Astigmatism Particle Tracking Velocimetry for Macroscopic Flows

Similar documents
Figure 1: A detailed sketch of the experimental set up.

Bias errors in PIV: the pixel locking effect revisited.

IMAGE FORMATION. Light source properties. Sensor characteristics Surface. Surface reflectance properties. Optics

Measurements of Droplets Spatial Distribution in Spray by Combining Focus and Defocus Images

Particle Image Velocimetry

Better Imaging with a Schmidt-Czerny-Turner Spectrograph

Optical design of a high resolution vision lens

Exercises Advanced Optical Design Part 5 Solutions

ECEN 4606, UNDERGRADUATE OPTICS LAB

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams

MULTIPLE SENSORS LENSLETS FOR SECURE DOCUMENT SCANNERS

Be aware that there is no universal notation for the various quantities.

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

Tutorial Zemax Introduction 1

Vision Research at. Validation of a Novel Hartmann-Moiré Wavefront Sensor with Large Dynamic Range. Wavefront Science Congress, Feb.

Performance Factors. Technical Assistance. Fundamental Optics

Laboratory experiment aberrations

Solution of Exercises Lecture Optical design with Zemax Part 6

Aberrations and adaptive optics for biomedical microscopes

( ) Deriving the Lens Transmittance Function. Thin lens transmission is given by a phase with unit magnitude.

Simultaneous planar measurement of droplet velocity and size with gas phase velocities in a spray by combined ILIDS and PIV techniques

Understanding Optical Specifications

Design of a Lens System for a Structured Light Projector

Practical Flatness Tech Note

TSBB09 Image Sensors 2018-HT2. Image Formation Part 1

Testing Aspheric Lenses: New Approaches

Improving the Collection Efficiency of Raman Scattering

Design Description Document

Study of self-interference incoherent digital holography for the application of retinal imaging

Mirrors and Lenses. Images can be formed by reflection from mirrors. Images can be formed by refraction through lenses.

Overview. Pinhole camera model Projective geometry Vanishing points and lines Projection matrix Cameras with Lenses Color Digital image

Collimation Tester Instructions

Exam Preparation Guide Geometrical optics (TN3313)

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

IMAGING TECHNIQUES FOR MEASURING PARTICLE SIZE SSA AND GSV

End-of-Chapter Exercises

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Instructions for the Experiment

Chapter Ray and Wave Optics

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Imaging Optics Fundamentals

Waves & Oscillations

Big League Cryogenics and Vacuum The LHC at CERN

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

OPTICAL SYSTEMS OBJECTIVES

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Single Camera Catadioptric Stereo System

1 st IFAC Conference on Mechatronic Systems - Mechatronics 2000, September 18-20, 2000, Darmstadt, Germany

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Geometric optics & aberrations

A novel solution for various monitoring applications at CERN

Exercise 8: Interference and diffraction

AST Lab exercise: aberrations

PIV STUDY OF STANDING WAVES IN A RESONANT AIR COLUMN

Error quantification of particle position estimation on colour images for Particle Tracking Velocimetry

Sensitive measurement of partial coherence using a pinhole array

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Chapter 18 Optical Elements

Acquisition. Some slides from: Yung-Yu Chuang (DigiVfx) Jan Neumann, Pat Hanrahan, Alexei Efros

The diffraction of light

CHAPTER 1 Optical Aberrations

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

LENSES. INEL 6088 Computer Vision

GENERATION OF SPATIAL LIGHT DISTRIBUTIONS

TECHSPEC COMPACT FIXED FOCAL LENGTH LENS

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

Exercise questions for Machine vision

Use of Computer Generated Holograms for Testing Aspheric Optics

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

Lens Design I Seminar 1

MASSACHUSETTS INSTITUTE OF TECHNOLOGY. 2.71/2.710 Optics Spring 14 Practice Problems Posted May 11, 2014

The optical analysis of the proposed Schmidt camera design.

