Lunar Technology Advantages

Similar documents
Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY

COMPUTED TOMOGRAPHY 1

Explain what is meant by a photon and state one of its main properties [2]

Detector technology in simultaneous spectral imaging

PD233: Design of Biomedical Devices and Systems

DXA measurements using a micro computed tomograph system.

LECTURE 1 The Radiographic Image

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

(Refer Slide Time: 00:10)

Maximizing clinical outcomes

Electronic Instrumentation for Radiation Detection Systems

X-rays in medical diagnostics

IBEX MATERIALS DETECTION TECHNOLOGY

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

NM Module Section 2 6 th Edition Christian, Ch. 3

Seminar 8. Radiology S8 1

DALLA LUCE VISIBILE AI RAGGI X: NUOVI RIVELATORI DI IMMAGINI PER RAGGI X A DISCRIMINAZIONE IN ENERGIA ED APPLICAZIONI

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Influence of different iteration levels in fourth generation iterative reconstruction technique on image noise in CT examinations of the neck

TEXTURE ANALYSIS OF X-RAY IMAGES FOR DETECTION OF CHANGES IN BONE MASS AND STRUCTURE

Amorphous Selenium Direct Radiography for Industrial Imaging

CZT Technology: Fundamentals and Applications

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

GE Healthcare. Senographe 2000D Full-field digital mammography system

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Data. microcat +SPECT

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Photomultiplier Tube

SYLLABUS. 1. Identification of Subject:

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Suppression of metal artifacts using image-based monoenergetic DECT imaging

Development of an amplifier module for measuring X-ray spectra using a photomultiplier tube

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

160-slice CT SCANNER / New Standard for the Future

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

CR Basics and FAQ. Overview. Historical Perspective

INTRODUCTION TO FLEXIBLE BRONCHOSCOPY. Fluoroscopy Synopsis HENRI G COLT MD SECOND EDITION THE BRONCHOSCOPY EDUCATION PROJECT SERIES

Multi-Access Biplane Lab

QC Testing for Computed Tomography (CT) Scanner

Beam-Restricting Devices

Radiation Detection Instrumentation

Visibility of Detail

An Activity in Computed Tomography

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

I. Introduction.

Gamma Spectrometer Initial Project Proposal

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

The future of nuclear imaging is clear

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

New spectral benefi ts, proven low dose

CHAPTER 8 GENERIC PERFORMANCE MEASURES

Research Support. Dual-Source CT: What is it and How Do I Test it? Cynthia H. McCollough, Ph.D.

An Activity in Computed Tomography

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Acquisition, Processing and Display

New Detectors for X-Ray Metal Thickness Measuring

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

4. Contrast is the. There must The function of contrast is to:. The types of contrast are.

X-RAYS - NO UNAUTHORISED ENTRY

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

Computerized transverse axial scanning (tomography): Part I. Description of system

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

Introduction of a Single Chip TLD System for Patient Dosimetry

LaBr 3 :Ce, the latest crystal for nuclear medicine

Changing the Shape of Nuclear Medicine

RADspeed Pro. EDGEpackage C501-E041C

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

Maximum Performance, Minimum Space

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography

The importance of radiation quality for optimisation in radiology

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Pinhole collimator design for nuclear survey system

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

X-ray detectors in healthcare and their applications

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

Hardware for High Energy Applications 30 October 2009

Characterization of photon counting CZT detectors for medical x-ray imaging and spectroscopy

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

Tomosynthesis. Energy Subtraction. Long View Imaging

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Wide-Detector CT for TAVR Planning:

Transcription:

