Agilent E8267C/E8257C/E8247C PSG

Similar documents
Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent E8247C/E8257C PSG CW and Analog Signal Generators Self Guided Demo. Product Note

Agilent E8267C PSG Vector Signal Generator

Agilent 8902A Measuring Receiver Product Note

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Agilent 87415A, 87400A Microwave Amplifiers

Agilent 83711B and 83712B Synthesized CW Generators

Agilent. E8267C PSG Vector Signal Generator E8257C PSG Analog Signal Generator E8247C PSG CW Signal Generator

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent EPM Series Power Meters

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent PNA Microwave Network Analyzers

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent PNA Series RF Network Analyzers

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent 8902A Measuring Receiver

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for GSM and EDGE Measurements

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent 83440B/C/D High-Speed Lightwave Converters

Product Note E5100A-2

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Agilent dc Electronic Loads Models N3300A-N3307A

Agilent 8761A/B Microwave Switches

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8360B/8360L Series Synthesized Swept Signal/CW Generators 10 MHz to 110 GHz

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Base Station Installation and Maintenance

6 Tips for Successful Logic Analyzer Probing

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

expanding the possibilities

Advanced Test Equipment Rentals ATEC (2832)

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Agilent 83554A/83555A/83556A mm-wave Source Modules* Data Sheet

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Agilent PNA Microwave Network Analyzers

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent 8510 Network Analyzer Product Note A

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent 4-Port PNA-L Network Analyzers

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Agilent Equalization Techniques and OFDM Troubleshooting for Wireless LANs

Agilent 8920A RF Communications Test Set Product Overview

Agilent 4285A Precision LCR Meter

Key Reference. Agilent Technologies E8663B Analog Signal Generator

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

Agilent 970-Series Handheld Multimeters Data Sheet

8 Hints for Better Spectrum Analysis. Application Note

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

PXA Configuration. Frequency range

Agilent Technologies 3000 Series Oscilloscopes

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Agilent PNA Microwave Network Analyzers

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Meet the new E4438C ESG vector signal generator...

9 Hints for Making Better Measurements Using RF Signal Generators. Application Note 1390

Agilent 8560 E-Series Spectrum Analyzers

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent E8247C/57C PSG CW and Analog Signal Generators

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Agilent E4428C ESG Analog Signal Generator

EMC Precompliance Systems and Accessories Catalog

Agilent Antenna and RCS Measurement Configurations Using PNA Microwave Network Analyzers. White Paper

Signal Generators for Anritsu RF and Microwave Handheld Instruments

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Frequency and Time Domain Representation of Sinusoidal Signals

Agilent 83430A Lightwave Digital Source Product Overview

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Advanced Test Equipment Rentals ATEC (2832) MG3690B. RF/Microwave Signal Generators, 0.1 Hz to 70 GHz/325 GHz

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent CSA Spectrum Analyzer

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

Transcription:

Agilent E8267C/E8257C/E8247C PSG Application Note Obtain flat-port power with Agilent s PSG user flatness correction or external leveling functions

E8247C PSG CW signal generator Agilent E8244A E8257C PSG analog signal generator Agilent E8254A E8267C PSG vector signal generator 2

Table of Contents Introduction Using External Leveling......................................................4 Leveling with a Millimeter-Wave Source Module.................................7 Creating and Applying User Flatness Correction.................................9 Creating a User Flatness Correction Array Using a MM-Wave Source Module........14 Performing the User Flatness Correction Manually..............................18 Saving the User Flatness Correction Data to the Memory Catalog..................19 The PSG synthesized signal generators provide extremely flat power at your test port for testing power sensitive devices such as amplifiers, mixers, diodes, or detectors. The user flatness correction feature of the PSGs compensates for attenuation and power variations created by components between the source and the test device. User flatness correction allows the digital adjustment of output amplitude for up to 1601 frequency points in any frequency or sweep mode (for example, start/stop, CW, power sweep, and more.). Using a power meter to calibrate the measurement system, a power level correction table is created for the frequencies where power level variations or loss occur. These frequencies may be defined in sequential linear steps or arbitrarily spaced. To allow different correction arrays for different tests setup or different frequency ranges, you may save individual user flatness correction tables to the signal generators memory catalog and recall them on demand. This application note illustrates how to utilize the user flatness correction feature by providing step-by-step instructions for several common measurement examples. 3

