Q.raxx A slimline RS / EC

Similar documents
Q.raxx A101-8 slimline RS / EC

Q.raxx A slimline RS / EC Universal Measurement System

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

B850 Boiler House Energy Monitor

USB-2404-UI Specifications

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

NEW! AOIP FD5 Advanced Digital Data Logger

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Side view View from below Rear view

UMG 509-PRO. Multifunction power analyser with RCM

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

B850 Boiler House Energy Monitor

imc C-SERIES: CS-5008-FD

Process displays For standard signals, temperature, resistance measurement

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

FRONTDAQ 20. High speed acquisition module with universal synchronized inputs and embedded webserver software

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

2A (recommended) Power loss

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

LAUREL ELECTRONICS, INC.

Data sheet CPU 314ST/DPM (314-6CF02)

High Performance Process & Temperature Controllers

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

MX1615. Data sheet. Bridge/strain gauge amplifier

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

Transienten. Datenspeicher

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

MULTIFUNCTION GRAPHICAL UNIT MGU 800

imc C-SERIES: CS-1016-N, CL-1032-N

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

Product type designation. General information. Supply voltage

Excellent low-cost Process & Temperature Controllers

Kistler LabAmp for DynoWare

Industrial Modbus I/O Modules

Trendmaster * Dynamic Scanning Module

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DRG-SC Series Signal Conditioners

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

NEW! Transient Data Acquisition. Stand alone. Compact. Powerful.

S200 I/O System Units

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

90 Day TCAL ±5 C. = channel 2 reading channel 2 accuracy channel 2 reading

CONTA-ELECTRONICS. Converter Units

Data sheet CPU 313SC (313-5BF13)

V or 64-channel Scanning ADC. APPLICATIONS. The V213 is a single-width, C-size, register-based, VXIbus

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

8558A 8 1/2 Digit Multimeter

22 kw 4Q POWER AMPLIFIER RS232

Portable Multi-Channel Recorder Model DAS240-BAT

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

CAN-IO Custom IO remote module

SHIMADEN DIGITAL INDICATORS

DIGITAL PANEL INSTRUMENTS

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

General information. Supply voltage

CompactLogix 5370 L3 Control System

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

PFXLM4B01 D * * (1) (2) (3) (4)

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

ADAM 4000/4100 Series

imc C-SERIES: CS-3008-N, CL-3016-N

SDM3045X Digital Multimeter. DataSheet

WIRELESS MODBUS GATEWAY WGW410

MX1615B. Data sheet. Bridge/strain gauge amplifier

Improve asset protection and utilization

Main Features. Highlights

Temperature Measurement

Model Channels Input type Sample rate Resolution

CPU 314C-2 PTP. Function

Data sheet CPU 013C (013-CCF0R00)

Modular Smart Interfaces

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

ND40 - POWER NETWORK ANALYZER /RECORDER

Transcription:

The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary testing and assembly. The EC version includes a Test Controller that offers the user a powerful solution with PAC functionality, synchronized data acquisition, sequencing, mathematics, combinations a Ethernet TCP/IP interface as well as a EtherCAT fieldbus. It is possible to connect three slimline basic units to the Test Controller of a slimline EC unit. Beside the pre-defined standard versions customized systems regarding numbers of channels, kind of measurement inputs/connectable sensors as well as the required connectors are configurable. This modularity permits to design an optimized individual solution for any application. Further it is possible to mix different product lines like Q.raxx, Q.bloxx within Q.series. Most important features: 16 universal analog input channels voltage, current, resistance, potentiometer, Pt100, Pt1000, thermocouple, measuring bridge Fast high accuracy digitalization 24 bit ADC, 10 khz sample rate per channel Signal conditioning Linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm Galvanic isolation Kanal II Kanal II Versorgung II Schnittstelle, V iso 500 VDC Galvanic isolation of analog in/out, power supply and interface, V iso 500 VDC Power supply 10 30 VDC With embedded Test Controller (version EC): Optional fieldbus interface EtherCAT EtherCAT according specification ETG, 254 read and 254 write variable with 10 khz Ethernet interface for configuration and data output FTP, TCP/IP, UDP FTP Server and FTP Client functionality configurable function High data rate over Ethernet 16 real variables with 10 khz (block transfer) 64 real variables with 300 Hz (online Data buffer memory dyn. 16 MByte (RAM), stat. 128 MByte (flash) data buffer at block transfer of measurements Connection of additional racks to the Test Controller up to 3 slimline racks without Test Controller can be connected to a slimline EC system with embedded controller

Connection Diagram Q.raxx slimline EC Analog Inputs Number 16 Accuracy 0.01 % typical 0.02 % in controlled environment¹ 0.05 % in industrial area² Linearity error 0.01 % of the final value typical Repeatability 0.003 % typical (within 24 h) Isolation voltage 500 VDC channel to channel to power supply to interface 3 Measurement Voltage Range max. Deviation Resolution ±10 V ±2 mv 1.2 µv ±1 V ±0.2 mv 120 nv ±100 mv ±20 µv 12 nv Input resistance >100 MΩ Temperature influence Range on zero on sensitivity ±10 V <500 µv / 10K <0,01 % / 10 K ±1 V <50 µv / 10K <0,01 % / 10 K ±100 mv <5 µv / 10K <0,01 % / 10 K Long term drift Range 24 h 8000 h ±10 V <200 µv >2 mv ±1 V <20 µv >200 µv ±100 mv <2 µv >20 µv Signal-noise-ratio >90 db at 1 khz >120 db at 1 Hz