Lunar Technology Advantages DXA stands for Dual-Energy X-ray Absorptiometry. It is a measurement method that uses the differences in the absorption of high energy and low energy X-ray photons by different elements in a body to quantify the amount of bone and soft tissue in the body. For example, certain elements in bone minerals (e.g. calcium) will absorb more low-energy X-rays than the elements in soft tissue, enabling a precise and accurate estimate of bone mineral density (BMD). By using relevant algorithms, we can also use the same measured data to determine body composition due to the different density and composition of fat and lean tissue. Based on DXA technology, the Lunar bone densitometry product portfolio (Lunar idxa, Prodigy, and Aria * ) empowers physicians and clinicians to diagnose osteoporosis and fracture risk. ** Lunar idxa and Prodigy may also perform body composition analysis (fat and lean tissue mass). After a DXA scan, the measured values are compared to a reference population at the sole discretion of the physician to achieve desired clinical results. DXA X-ray Beam Generation Methods There are two fundamental approaches to create the X-ray beams needed for a DXA scan: K-edge Filter technique and Energy Switching technique. K-edge Filter Technique Lunar uses a K-edge filter that absorbs the X-rays in the middle energy range, but allows most high energy and low energy X-rays to pass through to the patient (Figure 1). Figure 1: DXA X-ray system using K-edge filter. Filtered Dual Energy X-ray beam Detector Post-patient X-ray beam L H 10 20 30 40 50 60 70 80 90 100 X-ray tube beam Patient Tabletop L 10 20 30 40 50 60 70 80 90 100 H Collimation K-edge Filter L M H Lead barrel 10 20 30 40 50 60 70 80 90 100 Fixed anode X-ray tube (76 kv) gehealthcare.com *Available in select markets ** For full description of intended use, refer to the appropriate product user manual.

The initial beam (red/orange) is created using an ultra-stable X-ray generator with a fixed anode X-ray tube. The K-edge filter creates distinct low energy and high energy portions of the X-ray beam (yellow-green) before transmission through the patient. The patient absorbs more of the low-energy X-rays (yellow) than the high-energy X-rays (green). An energy-sensitive detector absorbs the transmitted X-rays and counts each X-ray photon as either low or high energy as highlighted in Figure 2 Figure 2: Lunar Photon Counting Method. X-rays with various energies are incident on a photon-counting detector. Amplifiers create voltage pulses proportional to X-ray energy and comparators sort them into low and high energy bins. Detector X-ray beam Lunar s photon counting method is a very dose-efficient DXA technique since low and high energy X-rays are simultaneously and individually counted. Furthermore, by blocking X-rays in the middle of the energy range before the patient, the K-edge filter lowers patient dose while improving performance, since it removes X-rays which would not efficiently distinguish between bone and soft tissue. For Prodigy and Aria, the X-ray generator runs at 76 kv and the effective energy of the low- and highenergy portions of the beam are ~35 kev and ~61 kev. Lunar idxa uses a 100 kv generator and K-edge filtering results in ~39 kev and ~71 kev X-ray effective energies. These energies are optimized for bone and tissue separation. Figure 3 shows the difference in attenuation of cortical bone and soft tissue as a function of incident X-ray energy for Prodigy and Aria. The arrows highlight how the bone and soft tissue attenuation differ between low- and high-energy X-rays. Figure 3: Linear attenuation coefficient of cortical bone and soft tissue (left axis) and the Prodigy and Aria X-ray beam intensity (right axis) vs. X-ray energy. Aria & Prodigy K-edge Beam vs. Attenuation 100.0 400000 Bone Attenuation X-ray Energy Soft Tissue Attenuation K-edge filtered beam 350000 300000 Volts Time Energy Low Energy Attenuation (cm -1 ) 10.0 1.0 250000 200000 150000 Number of X-ray photons Time 100000 Comparator Energy: 4 counts Low Energy: 3 counts 0.1 0 10 20 30 40 50 60 70 80 90 100 110 120 50000 Time

