HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

Similar documents
METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

900 SERIES WALL PANELS

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

DW VERTICAL INSTALLATION

400 SERIES VERTICAL INSTALLATION

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

ARCHITECTURAL STICK SYSTEMS

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

KS42 MF SERIES - HORIZONTAL INSTALLATION

Dear Contractor, I am glad that you are interested in our window rebate program.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

4500 Series. Fabrication and Installation Instructions

Site Preparation Information for:

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

14000 Series. Fabrication and Installation Instructions

SECTION HOLLOW METAL DOORS AND FRAMES

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Installation Recommendations for Finless Frame Doors

14000 Series. Fabrication and Installation Instructions

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

YES 600 Thermal Clip Storefront System Installation Manual

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

ENTRY DOOR TEST REPORT. Rendered to: The Vistawall Group

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY. PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom

DW HORIZONTAL INSTALLATION

CERTIFICATE OF APPROVAL No CF 581 CGI INTERNATIONAL LIMITED

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

KS SERIES - VERTICAL INSTALLATION

SECTION BULLET- RESISTANT DOORS

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Thermally Broken Framing and Door Installation

INSTALLATION INSTRUCTIONS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Series 9000 Vinyl Fixed Window

YES 40 FS/FI Storefront System Installation Manual

Series 6000 Vinyl Single Hung

Through and through, our metal frames stand strong.

series 9500 top load bi4fold installation instructions

Installation Instructions

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

CERTIFICATE OF APPROVAL No CF 718 PILKINGTON GROUP LIMITED

Integrity Polygon and Round Top Installation and Finishing Instructions

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan

Series 9000 Vinyl Single Hung

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

YES 45 TU Thermal Storefront System Installation Manual

Heavy Wall Applied Stop Tube Frame and Door Installation

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Installation Guide for Andersen 200 Series Tilt-Wash Picture, Transom and Circle Top Windows

Subject: Specification Compliance

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

SECTION HOLLOW METAL DOORS AND FRAMES

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

YES 45 FS/FI Storefront System Installation Manual

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

Series 6000 Vinyl Horizontal Slider

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly

Series 9000 Vinyl Fixed Window

Seamed Edge Doors 1000 Series

Series Sloped glazed Curtain wall. Installation Instructions

TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT. Rendered to: DIAMOND DOOR PRODUCTS

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

26- H i n g e d P a t i o D o o r s - I n s w i n g

Side Light Frame Pack Assembly Instructions

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

~ ~ -

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

INTERIOR ALUMINUM DOORS AND FRAMES

INSTALLATION INSTRUCTION SINGLE PANEL, SINGLE PANEL WITH SIDELIGHT COMBINATION AND 20 MINUTE FIRE RATED WOOD FRAME ENTRY DOOR

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

COMPOSITE SIDING INSTALLATION GUIDE

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

Side Light Frame Pack Assembly Instructions

YWE 40 T Window Wall System Installation Manual

CROSSBAR RAFTER ISOMETRIC

BXUV.V470. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

ELEPHANT DOOR SYSTEMS SERIES E1200

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

Curtain Wall Installation Guide

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual

Transcription:

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

PIONEERING INSULATED METAL PANEL TECHNOLOGY

TABLE OF CONTENTS DETAIL TITLE PAGE NO. Introduction...2 System Description....3-5 Door & Window Frame Variations...6 General Door Sections...7 General Window Sections...8 Fire Rated Door & Window Frame Sections (with support angles)...9 Fire Rated Door & Window Frame Sections (with support channels)...10 Non-Fire Rated Door & Window Frame Sections (with support angles)..11 Non-Fire Rated Door & Window Frame Sections (with support channels)..12 Requirements for Framing Parts...13 Door & Window Framing Assemblies.....14 Wall Panel Cutouts...15 Door & Window Frame Preparation......16 Installing Window Frame........17 Installing Door Frame....18 Alignment of Door & Window Frame...19 Door - Interior Seal & Support Framing...20 Window - Interior Seal and Support Framing...21 Door & Window Drip Gutter Installation...22 Door & Window Head Flashing Installation...23 1

