COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Similar documents
36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

079 : 2000 CEB STANDARD ALUMINIUM BINDING WIRE

001: 2007 CEB STANDARD

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

015 : 1993 CEB STANDARD

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

POTENTIAL TRANSFORMER

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

TECHNICAL SPECIFICATION

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

50-SDMS-01 SPECIFICATIONS FOR

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

CAPACITOR VOLTAGE TRANSFORMER

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

Technical Specification For 33 KV, Single Phase, Dead Tank Type Out Door Current Transformer Of Different Ratio

071-3: 2009 CEB SPECIFICATION

General Electricity Company of Libya

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

TECHNICAL SPECIFICATION OF 11 KV THREE PHASE FOUR WIRE, THREE CTs COMBINED METERING CTPT SET OF ACCURACY CLASS 0.5s

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

3. COMBINED TRANSFORMERS Oil-paper insulation

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

DISTRIBUTION TRANSFORMER 11 / kv

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATIONS

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

CUSTOMER SUPPLIED HIGH VOLTAGE METERING UNIT SPECIFICATION FOR 11, 22 & 33 kv

DIRECT CONNECTED STATIC POLY PHASE ENERGY METER OF ACCURACY CLASS 1

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

BUREAU OF INDIAN STANDARDS. Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Inductive Voltage Transformers. Types VEOT and VEOS

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

DISTRIBUTION TRANSFORMER kv

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

Capacitive voltage transformers

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Howard Smart Transformer Specification Guide

Capacitive voltage transformers

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

Reference Number PPS 05 - (RIC Standard: EP SP)

Reactor and inductor are names used interchangeably for this circuit device.

Combined Instrument Transformers. Types IVOKT and TMC

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

1.0 mh, 3150 A LINE TRAP

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

Maharashtra State Electricity Distribution Co. Ltd.

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

Maharashtra State Electricity Distribution Co. Ltd.

VI 3 - i TABLE OF CONTENTS

SI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical

MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. TECHNICAL SPECIFICATION FOR. 36 kv (PROTECTION CUM METERING) INSTRUMENT TRANSFORMERS

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

User s Manual For CT Model IMB

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Basic Principles and Operation of Transformer

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

SPECIFICATION No SS-88/5 630 kva, 30 / 0.4 kv THREE-PHASE TRANSFORMERS WITH ON-LOAD TAP CHANGER

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION THE ELECTRICITY (PEDE) SPECIFICATIONS FOR

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

TECHNICAL SPECIFICATIONS

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

INTERNATIONAL STANDARD

Transcription:

006: 2008 CEB SPECIFICATION COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS CEYLON ELECTRICITY BOARD SRI LANKA

Specification for COMBINED METERING TRANSFORMERS (OUTDOOR TYPE) FOR 11kV & 33kV SYSTEMS CEB Specification 006: 2008 CEYLON ELECTRICITY BOARD No 50, Sir Chittampalam A. Gardiner Mawatha, Colombo 2. Sri Lanka Telephone: 94-11- 2324471/ 8 Facsimile: 94-11-2323935

CONTENTS Page 1.0 SCOPE 2 2.0 SYSTEM PARAMETERS 2 3.0 SERVICE CONDITIONS 2 4.0 APPLICABLE STANDARDS 2 5.0 BASIC FEATURES 3 5.1 Design 3 5.2 Manufacture 3 6.0 Technical Particulars 4 6.1 Technical Particulars for Current Transformers 4 6.2 Technical Particulars for Voltage Transformers 5 7.0 QUALTITY ASSURANCE 5 8.0 MANUFACTURING EXPERIENCE 5 9.0 ADDITIONAL REQUIREMENTS 5 9.1 Terminal Markings 5 9.2 Rating Plate Markings 6 9.3 Routine Tests 10.0 INFORMATION TO BE SUPPLIED WITH THE OFFER 6 11.0 TECHNICAL LITERATURE, DRAWINGS 7 12.0 INSPECTION AND TESTING 7 13.0 ANNEX 7 A1 Guaranteed Schedule of Particulars - Current Transformer 8 A2 Guaranteed Schedule of Particulars -Voltage Transformer 9 B Guaranteed Schedule of Particulars CT/PT Unit/Housing/ Tank 10 C Non Compliance Schedule 11 1

