Fieldbus Isolating Repeater Series 9185/11

Similar documents
Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Binary Output Series 9175

Binary Output without Power Supply Series 9176

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolating Repeater Input Series 9163

Isolators A3/1.

Isolators A3/1. Vibration Transducer Supply Unit Series

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Isolators A3/1.

Analog Universal Module HART for Zone 2 Series 9468/33

Remote I/O. 74 Remote I/O. Remote I/O System

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Digital Input Output Module for Zone 2 Series 9470/33

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Digital I/O Coupler (4-wire) Series 9413/21

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Single-Channel Safety Barriers Series 9001

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Signal Beacon - LED Series 6162

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Motor Protection Circuit Breaker Series 8146/5-V27

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Field indicator for current loops with HART communication Models DIH50, DIH52

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Inductive sensor slot-type SI2-K08-AP7

Temperature Measurement

Temperature Measurement Transmitters for mounting in sensor head

Temperature Transmitter itemp RTD DIN rail TMT 127

Assembly. Front view. Switch Power Rail

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

SINEAX TI 807 Passive DC signal isolator

Temperature transmitter itemp PCP DIN rail TMT 121

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature Measurement Transmitters for mounting in sensor head

Technical Data. General specifications. Rated operating distance s n 3 mm

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

0 2 1 â Ó. itemp HART TMT182. Technical Information

Assembly. Front view. Switch Power Rail

Head mounted Temperature Transmitter TF02/TF02-Ex

Field indicator for current loops with HART communication Models DIH50, DIH52

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Assembly. Front view. Parametrization interface. Power Bus

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature Measurement

Temperature Measurement Transmitter for field mounting/field indicator

Resistance thermometer Model TR30, compact design

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Actuators Series 8602/3

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp

0 2 1 â Ó. itemp HART TMT182. Technical Information

Assembly. Front view. HiC2441. SL2 1b. Termination Board

itemp PA TMT184 Technical information

itemp HART DIN rail TMT112

ELECTRONIC GmbH. Optical Data Transmission OD-2M. Optical Data Transmission Range of 200 m Interbus-S (RS422)

Preset counters, electronic

SITRANS T measuring instruments for temperature

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Attachment to Certificate IECEx PTB X

Technical Information Barrier RB223

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Sicherheit, auf die Sie sich verlassen können

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Level Measurement Continuous level measurement Radar transmitters

Coriolis Massflowmeter

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Certificate of Compliance

Signal conditioner - MACX MCR-UI-UI-NC

Coriolis Massflowmeter

Flow Measurement SITRANS F M

Transcription:

www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232, RS-422, RS-485 and power supply > Transmission speed adjustable between 1.2 kbit/s and 1.5 MBit/s > Automatic setting of transmission speed for Profibus DP > Bitrefresh 09812E00 Basic function: Isolating repeater for communication signals The fieldbus isolating repeater is used to separate intrinsically safe or non intrinsically safe RS-422 / RS-485 fieldbus from non intrinsically safe RS-232, RS-422, RS-485. Suitable for intrinsically safe operation of Profibus DP (RS-485 IS). ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i x x x x Ex i x x Ex i x x x x x x Installation in x x Installation in x x Installation in x x x WebCode 9185A Isolators /1

Selection Table Interfaces field area Interfaces safe area type Order number Fieldbus isolating repeater Type 9185 RS-485 IS (PNO) RS-232, RS-422, RS-485 Screw terminals 9185/11-35-10s Explosion Protection Global (IECEx) Gas and dust IECEx BVS 06.0004X Ex na [ib Gb] IIC T4 Gc [Ex ib Db] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E 246 X E II 3 (2) G Ex na [ib Gb] IIC T4 Gc E II (2) D [Ex ib Db] IIIC Certifications and certificates Certificates Ship approval Further parameters Installation Further information Safety data Max. voltage U o Max. current I o Max. power P o of intrinsically safe fieldbus circuit Max. permissible voltage U i Internal capacity C i and inductivity L i IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cfm), Kazakhstan (TR), Korea (KCs), Russia (TR), USA (FM), Belarus (TR) BV, ClassNK, CCS, DNV GL, LR, RINA, RS in Zone 2, Div. 2 and in the safe area see respective certificate and operating instructions 3.73 V 149 ma 139 mw RS-485 IS ± 4.2 V negligible Electrical data Auxiliary power Nominal voltage U N 24 V UC DC voltage range 18... 31.2 V AC voltage range 24 V ± 15 % Residual ripple within ( 3.6V SS DC voltage range Nominal current (24 V) 66 ma Power input 1.6 W Operation LED green "PWR" Undervoltage yes (all LEDs off, all transmitters off) monitoring Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i to 1.5 kv Non-Ex i Ex i to 1.5 kv power supply acc. to standard EN 50178 Power supply to 500 V non I.S. /2 Isolators