Sensors and Sensing Cameras and Camera Calibration

REAL TIME SURFACE DEFORMATIONS MONITORING DURING LASER PROCESSING

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Opto Engineering S.r.l.

Advanced Lens Design

Laser Speckle Reducer LSR-3000 Series

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

Breaking Down The Cosine Fourth Power Law

Astronomical Cameras

Announcements. Image Formation: Outline. The course. How Cameras Produce Images. Earliest Surviving Photograph. Image Formation and Cameras

Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

DETERMINING CALIBRATION PARAMETERS FOR A HARTMANN- SHACK WAVEFRONT SENSOR

Astronomy 80 B: Light. Lecture 9: curved mirrors, lenses, aberrations 29 April 2003 Jerry Nelson

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Adaptive optics for laser-based manufacturing processes

Displacement Measurement of Burr Arch-Truss Under Dynamic Loading Based on Image Processing Technology

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

ILLUMINATION AND IMAGE PROCESSING FOR REAL-TIME CONTROL OF DIRECTED ENERGY DEPOSITION ADDITIVE MANUFACTURING

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Low Contrast Dielectric Metasurface Optics. Arka Majumdar 1,2,+ 8 pages, 4 figures S1-S4

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Transcription:

1TH INTERNATIONAL SMPOSIUM ON PARTICLE IMAGE VELOCIMETR - PIV13 Delft, The Netherlands, July 1-3, 213 Astigmatism Particle Tracking Velocimetry for Macroscopic Flows Thomas Fuchs, Rainer Hain and Christian J. Kähler Bundeswehr University Munich, Institute of Fluid Mechanics and Aerodynamics Werner-Heisenberg-Weg 39, 85577 Neubiberg, thomas.fuchs@unibw.de Abstract Astigmatism Particle Tracking Velocimetry (APTV) is a three-dimensional flow measurement technique. It requires only a single camera and is therefore best suited for measurement domains with limited optical access, such as compressor and combustion research. The z-component of the spatial particle position is coded in the geometry of its particle image. In order to prove the feasibility of APTV to measure macroscopic air flows, an accuracy analysis using a pinhole matrix (pinhole diameter of 1.1±.1 µm) is carried out. Two different optical setups with different measurement depths (2-1 mm) are investigated. The relative measurement error lies in the range of.34-.46 % of the measurement depth. Altogether APTV allows for accurate volumetric velocity measurements in macroscopic air flows. 1. Introduction The simultaneous measurement of all three velocity components in a volume is of great interest in many fluid mechanical applications. Therefore several measurement techniques, based on Particle Image Velocimetry (PIV) and Particle Tracking Velocimetry (PTV), have been developed [1]. In microfluidics a well-established 3D3C measurement technique is the so-called Astigmatism-PTV (APTV) [2, 3]. This technique requires only a single camera and is thus best suited for applications with limited optical access compared to multi-camera techniques like TOMO-PIV [4]. APTV takes advantage of an optical aberration, namely astigmatism, induced by a cylindrical lens, leading to the appearance of a sagittal and a meridional focal plane. Due to this aberration, a seeding particle forms an elliptical particle image with a distinct geometry corresponding to the distance from the camera. Hence, the z-position along the optical axis of a particle is coded in the axis lengths of the elliptical particle image, whereas its x- and y-position is determined by the particle image s center. With the knowledge of the spatial positions of the particles, the velocity field is calculated by means of a tracking algorithm. The depth encoding scheme is illustrated in Fig. 1. Figure 1: Principle setup of the optical components. In the xz-plane only the spherical lens acts, whereas in the yz-plane both lenses are acting [5] In order to prove the practicability of APTV in macroscopic domains, an accuracy analysis of the particle position determination is carried out. The analysis focuses on the z-coordinate of the location, as this coordinate, along the optical axis, is the one with the lowest accuracy. The following section outlines the experimental method of the accuracy analysis followed by an analysis and discussion of the results.

