DIRECT BURY SYSTEM CABLE-TIGHT WIRE MANAGEMENT SYSTEM PIPING & CONTAINMENT SUBMERSIBLE PUMPING SYSTEMS

Similar documents
EMO. Service Instruction. created by Frank Weithöner. Table of contents: Special Tools Assembling Mixing Chamber

ARCTIC TRACE INSTALLATION INSTRUCTIONS 352C Hazardous Location Water Proof Strain Relief Kit for TL Series Heating Cable

18W Nightsensor Bulkhead

BRIDLE & STILLING WELL LEVEL MEASUREMENT. FEATURING THE VEGAflex 60 SERIES

5000 Series Single Impeller Firefighter

New Product Release: October 2014 Boone Racks

ETC Installation Guide

spy pig Tracking systems

Veto spring agitator / kw burner heads

spy pig Tracking systems

Technologies, Solutions and Applications. Magnetic Level Indication and Bridle Measurements

Basic Principles and Operation of Transformer

WELD MOUNT fastening system

MODULAR TRACKER SOLAR

Thru Wall Floor Seals For New Installation

The Isolator/Surge Protector (ISP)

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Technologies, Solutions, and Applications. Magnetic Level Indication and Bridle Measurements

The Isolator/Surge Protector (ISP)

Industrial Pipe Marking

General Information...SA1-SA4

Installation & Assembly: Two Piece Suspended Ceiling Plate

IMPORTANT INSTALLATION INSTRUCTIONS ATTACHED

Holemaking Products & Accessories

Heat Exchanger Coil: Build Instructions

HZ101 & HZ121. Concealed And Low Level Cistern Installation Instructions

张家港市张运机械制造有限公司 Zhangjiagang City Zhangyun Machinery Manufacturing Co.,Ltd.

Cosmic Ray Telescope Construction Instructions for 2017 Eclipse Tracking design

Page 1 of 6 Systems Inc.

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off

RF-RR-T 24V Powered Routers/Temp Sensors

HZ301 & HZ321. Standard and Junior Flush Valve Installation Instructions

Installation Instructions

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

Operating instructions OI/FPD350-EN Rev. H. FPD350 Torbar Averaging pitot tubes

Beam and Purlin Clamps Beam Clamps

Vacuum Chuck System How I Built Mine

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance

Complete line of Holemaking Products and Accessories

ClearView Panels Mil 3 Finished Sides with Grommets 1 Hem Side Mil 3 Finished Sides with Grommets 1 Hem Side DESCRIPTION

MUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE. SF Series Submersible Solids-Handling Pumps

Installation & Assembly: Suspended Ceiling Kit

NEW APPROACH TO THE PIPE TO GUSSET PLATE CONNECTION

Assembly Instructions

Cameron MBO Multi-Bowl Wellhead System

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

PARTS LIST GALAXY FLOOR MACHINE

Innogaz Electrofusion Systems

- 1 - P/N REV E 9/15

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual

ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK 01 SME SME SME

Electrical Construction Name:

Installation & Operation Manual

Fiber Splice Box (FSB-D) Installation Instructions

Tel / (USA & CANADA) /

T S 15KVA 1PH 240/480 Transformer

Western Products, PO Box , Milwaukee, WI MOUNT KIT. Model No Ford F-150 4X

Operating Instructions for Microwave Level Switch. Model: LNM

Tylo Custom Infrared Sauna Heater Kit Installing LOW EMR Surface mount IS panels

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016

E.C. HOPKINS LTD PGO4 PEANUT GRINDER OPERATORS MANUAL AND PARTS LIST

FLIP TARP SINGLE & DOUBLE UNDERBODY TRAILERS

Installation Instructions

SOCKET & NIPPLE. Quality products for a quality environment BSP THREADED FITTINGS - PP. Code K12. Socket - equal Injection moulded.

