Lynx. RoIP Gateway DISPATCH LYNX MOBILE. Optional serial ports provide remote control of radio configuration over the VoIP network.

Similar documents
1. INTEROPERABILITY GATEWAY DEVICES

MOTOBRIDGE IP INTEROPERABILITY SOLUTION

DX-Altus. Reaching New Heights in Radio Dispatch & Interoperability

Shaping the future. ... in FIELD COMMUNICATIONS

DX64. Digital Audio and Radio Management System RADIO DISPATCH SWITCH FOR MISSION CRITICAL NETWORKS

This is by far the most ideal method, but poses some logistical problems:

DX-Altus Reaching new Heights in Radio Dispatch & Interoperability for Mission Critical Communications

Remote Site Monitoring

IP/Console

Challenging Communication Boundaries. RoIP Gateways. Radio over IP for Optimal Analog & Digital Radio Network Performance

Quick Start Guide. RSP-Z2 Dual Channel Analog-IP Interface

ASTRO/Intercom System

Connecting radios all over the world. Mimer Parts list

Challenging Communication Boundaries. Ser i es I I

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Installation and Operation Manual

Pulse Communication Systems Pvt. Ltd. PRODUCT CATALOG

VEB Series. TCP/IP Network Matrix PA System. 32 simultaneous Audio Buses. Up to 60 Network Paging Consoles. Up to 128 Audio Output channels

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

Version 8.8 Linked Capacity Plus. Configuration Guide

Networks of any size and topology. System infrastructure monitoring and control. Bridging for different radio networks

Customer Programming Software RG-1000e (CPS RG-1000e) User Guide. June 2018 R2.2.2 v2

"Terminal RG-1000" Customer Programming Software. User Guide. August 2016 R4.3

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

ARP Radio Modem & Router Datasheet

Hytera DMR Conventional Series

Programming Parameter Guide

Radio Relay - Vocality to Vocality

Challenging Communication Boundaries. 950 Radio. Management System Series II

Programming Parameters - Feature Comparison : Rev 1

Customer Programming Software RG-1000e (CPS RG-1000e) User Guide. March 2018 R2.2.1

MAX Dispatch - Standard

Hytera Smart Dispatch

Customer Programming Software RG-1000e (CPS RG-1000e) User Guide. October 2017 R2.0

CTI Products. RadioPro IP Gateway. Installation Guide. Document # S For Version 8 Software

TELEX/VEGA SIGNALING PRODUCTS

Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex

AP-SRD100 Smart RoIP(Radio over IP) Dispatcher

Specification Sheet. MC SERIES Deskset Controllers

VC-4/4A, VC-8/8A, VC-16

JPS Interoperability Solutions Products Executive Summary

MC108A-2 RF MULTI-COUPLER USER S GUIDE

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

Mastr III P25 Base Station Transmitter Tune-up Procedure

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

Guardian and DL3282 Modem Interface Technical Service Application Note

Cisco IPICS Dispatch Console

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

DMS TRELLIS TELEMETRY DEMODULATOR

TurboVUi Solo. User Guide. For Version 6 Software Document # S Please check the accompanying CD for a newer version of this document

TSA 6000 System Features Summary

ADDENDUM 1. Bid# , Radio Interoperability System for the Sheriff's Office

Connecting radios all over the world. Mimer Parts list

Hytera SmartOne. A professional unified Communications Solution. Inter-system communication Unified dispatching Plug-in module design Open platform

MX800 BASE STATION SPECIFICATIONS

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

MOTOBRIDGE Dispatch Application Overview

OPERATING INSTRUCTIONS NETWORK INTERCOM SYSTEM AN-8000 SERIES

MODES AND PROTOCOL HANDLING

SOLUTIONS FOR AN EVOLVING WORLD RFL DSP Powerline Carrier System

SOLUTIONS FOR AN EVOLVING WORLD RFL 9508D UCC. Digital PowerLine Carrier Multiplexing System

ACCESS CONTROL CENTER RADIO ACCESS SYSTEM INTERCONNECTION

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Providing feature-rich IP communication and advanced user applications to corporate local and wide area networks CX II / 3300 CXi II

WTI-100 Simplex wireless Interface Instruction Manual

TACTICALL ICS COMPACT ALL SYSTEMS - ONE INTERFACE

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

Airmux-400 Broadband Wireless Multiplexer

Hytera DMR Trunking Pro

Kilomux-2100/2104 KVF.4 2-Channel Low Bit Rate Voice/Fax Module

MODEL 45B. Z-Patch. A Remote-Programmable, Multi-User Telephone Interconnect

GM339 & GM399 - Select V Mobile Radio Versatility & Sophistication on the Move

Networks of any size and topology. System infrastructure monitoring and control. Bridging for different radio networks

Rockwell Collins, Inc. VHF Users Manual

ACCELERATE THE FLOW OF INFORMATION WITHIN YOUR ORGANIZATION AND INCREASE PRODUCTIVITY WITH SECURE, AFFORDABLE PUSH-TO-TALK.

