RED DIAMOND SHINGLES Roof Installation Introduction:

Similar documents
Turada Hardwood Shingles and Shakes Installation instructions

eco-shake INSTALLATION INSTRUCTION

PROJECT INSTRUCTIONS Roofing

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

ROOFING City of Grand Rapids Building Safety Division

ROOFING APPLICATION STANDARD (RAS) No. 130

Installation Guide. Cedar Shake. Distributed by: BEST MATERIALS LLC, Phoenx AZ

DIRECTIONS FOR APPLICATION

DIRECTIONS FOR APPLICATION

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

DIRECTIONS FOR APPLICATION

SECTION WOOD SHINGLES

Brava Old World Slate Installation Guide

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

A P P L I C A T I O N I N S T R U C T I O N S

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Slate Shingle Specifications

Inspire Aledora Slate Application Guidelines

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

b) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

Wood shakes and wood shingles

Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"

Installation Guide. Titan Old World Slate REV Titan Manufacturing Phone: (407) Fax: (866)

BARRELL VAULT BATTENLESS

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

Tapersawn Shake Installation Instructions

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

COMPOSITE SIDING INSTALLATION GUIDE

PREMIUM LAMINATED ASPHALT SHINGLES Frederick, MD

ENGINEERED SLATE 2018 INSTALLATION GUIDE

6 STEP INSTALLATION GUIDE BY DCI

Barrel Vault Counter Batten and Batten

SmartVent Eave Edge Installation Instructions

Multi-Width Slate. Single-Width Valoré Slate Widths: 12"

Steel Shingle Installation Guide

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

4. Metal roof jacks at penetrations and attachments

AIA Specification. Section Slate Shingles PART 1 GENERAL

Ekoroof LiteTile Dimensions

DaVinci SlateTM INSTALLATION

3-Tab Shingle Installation Instructions

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

Application Guidelines - Slate General Information

HERITAGE LAMINATED ASPHALT SHINGLES Tuscaloosa, AL

Laminate Shingle Installation Instructions

Cambridge English Application Instructions

INSTALLATION GUIDE SLATE NOTE TO INSTALLER

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

9Upgrades to Windproof Your Roof

Application Guidelines - Shake General Information

Installation Instructions

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

Installation Guide. Shingles. Classical. Shingles. Warning. Storage. Cutting Shingles. Touch-Up. Eastern White Cedar

Installation Instructions

LAMINATED SHINGLES CERTAINTEED SHINGLE APPLICATOR S MANUAL SUPPLEMENT

B. Related Sections: The following Sections contain requirements that relate to this Section:

METRO PANELS (EXPOSED

DECRA Shingle Installation Guidelines

SECTION ASPHALT SHINGLES

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Shingle Installation Guidelines

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

Shapes Siding. Perfection Shingles. Chalk Line

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION ASPHALT SHINGLES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

New Roof Construction R MANUAL

GlassMaster General Instructions - Ardmore, OK & Hampton, GA <br /> Atlas Roofing

NT3. Figure 3. Fasten HardieTrim Flat Tab to minimum 7/16" OSB with min 2, 6d

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

SHAKELITE & SLATELITE 1

HardieTrim NT3 TM board is a decorative non-load bearing trim product. Figure 3. Fasten HardieTrim Flat Tab to minimum 7/16" OSB.

SECTION 9: ROOF STRUCTURE, ROOFING MATERIALS AND FLASHING, GUTTER, DOWNSPOUTS, AND SKYLIGHTS. Background

Installation Instructions

INSTALLATION GUIDE SHAKE N OTE TO I NSTALLER

C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)

New Roof Construction R M A N U A L

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

Application instructions

Five Star Panel Installation Instructions

Installation Instructions

installation guide Villa

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

Oklahoma Uniform Building Code Commission 2401 NW 23 rd, Suite 2F Oklahoma City, OK Phone: Fax:

RIDGEMASTER PLUS CAUTION INSTALLATION INSTRUCTIONS ALWAYS WEAR SAFETY GLASSES TOOLS NEEDED GENERAL GUIDELINES FOR RIDGEMASTER PLUS AND HIPMASTER

Transcription:

RED DIAMOND SHINGLES Roof Installation Introduction: The guidelines set forth in this manual are intended for use with the application of Red Diamond shingles. Wallaba specie (Eperua Falcata) shingles manufactured by Walligna LLC and distributed by FLW Wood Products, Inc. are labeled with the Red Diamond brand name. We have utilized many sources in order to provide you with various construction techniques and methods that are technically sound and conform to most building code requirements. The specifications in this guide apply to the installation of Red Diamond roofing shingles. While the information contained in this guide is informative, it is not intended to supersede municipal building codes. Consult your local building code official for proper preparation and installation requirements unique to your municipality. Product Warranty: Walligna LLC provides a 50-year limited manufacturer s warranty for Red Diamond shingles. The product warranty covers Premium Grade and Number 1 grade materials only. Failure to comply with local building codes will void any warranty. Uses: Red Diamond shingles are used for roofing and sidewall applications where a premium wood shingle product is preferred. Description: Sawn on both sides for a uniform tailored appearance, Red Diamond 18 shingles feature a ½ inch butt thickness tapered to ⅛ inch and comes in random widths from 4-10 inches. Red Diamond shingles are graded in accordance with CSSB-97 and the UBC 15-4 standard for wood shingles. To enhance the longevity of the shingle, we recommend that the shingles be installed over a ventilated roof deck. Red Diamond shingles are perhaps one of the densest natural wood shingles available, providing decades of strength and protection in various climates. However, even with their increased density Red Diamond shingles may be cut with a chop or jig saws or with a utility knife at the tapered end. General Guidelines - Shingle Application: Regardless of style, the following basic application details apply. Install flashing and metal drip edge. Shingles must be doubled or tripled at all eaves and installed in straight single courses butts of first course shingles should project 1½" beyond the fascia and minimum 3/4 beyond gable end. Spacing between adjacent shingles (joints) should be a minimum of 1/8" and a maximum of 1/4". Joints in any one course should be separated not less than 1 ½" from joints in adjacent courses; and in any three courses, no two joints should be in direct alignment. Underlayment shall be minimum No. 30 perforated asphalt-saturated felt conforming to ASTM D226. Fasten one ply No. 30 felt to deck with sufficient nails to hold in place. Side laps should be a minimum 2 inches and end laps a minimum of 6 inches.

Fasteners All fasteners used to attach Red Diamond shingles shall be corrosion resistant 0.090-0.092 stainless steel type 304 ring shank blunt diamond tip fasteners. The use of 316 stainless steel ring shank blunt diamond tip fasteners is recommended if within 15 miles of salt water. The fasteners utilized shall be of sufficient length to penetrate ¾ of an inch into the sheathing; if sheathing is less than ½ inch, fastener shall fully penetrate the sheathing. If utilizing pneumatic nailers, set pressure to 100 psi. Please account for a pressure drop of 5 psi for every 50 ft. of hose. Whether you are utilizing a hammer or pneumatic nailer, be sure to drive the fasteners flush with the shingle surface. Note: Over driven fasteners can be detrimental to the shingles. Do not over drive fasteners. Care should be taken to drive fasteners flush to the wood surface without crushing the wood surface or over penetrating the nail head. Underlayment: Type D-226 #30 Roofing Felt; or Self- Adhering Water Proofing Underlayment (Ice & Water Shield) Red Diamond - Shingle Installation Shingles shall be doubled or tripled at eaves and installed in straight rows or courses. A side lap of 1 ½ inches and should project beyond the fascia and approximately 1 1 ½ inches over the gable end. Spacing between shingles shall be a minimum ⅛ inch to a maximum ¼ inch. Shingles shall be laid with a side lap not less than 1 ½ inches between joints in courses and no two joints in any three adjacent courses shall be in direct alignment. Fasten shingles to the roof sheathing with two fasteners per shingle positioned between ¾ inch 1 inch from the edge and no more than 1 inch from the exposure line. Fasteners for Red Diamond shingles shall be 304 stainless steel ring shank diamond tip nails with sufficient length to penetrate ¾ inch into the sheathing. Type 316 stainless steel ring shank diamond tip fasteners shall be used if with 15 miles of salt water. Weather exposure for 18 Red Diamond shingles shall not exceed 5 ½ inches on roofs. Note: DO NOT USE Electro Galvanized Fasteners.

Spaced Sheathing over Solid Decking: Shingles shall be installed on solid or spaced sheathing. In regions where wind driven precipitation is a concern utilizing spaced sheathing, over solid decking is good practice. Fasten minimum ½ -inch exterior grade plywood to the rafters. Then apply appropriate underlayment over plywood deck per applicable building code. A bituminous eaves membrane is applied to the solid sheathing and extends 24 inches inside of interior surface of exterior wall. Attach minimum 1 x 4 battens vertically from the eaves to the ridge. The vertical battens shall be fastened 16 on center to the rafters with fasteners of sufficient length to penetrate ¾ of an inch into the rafter through the underlayment and plywood deck. Where spaced sheathing is used, sheathing boards shall not be less than 1 x 4 ; furring strips shall be spaced on centers equal to the weather exposure to coincide with the placement of fasteners. (Weather exposure for 18 Red Diamond shingles shall not exceed 5 ½ on roofs.)