SPECIFICATION FOR COMBINED METERING TRANSFORMERS (OUTDOOR TYPE) FOR 11kV AND 33kV SYSTEMS 1.0 SCOPE This specification covers the design, manufacture and testing of Outdoor Combined Metering Transformers for 11kV and 33kV description System of the CEB. 2.0 SYSTEM PARAMETERS (a) Nominal Voltage 11kV 33kV (b) System highest voltage 1 2kV 36kV (c) System frequency 50 Hz. 50 Hz (d) Number of phases 03 03 (e) Neutral of earthing Effective Non effective (f) System fault Current 20 ka 20kA 3.0 SERVICE CONDITIONS (a) Annual average ambient temperature 30 0 C (b) Maximum ambient temperature 40 0 C (c) Solar Radiation 1.1kW/m 2 (d) Maximum relative humidity 90% (e) Environmental conditions Humid tropical climate with polluted atmosphere. (f) Operational altitude From M.S.L. to 1900 meters above M.S.L. (g) Isokeraunic (Thunder day) level : 90 days 4.0 APPLICABLE STANDARDS The equipment and the components supplied shall be in accordance with the latest editions of the Standards specified below and amendments thereof. However the CEB Specification shall supersede these Standards in the even there is a discrepancy. (a) IEC 60044-1 (1996-12) Instrument Transformers Part 1: Current Transformers (b) IEC 60044-2 (1997-02) Instrument Transformers Part 2: Inductive Voltage Transformers (c) IEC 60044-3 (1997-02) Instrument Transformers Part 3: Combined Transformers (d) BS 4190 (2001) Steel Bolts and Nuts (e) BS EN ISO 1461 (1999) Hot dip galvanized coating on iron and steel articles. 2

5.0 BASIC FEATURES 5.1 Design 5.1.1 The outdoor combined transformer shall be designed for system highest voltage (Rated Voltage) stipulated in clause 2.0 above and are intended for metering of three phase three wire unbalanced loads using tow wattmeter principle. 5.1.2 It shall be of free standing type suitable for mounting on steel cross arms Holes shall be provided to anchor the unit on to the channel iron cross arm. 5.1.3 Windings of individual current transformers and voltage transformers shall be housed in an insulating medium of high impact resistance cast epoxy resin and then immersed in a mineral transformer oil filled steel tank. 5.2 Manufacture 5.2.1 General I. The primary and the secondary windings shall be made of high conductivity E.C. grade copper. II. III. IV. The primary terminals and connections shall also be suitable to carry the rated current specified in the schedule of prices. The secondary terminals shall be enclosed in a weatherproof terminal box with gland plates at the base of the Combined Transformers. Lifting tackles shall be provided for lifting and positioning the transformers. The Current Transformer shall have dual ratios as indicated in the schedule of prices, with provision for easy change of ratios on the secondary side. The withstand ability of the primary, the saturation of the magnetic core and the secondary characteristic shall not be less than that requested in the technical particulars (Clause Nos. 6.1 and 6.2) V. Oil level indicator, earth lug, mounting arrangements etc. shall also be provided. The metering equipment shall be hermetically sealed type and the bushing insulators shall be made of glazed porcelain or polymer. VI. VII. Cast resin Transformers shall have the core and coil assemblies cast in Epoxy Resin, which shall be suitable to withstand high thermal and dynamic stresses due to system and climatic fluctuations. Earth lug, mounting arrangements etc. shall also be provided. A pressure release valve shall be supplied for the oil tank. The design of the pressure release valve is such that no water ingress takes place on its pressure release operations. VIII. All insulation material used in the unit (external as well as internal) shall be of non hydroscopic. IX. The lid of the secondary terminal box of the Current and Voltage Transformers (metering unit) shall be provided with sealing facilities by using a sealing wire to prevent access to the unauthorized persons. X. Gasket provided with oil the Combined Transformers shall be suitable for oil tight joints and; 1. The Combined Transformers shall be of the hermetically sealed type and provided with a satisfactory lid sealing gasket. 2. The gasket shall of the good quality to maintain the sealing effect through its life span and shall prevent seeping of oil due to ageing and extreme operating temperature 3

3. Gaskets provided with the Combined Transformers shall be suitable for making oil tight joints, and there would be no deleterious effects on either gaskets or oil when the gaskets are continuously in contact with hot oil. No gaskets shall be used in which the material of the gasket is mounted on a textile backing. 4. Exterior gaskets shall be of rubberized cork material, weatherproof and shall not be affected by strong sunlight. XI. The Transformer oil shall be highly refined, PCB free, pure mineral oil, uninhabited, of a naphthenic base and meeting the requirements of BS 148:1972 or IEC 60296. 5.2.2 Bolts and nuts All steel bolts and nuts shall conform to BS 4190: 2001 the standard specified and the nuts and heads of all bolts to be hexagonal type. 5.2.3 Painting The exterior metal surface of the unit shall be treated with hot zinc spray of minimum 50 micron thickness. Then it shall be painted with a each primer of 50 micron minimum thickness and a 100 micron minimum thickness undercoating. Then it shall be painted with a gloss or semi gloss paint of minimum 50 micron thickness. The ultimate dry film thickness shall not be less than 300 microns. Alternatively, galvanized exterior metal surface as per BS EN ISO 1461 (1999) painted with a gloss or semi gloss paint of minimum thickness 50 microns is also acceptable. 5.2.4 Creepage Distance The combined transformer insulator creepage distance shall not be less than 828 mm for 33kV and 276 mm for 11 kv. 6.0 Technical Particulars 6.1 Technical Particulars for Current Transformers 11kV 33kV (a) Transformation ratios As per Schedule of Prices (b) Rated output 15VA 15VA (c) Accuracy Class Cl. 0.5 Cl. 0.5 (d) Accuracy Limit factors 1.25 1.25 (e) Rated primary current As per Schedule of Prices (f) Rated secondary current : 5 A 5 A (g) Rated Short-time Thermal Not less than Not less than Current and Duration 20kA for 1 sec. 20kA for 1 sec. (h) Rated dynamic Peak Not less than Not less than current 32.5kA 32.5kA (i) Markings In accordance with the IEC 60044 (j) Insulation Level (i) Impulse withstand voltage 75kV 170kV (ii) Power frequency withstand voltage (1min.) 28kV 70kV 4