Use of Voter Comparators to Improve Railroad Radio Communications

VS-900 Security Intercom Systems. Architectural and Engineering Specification

OPERATING INSTRUCTIONS PACKET INTERCOM SYSTEM N-8000 SERIES

Solutions ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS. RADIO DISPATCHER FLEET PHONE APP BRIDGE

CAT-700 Repeater Controller

SNV-12 Voter Quick Reference Help Sheets

SIP Trunking Service Configuration Guide for XO

Technical Equipment Specification

Understanding PMC Interactions and Supported Features

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

MICOM High Grade Solutions

Hytera SmartOne. A professional unified Communications Solution. Inter-system communication Unified dispatching Plug-in module design Open platform

WAVE 5000 EVERY DEVICE. EVERY NETWORK. EVERY TEAM. CONNECTED LIKE NEVER BEFORE.

ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1

SEACOM. Solutions for Coast Radio Systems. R a d i o a a S y s t e m s

J kw AM Transmitter

Installation Manual Console Integration System

DRG-Series. Digital Radio Gateway. Kenwood NXDN Donor Radio (Tier-2) Interfacing Omnitronics DRG with Kenwood NXDN Donor Digital Radios (Tier-2)

A-MUX 32P DOCUMENTATION

WBS-670/680. Powerful Features and Performance. For Reliable Mobile Communications WBS-670 WBS-680

Connecting Smartphones and Radios using RoIP and the JPS VIA app

FL WLAN 24 AP XDB and RAD XDB

Portable Multi-Channel Recorder Model DAS240-BAT

Installing the IPS 4240 and the IPS 4255

25/05/2015 copyright testdvance pty/ltd 2015 Prices and specifications subject to change without prior notice.

Transcription:

LYNX MOBILE Lynx DISPATCH RoIP TM SYSTEM Gateway LYNX TM ROIP GATEWAY OVERVIEW The Lynx system provides Radio over IP (RoIP) communications interoperability between radio base stations and VoIP networked SIP phones, dispatch consoles and PC s. Lynx will network via industry standard IP, cellular and SATCOM linked networks. Lynx is designed for operations in a mobile vehicle or remote radio site environment. Lynx supports multiple simultaneous radio repeater, cross-patch, conference and intercom provides dial access to radio and conference nets from IP phones, PC s and legacy telephones. Optional serial ports provide remote control of radio configuration over the VoIP network. ROIP/VOIP GATEWAY The Lynx embedded SIP VoIP Gateway supports multiple VoIP terminal devices, such as SIP telephones, IP PBX, PC laptops and operator workstations and consoles. Dual 10/100bT Ethernet LAN connections are provided for configuring redundant VoIP communication networks without single points of failure. The Lynx system may be connected to a VoIP dispatch console running RadioNet software to create a mobile dispatch system with superior size, weight and power requirements over previous generation technology. Standard Lynx equipment includes a multi-port radio controller, SIP VoIP Gateway, client server, call manager, conference bridge and DC power for vehicle or fixed base operation. Lynx systems are available with 2 to 8 radio port capacity. A Lynx plug in option card adds dual FXO telephone lines for connecting to the PSTN. RadioNet offers a Lynx compatible line of rugged mobile PC operator terminals and headset boxes. Lynx systems are configurable via a network connected administration and maintenance PC. Lynx systems may be networked and console operators may log into any networked terminal. RADIO PORTS Lynx analog radio ports feature transformer isolated 4-wire audio, Carrier Operated relay (COR) inputs and relay operated PTT transmit control. EIA Standard Tone and E&M base control formats offers universal radio compatibility. LYNX GATEWAY REMOTE RADIO CONFIGURATION Lynx may also be equipped to support the remote configuration of radio base stations from a PC operator console GUI, including frequency, squelch disable, vehicle ID capture and more. Lynx s radio configuration messaging protocols are compatible with all radios with EIA Standard Tone, RS-232, RS-422/RS-485 serial or Ethernet radio data interface ports. LYNX POWER AND MOUNTING Lynx systems operate from 9-32 VDC vehicle power, or from 110/220 VAC power with an autoswitching external power pack. Lynx systems are available in vehicle chassis mount or 1u rack mounting configurations.