H2-50 Hydrogen Generator Field Update

PRODUCT CATALOG Meadowview Rd Junction City, OR fax

THE GOOD GUIDE TO ELECTROFUSION JOINTING....Connect

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

Installation guide 971 SmartRadar LTi

Applications Features

Sunrise Deck Assembly Instructions for Kingston Left

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Drilling machine for use on branch saddles fused. Instructions for assembly and use

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

SECTION SWINGING AUTOMATIC ENTRANCES

WRS Artificial Lift System

D300K 3+3 SE KUBOTA PARTS LIST FOR RETURN TO MAIN INDEX

Instructions for the installation of Handy Well Pump Models HWP-E, HWP and HWP-L. **Read thoroughly before you start!**

Installing LOW EMR Surface mount IS panels in a Custom Cut Sauna TyloHelo Inc.

INSTALLATION & MAINTENANCE INSTRUCTIONS ON THE PCR-5 4 CHANNEL REMOTE CONTROL SYSTEM

ACCESSORIES. Wooden Dowels. Fasteners. Miscellaneous. Shelf Supports

K K

HBS-AP ASSEMBLING INSTRUCTIONS

TECHNICAL INFORMATION

400/480 Volt ProBlue Adhesive Melters

Optical Cable Entry Facility (OCEF) Installation Instructions

25 TONNE HYDRAULIC PRESS MODEL NO: AHP 26

TB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller)

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

Advanced Well Completion Design. 30 Sep - 04 Oct 2018, Dubai. REP logo, PMI & PMP are registered trademarks of Project Management Institute, Inc.

CLASSIC 300D Kubota PARTS LIST FOR RETURN TO MAIN INDEX

Hobart Stainless Steel Solid Wire Drums Setup Guide

Transcription:

SUBMERSIBLE PUMPING SYSTEMS PIPING & CONTAINMENT SYSTEMS CABLE-TIGHT SYSTEM DIRECT BURY SYSTEM For far too long our industry has relied on old and outdated methods of conveying cables underground our forecourts. Finally, one manufacturer has delivered the innovative, liquid-tight, vapour-tight wire management system solution we ve been waiting for. See how a solution built specifically for your needs can help your business.

CABLE-TIGHT SYSTEM The UPP brand Cable-Tight Wire Management System provides a true end-to-end solution for electrical, sensor, and data wiring containment. All of the benefits of the field-proven electrofusion welded pipework system are applied to this crucial part of the forecourt installation to ensure a fully liquid-tight underground system. Highlights Specifications Electrofusion entry seals with integrated slotted Conduit and ducting Internal bore diameters: 5mm compression grommets create a leak proof system by eliminating liquid or vapour penetration. (3mm conduit) Max vapour seal penetration in containment: 50mm Direct bury entry fittings are ideal for applications (3mm conduit) where cable of 5mm to 6mm diameter are directly buried in the ground, such as grounding wires and armored power cables. Approvals Conduit approval to AS/NZS 053.:00 Slotted compression grommet design allows wires to be positioned into place without having to pull them through each hole for significantly easier wire pulling. Direct Bury System Components Systems and their various components installed. Transition chamber with cover Double direct bury entry seal 3 Single direct bury entry seal 4 0mm ducting 5 0mm entry seal 6 3mm conduit 7 3mm entry seal 8 3mm coupler 3mm and 0mm Contained 4 6 8 7 5 3 6 8 3 Range of grommets sold separately 7

Direct Bury Wire Management System Ideal for accommodating direct bury cables requiring a liquid-tight containment entry. Direct Bury Entry Seals Direct bury entry seals are ideal for applications where cable is directly buried in the ground. Entry seals come without compression grommets. Compression grommets must be ordered separately. All compression grommet cable entries marked with maximum diameter and will accommodate a range of wire diameters (see ranges in descriptions below). Grommets not included 30-DBC 303-DBC 40800 Electrofusion single direct bury entry seal, () entry Electrofusion double direct bury entry seal, () entries Replacement compression nut for 30-DBC and 303-DBC 40807006 3 cable compression grommet - (3) 5-6mm cable entries (0 pack) Typical use: Sensors, line leak detection, interstitial tank and pipe monitoring, tank gauge wiring. Corresponding plug: 4083400 40807005 Cable compression grommet - () 7-9mm cable entry (5 pack) Typical use: Tank grounding wiring. Corresponding plug: 4083300 40807004 Cable compression grommet - () 9-mm cable entry (5 pack) Typical use: Card reader in dispenser or outdoor payment terminal wiring. Corresponding plug: 408300 40807003 Cable compression grommet - () -4mm cable entry (5 pack) Typical use: Tank or dispenser power wiring. Corresponding plug: 4083000 4080700 Cable compression grommet - () 4-6mm cable entry (5 pack) Typical use: Dispenser hook signal wiring. Corresponding plug: 408900 40807007 Blank compression grommet (0 pack) Typical use: Line integrity testing and future expansion. Cable Entry Plugs Used to seal off unused cable entries in compression grommets. 4083400 4083300 408300 408300 4083000 408900 6mm cable entry plug (0 pack) 9mm cable entry plug (0 pack) mm cable entry plug (0 pack) mm cable entry plug (0 pack) 4mm cable entry plug (0 pack) 6mm cable entry plug (0 pack) Direct Bury Installation Tools 303-CLAMP HS3 30-CLAMP HSCS Welding clamp for 303-DBC 0mm hole saw Welding clamp for 30-DBC 63mm hole saw