6.2 Technical Particulars for Voltage Transformer 11kV 33kV (a) Transformations ratio 11kV / 110V 33kV / 110V (b) Rated output 25VA 25VA (c) Accuracy Class Cl. 0.5 Cl. 0.5 (d) Rated Voltage Factor 1.2 1.2 (e) Rated time Continuous Continuous (f) Markings in accordance with IEC 60044 (g) Insulation level (i) Impulse withstand voltage 75kV 170kV (ii) Power frequency withstand voltage (1min) 28kV 70kV 7.0 QUALITY ASSURANCE The manufacturer shall posses ISO 9001:2000 Quality Assurance Certification for the plant where the manufacture of Metering Current and Voltage Transformers is done. The Bidder shall furnish a copy of the ISO 9001 Quality Assurance Certificate certified as true copy of the original by the manufacturer, along with the offer. 8.0 MANUFACTURING EXPERIENCE Manufacturer should have a minimum of five years experience for manufacturing of Metering Current and Voltage Transformers. The manufacturer should submit proof documents such as supply records, the name of the purchasers, quantity sold, and the year of sale to prove that they have supplied the Metering Current and Voltage Transformers to minimum of three Electricity Utilities internationally during last five years. 9.0 ADDITIONAL REQUIREMENTS 9.1 Terminal Markings The Primary and Secondary winding terminals shall be marked clearly and indelibly on their surface or in their immediate vicinity conforming to IEC 60044. 9.2 Rating Plate markings Ratings and data of the Combined Transformers shall be provided in the name plate, which shall be weather and corrosion proof. The Name plate shall be securely attached to the side of the (lower part) Current / Voltage Transformers so that it could be easily read from the ground level when it is installed at a height of 2.5 m from the ground level. It shall consist of the following information: - (a) (b) (c) (d) (e) (f) (g) (h) Number and year of the standard adopted. Manufacturer's identification. Serial number and type designation. Rated primary and secondary currents. Rated primary and secondary Voltage. Rated frequency. Rated output and the corresponding accuracy class of current transformer. Rated output and the corresponding accuracy class of voltage transformer. 5

(i) Rated highest equipment voltage and the insulation level. (j) Rated short-time current (I th.) in ka and the rated time expressed. (k) Rated dynamic current (I dyn ). (l) Class of insulation. (m) The words "Property of CEB". 9.3 Routine Tests Routine tests conforming to IEC standard 60044-3 and following IEC Standards shall be performed and copies of the Test Certificates should be dispatched to CEB by courier prior to inspection and testing. In addition, routine tests certificates for CT and VT units shall also be forwarded to CEB. (i) Current Transformer as per clause 6.2 of IEC 60044-1 (ii) Voltage Transformer as per clause 9 of IEC 60044-2 10.0 INFORMATION TO BE SUPPLIED WITH THE OFFER. The following shall be furnished with the offer. (a) Catalogues describing the equipment and indicating the model number. (b) Literature describing the operational features of the equipment. (c) Constructional features, materials used for components and relevant technical literature. (d) Complete dimensional drawings. (e) Magnetization and core loss curves (f) Performance certificate with regard to manufacture, supply and utilisation of the metering transformers of similar type and design quoted. (g) Manufacturing experience as per Clause 8.0 (h) Rating plate details. (i) ISO 9001 Quality Assurance Certification. (j) Completed Guaranteed Schedule of Particulars (ANNEX A1, A2 & B). (k) Type Test Certificates - The Test Certificates and Performance Curves of the Type Test performed conforming to the IEC 60044-3. The test certificates shall clearly identify the equipment concerned, showing the manufacturer's identity, type No. and basic parameters, and shall be from an internationally recognized independent testing authority acceptable to the purchaser. Following Type Test reports shall also be submitted. (a) (b) (c) (d) (e) (f) Wet test for outdoor type transformers. Lightning impulse test. Temperature rise test. Short circuit withstand capability test Short-time current tests (for Current Transformer). Tests for Accuracy. Failure to furnish the particulars asked for in Clause 10.0 will result in the offer being rejected. 6