2. Experimental Setup and Method For the accuracy analysis a backlight illuminated pinhole matrix (pinhole diameter: 1.1±.1 µm, vertical and horizontal displacement of the pinholes: 4 mm) is moved through the entire measurement depth in steps of z (note that the light emission behaviour of particles and pinholes is similar). At each location 2 images are recorded. Two setups with different cylindrical lenses are investigated, one with a focal length of f zyla = 5 mm (setup A) and one with f zylb = 1 mm (setup B). While the working distance (28 mm) is equal for both setups, the employment of different cylindrical lenses leads to different distances of the focal planes and thus measurement volumes. For setup A the focal plane distance is z FPA 52 mm ( z FPB is about 22.5 mm). The images are recorded with a LaVision scmos camera with an objective lens of 5 mm focal length and a f-number of 8 (setup A) and 11 (setup B). Due to the properties of the pinhole matrix (a photo mask with a very thin chromium layer with a total of 4 etched pinholes over an area of 8 8 mm 2 ), it is not possible to illuminate the pinhole matrix at an angle of degree to the optical axis. The chromium layer does not fully block the light. For this reason the laser light (2.5 W cw-laser at a wave length of 532 nm) directly illuminates the camera sensor, which is then overexposed. This makes an illumination at an angle greater than degree to the optical axis necessary. On the other hand the larger the angle of illumination is, the lower the emitted light intensity of a pinhole is, if the angular intensity distribution of light diffraction on a circular aperture is considered [6]. With an illumination angle of approximately 1 degree to the optical axis, a setup is found where a reasonable high light emission from the pinholes is provided, while at the same time the camera is in a save position. However, as a consequence the illuminated area of the pinhole matrix fills roughly half the sensor size (for setup A 852 983 pixel of 256 216 pixel, see the grey box in Fig. 3, setup B: 759 1). Another point is that the light that is not absorbed by the chromium layer also illuminates the objective lens placed in front of the pinhole matrix. This in turn causes reflections affecting the camera sensor as the chromium layer has mirroring properties. Hence, the field of view (FOV) is reduced further and the signal-to-noise ratio (SNR) of the pinhole images is decreasing. The resulting FOV for setup A is 13.1 15.1 mm 2 at z = mm changing linearly to 21.8 25.2 mm 2 at z = 1 mm. For setup B the FOV is 13.3 17.5 mm 2 at z = mm and 17.2 22.6 mm 2 at z = 5 mm. The geometry of a pinhole image does not only depend on the distance to the camera but also on its - and -position, as the focal planes are curved. In addition, distortions in the optical path (such as windows, lens imperfections etc.) have to be accounted for. Thus, it is necessary to establish a calibration function depending on the geometry of a pinhole image and the -, - and z-coordinates of the corresponding pinhole. The first step of the calibration procedure is to calculate an intensity averaged image of the 2 images recorded at each z-position. This is followed by a spline fit of the axis ratio values of the averaged pinhole images at each location. Then the - and -position of a pinhole image is determined, leading to a calibration function depending on the z-coordinate for this specific pinhole image (the axis ratio values are derived from the spline fits at every z-position). Fig. 2 illustrates the described principle. z 1 calibration function, = const. = const. z 2 axis ratio z 3 z spline fits of axis ratio values (blue) at a certain z-position Figure 2: Calibration scheme: At first axis ratio values are fitted (spline fit) at every z-position. After that a calibration curve for the - and -position of a pinhole image is established, where the depth position is determined by the axis ratio of the pinhole image (red curve). For specific - and -positions the calibration functions are given in Fig. 3 (setup A). Each the maximum and the minimum value of the axis ratios denote a focal plane. The functions are not exactly point-symmetric as with distance to the pinhole matrix the signal-to-noise ratio is decreasing, resulting in less accentuated diffraction images. Following this calibration procedure the absolute deviation, Z, of the calculated pinhole position compared to the actual position is determined at every z-position (see Fig. 4). This leads to a database of 2 pinhole images in each of the 2 recordings at every z-position (i.e. 4 pinhole images per z-position). However, it can be seen that the calibration function is ambiguous when measuring beyond the focal planes. These ambiguities can be overcome in the following way. Whereas the axis ratio has a minimum or a maximum at the focal planes, the larger axis of a particle image changes lineary near the corresponding focal plane. Thus, the length of the larger axis determines whether the particle position is within or beyond a focal plane. In the next section the results of the accuracy studies, performed as outlined here, are analyzed for setups A and B.