Figure 4 is a simplified illustration of how bone mass is calculated. Low and high energy X-rays attenuate differently through a region of tissue containing bone. Attenuation through the material is largely determined by its thickness and density. In regions without bone, the tissue provides a baseline attenuation. Bone mass is calculated by subtracting this baseline from the combined attenuation of tissue and bone. Figure 4: Attenuation differences between low and high energy X-rays through tissue and bone enable bone mineral mass measurements. Bone Absorption Low Energy Absorption Attenuation Low X-ray Detector Technology The detectors in Lunar products perform a crucial task count each individual X-ray photon and classify it as either low-energy or high-energy. Lunar idxa detectors use solid-state crystals (Cadmium Telluride or CdTe) to generate a signal. The X-ray energy is absorbed by the crystal and results in the immediate release of electrons from their atoms (i.e. direct conversion). An applied voltage pushes the electrons out of the crystal, effectively creating a current pulse whose magnitude is proportional to the X-ray energy. Sensitive, low-noise amplifiers boost the signal so that counting electronics can perform the final identification as low or high energy. See Figure 5. Figure 5: Lunar idxa X-ray detector signal generation Tissue Absorption Energy Absorption Attenuation Low V X-ray CdTe i Bone Tissue Energy Energy Switching Technique Another approach for X-ray generation uses an energy-switching X-ray generator to rapidly cycle between low and high voltage. A Lunar competitor uses a generator switching between 100 kv and 140 kv, synchronized to the 50-60 Hz power line frequency. Because the X-ray energy is unstable during data acquisition, it is necessary to correct each pixel measurement using a complex spinning drum composed of air, soft tissue, and bone equivalents. Each pixel needs six sequential measurements (2 energies through 3 chambers) leading to greater dose to the patient. Low Energy Recently Lunar embraced a state-of-the-art technology from the field of Nuclear Medicine known as solid-state photomultipliers * (SSPM) to maintain high performance and provide value. Both Aria and recent Prodigy detectors are now composed of ultra-fast and bright LYSO scintillators (Lutetium-Yttrium Oxyorthosilicate, Lu 2(1-x) Y 2x SiO 5 ) coupled to solid-state photomultipliers. LYSO crystal has the advantages of high light output and density, fast decay time and excellent energy resolution. In comparison, a Lunar competitor uses conventional CT-style Gadox scintillators which are slow, energy-integrating detectors that CT researchers and manufacturers now recognize are intrinsically less dose efficient than photon counting detectors. 1,2 *Also known as silicon photomultiplier (SiPM)

X-rays are absorbed in the scintillator which rapidly and efficiently converts X-ray energy into light (i.e., indirect conversion). Light is channeled to a solid-state photomultiplier which produces a highly amplified signal that is ready for the counting electronics (Figure 6). SSPM s combine the function of the conventional photomultiplier with the compactness, simple operation and low voltage of photodiodes. Figure 7: er Image Resolution of Lunar s Narrow Fan Beam Technology on heavier patients Figure 6: Prodigy10 X-ray detector signal generation Optical photons Incident X-ray SSPM signal Lunar idxa A competitor using larger number of detectors Lumbar Spine Scan, Male Subject Weight: 229 lb/103.9 kg Height: 5.1 ft/ 154.4 cm Bone Mineral Density: 1.28 g/cm 2 LYSO Scintillator Image Quality SSPM Optical glue Image quality and BMD precision fundamentally depend on the number of low- and high-energy X-rays detected per image pixel. An image pixel is the geometric projection of the detector area to the image plane. As may be expected, image quality improves with higher density of image pixels and higher X-ray flux per pixel. The difference in image quality within Lunar s DXA portfolio reflects this. For example, the pixel density of Lunar idxa images is higher than Prodigy images and Lunar idxa s 100 kv source emits more X-rays than Prodigy and Aria s 76 kv source. By balancing smaller image pixels with higher X-ray flux, Lunar idxa maintains good BMD precision (1%) and produces Lunar s highest quality images. It is important to note that increasing the number of detectors does not necessarily improve image quality unless it is accompanied by a higher density of image pixels. * Furthermore, scanning too quickly or with insufficient X-ray source current for a patient s thickness will degrade image quality by starving each image pixel of X-rays. Figure 7 compares a lumbar spine image of a heavy patient (BMI = 46.5) captured from a Lunar idxa scan vs. that captured by our competitor s DXA equipment that uses a higher number of detectors. The sharper image of the Lunar idxa scan is a result of higher X-ray flux per image pixel. Pencil vs. Narrow Fan vs. Wide Fan Beam Technology The earliest DXA scanners used a pencil beam that performed raster scans back-and-forth across the patient. Pencil beams have the advantages of low patient dose and no magnification effects. They perform well and today are a reasonable choice for value product lines or for low-volume customer sites. However, their beam size necessarily requires many sweeps and long scan times. Fan beam systems shorten scan times significantly and two approaches have been commercialized. One of our competitors uses a wide fan beam which makes a single sweep along the patient axis. Whereas, Lunar developed and patented the use of a narrow fan beam technology which combines the best features of pencil beams (no magnification, low dose) with the short scan time of fan beams. Figure 8 shows the three common beam shapes. Figure 8: Pencil, Narrow Fan, and Wide Fan beam scanning techniques Pencil Beam Technique Lunar s Patented Narrow Fan Beam Technique Wide Fan Beam Technique * By analogy, recent improvements in picture quality on smartphones only occurred when the number of pixels increased while the screen size remained the same.

