ETC Installation Guide

Similar documents
ETC Installation Guide

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

ETC FPZ. Irideon Series ORDERING INFORMATION GENERAL INFORMATION

ETC ORDERING INFORMATION GENERAL INFORMATION. Selador Pearl CE. Accessories

ETC. Selador Pearl. Model Description. Selador Pearl 21 (two cell) Selador Pearl 42 (four cell) Selador Pearl 63 (six cell)

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

ETC Installation Guide

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Source 4WRD. Installation and User Manual. PAR and PARNel Fixture Bodies. Version Part Number: 7067M Rev: B Released:

Fan, Eden/Northfield, GS Installation Instructions (SKU ) Packing List

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

REC Series Rack Installation Guide

Desk/Wall-Mount Rack

ETC. Source Four Mini LED. Source Four Mini Series GENERAL INFORMATION ORDERING INFORMATION. Source Four CE Mini LED / Mini LED Gallery (Body Only)

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Installation Instruction

CM543 STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

Source 4WRD HPL to LED Retrofit

LF Series Assembly Instructions

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

PERSONAL RECORD KEEPING

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

INSTALLATION INSTRUCTIONS

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

Sentinel Electronic Safe Installation Guide

Ford Pick Up Rear leaf Spring Kit Installation Instructions

Lightplane 3.5 Recessed

ETC GENERAL INFORMATION ORDERING INFORMATION. Selador Lustr CE. Accessories

MONKEY BARS OVERHEAD RACK INSTALLATION

PERSONAL RECORD KEEPING

User Instructions Multiline Otter Scoreboard Caddy Assembly

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

ETC. Fresnel Series SPECIFICATIONS GENERAL INFORMATION ORDERING INFORMATION. Source Four Fresnel SPECIFICATIONS

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

CW-Type Wall Mounted Cabinets Installation Instructions

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

LOW-PROFILE WALLMOUNT CABINETS

LAN Locker Adjustable Shelves

Preference Slimline 5536 Utility Console

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

Installation Instructions

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Media Storage Systems Fixed Media Cabinets

TOYOTA TUNDRA CARGO DIVIDER Preparation. Part Number: PT

MAKO TM CASH DISPENSER

model tsa-sa48 Sliding Crosscut Table installation guide

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

Source Four 19. Ellipsoidal Series. Source Four. Connector Designation

BEFORE YOU BEGIN Read these instructions completely and carefully.

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

End of Row Doors. Revision Number 1

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

HONDA RIDGELINE (KIT #601) Installation Instructions (to be used in addition to owners manual)

SAFETY INJURY & HAZARD

Installation Instructions

HCGG Bulk Density Sensor (BDS) Load Cell Replacement

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

3 wide x 3 deep Video Wall Display Installation Guide

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

Custom Wood Frame Overlay for Glass Doors Installation Instructions

Sliding Crosscut Table installation guide

INSTALLATION INSTRUCTIONS. Large Flat Panel Wall Mount Model: PRO-2000 Series

NetRack. Please take a moment to make sure that you received everything that s included with your order. Each product is described below.

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

101B, 210X, ELM, VSTB Installation Manual

Preference Collection and Treatment Console INSTALLATION GUIDE

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Assembly Instructions

GARAGE DOOR WITH TORSION SPRING

Installation Instructions

Therma-Tru Door Gallery Setup Instructions Swing Unit with Hardware Kit - Hardware Part # MADGSWU15 (Swing Unit) Part # MADGHKSU10 (Hardware Kit)

1. TOOLS + MATERIALS REQUIRED

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Instructions for Prepping an Opening for SOSS Invisible Hinges

Senior Swing. Caution

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT

The Bowflex Revolution XP Home Gym Assembly Instructions. P/N: Rev ( /0 )

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

BEFORE YOU BEGIN Read these instructions completely and carefully.