11.0 TECHNICAL LITERATURE,DRAWINGS Technical Literature in English language on the installation and operation shall be supplied with each set of equipment and they shall be descriptive and self explanatory, complete with necessary diagrams and drawings. 12.0 INSPECTION AND TESTING The successful Bidder shall make necessary arrangements for pre-shipment inspection by an inspector sent by the CEB or by an authority acceptable to the CEB to carry out in his presence the necessary acceptance test of the equipment offered. Some of the tests as per section 4 of IEC Standard 60044-3 shall be selected as the acceptance tests. 13.0 ANNEX A1 - Guaranteed Schedule of Particulars - Current Transformer A2 - Guaranteed Schedule of Particulars - Voltage Transformer B - Guaranteed Schedule of Particulars - CT/PT Unit housing/tank C - Non Compliance Schedule 7

ANNEX A1 GUARANTEED SCHEDULE OF PARTICULARS - CURRENT TRANSFORMER The Bidders are required to furnish the following Particulars for each type of Current Transformer offered. ITEM DESCRIPTION UNITS DETAILS 1 Manufacturer 2 Type (metering) 3 Rated Voltage kv 4 Rated frequency Hz 5 Rated primary current A 6 Rated Secondary current A 7 Rated output VA 8 Rated insulation level i) Dry Impulse withstand voltage (1.2kV/50 s) peak Positive Wave +kv Negative Wave -kv ii) Power frequency withstand voltage kv 9 Rated short time thermal current & Duration ka & Sec 10 Secondary winding resistance at 75 C Ohm 11 Rated dynamic peak current ka 12 Creepage distance of the insulator mm 13 Protected Creepage distance mm 14 Accuracy Class 15 Rated accuracy limit factor 16 Knee point e.m.f. V 17 Special features (if any) 18 Connection drawings 19 Insulation material used for mounting. I hereby certify that the above particulars are true and correct. Signature & Seal of the Manufacturer Date: 8

GUARANTEED SCHEDULE OF PARTICULARS - VOLTAGE TRANSFORMER ANNEX - A2 The Bidders are required to furnish the following Particulars for each type of Voltage Transformer offered. ITEM DESCRIPTION UNITS DETAILS 1 Manufacturer 2 Type (metering) 3 Rated Voltage kv 4 Rated frequency Hz 5 Rated primary Voltage V 6 Rated Secondary Voltage V 7 Rated output VA 8 Rated insulation level i) Dry Impulse withstand voltage (1.2kV/50 s) peak Positive Wave Negative Wave +kv -kv ii) Power frequency withstand voltage kv 9 Rated short time thermal current & Duration ka & Sec 10 Secondary winding resistance at 75 C Ohm 11 Rated dynamic peak current ka 12 Creepage distance of the insulator mm 13 Protected Creepage distance mm 14 Accuracy Class 15 Voltage factor and rated time Sec 16 Service conditions : Such as indoor or outdoor temperature conditions, altitude, humidity, suitability for exposure to steam, vapour, fumes, explosive gases, excessive dust, salt air etc. should be stated. 17 Special features (if any) 18 For non-composite capacitor voltage transformers: (i) In a tapped bushing, the nominal Capacitance & P.f. values of C1 and C2 and the tolerance limit (ii) The maximum permissible working kv voltage on C1 19 Insulation material used for mounting. I hereby certify that the above particulars are true and correct. Signature & Seal of the Manufacturer 9 Date:

GUARANTEED SCHEDULE OF PARTICULARS COMBINED TRANSFORMER CT/PT UNIT HOUSING/TANK ANNEX B The bidders are required to furnish the following particulars for each type of CT/PT Unit offered. 1 Manufacturer 2 Rated Voltage kv 3 Rated insulation level i) Dry Impulse withstand voltage (1.2kV/50 s) peak Positive Wave Negative Wave +kv -kv ii) Power frequency withstand voltage kv 4 Creepage distance of the insulator mm 5 CT/PT Unit housing/tank material 6 CT/PT Unit housing/tank external surface i) Method of exterior surface painting ii) If Galvanized, thickness of zinc V (ii) If painted, thickness of layers and type of layers 7 Type/Material of Gasket. I hereby certify that the above particulars are true and correct. Signature & Seal of the Manufacturer Date: 10

Nom Compliance Schedule Annex C On this schedule the bidder shall provide a list of non compliance with this specification, documenting the effects that such non compliance is likely to have on the equipment s life and operating characteristics. Each non-compliance shall be referred to the relevant specification clause. Clause Non Compliance Signature of the Manufacturer and seal Date 11