PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

Similar documents
PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Basic P-XRD instructions for Operating the Instrument

Using the Open Eularian Cradle (OEC)

General Measurement (BB) Part

Residual Stress Measurement Part

Bruker D8 HRXRD. Collecting Reciprocal Space Maps using the LynxEye Position Sensitive Detector

Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector

Using the R-Axis Spider to run thin films

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016

Precise Theta/2-Theta Measurement (PB/PSA) Part

Radial Polarization Converter With LC Driver USER MANUAL

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Standard Operating Procedure for STOE STADI MP (IMSERC)

General Measurement (CALSA) Part

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection)

Lesson 2 Diffractometers

Physics 476LW. Advanced Physics Laboratory - Microwave Optics

ADVANCED OPTICS LAB -ECEN 5606

J. La Favre Fusion 360 Lesson 5 April 24, 2017

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

Atomic and nuclear physics

Advance Steel. Tutorial

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

Part 1: Standing Waves - Measuring Wavelengths

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P

Kit for building your own THz Time-Domain Spectrometer

Experiment #12 X-Ray Diffraction Laboratory

Figure 1 The Raith 150 TWO

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide

Module 2: Radial-Line Sheet-Metal 3D Modeling and 2D Pattern Development: Right Cone (Regular, Frustum, and Truncated)

The operation manual of spotlight 300 IR microscope

1 Diffraction of Microwaves

Experiment 19. Microwave Optics 1

Instruction Manual for HyperScan Spectrometer

UV-Vis-NIR Spectrophotometer Quick Start Guide

Alignment of the camera

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

Microwave Optics. Department of Physics & Astronomy Texas Christian University, Fort Worth, TX. January 16, 2014

Eric B. Burgh University of Wisconsin. 1. Scope

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics

AgilEye Manual Version 2.0 February 28, 2007

PAD Correlator Computer

Operating Procedures for MICROCT1 Nikon XTH 225 ST

Standard Operating Procedure

Renishaw InVia Raman microscope

NCSS Statistical Software

Software Manual for the Economy LBIC Demo

The 34th International Physics Olympiad

Modeling Basic Mechanical Components #1 Tie-Wrap Clip

PHYS2090 OPTICAL PHYSICS Laboratory Microwaves

ADC COMPACT FULL-LEG/FULL-SPINE APPLICATION SOFTWARE USER MANUAL

Polarization Experiments Using Jones Calculus

Bruker D8 Discover with GADDS

DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT

Excel Lab 2: Plots of Data Sets

X-ray investigation of crystal structures / Laue method with digital X-ray detector (XRIS) (Item No.: P )

TOWARDS FAST RECIPROCAL SPACE MAPPING

WITec Alpha 300R Quick Operation Summary October 2018

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Automated Double Aperture Accessory

RENISHAW INVIA RAMAN SPECTROMETER

Learning Guide. ASR Automated Systems Research Inc. # Douglas Crescent, Langley, BC. V3A 4B6. Fax:

Lab 12 Microwave Optics.

DPM Kit DK-1. Using the DPM Kit

(Oct revision) Physics 307 Laboratory Experiment #4 The Photoelectric Eect

Slicing Off-Axis Si, SiGe, and Ge Wafers

Excel Tool: Plots of Data Sets

Step 1: Set up the variables AB Design. Use the top cells to label the variables that will be displayed on the X and Y axes of the graph

RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE

Class #9: Experiment Diodes Part II: LEDs

Bruker D8 Discover with GADDS

Creo Revolve Tutorial

Devices & Services Company

CHAPTER 15. Cross Section Sheets. None, except batch processing of an input file.

Coherent Laser Measurement and Control Beam Diagnostics

ScanArray Overview. Principle of Operation. Instrument Components

WALLY ROTARY ENCODER. USER MANUAL v. 1.0

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT

Single-Slit Diffraction. = m, (Eq. 1)

Part 8: The Front Cover

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Experiment P10: Acceleration of a Dynamics Cart II (Motion Sensor)

Create A Mug. Skills Learned. Settings Sketching 3-D Features. Revolve Offset Plane Sweep Fillet Decal* Offset Arc

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

EE 210 Lab Exercise #3 Introduction to PSPICE

The designs for a high resolution Czerny-Turner spectrometer are presented. The results of optical

Conversational CAM Manual

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

You will need the following pieces of equipment to complete this experiment: Wilkinson power divider (3-port board with oval-shaped trace on it)

Single Slit Diffraction

SolidWorks Design & Technology

Chapter 6 Title Blocks

Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA)

User s Guide Modulator Alignment Procedure

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

Part 2: Earpiece. Insert Protrusion (Internal Sketch) Hole Patterns Getting Started with Pro/ENGINEER Wildfire. Round extrusion.

DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

Rigaku Cr-Source RU300 Rotating Anode X-Ray Generator 185mm Radius Diffractometer

Transcription:

University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: 2012.10.17) The following instructions are meant to be a guide, but many of the scan parameters may change based on your samples and experience. Please note that the optics are delicate; do not bump or drop the optic housing units. If the x-rays are off, NEVER attempt to turn them back on unless specifically instructed by an x-ray scattering lab staff member. Hardware setup 1. The system must be setup with the x-ray tube using the line source. The hybrid monochromator must be mounted on the incident beam side. Make sure the beam attenuator cable is plugged into the hybrid. Install the ½ divergence slit into the hybrid module, and if the sample is less than 25 mm an appropriate beam mask should be inserted. 1

2. The rocking curve (RC) + triple axis mount must be attached on the diffracted beam side with Detector 1 attached to the triple axis position (if you are going to use triple axis mode) and Detector 2 attached to the rocking curve position (if you are going to use rocking curve mode). While a variety of diffracted beam slits can be installed to improve resolution, a ½ slit should be installed for general purpose scanning. Note: The following are the definitions of the angles in the software: ω angle between incident x-rays and sample surface 2θ angle between incident x-rays and detector ψ azimuthal sample tilt φ in-plane sample rotation x,y horizontal and vertical position of sample, respectively z sample height φ 2θ ω ψ 2

User setup 3. Log onto the computer: User: Charfac code # (for example 2310); Password; Domain: CharFac. 4. Open the Data Collector program. 5. Enter your user name (created during training) and password. 6. Select Instrument/Connect in the Data Collector. The Go On Line box will appear. 7. Select High Resolution as the Configuration and RC as the Beam Path. Then press the OK button. 8. A message dialog box will appear. Any line with a yellow triangle tells what the software is assuming. Press the OK button. If a red stop sign appears, you cannot continue, please find an x-ray staff member for assistance. 9. If you previously had set sample offsets, a dialog may appear asking if you want to apply these offsets. Yes keeps the sample offsets, No clears them. Unless you were the last person to use the machine, it is a very good idea to clear the offsets. Optics setup 10. Select the Incident Beam Optics tab and double click on one of the item lines: a. PreFIX Module: Ge 4-bounce hybrid. b. Divergence Slit: 1/2 o divergence slit c. Beam Attenuator: Ni 0.125 mm automatic, Usage should be Do Not Switch and the Activated box should be checked. It is highly recommended to cycle from Activated Deactivated Activated to check if the attenuator is working properly. d. Mask: Select appropriate size Inc. Mask Fixed 5,10,15,20 mm (MPD/MRD). 11. Select the Diffracted Beam Optics tab and double click on one of the item lines: a. PreFix Module: Triple Axis (Rocking Curve Optics). b. Receiving Slit: Parallel Plate Collimator Slit. c. Detector: Mini prop large window 2 and the Wavelength is K alpha 1. 12. Optional: If you will be using the triple axis detector, right mouse click on Triple Axis in the Diffracted Beam Optics window tab and select Activate. The PreFix Module should be selected to be the Triple Axis (Monochromator 3 Bounce). Make sure the Detector is mini prop large window 1 and the Wavelength is K alpha 1. 13. Select the Instrument Settings tab, double click an item, select the X-ray tab, and set the Generator to 45 kv and 40 ma. 3