O LINE I E8254A 250 khz 40 GHz PSG -A Series Signal Generator FREQUENCY Print Local AMPLITUDE ON ON Return Hold Frequency Amplitude Incr Set GATE/PULSE TRIGGER INPUT INTERNAL PULSE GENERATOR VIDEO AM FM/ ΦM Pulse MENUS SYNC Sweep/ List Utility LF Out Save Recall Trigger Help 7 8 9 4 5 6 1 2 3 0. +/- Mod EXT 1 INPUT EXT 2 INPUT LP PUT ALC INPUT PUT REVERSE PWR! 1W MAX 0V DC Using External Leveling The PSG signal generator can be leveled externally by connecting an external sensor at the point where leveled output power is desired. The sensor detects changes in output power and returns a compensating voltage to the signal generator s ALC input. The ALC circuitry raises or lowers (levels) the output power based on the voltage received from the external sensor, ensuring constant power at the point of detection. Figure 3-1. External detector leveling with a directional coupler. Signal generator 40.000 000 000 000 GHZ 10.00 dbm MOD ALC output output Negative detector Directional coupler Leveled output Two types of external leveling are available on the PSG. You can use external leveling with a detector and coupler/power splitter setup, or a millimeter-wave source module. Leveling with detectors and couplers/splitters Figure 3-1 illustrates a typical external leveling setup. The power level feedback to the ALC circuitry is taken from the external negative detector, rather than the internal signal generator detector. The feedback voltage controls the ALC system, leveling the output power at the point of detection. To use detectors and couplers/ splitters for external leveling at an output frequency of 10 GHz and an amplitude of 0 dbm, follow the instructions in this section. Required equipment Agilent 8474E negative detector Agilent 87301D directional coupler cables and adapters, as required Connect the equipment Set up the equipment as shown in Figure 3-1. 4

Configure the signal generator 1. Press [Preset]. 2. Press [Frequency] > [10] > {GHz}. 3. Press [Amplitude] > [0] > {dbm}. 4. Press [ ]. 5. Press {Leveling Mode} > {External Detector}. This configuration deactivates the internal ALC detector and switches the ALC input path to the front panel ALC INPUT connector. The EXT indicator is activated in the AMPLITUDE area of the display. 6. Observe the coupling factor printed on the directional coupler at the detector port. Typically, this value is -10 to -20 db. Enter the positive db value of this coupling factor into the signal generator. For signal generators with Option 1E1, notice that the ATTN HOLD (attenuator hold) enunciator is displayed. During external leveling, the signal generator automatically uncouples the attenuator from the ALC system for all external leveling points. While in this mode, output amplitude adjustment is limited to 20 to +25 dbm, the adjustment range of the ALC circuitry. For more information, see External Leveling with Option 1E1 Signal Generators on page 6. 7. Press {More (1 of 2)} > Leveled output power is now available at {Ext Detector Coupling Factor} > [16] (or the the output of the directional coupler. positive representation of the value listed at the detector port of the directional coupler) > {db}. To determine the actual output amplitude at the point of detection, measure the voltage at the external detector output and refer to Figure 3-2. While operating in external leveling mode, the signal generator s displayed output amplitude is affected by the coupling factor value, resulting in a calculated approximation of the actual output amplitude. 5

