting July, , ending September 30, Xiaodi Huang and Richard Gertsch

&wf-9+/ob/--21*~~ II. Ron Harper and Robert A. Hike

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Instructions for the Experiment

GIST OF THE UNIT BASED ON DIFFERENT CONCEPTS IN THE UNIT (BRIEFLY AS POINT WISE). RAY OPTICS

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

IMAGING TECHNIQUES FOR MEASURING PARTICLE SIZE SSA AND GSV

Reflectors vs. Refractors

LEOK-3 Optics Experiment kit

PHOTOMULTIPLIER TUBE SATURATION INDICATOR. Jeffery F. Ruch P.O. Box 79 West Mifflin, PA. David J. Urban. West Mifflin, PA DISCLAIMER

In-line digital holographic interferometry

Design Description Document

U.S. Air Force Phillips hboratoq, Kirtland AFB, NM 87117, 505/ , FAX:

12:40-2:40 3:00-4:00 PM

The ACT External HEPA Push-Through Filter Assembly. A. A. Frigo, S. G. Wiedmeyer, D. E. Preuss, E. F. Bielick, and R. F. Malecha

Following the path of light: recovering and manipulating the information about an object

An Imaging White Light Velocimeter

Education in Microscopy and Digital Imaging

INITIAL RESULTS FROM THE MULTI-MEGAWATT 110 GHz ECH SYSTEM FOR THE DIII D TOKAMAK

LOS 1 LASER OPTICS SET

1 Laboratory 7: Fourier Optics

Evaluation of Roof Bolting Requirements Based on In-Mine Roof Bolter Drilling

Diffuser / Homogenizer - diffractive optics

a) How big will that physical image of the cells be your camera sensor?

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

Giovanni P. Donati - MST-11 Daniel Some - MST-11 George Rodriguez - MST-11 Antoinette J. Taylor - MST-11

Mitigation of Laser Damage Growth in Fused Silica with a Galvanometer Scanned CO2 Laser

G. D. Martin, J. R. Castrejon-Pita and I. M. Hutchings, in Proc 27th Int. Conf. on Digital Printing Technologies, NIP27, Minneapolis, MN, USA, 2011

Design of a digital holographic interferometer for the. ZaP Flow Z-Pinch

National Accelerator Laboratory

Testing Aspherics Using Two-Wavelength Holography

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

Specification of APS Corrector Magnet Power Supplies from Closed Orbit Feedback Considerations.

Use of Computer Generated Holograms for Testing Aspheric Optics

Preparation of Random Phase Plates for Laser Beam Smoothing

Chapter 36: diffraction

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

GA A26816 DESIGNS OF NEW COMPONENTS FOR ITER ECH&CD TRANSMISSION LINES

Speckle Mitigation in Laser-Based Projectors

CORRECTED RMS ERROR AND EFFECTIVE NUMBER OF BITS FOR SINEWAVE ADC TESTS

Bandpass Edge Dichroic Notch & More

Accelerator and Fusion Research Division Lawrence Berkeley Laboratory University of California Berkeley, CA 94720

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

APPLICATIONS FOR TELECENTRIC LIGHTING

Transcription:

L SHADOWGRAPH ILLUMINIATION TECHNIQUES FOR FRAMING CAMERAS R.M. Malone, R.L. Flurer, B.C. Frogget Bechtel Nevada, Los Alamos Operations, Los Alamos, New Mexico D.S. Sorenson, V.H. Holmes, A.W. Obst Los Alamos National Laboratory, Los Alamos, New Mexico Many pulse power applications in use at the Pegasus facility at the Los Alamos National Laboratory require specialized imaging techniques. Due to the short event duration times, visible images are recorded by high-speed electronic framing cameras. Framing cameras provide the advantages of high speed movies of back light experiments. These high-speed framing cameras require bright illumination sources to record images with 10 ns integration times. High-power lasers offer sufficient light for back illuminating the target assemblies; however, laser speckle noise lowers the contrast in the image. Laser speckle noise also limits the effective resolution. This discussion focuses on the use of telescopes to collect images 50 feet away. Both light field and dark field illumination techniques are compared. By adding relay lenses between the assembly target and the telescope, a high-resolution magnified image can be recorded. For dark field illumination, these relay lenses can be used to separate the object field from the illumination laser. The illumination laser can be made to focus onto the opaque secondary of a Schmidt telescope. Thus, the telescope clnly collects scattered light from the target assembly. This dark field illumination eliminates the laser speckle noise and allows high-resolution images to be lrecorded. Using the secondary of the telescope to block the illumination laser makes dark field illumination an ideal choice for the framing camera. Overview Techniques are being developed to measure particle size distributions of fast moving i ------i particles at the Pegasus facility at the Los Alamos National Laboratory1 2. A shadowgraph back lighting experiment has been fielded in conjunction with holographic and Xray diagnostics. While the hologi?amcollects a single snap shot of a 3-dimensional volume of particles, the shadowgraph diagnostic is intended to create a short movie of the particle trajectories. Because of the hazardous environment for imaging systems at Pegasus, the expensive framing camera is located 50 feet away. Figure 1 shows typical hardware used to collect optical images of the particle distributions. A long pulse ruby laser passes in and out of a vacuum chamber. Inside1the vacuum chamber, the ruby laser has to ~*~~~ WtMS Q O c U I$ ~WLflMrn TER

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency tbereof, nor any of their mployees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, proccss. or service by trade name, trademark, manufac-. turcr, or otherwise does noc necessarily constitute or imply its endorsement, mommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United!States Government or any agency thereof.

DISCLAIMER Portions of this document may be illegible electronic im{age products. Images are produced frotm the best available original document.

Ruby laser 450 usec FWHM 8J Pockels cell Load to 8 telescope = 50 feet I t- event trigger 50 mmw1.4 35 rnmfa.4 t Ceiestron /lo5 28 rnrn Vidicbn 40 mm MCP Figure 1. Pegasus hardware layout. kmf/2 lens\ 12.5 rnm objective I 4.6 pj/cm2 measurement of Ruby power

hardware space with holography,,the primary diagnostic. An 8-inch diameter telescope located 50 feet away can only resolve 37 pm particle sizes. So, the particles are magnified with a 58 mm and 600 mm lens pair. The telescope focuses on an intermediate image plane. By comparison, Figure 2a shows a simpler layout where only a telescope collects images from the high-speed particles (ejecta). Here, the interfering 58 mm lens required for the hologram recording is removed. The telescope collects both the illuminating ruby laser beam as well as the scattered light from the particles. This phenomena, called light field illuinination, suffers problems with laser speckle which is caused by random phase variations within the laser beam. The laser beam acts as multiple laser beam sources, and the different sources interfere with each other. The amount of speckle depends on the coherence length of the laser. By contrast, Figure 2b shows the 58 mm and 600 mm doublet lens pair that both relays and magnifies the image. By chimging the position of the 600 mm lens, the illuminating ruby laser footprint can be made to vary in size. If the laser beam fills the full telescope aperture, we woulcl have the light field illumination condition as shown in Figure 2a. By focusing the ruby laser onto the secondary mirror of the telescope, the laser beam cannot reach the imaige plane of the framing camera. This condition, dark field illumination, is shown in Figure 2b. mirrors Ejecta f--- 50 feet distance 4 8 Celestron telescope 19 mm objective filter- beam Figure 2a. Light Field Optical Layout. 600 mm doublet mirrors beam Figure 2b. Dark Field Optical Layout. 8 Celestron telescope 19 rnm objective