Sample mounting 14. Select the Instrument Settings tab, double click an item, select the Position tab, set all positions to either 0 o or 0 mm. Press the Apply button to move the stage. 15. Remove the sample holder by rotating until it releases. 16. Mount the sample as flat as possible on the stage with double sided tape or spring clips for large wafer samples. If the sample is larger than 5 mm, mount the long axis of the sample along the beam direction (i.e. horizontal, x-direction). If the sample is less than 5 mm, mount the long axis azimuthally to the beam direction (i.e. vertical, y-direction). These alignments will assist in providing the lowest background noise and maximizing signal strength. 17. Load the sample holder into the system. Checking the zero position and direct beam intensity 18. Go to the Measure menu and select Manual Scan. 19. The Manual Scan window will appear. Enter into the following fields: Scan Axis: 2theta, Scan Mode: Continuous, Range: 2.0 o, Step Size: 0.005, and Time per Step: 0.1 s. Press the Start button to begin the scan. 20. After the scan is finished, right mouse click on the graph and select Peak Mode. 21. To accept the location of the peak, press the Move To button and then select OK. To select a different position of the peak, press Cancel, right mouse click on the graph, and select Move Mode. This will move the goniometer to the user defined position. 22. Once the correct position of the detector is found, click on the Tools menu and select Sample Offsets. Set 2theta = 0.0 o and select OK button. This will correct for the zero position and make the current 2θ value 0.0 o. 4

Setting the correct sample height and horizontal tilt 23. The correct sample height has been aligned when the sample bisects the direct incident beam it reduces the direct beam intensity to ½ the original value. 24. Select the Instrument Settings tab, double click an item, select the Position tab, set Z to 7.0 mm. Press the OK button to move the stage 25. Go to the Measure menu and select Manual Scan. 26. The Manual Scan window will appear. Enter into the following fields: Scan Axis: Z, Scan Mode: Continuous, Range: 4.0 mm, Step Size: 0.01 mm, and Time per Step: 0.1 s. Press the Start button to begin the scan. 27. The graph should look like a Heaviside step function with high intensity at low Z values and zero intensity at high Z values. Using Move Mode, move the green cursor until the intensity is ½ of the maximum intensity in the low Z range. a. If the Heaviside step has an intermediate step in it, move the green cursor to the Z value that halves the intensity between the maximum intensity in the low Z range and the intermediate step. This intermediate step usually occurs when the sample s vertical width (y-direction) is smaller than the beam mask. 28. Return to the Manual Scan window. Enter into the following fields: Scan Axis: Omega, Scan Mode: Continuous, Range: 4.0 o, Step Size: 0.01, and Time per Step: 0.1 s. Press the Start button to begin the scan. 29. Use either Move Mode or Peak Mode (preferred) to center to the observed peak. 30. Repeat steps 26 27 until both Z and omega positions do not change significantly. A good simple guide is that Z should not shift more than 0.01 mm in subsequent iterations 31. Once the optimum values have been found, click on the Tools menu and select Sample Offsets. Set the Omega value to 0.0 o. This will make the current ω value read as 0.0 o Peak Optimization 32. It is highly recommended to align the sample in subsequent steps with respect to a known crystallographic plane. The best choice for this is to use a known substrate peak. The Collector software has a large database of common substrates pre-loaded, but it is also possible to load new substrates into the database. a. Select Customize/Unit cells and then press the insert button. b. Enter all the requested information for the unit cell. The primary and secondary hkl are the growth vector and a wafer flat vector respectively. (If no wafer flat is present any vector perpendicular to the growth vector is sufficient.) The hkl values must be entered as integers with spaces between them. 5