Electrical data Field side (X3) s Terminating resistor Data transmission Safe area (X1) Data reception Terminating resistor Data reception Fault control Short-circuit data lines Indication Baud rate search Electromagnetic compatibility diagram RS-485 IS intrinsically safe, RS-422/RS-485 setting: RS-485 IS (PNO specification) and RS-485 IS (R. STAHL specification) Sub-D socket X3, 9-pole 1.2 kbit/s... 1.5 MBit/s fixes transmission speed or automatic detection > 9.6 kbit/s (only with Profibus DP) depends on transmission rate and cable to be set in external plug LED green "RxD3" RS-232 C Sub-D plug X1, 9-pole EIA RS-232 C 1.2... 93.75 kbit/s fixed transmission speed or automatic detection > 9.6 kbit/s (only with Profibus DP) ( 20 m LED green "RxD1" RS-485/RS-422 Sub-D plug X2, 9-pole EIA RS-485, EIA RS-422 1.2 kbit/s... 1.5 MBit/s Keying RS-422 transmitter on/off depends on transmission rate and cable to be connected in external plug LED green "RxD2" T ) 13 x bit time LED red "ERR" on with automatic detection: LED red "ERR" flashes Tested under the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21 for types 9185/11-35-10. Hazardous area Safe area Division 1 Division 2 Zone 1 GND Zone 2 X3 8 36 5 RS485 IS A- B+ ISP (+) ISGND 9- - 24V UC 7+ + 1 X2 RS485 RS422 8 A- A- 3 B+ B+ TxD 65 U+ GND 9 1 9 - A- 9 4 - RxD B+ X1 RS232 2 RxD 7 9 1 3 TxD 8 RTS CTS 5 GND 09816E02 Isolators /3

Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. "Installationsanleitung Schaltschrank" beachten Storage temperature -40... +80 C Relative humidity ( 95 % (no condensation) Mechanical data Screw-type terminals Spring-type terminals Single-wire connection - rigid - flexible - flexible with core end sleeves (without / with plastic sleeve) Two-wire connection - rigid - flexible - flexible with core end sleeves Weight approx. 205 g Mounting type on DIN rail (NS35/15, NS35/7.5) Mounting orientation horizontal or vertical Enclosure IP30 Terminals IP20 Enclosure material PA 6.6 Fire resistance (UL-94) V0 0.25... 2.5 mm 2 0.2... 1 mm 2 0.2... 1.5 mm 2 0.25... 1 mm 2 0.25... 2.5 mm 2 - - - - 0.5... 1 mm 2 Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Sub-D plug 9-pin for connection of the fieldbus or ServiceBus to the CPU & power module Series 9440/22 and fieldbus-isolating repeater 9185. Integrated terminator can be switched on or off. For RS-485 IS to PNOstandard. 162693 0.100 09868E00 9-pin for connection of the fieldbus or ServiceBus to the CPU & power module Series 9440/15 and fieldbus-isolating repeater 9185. Integrated terminator can be switched on or off. For non-intrinsically safe RS-485. 105715 0.001 Sub-D plug, angled 9-pin, for connection of fieldbus or ServiceBus to CPU & Power Module Type 9440/12 and fieldbus isolating r epeater Type 9185. The termination resistance is built-in. Suitable for RS-485 IS (PNO standard). 201805 0.050 12489E00 Fieldbus isolating repeater Series 9185/12 09867E00 Equipment for installation in safe areas or Zone 2 / Div. 2 For fieldbuses with RS-485 Suitable for Profibus DP, Modbus, R. STAHL ServiceBus Interface to automation system RS-232, RS-422, RS-485 Automatic setting of transfer rate for Profibus DP Adjustable transfer rate (1.2 kbit/s to 1.5 Mbit/s) Power supply 24 V AC/DC Further information see data sheet Series 9185/12 160594 0.273 /4 Isolators

Dimensional Drawing (All Dimensions in mm / inches) - Subject to Alterations X 99 mm / 3.90 " 35,2 mm / 1.39 " Screw terminals Spring cage terminals Dimension X 108 mm / 4.25 in 118 mm / 4.66 in 122 mm / 4.80 " 114,5 mm / 4.51 " 09820E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Isolators /5