Determining the leveled output power Figure 3-2 shows the input power versus output voltage characteristics for typical diode detectors from Agilent Technologies. Using this information, you can determine the leveled power at the diode detector input by measuring the external detector output voltage. The range of power adjustment is approximately 20 to +25 db External leveling with Option 1E1 signal generators Signal generators with Option 1E1 contain a step attenuator prior to the output connector. During external leveling, the signal generator automatically holds the present attenuator setting (to avoid power transients that may occur during attenuator switching) as the amplitude is changed. A balance must be maintained between the amount of attenuation and the optimum ALC level to achieve the required output amplitude. For optimum accuracy and minimum noise, the ALC level should be greater than 10 dbm. For example, leveling the CW output of a 30 db gain amplifier to a level of 10 dbm requires the output of the signal generator to be approximately 40 dbm when leveled. This is beyond the amplitude limits of the ALC modulator alone, resulting in an unleveled output. Inserting 45 db of attenuation results in an ALC level of +5 dbm, well within the range of the ALC modulator. Figure 3-2. Typical diode detector response at 25 C. Detector output voltage 10V 1.0V 100 mv 10 mv 1 mv Square Law Asymtote Linear Asymtote 0.1 mv 80 dbv 40 30 20 10 0 +10 +20 +30 Detector input power, dbm +20 dbv +10 dbv +6 dbv 0 dbv 10 dbv 20 dbv 30 dbv 40 dbv 50 dbv 60 dbv 66 dbv 70 dbv For modulated carriers, 55 db is the preferred attenuation choice, resulting in an ALC level of +15 dbm. This provides adequate dynamic range for AM or other functions that vary the output amplitude. To achieve the optimum ALC level at the signal generator output of 40 dbm for an unmodulated carrier, follow these steps: 1. Press [Set Atten] > [45] > {db}. 2. Press [Set ALC Level] > [5] > {dbm}. This sets the attenuator to 45 db and the ALC level to +5 dbm, resulting in an output amplitude of 40 dbm, as shown in the AMPLITUDE area of the display. To obtain flatness-corrected power, refer to Creating and Applying User Flatness Correction. 6

O LINE I E8254A 250 khz 40 GHz PSG -A Series Signal Generator FREQUENCY Print Local AMPLITUDE ON ON Return Hold Frequency Amplitude Incr Set GATE/PULSE TRIGGER INPUT INTERNAL PULSE GENERATOR VIDEO AM FM/ ΦM Pulse MENUS SYNC Sweep/ List Utility LF Out Save Recall Trigger Help 7 8 9 4 5 6 1 2 3 0. +/- E8349B Microwave Amplifier Mod EXT 1 INPUT EXT 2 INPUT LP PUT ALC INPUT PUT REVERSE PWR! 1W MAX 0V DC Leveling with a Millimeter-Wave Source Module Millimeter-wave source module leveling is similar to external detector leveling. The power level feedback signal to the ALC circuitry is taken from the millimeter-wave source module, rather than the internal signal generator detector. This feedback signal levels the output power at the mm-wave source module output through the signal generator s rear panel source module interface connector. Required equipment Agilent 83550 series millimeter-wave source module Agilent 8349B microwave amplifier (required for signal generators without Option 1EA) cables and adapters, as required Connect the equipment CAUTION To prevent damage to the signal generator, turn off the line power to the signal generator before connecting the source module interface cable to the rear panel source module interface connector. Figure 3-3. External Millimeterwave source module leveling for a signal generator without Option 1EA. Signal generator 40.000 000 000 000 GHZ 10.00 dbm MOD Source module 1. Turn off the signal generator s line power. 2. Connect the equipment as shown. Use the setup in Figure 3-3 for signal generators without Option 1EA. Use the setup in Figure 3-4 for Option 1EA signal generators. Source module interface output Adapter (If required) input Microwave amplifier output MM-wave source module input Leveled output 7