INTRODUCTION Metl-Span has developed a hollow metal door and window system to further complement the exceptional function and performance of the ThermalSafe and CF wall panels. When used in a ThermalSafe wall, the doors and windows may be fire resistance rated. This is the first and only UL rated system of fire rated doors and windows for walls constructed of mineral fiber insulated panels. Just another example of Metl-Span s pioneering role in composite panel technology. The door/window framing system allows standard door and window units (provided by the contractor) to be integrated within ThermalSafe and CF walls, with minimum intrusion into the interior space, and do so with great flexibility of door and window types, configurations, size and options. The system even allows doors and windows to be combined to provide for transoms and sidelights etc. Included within this bulletin are the system s description, architectural details and installation details. This information is intended to be used by the building designer, specifier and the installer for their understanding of the system and its application. The technical bulletin is to be used in conjunction with the project s installation drawings or specifications. In case of conflict between the information in this bulletin and installation drawings or specifications, the drawings or specifications will govern. The customer is responsible for selecting competent building designers, door/window manufacturers and installers, and must ensure that the applications of the door /window system are suitable for the specific building conditions and are in accordance with good engineering and construction practices and all applicable building codes and regulations. Metl-Span does not guarantee and is not liable for the quality of the door /window design, fabrication and installation, and is not responsible for defects that are attributable to improper design, fabrication, installation or negligence by other parties. Clarifications concerning the door/window system should be directed to: Metl-Span Technical Services Department 1497 N. Kealy, Lewisville, TX 75057 Tel: (877) 585-9969 Fax: (972) 436-7028 E-Mail: panel@metlspan.com WEB: METLSPAN.COM 2

DOOR/WINDOW SYSTEM DESCRIPTION General: the door/window system provides for the integration of hollow metal framed door and window assemblies into walls constructed of Metl-Span s ThermalSafe and CF insulated panels. The door and window assemblies and installation materials are to be provided by the contractor in accordance with the specifications in this technical bulletin. Fire Resistance Rated: when used in ThermalSafe walls, the door and window assemblies may be fire resistance rated by UL (Underwriters Laboratory, Inc.). When used in CF walls, door and window assemblies are not fire resistance rated. Door assemblies constructed in accordance with UL Assembly No. SP-2-001, and the requirements specified in this technical bulletin, will meet the criteria of UL 10B, UL10C, CAN4-S104 and UBC Standard 7-2 (1997) for a 1 1 /2 hr. (maximum) fire resistance rating. Window assemblies constructed in accordance with UL Assembly No. WA-2-001, and the requirements specified in this technical bulletin, will meet the criteria of UL 9, CAN4-S106 and UBC 7-4 (1997), tested under positive pressure for a 1 1 /2 hr. (maximum) fire resistance rating. UL Assemblies No. SP-2-001 and WA-2-001 provide for a broad range of door and window options. Refer to these assemblies in the UL online certifications directory for specific description of the options. Wall Requirements: the door/window system may be used in walls consisting of Metl-Span s ThermalSafe or CF wall panels. Doors and windows assemblies may be fire resistance rated only when used in ThermalSafe walls which are constructed in accordance with UL Design No. U050. The door/window system may be used in exterior walls and interior walls (partitions), and the wall panels (including fire rated walls) may be vertically or horizontally oriented. The allowable wall panel thickness is dependent upon the door/window frame depth and fire resistance rating (when applicable). Reference the Frame Schedule on the following pages of this bulletin. Frame Construction: the door and window frames are to be of standard hollow metal (drywall) design, consisting of jamb and head members for doors, and jamb, head and sill members for windows. The standard frame depth is either 5 3 /4 or 8 3 /4, depending upon the wall panel thickness. 3