RNET S-0113 Page 2 of 6 1/20/2015 Mobile Command Post Portable Communications Remote Site Portable & Team Communication LYNX APEX 2000 Radios Routers Vehicle Communications RoIP Primary Communications Center Dispatch Consoles CONSTELLATION Dispatch Consoles Routers Radios APEX 1000 Vehicle Communications Portable & Team Communications

RNET S-0113 Page 3 of 6 1/20/2015 FEATURES AND BENEFITS LISTING 2/4 wire transformer isolated audio interfaces with software programmable I/O gain adapt to all radio types. Programmable PTT + COR signal lines provide universal compatibility with radio base station and repeater equipment. Software programmable remote radio configuration option adapts to all types of radios equipped with EIA Standard Tone, RS232/RS485 serial digital, or IP ports. Programmable remote radio configuration features include: PTT, frequency selection, squelch bypass, caller ID capture and more. VoIP Gateway interoperates radio and telephone systems with industry standard SIP PC s, communication terminals, IP phones and call manager systems Automated call routing feature allows networked user dial access to multiple radio nets, intercom nets and meet me conferences Configurable Voice detect and IP packet detect VOX transmit control modes Lynx operator terminal GUI features simultaneous monitoring/mixing of multiple channels with individual gain control, multichannel intercom, soft phone, simulcast, personalized operator screen configurations, remote radio control and more. Optional T1/E1 ISDN and quad FXO ports network Lynx with PBX, PSTN, cellular, legacy POTS or SATCOM equipment Operator may simulcast transmissions to all users, or a selected group of users, efficiently handling group and emergency communications. SIP Gateway includes standard G.7xx vocoders, jitter buffering, AGC and echo cancellation for universal VoIP terminal compatibility. Remote software and configuration updates to on board flash Dual 10/100bT LAN ports allow operation with redundant LAN networks Built in test (BIT) and remotely activated selftest facilitates high availability operation. Optional client software GUI supports multiple operator radio dispatch operations. The GUI software runs on a separate networked computer, laptop or tablet. Standard EIA control tones allow for remote control of radio base stations, including function control tones. Programmable paging tones LYNX CALL MANAGER Lynx includes an embedded call manager application supporting compatible Lynx client GUI or third party GUI software products. Lynx call manager software networks multiple Lynx system nodes, allowing operators to access all Lynx connected radios or to log in via any LANconnected VoIP terminal. The embedded Lynx call manager and web server eliminates the external server and call manager equipment typically required by WAN networked dispatch systems, or when Lynx is connected to external IP PBX telephone systems. LYNX CLIENT GUI The Lynx Client GUI allows operators to communicate via VoIP with multiple radios and telephones and to set up radio-radio patches and intercom nets. The Client GUI will run on any laptop, computer or workstation supporting standard JAVA scripts. RadioNet offers Lynx client GUI software customized to specific project requirements.

RNC-Lynx Page 4 of 7 7/27/2017 LYNX MOBILE VOIP COMMUNICATIONS CONSOLE Personalized GUI screens and access rights to specific conference nets, intercoms or radios are loaded to each MCC upon operator log-in. Incident-specific GUI Screens, function keys and user access privileges are downloadable into each MCC. MCC FEATURES LISTING LYNX MCC CONSOLE The Lynx Mobile Communications Console (MCC) manages operator communications with multiple networked radio, telephone and intercom users in mobile vehicle environments. The MCC LCD/keyboard user interface is software programmable, including 5 function keys, radio and softphone control GUI s. The MCC console may be operated in LCD touch screen, mouse/keyboard or in key driven cursor interface modes. The cursor driven function keys allow operators to select a desired radio or intercom channel. The MCC operator may conference and patch radio and telephone users, make Public Address announcements and simultaneously broadcast to multiple radios and user terminals. MCC consoles include a softphone that interoperates with industry standard SIP phones and VoIP network equipment. The MCC console supports a variety of headset, microphone and speaker interfaces with hot mic or PTT operation. Programmable GUI screens button and keys Selectable left-right binaural/monaural audio Multiple operator intercom channels SIP interoperable softphone Push to talk (PTT) or hot mic operation Multi party meet me conferencing Radio and telephone call patching Simulcast one-to-many broadcast capability Power for ANR headsets and electret microphones Remote configuration and administration Personalized operator GUI screen 9-32 VDC @ 12W vehicle power or AC brick Optional PoE (Power over Ethernet) LCD display brightness control Internal microphone and speaker Water resistant IP65 (water stream) protection LYNX- LED DISPLAYS The LMCC console GUI configuration and user access privileges may be programmed remotely over the IP network by the System Administrator. The Lynx front panel includes individual channel transmit and receive active displays, power lamp, LAN carrier and LAN active LED s.