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

Assembly Instructions

HO4 Surface Mount Installation Instructions Overview

Flat Panel Tilt Wall Mount (GPM-111)

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

HID PAR Series. Source Four 150W HID PAR. Connector Designation Use Suffixes below to specify Factory Fitted Connector type

Transcription:

ETC Installation Guide Unison Using this Guide This document is intended to guide you through the installation of the DRd Semi-Recessed installation kit. Reference the Unison DRd Rack Enclosure Installation Manual for instructions that are specific to the installation of the DRd rack including conduit entry, wire specification and termination, installing rack options, checking the rack installation, sealing air leaks, etc. Return to this guide to finish up the installation including setting the fan speed switch on the dimming engine, re-attaching the DRd rack door, and attaching the cover. Overview The Unison DRd Semi-Recessed installation kit provides the ability to partially recess a Unison DRd rack enclosure into a wall. Rough-in enclosure The enclosure installs into the cavity of a wall and secures directly to 2 x4 or 2 x6 construction. The installation depth of the rough-in determines how much the DRd rack will extend from the finished surface. Openings are provided on the rough-in enclosure, matching the top and bottom acceptable wire access for the DRd enclosure, allowing for convenient conduit access and wire routing. Extension rails (removable) Extension rails are provided to extend the enclosure (up to additional 2.5 inches) flush to the finished wall surface (as required) for cover attachment. These rails can be easily removed when they are not required. Cover The cover is provided to fit securely to the rough-in enclosure or extension rails as needed. When the DRd rack enclosure is installed with a Unison Battery Pack (UBPO), a knockout is provided in the cover for removal as needed. Two kits are available: Model Part Number Description DRd6-RIK 7183K1003 DRd 6 Semi-Recessed Installation kit DRd12-RIK 7183K1002 DRd 12 Semi-Recessed Installation kit Each kit ships with the following: rough-in enclosure with extension rails attached (rails are removable as needed) cover hardware including: 4 each 5/16 nuts and washers to attach the DRd rack 8 each 10-32 screws to attach the cover this installation guide Corporate Headquarters 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736 London, UK Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel +44 (0)20 8896 1000 Fax +44 (0)20 8896 2000 Rome, IT Via Pieve Torina, 48, 00156 Rome, Italy Tel +39 (06) 32 111 683 Fax +44 (0) 20 8752 8486 Holzkirchen, DE Ohmstrasse 3, 83607 Holzkirchen, Germany Tel +49 (80 24) 47 00-0 Fax +49 (80 24) 47 00-3 00 Hong Kong Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel +852 2799 1220 Fax +852 2799 9325 Service: (Americas) service@etcconnect.com (UK) service@etceurope.com (DE) techserv-hoki@etcconnect.com (Asia) service@etcasia.com Web: www.etcconnect.com Copyright 2012 ETC. All Rights Reserved. Product information and specifications subject to change. 7183M2120 Rev A Released 2012-02 ETC intends this document to be provided in its entirety. Installation Guide Page 1 of 8 Electronic Theatre Controls, Inc.

Prepare for Installation Where to Install the Rough-in The DRd Semi-Recessed installation kit is designed to allow installation of a DRd rack into a wall cavity, between 2 x4 or 2 x6 framed wall studs. The installation depth of the rough-in enclosure determines how much the DRd rack enclosure will extend from the finished surface. CAUTION: Unison DRd rack enclosures require at least 17 (432mm) of front clearance and 6 (152mm) of clearance to the left of the DRd rack door hinge from walls or other equipment to allow for installation and removal of modules after installation. DRd Rack Enclosure Specification and Installation Reference the DRd Rack Enclosure Installation Manual for rack installation details, including all mechanical, electrical and control wire requirements. Rough-in Dimensions If you do not allow this clearance, energization, operation and maintenance of your DRd rack enclosure will be significantly difficult. The dimensions in the table below are provided for the rough-in only and do not include the cover or DRd rack measurements for depth. It is recommended that you install the rough-in at least 36 (915mm) off the floor surface to ensure clear view of the user interface. The wall framing and blocking must be strong enough to hold the semi-recessed kit and DRd rack fully populated with modules, conduit and wire (approximately 140 lbs / 63.5kg). The weights noted below are specific to the rough-in only and do not include conduit, hardware, cable, rack and module weights. For accurate, application-specific, DRd rack enclosure and module weights, reference the Unison DRd Rack Enclosure Installation Manual. DRd6 kit 32.25 (819mm) DRd12 kit 41.5 (1,054mm) Both kits are 20 (559mm) Both kits are 4 (102mm) Kit Type Height Width Depth Semirecessed kit Product Weight inches mm inches mm inches mm lbs kgs DRd6 Semi-Recessed kit 32.25 819 20 448 4 102 15 6.8 DRd12 Semi-Recessed kit 41.5 1,054 20 448 4 102 19 9 Installation Guide Page 2 of 8 Electronic Theatre Controls, Inc.