. In Figure 2b, coherent noise (speckle) in the image is eliminated because the reference beam is entirely blocked at the secondary of the telescope. Additionally, this method effectively blocks the dc component of the Fourier spectrum of the object. This performs edge enhancement on the object data collected. Experimental Data A special resolution target was used to evaluate imaging conditions. A HeNe was used as the laser source for these evailuations. For the test results shown in Figures 3a, 3b, 3c and 3d, the optical setup of Figure 2b was used. By moving the position of the 600 mm lens, either a light field or a dark field illumination condition was created. Figure 3a shows a pattern with large structures ranging from 25 pm to 100 pm. Large structures show up reasonably well despite the laser interference patterns in the background. The dark field condition shown in Figure 3b shows image reversal, a dark background with only edges of the resolution pattern showing up. Because the illuminated light is obscured by the secondary of the telescope, a high-pass filtering of the image occurs, which results in edge enhancement. The high-pass filtered image shown in Figure 3b illustrates the absence of dc (on-axis undiffracted energy), in that the larger bars are dark in the middle and have sharp edges. Figure 3c shows higher frequency information for the light field condition. The lines and dots vary from 1 pm to 10 pm. Because of the interference of speckle in the image, the limiting resolution is 8 pm. Figure 3d shows the much higher resolution obtained by using the dark field condition. Limiting resolution is 2.5 pm with much higher signal-to-noise ratios (S/N). The dots appear as bright stars against a very black background. In this higher resolution image, the centers of the dots are filled in. Dots below 25 pm in size are solid with sharp edges. Dirt on the resolution pattern and the 600 mm lens (which is close to the intermediate image plane) can be a serious pr,oblem. Dirt on optical elements near the intermediate image will severely block out part of the image. Any unwanted out of focus ejecta data will also severely block out good (data. Proper cleaning techniques are required. Depth of Focus The telescope in Figure 2a is 50 ieet away, which gives a resolution of 37 pm. At that resolution, the depth of focus is 2.8 mm. Formulas are shown in Figure 4. In the layout shown in Figure 2b, the magnified image has a reduced depth of focus. Magnification is defined by the ratio of the 2 collecting lenses. The resolution is 3.5 pm and the depth of focus is 4 pm. This is extremely short. The first collecting lens is 35 mm away. As shown in Figures 3c and 3d, laser speckle degrades the resolution from 3.5 pm to 8

pm, but the dark field condition shows diffracted imaging collection. Because the depth of focus for the dark field condition is so short, Clare must be taken to insert a calibrated wire at the image plane to find best focus. Care must be taken so that out of focus material does not obscure the data. This is done with baffles and slits to block unwanted scattering sources. Figure 4. Depth of Focus At this depth of focus, building vibrations make focusing and alignment challenging, but the event data was collected in 510 ns. Conclusion We have tried various methods of using diffusing materials to smooth out the laser speckle with very limited success. A Raman cell to broaden the laser wavelength would decrease the coherent length and reduce speckle. This was too difficult to try inside our experimental vacuum chamber. An optical imaging system has been developed to relay very small objects onto a telescope to be recorded by a high-speed framing camera. To eliminate the laser speckle from a high-power pulsed ruby laser, the laser beam is imaged onto the obscuration of the telescope. The telescope thus collects only the scattered or diffracted light from the small objects. Superior resolution and signal-to-noise ratio are achieved in the recorded image. Because of the high signal-to-noise ratio of the data, full dynamic range of the image system is achieved by applying a log rescaling to the image. Framing cameras are light starved and will not record high-speed images without adequate illumination sources. Because high-power laser sources must be used to illuminate the object for a framing camera, a method to reduce laser speckle noise is required to view very small objects. This dark field illumination technique allows the framing camera to collect diffraction limited images. References 1. D.S. Sorenson et al., "Particle Distribution Measurements Using In-line Fraunhofer Holography," High-speed Photography and Photonics Conference (1 996). 2. D.S. Sorenson et al., "Ejecta Experiments at the Pegasus Pulsed Power Facility," 1 Ith International Pulsed Power Conference, paper P3-5 (1 997).