O LINE I E8254A 250 khz 40 GHz PSG -A Series Signal Generator FREQUENCY Print Local AMPLITUDE ON ON Return Hold Frequency Amplitude Incr Set GATE/PULSE TRIGGER INPUT INTERNAL PULSE GENERATOR VIDEO AM FM/ ΦM Pulse MENUS SYNC Sweep/ List Utility LF Out Save Recall Trigger Help 7 8 9 4 5 6 1 2 3 0. +/- Mod EXT 1 INPUT EXT 2 INPUT LP PUT ALC INPUT PUT REVERSE PWR! 1W MAX 0V DC Figure 3-4. External Millimeterwave source module leveling with an Option 1EA signal generator. Signal generator 40.000 000 000 000 GHZ 10.00 dbm MOD Source module output Adapter (If required) MM-wave source module Source module interface Leveled output Option 1EA signal generators can drive the output of millimeter-wave source modules to maximum specified power without a microwave amplifier. To ensure adequate amplitude at the mm-wave source module input when using Option IEA signal generators, maximum amplitude loss through the adapters and cables connected between the signal generator s output and the mm-wave source module s input which should be less than 1.5 db. Configure the signal generator 1. Turn on the signal generator s line power. Upon power-up, the signal generator automatically senses the mm-wave source module, switches the signal generator s leveling mode to external/source module, sets the mm-wave source module frequency and amplitude to the source module s preset values, and displays the output frequency and amplitude values available at the mm-wave source module output. The MMMOD indicator in the FREQUENCY area and the MM indicator in the AMPLITUDE area of the signal generator s display indicate that the mm-wave source module is active. Refer to the mm-wave source module specifications for the specific frequency and amplitude ranges. 2. If the OFF annunciator is displayed, Leveled power is now available at the output of press [ ]. the millimeter-wave source module. To obtain flatness-corrected power, refer to Creating and Applying User Flatness Correction. 8

Creating and Applying User Flatness Correction Using an Agilent E4416A/17A or E4418B/19B power meter, you can create user flatness correction arrays to correct output amplitude variances at user-defined frequencies. After completing a user flatness correction, the correction array data can be saved to the signal generator s memory catalog and recalled on demand. Follow the steps in the next sections to create and apply user flatness correction to the signal generator s output. Afterward, follow the steps in Recalling and Applying a User Flatness correction Array to recall a user flatness file from the memory catalog and apply it to the signal generator s output. Creating a user flatness correction array In this example, you will create a user flatness correction array. The flatness correction array contains ten frequency correction pairs (amplitude correction values for specified frequencies), from 1 to 10 GHz in 1-GHz intervals. An Agilent E4416A power meter (controlled by the signal generator via GPIB) and E4413A power sensor are used to measure the output amplitude at the specified correction frequencies and transfer the results to the signal generator. The signal generator reads the power level data from the power meter, calculates the correction values, and stores the correction pairs in the user flatness correction array. If you do not have the required Agilent power meter or GPIB interface, you can enter correction values manually. Required equipment Agilent E4416A power meter Agilent E4413A E Series CW power sensor GPIB interface cable adapters and cables, as required The equipment setup in Figure 3-5 assumes that if the setup has an external leveling configuration you have followed the necessary steps to correctly level the output. If you have questions about external leveling, refer to Using External Leveling. 9

O LINE I E8254A 250 khz 40 GHz PSG -A Series Signal Generator FREQUENCY AMPLITUDE 40.000 000 000 000 GHZ 10.00 dbm MOD ON ON Print Local Return Hold Frequency Amplitude Incr Set GATE/PULSE TRIGGER INPUT INTERNAL PULSE GENERATOR VIDEO MENUS AM Sweep/ List FM/ ΦM Pulse SYNC Utility LF Out Save Recall Trigger Help 7 8 9 4 5 6 1 2 3 0. +/- Mod EXT 1 INPUT EXT 2 INPUT LP PUT ALC INPUT PUT REVERSE PWR! 1W MAX 0V DC Figure 3-5. User Flatness Correction Equipment Setup. Signal generator GPIB ALC input Source module output Input port Cables and other devices Power meter Out Device under test In Flatness corrected output port Power sensor Configure the power meter 1. Zero and calibrate the power meter and power sensor. For operating information on your particular power meter/sensor, refer to their operating guides. If you are using a power meter/sensor combination other than the Agilent E4416A and E4413A, it may be necessary to: a. Enter the appropriate power sensor calibration factors into the power meter. b. Enable the power meter s cal factor array. Connect the equipment 1. Connect the equipment as shown in Figure 3-5. During the user flatness correction process, the power meter is slaved to the signal generator via GPIB. No other controllers are allowed on the GPIB interface. 10