Multi-View Image Reconstruction (MVIR) Technique Lunar s narrow fan beam technique makes multiple transverse sweeps across the site of interest. Sweeps are spaced so that the adjacent fans overlap at the bone above the tabletop, providing multiple views of the bones (Figure 9). Figure 9: Multi-view image reconstruction combines bone images from each sweep to construct images at the correct bone height above the tabletop. The final image has no distortion and accurate distance and areas. Magnification Errors introduced by Single Sweep Wide Fan Beam Techniques The single sweep fan beam technique cannot correctly estimate the object plane (the bone height above the tabletop), resulting in magnification errors that can introduce several problems: 1. Off-center site positioning within the single sweep of a wide fan beam can create geometric distortions. Scoliosis can be severe enough to make centering of the entire spine difficult. To avoid this, the clinician may have to perform scout scans that necessarily imply additional dose. 2. Geometrical measurements of bones (e.g. cortical widths, femoral neck length) may be inaccurate and are necessary for advanced bone strength analyses. 3. Accurate BMC and bone area measurements are important for pediatric patients and total body composition applications 5 and magnification results in height-dependent inaccuracies up to 25%. 6 Lunar s multi-view image reconstruction (MVIR) technique takes advantage of these overlaps, by sliding adjacent sweeps over each other until the bone images in their overlapping regions match. The amount of sliding is related to the bone height above the tabletop by simple geometry. The resulting image is distortion-free in both dimensions. 3,4 This leads to highly accurate BMC, area and distance measurements for every individual patient. Recall that Lunar s intrinsically efficient photon-counting technique means every sweep has low exposure. Thus overlapping sweeps still result in a low overall patient dose and provide all the added benefits of zero magnification and distortion-free images. In contrast, a single wide fan beam imaging may produce magnification errors (figure 10). Figure 10: Narrow fan beam imaging eliminates magnification errors that occur with single sweep wide fan beams. SmartScan SmartScan is an exclusive feature of Lunar DXA bone densitometers which is enabled by transverse scanning with a narrow fan beam (or pencil beam). Bone regions are identified after each transverse sweep and used to estimate where to begin exposing the patient to X-rays on the subsequent sweep. SmartScan simultaneously reduces the scan time and dose to patient. Since SmartScan follows the bone, it can track and capture a scoliotic spine without requiring a scout scan. Wide-angle longitudinal scans cannot target irregular scan sites as efficiently as SmartScan. Figure 11 shows the concept and how it is implemented in a spine scan. Figure 11: SmartScan follows the bone to reduce patient dose and scan time. T12 Wide-Angle Fan Beam vs. Narrow-Angle Fan Beam L2 L1 L3 L4 L5 Mono-dimensional sweep with magnification error & distortion TruView with Multi-View Image Reconstruction for geometry fidelity