Measurement Current Range max. Deviation Resolution (internal shunt 50 Ω) ±25 ma ±5 µa 3.0 na Temperature influence on zero on sensitivity <1 µa / 10 K <0.03 % / 10 K Long term drift <0.5 µa/24 h; <5 µa/8000 h Measurement Resistance / RTD Range max. Deviation Resolution Resistance, 2-wire 100 kω ±100 Ω 12 mω Resistance, 2- and 4-wire 4 kω ±1 Ω 0.5 mω Resistance, 2- and 4-wire 400 Ω ±0.1 Ω 48 µω Pt100, 2- and 4-wire -200 up to +850 C ±0.25 C 0.2 m C Pt1000, 2- and 4-wire -200 up to +850 C ±1 C 0.2 m C Temperature influence on zero (range 400 Ω) on sensitivity <10 mω / 10 K 0.05 C / 10 K <0.03 % / 10 K Long term drift <10 mω / 24 h; <100 mω / 8000h (range 400 Ω) Measurement Potentiometer Permitted potentiometer resistance Relative measurement 1 kω to 10 kω Temperature influence on zero (range 1) on sensitivity <0.0001 /10 K <0.03 % / 10 K Long term drift <0.02 % / 24 h, <0.05 % / 8000 h Measurement Bridge Accuracy class 0.05 Bridge Type full bridge, 4-wire connection Sensor resistance >100 Ω Supply 2.5 V nominal Measurement range ±2.5 mv/v ±50 mv/v ±500 mv/v Temperature influence on zero (range 2.5 mv/v) on sensitivity <0.2 µv/v / 10 K <0.05 % / 10 K Long term drift <0.12 µv/v / 24h; <1.25 µv/v / 8000 h (range 2.5 mv/v) Measurement Thermocouple Whole range -100 C...upper limit Type B better than ±5 C better than ±2.5 C Type E, J, K, L, T, U better than ±1 C better than ±0.5 C Type N better than ±2 C better than ±1 C Type R, S better than ±3 C better than ±1.5 C Input resistance >100 MΩ Temperature influence on zero on sensitivity Long term drift Uncertainty cold junction compens. <0.2 C / 10 K <0.02 C/24 h; 0.2 C/8000 h <0.3 C <0.025% / 10 K 1 according EN 61326: 1997, appendix B 2 according EN 61326: 1997, appendix A 3 noise pulses up to 1000 VDC, permanent up to 250 VDC

Analog/Digital-Conversion Resolution 24 bit Sample rate 10 khz, (measurement thermocouple 10 Hz) Conversion method Sigma-Delta (group delay time 3.8 ms) Anti-aliasing filter 2 khz, 5 th order Digital filter IIR, low pass, high pass, band pass, 4 th order, 1 Hz up to 1 khz in steps 1, 2, 5 Averaging configurable or automated according the selected data rate Digital Inputs (slimline EC only) Function Input voltage Input current Upper switching threshold Lower switching threshold fixed definition max. 30 VDC max. 1.5 ma >3.5 V (high) <1.0 V (low) Digital Outputs (slimline EC only) Function Type of output Output voltage Output current fixed definition Open Drain p-kanal MOSFET max. 30 VDC max. 100 ma Communication Interface (slimline RS) to connect to a Test Controller Standard Data format Protocols RS-485, 2-wire 8e1 Local-Bus: 115200 bps up to 48 Mbps Modbus-RTU, ASCII: 19200 bps up to 115200 bps Host Interface Ethernet (slimline EC only) Protocols TCP/IP, UDP, PING, ASCII, Modbus TCP/IP Services DHCP, FTP-Server, FTP-Client, e-mail-send-client (SMTP) Baud rate 10/100 Mbps Data rate max. 800 kbyte/s Number of simultaneous Clients 10 Host Interface EtherCAT (slimline EC only) Standard Ethernet Number of channels 1024 Byte read and write data, 254 variables Baud rate 100 Mbps Cycle time 100 µs Isolation voltage 500 V

Slave Interfaces RS 485 (slimline EC only) to connect further slimline RS, see Connection Diagram Number of interfaces 3 Standard RS 485 Data format Protocol Baud rate Connectable devices Isolation voltage 8E1 Local Bus 9.6 kbps up to 24 Mbps max. 16 modules at one UART line 500 V Data Memory (slimline EC only) RAM Flash 16 MByte (optional 90 MByte), cycle buffer 128 MByte Synchronization of a Multi Device System (slimline EC only) Interface RS485 Standard Mode Master Slave principle, IRIG standard DCF77, AFNOR etc, GPS over IRIG standard GPS NMEA over RS232 SNTP over Ethernet Power Supply Power supply Power consumption slimline RS Power consumption slimline EC Influence of the voltage 10 up to 30 VDC, overvoltage and overload protection approx. 10 W approx. 15 W <0.001 %/V Mechanical Type Dimensions (W x H x D) Protection system 19 Standard, 1 unit (444 x 44 x 260) mm IP20 Environmental Operating temperature Storage temperature Relative humidity -20 C up to +60 C -40 C up to +85 C 5 % up to 95 % at 50 C, non condensing PAC Functionality (slimline EC only) Cycle time Processing 1 ms cyclic or synchronized with data acquisition

Programming Tool test.con Using test.con for programming of the PAC-function in a graphical way: Warm Up Time All declarations are valid after a warm up time of 45 minutes. Valid from Mar. 2016. Specification subject to change without notice DB_Q.raxx_A107-16SL_E_23.docx