axis ratio ax/ay [ ] 1 1 1 position of the plotted axis ratio values on the camera sensor. Grey: entire sensor (256x216 px), white: sector of the sensor considered for evaluation (852x983 px) 1 1 25 5 75 1 Figure 3: Calibration functions at different x- and y-positions are shown for setup A. The axis ratios are derived from the spline fits at every z-position. The images are recorded with a step width of z A =.5 mm (setup A) along z. Setup B has a step width of z B =.25 mm (not shown here)..195 axis ratio ax/ay [ ].19.185 Z.18 65.3 65.4 65.5 65.6 65.7 Figure 4: z-position determination scheme: The deviation of the real depth position of a pinhole to the measured one is denoted by Z. From this deviation the measurement error is determined. 3. Results and Analysis In the following the results of the accuracy analysis, conducted as described in the preceding paragraph, are analyzed. For setup A an average measurement error of.17 mm is found between the focal planes. It is about.34 % of the measurement depth of 5 mm (see Fig. 5a). When going beyond the focal planes the average error increases to.41 mm (or.41 %) at a measurement depth of 1 mm (see Fig. 5b). Note that also the error between the focal planes increases, despite the fact that the data set is the same. This is due to an adjustment of the processing algorithm in order to be able to process the larger (therefore lower SNR) pinhole images beyond the focal planes. Fig. 5b shows the largest measurement error to be in the area beyond the focal planes, where pinhole images with low SNRs are found. At both focal planes the measurement error has peaks even though the SNRs are the largest. This can be explained by the calibration function which has a maximum or minimum at the respective focal planes. Generally, the measurement error increases with a decreasing slope of the calibration function. The measurement errors of setup B are significantly smaller. Between the focal planes an error of.7 mm occurs, being equivalent to.35 % of the measurement depth of 2 mm (see Fig. 5c). The measurement error of the entire measurement depth is.23 mm, i.e..46 % of 5 mm (see Fig. 5d). However, it would be expected that the error of setup B is higher as the amount of astigmatism is lower (focal length of cylindrical lens is 1 mm compared to 5 mm for setup A) and therefore smaller absolute axis lengths of the pinhole images occur. But in turn the light intensity emitted by a pinhole is distributed over a larger area on the sensor, leading to a lower SNR. Hence, a low SNR has a strong negative impact on the accuracy of the spatial pinhole position determination. Altogether the measurement error with respect to the measurement depth (.34-.46 %) is in a similar range. Preliminary accuracy investigations conducted with a single pinhole of 5 µm diameter show lower measurement errors. The depth position can be determined with an accuracy of.7 mm over a measurement depth of 12 mm. While the shape and size of a pinhole