Configure the signal generator 1. Press [Preset]. 2. Press [Amplitude] > {More (1 of 2)} > This opens the User Flatness table editor and {User Flatness} > {Configure Cal Array} > presets the correction array {More (1 of 2)} > {Preset List} > {Confirm Preset}. frequency/correction list. 3. Press {Configure Step Array}. This opens a menu for entering the user flatness step array data. 4. Press {Freq Start} > [1] > {GHz}. 5. Press {Freq Stop} > [10] > {GHz}. 6. Press {# of Points} > [10] > [Enter]. Steps 4, 5, and 6 enter the desired flatnesscorrected frequencies into the step array. 7. Press [Return] > {Load Cal Array From This populates the user flatness correction Step Array} > {Confirm Load From Step Sweep}. array with the frequency settings defined in the step array. 8. Press [Amplitude] > [0] > {dbm}. 9. Press [ ]. This activates the output and the ON annunciator is displayed on the signal generator. If using an Agilent E4417A/18A/19A power meter, follow these steps to configure the signal generator to perform the user flatness correction: 10. Press [Amplitude] > {More (1 of 2)} > This allows you to choose another power {User Flatness} > {More (1 of 2)} > meter model. {Power Meter and E4417A, E4418A, or E4419A}. 11. Press [Meter Address] > [enter the power This configures the signal generator to interface meter s GPIB address] > [Enter]. with a power meter at the GPIB address entered. 12. Press [Meter Channel A B] to select the power meter s active channel. 13. Press [Meter Timeout] to adjust the length of time before the instrument generates a timeout error while unsuccessfully attempting to communicate with the power meter. Perform the user flatness correction If you are not using an Agilent E4416A/17A/18A/19A power meter, or if you do not have GPIB interface capability, you can perform the user flatness correction manually. For instructions, see Performing the User Flatness Correction Manually. 1. Press {More (1 of 2)} > {User Flatness} > This performs the user flatness correction. The {Do Cal}. signal generator enters the user flatness correction routine and a progress bar is shown on the display. 2. When prompted, press {Done}. This loads the amplitude correction values into the user flatness correction array. If desired, press {Configure Cal Array}. This opens the user flatness correction array, where you can view the stored amplitude correction values. The user flatness correction array title displays User Flatness: (UNSTORED) indicating that the current user flatness correction array data has not been saved to the memory catalog. 11

Performing the user flatness correction manually If you are not using an Agilent E4416A/17A/18A/19A power meter or if you do not have GPIB interface capability, you can perform the user flatness correction manually. Complete the steps in this section and then continue with the User Flatness Correction tutorial. 1. Press {More (1 of 2)} > {User Flatness} > This opens the user flatness table editor and {Configure Cal Array}. places the cursor over the frequency value (1 GHz) for row 1. The output changes to the frequency value of the table row containing the cursor and 1.000 000 000 00 is displayed the AMPLITUDE area of the display. 2. Observe and record the measured value from the power meter. 3. Subtract the measured value from 0 dbm. 4. Move the table cursor over the correction value in row 1. 5. Press {Edit Item} > [enter the difference The signal generator adjusts the output value from Step 3] > {db}. amplitude based on the correction value entered. 6. Repeat Steps 2 through 5 until the power meter reads 0 dbm. 7. Use the down arrow key to place the cursor over the frequency value for the next row. The output changes to the frequency value of the table row containing the cursor, as shown in the AMPLITUDE area of the display. 8. Repeat Steps 2 through 7 for every entry in the User Flatness table. Save the user flatness correction data to the memory catalog This process allows you to save the user flatness correction data as a file in the signal generator s memory catalog. With several user flatness correction files saved to the memory catalog, specific files can be recalled, loaded into the correction array, and applied to the output to satisfy specific output flatness requirements. 1. Press {Load/Store}. 2. Press {Store to File}. 3. Enter the file name FLATCAL1 using the alphanumeric soft keys and the numeric keypad. 4. Press {Enter}. The user flatness correction array file FLATCAL1 is now stored in the memory catalog as a UFLT file. Applying a user flatness correction arrays 1. Press [Return] > [Return] > {Flatness Off On}. This applies the user flatness correction array to the output. The UF indicator is activated in the AMPLITUDE section of the signal generator s display and the frequency correction data contained in the correction array is applied to the output amplitude. 12