Scatter Radiation Scattered radiation can contaminate the measurement of low and high energy X-rays. Scatter occurs when X-rays deflect off material rather than get absorbed. X-rays that scatter lose part of the energy and change direction, somewhat like a billiard ball after a collision. If they scatter into the detector, they will be measured at the wrong energy and will be assumed to have come straight through the patient like the rest of the beam. The inaccurate counting and wrong energy measurements result in BMD inaccuracy. As fan beams get wider they are more prone to scatter contamination, but scatter effects can be minimized by collimating the beam onto a small detector. Since the body is so complex it is very difficult to model and correct for scatter. Systems that use 2-D beams (e.g., cone beams) have scatter radiation contributions that require significant corrections. 7 Table 1 summarizes the relative performance of the three main beam types on important features of DXA scanning. Table 1: Relative intrinsic performance comparison of DXA beam types. Pencil Beam Narrow Fan Wide Fan Scan time Long Short Short Bone height measured No Yes No Magnification effects No No Yes Off-center distortions No No Yes SmartScan Yes Yes No Scattered radiation Lowest Low Conclusion Bone Densitometry products from GE Healthcare (Lunar idxa, Prodigy, Aria) enable a precise and accurate estimate of BMD using highly dose efficient principles. K-edge filtering separates the X-ray beam into low and high-energy portions and reduces unnecessary exposure to the patient. Lunar s solid-state CdTe and LYSO scintillator detectors are highly energy-sensitive, meaning they simultaneously and efficiently count photons and identify them as low- or high-energy. Narrow fan beam techniques and particularly Lunar s multi-view image reconstruction allows accurate, distortion-free images of each patient. MVIR minimizes magnification errors that cause image distortions and BMC inaccuracies which are intrinsic to wide fan beam, single sweep systems. Furthermore, SmartScan uses transverse sweeps of narrow fan beams to reduce patient dose and scan time. SmartScan tracks bone geometries to eliminate errors from off-center positioning and irregular patient physiology. From X-ray beam generation and detection to scanning method and analysis, Lunar bone densitometers enable short scan times and low dose while maintaining excellent clinical performance.

References: 1. McCollough CH, et al, Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT, Radiology, vol. 264, no. 2, pp. 567-580, 2012. 2. Shikhaliev PM, Photon counting spectral CT: improved material decomposition with K-edge-filtered X-rays, Phys Med Biol, vol. 57, no. 6, pp. 1595-1615, 2012. 3. Mazess RB, et al, Axial and Total Body Densitometry Using a Narrow- Angle Fan-Beam, Osteoporos Intl, vol. 11, pp. 158-166, 2000. 4. Boudousq V, et al, Image resolution and magnification using a cone beam densitometer: optimizing data acquisition for hip morphometric analysis, Osteoporos Int, vol. 16, pp. 813-822, 2005. 5. Cole J, et al, Correcting Fan-Beam Magnification in Clinical Densitometry Scans of Growing Subjects, J Clin Densitom, vol. 12, no. 3, p. 322 329, 2009. 6. Center for Information on Technology for Health Care, Clinically Relevant Performance of Two Fan-Beam Densitometers, CITECH, Plymouth Meeting, PA, USA, 2000. 7. Blake GM, et al, Dual X-ray absorptiometry: clinical evaluation of a new cone-beam system., Calcif Tissue Int, vol. 76, no. 2, pp. 113-120, 2005. 2017 General Electric Company All rights reserved. GE Healthcare reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE Healthcare representative for the most current information. GE, the GE Monogram, Prodigy, Aria, SmartScan and Lunar idxa are trademarks of General Electric Company. GE Healthcare, a division of General Electric Company. GE Medical Systems, Inc., doing business as GE Healthcare. January 2017 JB45946XX