3mm Cable-Tight Wire Management System Ideal for accommodating single large and multiple smaller diameter cables. 3mm Conduit 00-03-00-EC-E 3mm conduit, orange, 00m coil 3mm Conduit Entry Seal Entry seals come without compression grommets. Compression grommets must be ordered separately. All compression grommet cable entries are marked with maximum diameter and will accommodate a range of wire diameters (see ranges in descriptions below). Grommets not included 30-03-EC 40800 Electrofusion entry seal, for 3mm conduit Replacement compression nut for 30-03-EC 0-03-L Electrofusion coupler, for 3mm conduit 40807006 3 cable compression grommet - (3) 5-6mm cable entries (0 pack) Typical use: Sensors, line leak detection, interstitial tank and pipe monitoring, tank gauge wiring. Corresponding plug: 4083400 40807005 Cable compression grommet - () 7-9mm cable entry (5 pack) Typical use: Tank grounding wiring. Corresponding plug: 4083300 40807004 Cable compression grommet - () 9-mm cable entry (5 pack) Typical use: Card reader in dispenser or outdoor payment terminal wiring. Corresponding plug: 408300 40807003 Cable compression grommet - () -4mm cable entry (5 pack) Typical use: Tank or dispenser power wiring. Corresponding plug: 4083000 4080700 Cable compression grommet - () 4-6mm cable entry (5 pack) Typical use: Dispenser hook signal wiring. Corresponding plug: 408900 40807007 Blank compression grommet (0 pack) Typical use: Line integrity testing and future expansion. Cable Entry Plugs Used to seal off unused cable entries in compression grommets. 4083400 4083300 408300 408300 4083000 408900 6mm cable entry plug (0 pack) 9mm cable entry plug (0 pack) mm cable entry plug (0 pack) mm cable entry plug (0 pack) 4mm cable entry plug (0 pack) 6mm cable entry plug (0 pack) 3mm Installation Tools 30-CLAMP HSCS Welding clamp for 30-03-EC 5mm hole saw

0mm Ducting DUCT-400-50 0mm ducting, blue, 75m coil 0mm Ducting Entry Seal The 0mm ducting entry seals is ideal for large bundles of cables running from the transition chamber back to the main kiosk. 304-0-TP Electrofusion entry seal, for 0m ducting 0 mm Ducting Installation Tools 305-CLAMP Welding clamp for 304-0-TP HS5 40mm hole saw Transition Chamber Built specifically for wire management, the rugged transition chamber provides an easy access point for the electrician for maintenance or future expansion. ECH-760-660-D400 Transition chamber, 700mm x 600mm 4080900 Removable segregation panel VTL-750X650 Transition chamber test lid assembly, 750mm x 650mm PCR-LIFT Transition chamber access cover lifting tool A Franklin Fueling Systems Brand franklinfueling.com 3760 Marsh Rd. Madison, WI 5378, USA Tel: + 608 838 8786 Fax: + 608 838 6433 Tel: USA & Canada + 800 5 9787 Tel: UK +44 (0)473 43300 Tel: Mex 00 800 738 760 Tel: FR +33 (0) 69 4 4 Tel: CH +86 0 8565 4566 FFS-0479 0-5