Flashing: At the juncture of the roof and vertical surfaces, flashing and counterflashing shall be provided in accordance with the manufacturer's installation instructions, and where of metal, shall not be less than 0.019-inch (0.48 mm) stainless steel /corrosion-resistant metal. Be sure to consult with your local code official for corrosion resistant metal flashing best suited for your region. The valley flashing shall extend at least 11 inches (279 mm) from the centerline each way and have a splash diverter rib not less than 1 inch (25 mm) high at the flow line formed as part of the flashing. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). For roof slopes of three units vertical in 12 units horizontal (25- percent slope) and over, the valley flashing shall have a 36-inch-wide (914 mm) underlayment of either one layer of Type I underlayment running the full length of the valley or a self-adhering polymer-modified bitumen sheet complying with ASTM D 1970, in addition to other required underlayment installed over the sheathing and under the metal valley. 12 units horizontal (58-percent slope) or self-adhering polymer-modified bitumen sheet shall be installed. Metal valleys should be center-crimped, painted, galvanized steel, stainless steel or aluminum and should extend no less than 11 inches on each side of the valley centerline. In some areas, however, flashing width requirements may vary; be sure to consult the local building code officials. Take note that when applying shingles the grain should not be parallel to the centerline of the valley and those extending into the valley should be cut at the proper angle to ensure proper drainage. In areas where the average daily temperature in January is 25 F (-4 C) or less or where there is a possibility of ice forming along the eaves causing a backup of water, the metal valley flashing underlayment shall be solidly cemented to the roofing underlayment for slopes under seven units vertical in Figure 7c: Typical Saddle Flashing

Where saddles or crickets are formed in back of chimneys, curves or similar vertical surfaces, they shall be carried not less than 10" under the shingles. Where vertical surfaces intersect with slopes such as chimneys etc. step flashing shall be used. They shall be constructed of individual pieces and shall extend horizontally not less than 3 inches and up the vertical wall. They shall be lapped by the counter flashing not less than 4 inches. Installed in step fashion, each piece shall lap not less than 3 inches (one flashing installed on each course concealed under the covering course). If other than masonry is used, the flashing shall extend up the wall not less than 3 inches behind the sheathing paper. Dormer flashings shall run 3" up under the sheathing paper and not less than 3" horizontally. Window caps and all other projections at points where rain water accumulates must be provided with flashings; such flashings must extend a distance of at least 3 inches up the wall behind the sheathing paper.

Hip & Ridge Caps To protect against water penetration, the intersecting joints at the hips and ridges should be capped. Regardless as to where the caps are manufactured, constructed on site or factoryassembled, hip and ridge caps must have alternating overlaps and the fasteners must be covered by the overlying unit. It is important to note that when manufacturing hip and ridge caps with roofing shingles of similar length and grade, the weather exposure will remain the same. Fasteners must be longer than those used to fasten the shingles to the roof deck and be of sufficient length to penetrate 3/4" into or completely through the sheathing. Install a strip of felt, eave protection material or corrosion resistant metal over hip or ridge under the ridge or hip cap courses. Venting Check with your local building official for requirements in your area. The amount of venting required varies with roof size, structural configuration as well as geographic, seismic and climate conditions. Where wind driven snow is prevalent, the proper ridge ventilation product should have a screens to prevent snow and insect infiltration at soffit vent and ridge vent (not louvered or baffled). Proper care and maintenance: Keep roof clear and clean. Be sure to prune low hanging branches and remove excess debris that may accumulate on roof surface. Rinse debris from roof surface with garden hose pressure less than 100 PSI. Class A Fire Rated Installation: Red Diamond Hardwood Shingles are a Class A roof assembly when installed per the guidelines set forth in this section. The roof deck shall be minimum 1/2 inch thick exterior grade plywood or 1 x 6 TG spaced sheathing. Georgia Pacific DensDeck minimum, ½- inch-thick roof board shall be applied over the sheathing with underlayment applied over the DensDeck. Red Diamond shingles shall be installed over the underlayment with fasteners of sufficient length to penetrate through the DensDeck material and into the roof sheathing a minimum of ¾-inch. The remainder of the installation shall be in accordance with the installation requirements for wood shingles in IBC Section 1507.8, IRC Section R905.7 or UBC Section 1507.13.