Finished Installation Dimensions DRd6 kit 36 (906mm) DRd12 kit 45 (1,143mm) Both kits are 10 (250mm) The dimensions in the table below are provided as an estimation of the final installation including a DRd rack enclosure and cover. Both kits are 22 (559mm) Kit / Rack Type Height Width Depth inches mm inches mm inches mm DRd6 Semi-Recessed kit with DRd6 installed 36 906 22 559 10 250 DRd12 Semi-Recessed kit with DRd12 installed 45 1,143 22 559 10 250 Required Tools and Hardware The items listed below are required (not provided) to install the Semi-Recessed installation kit. 6 each 1/4 mounting hardware (lag bolts preferred) for securing the recessed enclosure to framing adjustable wrench to secure the DRd rack into the enclosure #10 nut driver or socket for extension rail adjustment or removal #2 Philips head screwdriver to secure the front cover during final installation Installation Guide Page 3 of 8 Electronic Theatre Controls, Inc.

Installation Mounting the Rough-in The wall frame and blocking must be strong enough to hold the Semi-Recessed installation kit and the DRd rack enclosure fully populated with modules, conduit and wire. Store the cover in a safe location for installation during final installation. WARNING: Determine where your rack will be installed. It is recommended that you install the rack at least 36 (915mm) off the floor surface to ensure clear view of the user interface. Prepare and construct framing / blocking to the rough opening dimensions specified in Rough-in Dimensions on page 2. Once installed, this product may be in contact with a wall surface in the room behind it. This could subject a person to electrical shock as well as damage the DRd if objects could be installed, nailed to, or screwed into the opposite wall surface. If this risk exists, install a suitable barrier between the recessed enclosure and the opposite wall surface. secure each side Step 5: Align the enclosure between the framed studs, ensuring it is level (flush is not required) to the surface. Locate the three screw holes provided on each side of the enclosure and secure the rough-in enclosure to the wall studs using 1/4 hardware (lag bolts recommended but not provided). Adjust or Remove the extension rails depending on the type of construction framing used for this installation. For installations utilizing 2 x4 construction, the extension rails are not required and should be removed. Remove the 10-32 nuts (four per side) that secure the rails to the enclosure. For installations utilizing 2 x6 construction, adjust the extension rails to be flush with the drywall or finished surface. Loosen the 10-32 nuts that secure the rails and adjust the rail to the required depth, then re-tighten the 10-32 nuts. Installation Guide Page 4 of 8 Electronic Theatre Controls, Inc.

Plan Conduit Entry and Wire Routing This section is specific to preparation of the DRd rack for installation into the recessed enclosure. Openings are provided on the top and bottom of the recessed enclosure, providing conduit access to the DRd enclosure. Note: Step 5: CAUTION: It may be helpful to temporarily install the DRd rack into the recessed enclosure and mark the opening. This allows for certain placement of conduit entry. Components on the bottom of the DRd rack prohibit conduit entry in certain locations. A label denoting acceptable conduit access on the bottom panel of the DRd rack defines the acceptable conduit access. Plan conduit and wire routing to the DRd rack enclosure. Reference the Unison DRd Rack Enclosure Installation Manual Wire Routing and Specification section to plan wire routing. Mark the desired conduit access (top, bottom) on the DRd rack. Be sure to read and comply with the label inside the DRd rack which details the recommended access locations for conduit entry into the bottom of the rack. Remove the power supply/dimming engine access panel to allow for better access in the top of the DRd rack enclosure while roughing-in conduit and cable. a: Loosen the two captured screws that secure the access panel. b: Gently pull the panel straight down until the top of the access panel is clear of the rack. c: Tilt the supply access panel away from the rack. d: Disconnect the three cables that are attached to the unit. For the cable bundle on the left side, squeeze the tabs on either side of the connector and gently pull the cable until it is free. For the ribbon cable connected on the right rear side, release the tabs on either side of the connector by sliding them opposite the connector then gently pull the cable free. For the two wire cable on the right side, gently pull the connector straight out. Punch holes into the planned conduit entry location of the DRd rack and install conduit fittings or insert lining materials in the conduit opening. Be sure there are minimal air gaps. Reference the Unison DRd Rack Enclosure Installation Manual, Sealing Rack Air Leaks for instruction. Wire openings must have fittings, bushings, grommets or fiche paper lining material to protect the wire and cable insulation from damage by sharp metal edges, and to prevent air leaks. Installation Guide Page 5 of 8 Electronic Theatre Controls, Inc.