c. After entering the all the information, press the OK button and notice the new cell added to the list. Then press the OK button. 33. Select Customize/Options and make sure the radio button in front of Single Crystal mode is checked. Close this window. 34. If the scan will be performed in Triple Axis mode, it is still much easier to initially find the peak in rocking curve mode and then switch to triple axis for the final alignment. To switch between the modes, right mouse click on Triple Axis or Rocking Curve in the Diffracted Beam Optics window tab and select Activate. 35. Before a scan is collected for an extended measuring time, preliminary scans are usually done to optimize the peak(s) of interest. This is done using manual alignment measurements of ω and ψ. 36. In Instrument Settings tab, double click on an item, select the Position tab, and select the substrate material in the unit cell field. a. If unit cell information was not entered, enter the 2θ value for the peak of interest in the 2theta field and 0 in the Offset field and press the OK button. Continue to Step 40. 37. Enter the plane of interest in the HKL field. This will set all the angles to the theoretical values for this crystallographic plane. Then press the OK button. 38. Select Measure/Manual Scan from the main menu. 39. Return to the Manual Scan window. Enter into the following fields: Scan Axis: 2theta/Omega, Scan Mode: Continuous, Range: 2.0 o, Step Size: 0.01, and Time per Step: 0.2 s. Press the Start button to begin the scan. 40. After the scan is finished, use Move Mode or Peak Mode (preferred) to center onto the most intense peak. a. Ideally if the initial zero alignments were done correctly, the center of the peak should line up with the theoretical value of the (hkl) plane that was aligned. In reality this is can be difficult due to not aligning the z-axis perfectly, causing a sample displacement error in peak positions. This shift is often very minor, and can be corrected using numerous models. The JADE software has an excellent displacement error correction routine and is highly recommended. 41. Return to the Manual Scan window. Enter into the following fields: Scan Axis: Omega, Scan Mode: Continuous, Range: 1.0 o, Step Size: 0.005, and Time per Step: 0.3 s. Press the Start button to begin the scan. 42. After the scan is finished, right mouse click on the graph, select Axes, and choose linear for the Type of scale for the graph. Using Move Mode or Peak Mode (preferred), center onto the most intense peak. 6

43. Return to the Manual Scan window. Enter into the following fields: Scan Axis: Psi, Scan Mode: Continuous, Range: 6.0 o, Step Size: 0.01, and Time per Step: 0.3 s. Press the Start button to begin the scan. 44. After the scan is complete, select either Move Mode or Peak Mode (preferred) to center onto the measured peak. 45. Optional: If the sample is smaller than 5 mm in the vertical direction (y-direction), a y- direction scan might be needed to make sure that the sample is aligned vertically. a. To do this return to the Manual Scan window. Enter into the following fields: Scan Axis: y, Scan Mode: Continuous, Range: 10.0 mm, Step Size: 0.1 mm, and Time per Step: 0.5 s. Press the Start button b. After the scan is complete, select either Move Mode or Peak Mode (preferred) to center onto the measured peak. c. Repeat Steps 41-42. 46. Return to the Manual Scan window. Enter into the following fields: Scan Axis: Omega, Scan Mode: Continuous, Range: 0.5 o, Step Size: 0.005, and Time per Step: 0.5 s. Press the Start button to begin the scan 47. After the scan is complete, select either Move Mode or Peak Mode (preferred) center onto the measured peak. 48. Repeat Steps 39 45 until the positions of ω, ψ, and y (optional) do not move significantly. Usually one or two iterations are needed. 49. Once the optimum values have been found, click on the Tools menu and select Sample Offsets. Set the Omega value to exactly ½ of the current 2theta value. 50. Back in the control window select the Incident Beam Optics tab. Double click on an item related to the beam attenuator. Change the Usage field to Switch at preset intensity, set the Activate Level to 500,000, and the Deactivate Level to 400,000. 7

Measurement Program 51. Select File/New Program/Relative scan for a rocking curve and Relative scan or Absolute Scan for a coupled scan. A relative scan is centered on the current position of the goniometer. An absolute scan scans a specific range of angles and is often used for coupled scans. 52. Make sure that the desired Rocking Curve or Triple Axis setting is selected as the Secondary Beam Path. The Scan Axis should be omega for a rocking curve and 2theta-omega for a coupled scan (omega-2theta is also a coupled scan but the reference angle is ω instead of 2θ). The Scan Mode is typically set to continuous and the Time Per Step should be in the range of 0.5 5.0 s. It is important to remember that these are suggested values and the actual parameters needed for each measurement will vary upon the sample. 53. Select File/Save as and enter a name for the program and then press the OK button. Close this window. 54. Select Measure/Program/Relative scan or Absolute Scan depending on which type of program was created above. When Done 55. Make sure the attenuator is set to Switch at Preset Intensity or Do Not Switch Activated. 56. Power the x-rays down to 40 kv and 10 ma. 57. Close the program, transfer your data (files are not backed up), and log off the computer. Files can be viewed with the Data Viewer program and converted to ascii text files if desired. Please leave the work area clean. Remember CharFac is a user facility, and we all need to do our part to keep the work area clean! 8