image does not differ significantly between a 1 µm and a 5 µm diameter pinhole, the main reason for the higher accuracy of the larger pinhole is the higher SNR. Furthermore, the spline fit of the axis ratio values of the pinhole matrix at every z-position yields an additional error. If single pinholes of the matrix are analyzed separately (i.e. each pinhole has its own calibration function) the measurement error decreases to.1 mm compared to.17 mm for setup A. In this case the error of setup B is.5 mm (before:.7 mm). With the lower SNR of the 1 µm pinholes compared to the 5 µm pinholes minor changes in the diffraction patterns of the pinhole images are observed. The 5 µm pinhole image shows an asteroid shaped diffraction pattern (see [7] for further information) of a low intensity at both focal planes, which is observed for the 1 µm pinholes. This leads to different calibration functions near the focal planes as the brighter asteroid shaped diffraction pattern results in smaller maxima and larger minima of the axis ratio values. Hence, the calibration function in near focal regions is mainly determined by the SNR of the particle image. Between the focal planes, for both pinhole sizes, the calibration function is overlapping over a range of more than 9 % of the focal plane distance, z FP, independent of the SNR. APTV allows for high measurement accuracies in macroscopic flows compared to other similar techniques. For example, a technique employing an axicon for depth determination has a relative measurement error being more than 1 to 36 times higher [8], depending on the setup..5 1.5.4 1.25.3.2 1.75.5.1.25 5 15 25 35 45 1 3 5 7 9 (a) setup A: between focal planes (b) setup A: beyond focal planes.15.75.125.6.1.75.5.45.3.25.15 5 1 15 5 15 25 35 45 (c) setup B: between focal planes (d) setup B: beyond focal planes Figure 5: Measurement errors depending on the z-position for setups A and B. For setup A the average measurement error is.17 mm between the focal planes and.41 mm for the entire measurement depth. Setup B has a measurement error of.7 mm between the focal planes and.23 mm for the entire measurement depth.

4. Conclusion and Outlook So far APTV has not been applied to macroscopic air flows. This study gives a realistic measure of the achievable depth position determination accuracy of particles with d p 1 µm. Furthermore, the outlined calibration procedure is well-suited for the proposed applications of APTV, namely in measurement environments with limited optical access, such as combustion and compressor flows. Windows and other optical influences are accounted for and therefore a true three-dimensional calibration procedure is enabled. Nonetheless, the calibration target (i.e. the pinhole matrix) has to be improved further. A smaller lateral displacement of the pinholes would improve the measurement error as with more supporting points the spline fit at every z-position is more accurate. Increasing the pinhole diameter to gain a larger SNR for the calibration images is also helpful. Additionally, the two-step calibration procedure could be replaced by a system of equations containing all the information required. An interesting opportunity for APTV is the employment of a second camera with a slightly different viewing angle (still one optical access), where the depth position of a particle is calculated by means of triangulation. Therefore, a comparative study of TOMO-PIV and APTV is under way in order to analyze the capabilities of both measurement techniques in macroscopic flows. Acknowledgement The investigations were conducted as part of the joint research programme AG Turbo 22 in the frame of AG Turbo. The work was supported by the Bundesministerium für Wirtschaft und Technologie (BMWi) as per resolution of the German Federal Parliament under grant number 3ET213M. The authors gratefully acknowledge AG Turbo and MTU Aero Engines AG for their support and permission to publish this paper. The responsibility for the content lies solely with its authors. REFERENCES [1] Cierpka C and Kähler CJ Particle imaging techniques for volumetric three-component (3D3C) velocity measurements in microfluidics Journal of Visualization 15 (212) pp.1-31 [2] Cierpka C et al. A simple single camera 3C3D velocity measurement technique without errors due to depth of correlation and spatial averaging for microfluidics Measurement Science and Technology 21 (21) 4541 [3] Kao HP and Verkman AS Tracking of Single Fluorescent Particles in Three Dimensions: Use of Cylindrical Optics to Encode Particle Position Biophysical Journal 67 (1994) pp.1291-13 [4] Scarano F Tomographic PIV: principles and practice Measurement Science and Technology 24 (213) 121 [5] Cierpka C et al. On the calibration of astigmatism particle tracking velocimetry for microflows Measurement Science and Technology 22 (211) 1541 [6] Born M and Wolf E Principles of Optics 6 th Ed. (Pergamon Press, 198) p.417 [7] Nienhuis K and Nijboer BRA The diffraction theory of optical aberrations Physica 14 (1949) pp.59-68 [8] Snoeyink C and Wereley S Three-dimensional locating of paraxial point source with axicon Optics Letters 37 (212) pp.258-26