Recalling and applying a user flatness correction array Before performing the steps in this section, complete Creating a User Flatness Correction Array. 1. Press [Preset]. 2. Press [Amplitude] > {More (1 of 2)} > {User Flatness} > {Configure Cal Array} > {More (1 of 2)} > {Preset List} > {Confirm Preset}. 3. Press {More (2 of 2)} > {Load/Store}. 4. Ensure that the file FLATCAL1 is highlighted. 5. Press {Load From Selected File} > This populates the user flatness correction array {Confirm Load From File}. with the data contained in the file FLATCAL1. The user flatness correction array title displays User Flatness: FLATCAL1. 6. Press [Return] > {Flatness Off On}. This applies the user flatness correction data contained in FLATCAL1. Returning the signal generator to GPIB listener mode During the user flatness correction process, the power meter is slaved to the signal generator via GPIB, and no other connections are allowed on the GPIB interface. The signal generator operates in GPIB talker mode, as a device controller for the power meter. In this operating mode, it cannot receive SCPI commands via GPIB. 1. Save your instrument state to the For instructions, see Saving an Instrument State instrument state register. in example 6 on page 20. 2. Press [GPIB Listener Mode]. This presets the signal generator and returns it to GPIB listener mode. The signal generator can now receive remote commands executed by a remote controller connected to the GPIB interface. 3. Recall your instrument state from the instrument state register. For instructions, see Recalling an Instrument State in example 6 on page 20. CAUTION If the signal generator is interfaced to a remote controller after performing the user flatness correction, its GPIB controller mode must be changed from GPIB talker to GPIB listener. This is accomplished by presetting the signal generator. If an carrier has been previously configured, you must save the present instrument state before returning the signal generator to GPIB listener mode. 13

Array Using a MM-Wave Source Module In this example, a user flatness correction array is created to provide flatness-corrected power at the output of an Agilent 83554A millimeterwave source module driven by an Agilent E8247C signal generator. The flatness correction array contains 28 frequency correction pairs (amplitude correction values for specified frequencies), from 26.5 to 40 GHz in 500 MHz intervals. This will result in 28 evenly spaced flatness corrected frequencies between 26.5 GHz and 40 GHz at the output of the Agilent 83554A millimeterwave source module. An Agilent E4416A power meter (controlled by the signal generator via GPIB) and R8486A power sensor are used to measure the output amplitude of the millimeter-wave source module at the specified correction frequencies and transfer the results to the signal generator. The signal generator reads the power level data from the power meter, calculates the correction values, and stores the correction pairs in the user flatness correction array. If you do not have the required Agilent power meter or GPIB interface, you can enter correction values manually. Required equipment Agilent 83554A mm-wave source module Agilent E4416A power meter Agilent R8486A power sensor Agilent 8349B microwave amplifier (required for signal generators without option 1EA) GPIB interface cable adapters and cables as required The equipment setups in Figure 3-6 and Figure 3-7 assume that, if the setups have an external leveling configuration, the steps necessary to correctly level the output have been followed. If you have questions about external leveling, refer to Leveling with a Millimeter- Wave Source Module in example 6 on page 19 Configure the power meter 1. Zero and calibrate the power meter and power sensor. 2. Enter the appropriate power sensor calibration factors into the power meter. 3. Enable the power meter s cal factor array. For operating information on your particular power meter/sensor, refer to their operating guides. Connect the equipment CAUTION To prevent damage to the signal generator, turn off the line power to the signal generator before connecting the source module interface cable to the rear panel source module interface connector. 1. Turn off the line power to the signal generator. 2. Connect the equipment. For standard signal generators, use the setup in Figure 3-6. For Option 1EA signal generators, use the setup in Figure 3-7. During the user flatness correction process, the power meter is slaved to the signal generator via GPIB. No other connections are allowed on the GPIB interface. When using Option 1EA signal generators, to ensure adequate amplitude at the mm-wave source module input, maximum amplitude loss through the adapters and cables connected between the signal generator s output and the mm-wave source module s input should be less than 1.5 db. 14