RNC-Lynx Page 5 of 7 7/27/2017 LYNX I/O INTERFACE SPECIFICATIONS AUDIO SIGNAL AUDIO SIGNAL AUDIO SIGNAL Line Inputs Line Outputs Line In Line Out Up to 12V pk-pk, 1V typical, balanced 600/10K ohm transformer isolated and transient protected inputs. DB-15 connector. 0-10V pk-pk, 600/150 ohm balanced transformer isolated and transient protected outputs. DB-15 connector. Audio Bandwidth BW Bandwidth 150Hz-3.4Khz, +/- 1db. RADIO CONTROL RADIO CONTROL RADIO CONTROL COR Inputs XMIT Control Outputs COR XMIT Contact closure or signal logic input levels. Inputs pulled up to +5VDC through a 51k resistor. DB-15 connector. Normally Open relay contact closure. DB-15 connector. TRC tones TRC EIA standard control tones Radio Control Serial Ports Serial Digital RS232/RS485 RRC 9,600bps 115.2Kbps. RS232 serial ports. Rx, Tx, signal ground. RS-485 or RS-422 2/4 wire serial port. DB-15 connector. - Manual frequency entry - Squelch - Scan/select channel presets - Caller ID COM NETWORKS COM NETWORKS COM NETWORKS Dual 10/100bT Ethernet 10/100bT IEEE STD 802.3 10/100bT Ethernet LAN. RJ45 connectors. FXO ports FXO Meets global standards for FXO operation. RJ11 connectors PRI ISDN T1/E1 RS-232 Maintenance Port POWER T1/E1 RS-232 DESIGNATION Primary Rate ISDN T1/E1 option meets global standards for ISDN T1 and E1 operation. RJ48 connector 9,600bps 115.2Kbps RS-232 serial port. Rx, Tx, signal ground. DB-15 connector. SPECIFICATION Power 12/28 VDC 9-32 VDC at 8 WATTS. Industry standard Mobile Radio Connector MODEL DIMENSIONS AND WEIGHT POWER Lynx 4/8 10.1 (257mm) L x 6.1 (155 mm) W x 1.7 (43.2 mm) H, 2.25lb (1Kg.) 9-32VDC @ 8 Watts LMCC Operator Console 10.0 (255 mm) W x 6.3 (160 mm) H x 2.0 (50 mm) D, 3.25lb (1.7Kg.) 9-32VDC @ 12 Watts

RNC-Lynx Page 6 of 6 7/27/2017 SPECIFICATION Storage Temperature Operating Temperature Vibration Shock Operating and non-operating (storage) humidity EMI PARAMETERS -55 0 C to 85 0 C -30 0 C to 60 0 C 5 ~ 500 Hz 4.5G RMS random vibration 30 G peak acceleration, 11 msec. duration 0 to 95% non-condensing FCC part 15 class A, CSA, CIC, EN55022: 1994 Class A, EN55024: 1998 + A1:2001 + A2:2003, Reliability 125,000 Hours LYNX SYSTEM COMPONENTS 8 Port Lynx 4 Port Lynx Lynx Mobile Communications Console LYNX FEATURE OPTIONS MODEL Lynx 1800 Lynx 1400 Lynx MCC MODEL Lynx Client GUI license, xxx = seat capacity Quad FXO and PRI ISDN T1/E1 option card LCG-xxx QFXT1 Specifications Subject to Change without Notice 2008 2017, RadioNet Corporation, All Rights Reserved US patents 8,442,506 and 9,154,630 Constellation and Apex are registered trademarks of RadioNet Corporation