DOOR/WINDOW SYSTEM DESCRIPTION (cont.) The maximum allowable frame size for doors, windows or door/window combinations is 8 wide x 8 high (inside opening). The frame members are to be made of 16 gauge (min.) steel, with 2 wide faces and 1 /2 deep returns with 3 /8 (min.) wide back bend. Door frame corner connections may be welded or knock down (KD) for field assembly. Window frame corner connections are to be welded. The frames may include horizontal or vertical mullions, as required for division of glazing or separation of doors and windows areas within the same frame. Self-Flashing Design: the edges of the wall panels are enclosed within the frame members, and the exterior face of the frame is set flush against the wall surface. In this manner, the door and window frames are self-flashing on the exterior, and there is minimum intrusion of the frames into the building s interior space. Head Options: optional surface mounted drip gutters or thru-the-panel head flashing may be used above the door/window assembly. The optional drip gutter is recommended for exterior doors and windows when the wall panel joints have the weather/vapor seal at the exterior side. The optional head flashing is recommended for exterior doors and windows when the walls have self-draining joints with the weather/vapor seal at the interior side of the wall. Door Frame Base Clips: each door frame jamb is to be provided with a base clip. The floor mounting flange of the base clip is to project into the door opening for installation access of the masonry fasteners. The heads of the masonry fasteners are then covered by the threshold. Support Framing System: support members (angles or channels) are to be provided to serve the multiple functions of connecting the door/window frame to the wall panels, providing structural support to the door/window assembly, and function as flashing which covers the gap between the interior perimeter of the frame and the interior wall surface. The vertical jamb support members span between the wall s base framing member and the horizontal wall framing member above the door/window assembly, and are connected to these members. 4

DOOR/WINDOW SYSTEM DESCRIPTION (cont.) The horizontal head and sill support members span between the jamb support members. The support members are attached to the door/window frame and interior wall panel surface with #12 self-drilling screws. Support Framing Design: the support members are to be designed as angle or channel sections with sufficient material thickness and web depth to provide the required structural support in accordance with project s design loads. When allowed by the load/span requirements, the web depth of the support angles may be limited so it does not project beyond the interior face of the door/window frame. Seals (fire rated doors and windows only): the cavity between the inside of the frame members and the cut edge of the wall panels is to be continuously filled with 1 thick, 4 pcf (min.) density mineral fiber batt insulation. On the exterior side of the wall, the perimeter of the frame is continuously sealed to the wall surface with a 1 /16 thick x 1 /2 wide intumescent weatherstrip tape*. On the interior side of the wall, the support framing members are continuously sealed to the wall surface with a 1 /16 thick x 1 wide intumescent tape*, and the support framing members are continuously sealed to the interior perimeter of the door/window frame with a 1 /16 thick x 1 /2 wide intumescent tape*. * The intumescent tapes are to be Blaze Seal brand manufactured by Rectorseal Corp., Phone: 1-800-231-3345 Seals (non-fire rated doors and windows): on non-fire rated door and window assemblies, the cavity between the inside of the frame members and the cut edge of the wall panels is to be continuously filled with fiberglass batt insulation. The door/window frame may be sealed to the wall surfaces with butyl tape or urethane sealant as determined by the weather and vapor seal requirements. 5

DOOR & WINDOW FRAME VARIATIONS MSS110.001 6

GENERAL DOOR SECTIONS MSS110.002 7

GENERAL WINDOW SECTIONS MSS110.003 8

FIRE RATED DOOR & WINDOW FRAME SECTIONS (with support angles) MSS110.004 9

FIRE RATED DOOR & WINDOW FRAME SECTIONS (with support channels) MSS110.005 10

NON-FIRE RATED DOOR & WINDOW FRAME SECTIONS (with support angles) MSS110.006 11

NON-FIRE RATED DOOR & WINDOW FRAME SECTIONS (with support channels) MSS110.007 12

REQUIREMENTS FOR FRAMING PARTS MSS110.008 13

DOOR & WINDOW FRAMING ASSEMBLIES MSS110.009 14

WALL PANEL CUTOUTS MSS110.010 15

DOOR & WINDOW FRAME PREPARATION MSS110.011 16

INSTALLING WINDOW FRAME MSS110.012 17

INSTALLING DOOR FRAME MSS110.013 18

ALIGNMENT OF DOOR & WINDOW FRAME MSS110.014 19

DOOR INTERIOR SEAL & SUPPORT FRAMING MSS110.016 20

WINDOW INTERIOR SEAL & SUPPORT FRAMING MSS110.017 21

DOOR & WINDOW DRIP GUTTER INSTALLATION MSS110.018 22

DOOR & WINDOW HEAD FLASHING INSTALLATION MSS110.019 23

Notes: This Installation Guide is and remains the property of Metl-Span LLC - may not be reproduced or published without the written permission of Metl-Span. All products and data described herein are subject to change without notice. Contact Metl-Span for the current information. 2012 Metl-Span LLC - All rights reserved. 24

PIONEERING INSULATED METAL PANEL TECHNOLOGY