Install DRd Rack Enclosure Remove the DRd rack enclosure door before installing the DRd into the recessed enclosure. Open the rack door and separate the ground cable between the rack and the door by pulling the faston tab free. Remove the screw securing the bottom of the rack. Remove the screw securing the top of the rack and the door should be free. Store the rack door and hardware in a safe location until final installation. Insert the DRd rack into the recessed enclosure. a: Angle the DRd rack top side first into the recessed enclosure first, clearing the fan grill and any conduit fittings (if any). b: Then rest the bottom edge of the DRd on the small ledge that is provided on the back pane of the enclosure. The keyholes on the rear panel of the DRd should align to the threaded studs on the recessed enclosure. Secure the DRd rack into place using four 5/16 nuts and washers provided. Tighten the hardware securely. Complete DRd Rack Installation Refer to the Unison DRd Rack Enclosure Installation Manual, to complete the DRd rack installation. Installation Guide Page 6 of 8 Electronic Theatre Controls, Inc.

Final Installation Power Supply / Dimming Engine Access Panel The power supply/dimming engine was removed from the DRd rack prior to installing conduit and termination wires. Before reinstalling this access panel you must change the fan speed switch setting. Set Fan Speed Switch Set the fan speed switch to the aft position, away from the 2-pin wire harness connector. This switch must be set prior to power up as it determines what the fan speed will be when run in a recessed rack mode. Re-install the Power Supply / Dimming Engine Access Panel Replace the dimming engine. a: Align the panel perpendicular to the enclosure. b: Align the guide pins into the top of the guide slots on the DRd. c: Slide the panel down the guided slots. Reconnect the three cables to the panel: Step 5: a: For the cable bundle on the left side, push the cable into the connector. The black wire will be closest to you and the blue will be farthest away. The first and sixth pins are flat on one side to prevent the cable from being connected the wrong way. b: For the ribbon cable on the right rear side, gently push the cable into the connector. The tabs on the sides of the connector will close when the cable is properly connected. The ribbon cable has a small tab to prevent it from being connected the wrong way. The tab will be toward the rear of the enclosure. c: For the two-wire cable on the right side, gently push the connector straight down. The black wire will be toward the right side of the rack, and the red will be toward the left. Rotate / tilt the dimming engine toward the rack enclosure. Gently push the dimming engine up. Tighten the two captured screws to secure the panel to the rack. Installation Guide Page 7 of 8 Electronic Theatre Controls, Inc.

Install DRd Rack Door Use whichever sequence you prefer to re-attach the DRd rack door to the enclosure, ensuring the top screw and bottom screw, as well as the ground spade are re-installed. The following sequence has proven to be successful. Align the door to the enclosure in the closed position. The top and bottom hinge brackets should be aligned over the screw holes. Note: The DRd enclosure and rack door are provided with magnets that help maintain the door in a closed position during unlocked operation. DO NOT rely on this magnet to hold the door when it is unassisted and unattached. Install the top and bottom screws. Re-attach ground spade to its receptacle on the rack door. Install Semi-Recessed Finished Cover The finished cover for this installation kit simply installs over the DRd rack, securing with screws directly to the rough-in enclosure or the extension rails, if they are used. Note: Before attaching the cover, notice that its is provided with a removable panel located on the lower right hand corner. Remove this panel (similar to a knockout) ONLY if the DRd rack is installed with a Unison Battery Pack (UBPO). Attach the cover using the eight 10-32 screws provided. Installation Guide Page 8 of 8 Electronic Theatre Controls, Inc.