O O LINE LINE I I E8254A 250 khz 40 GHz PSG -A Series Signal Generator FREQUENCY Print Local E8254A 250 khz 40 GHz PSG -A Series Signal Generator FREQUENCY Print Local AMPLITUDE AMPLITUDE ON ON ON ON Return Return Hold Hold Frequency Amplitude Frequency Amplitude Incr Set GATE/PULSE TRIGGER INPUT Incr Set GATE/PULSE TRIGGER INPUT INTERNAL PULSE GENERATOR VIDEO MENUS AM Sweep/ List FM/ ΦM Pulse SYNC Utility LF Out Save Recall Trigger Help 7 8 9 4 5 6 1 2 3 0. +/- E8349B Microwave Amplifier INTERNAL PULSE GENERATOR VIDEO SYNC Mod MENUS AM Sweep/ List FM/ ΦM Pulse Utility LF Out Save Recall Trigger Help 7 8 9 4 5 6 1 2 3 0. +/- Mod EXT 1 INPUT EXT 2 INPUT LP PUT ALC INPUT PUT REVERSE PWR! 1W MAX 0V DC EXT 1 INPUT EXT 2 INPUT LP PUT ALC INPUT PUT REVERSE PWR! 1W MAX 0V DC Figure 3-6. User flatness with mm-wave source module for a signal generator without Option 1EA. Signal generator 40.000 000 000 000 GHZ 10.00 dbm MOD GPIB Power meter Source module output input Microwave amplifier output Power sensor Source module interface MM-wave source module Input Leveled output Figure 3-7. User flatness with mm-wave source module and option 1EA signal generator. Signal generator 40.000 000 000 000 GHZ 10.00 dbm MOD GPIB Power meter Source module output Power sensor Source module interface MM-wave source module input Leveled output 15

Configure the signal generator 1. Turn on the signal generator s line power. Upon power-up, the signal generator automatically: senses the mm-wave source module, switches the signal generator s leveling mode to external/source module, sets the mm-wave source module frequency and amplitude to the source module s preset values, and displays the output frequency and amplitude values available at the mm-wave source module output. The MMMOD indicator in the FREQUENCY area and the MM indicator in the AMPLITUDE area of the signal generator s display indicate that the mm-wave source module is active. Refer to the mm-wave source module specifications for the specific frequency and amplitude ranges. 2. Press [Amplitude] > {More (1 of 2)} > This opens the User Flatness table editor and {User Flatness} > {Configure Cal Array} > resets the correction array frequency/ {More (1 of 2)} > {Preset List} > {Confirm Preset}. correction list. 3. Press {Configure Step Array}. This opens a menu for entering the user flatness step array data. 4. Press {Freq Start} > [26.5] > {GHz}. 5. Press {Freq Stop} > [40] > {GHz}. 6. Press {# of Points} > [28] > {Enter}. This enters the desired flatness-corrected frequencies (26.5 GHz to 40 GHz in 500 MHz intervals) into the step array. 7. Press [Return] > {Load Cal Array From This populates the user flatness correction array Step Array} > {Confirm Load From Step Sweep}. with the frequency settings defined in the step array. 8. Press [Amplitude] > [0] > {dbm}. 9. Press [ ]. This activates the output and the ON enunciator is displayed on the signal generator. If using a power meter other than an E4416A, follow these steps to configure the signal generator to perform the user flatness correction. 10. Press [Amplitude] > {More (1 of 2)} > This allows you to choose another {User Flatness} > {More (1 of 2)} > {Power Meter power meter model. and E4417A, E4418A, or E4419A}. 11. Press {Meter Address} > [enter the power This configures the signal generator to interface meter s GPIB address] > {Enter}. with a power meter at the GPIB address entered. 12. Press {Meter Channel A B} to select the power For E4419B and E4417B meter s active channel. 13. Press [Meter Timeout] to adjust the length of For E4419B and E4417B time before the instrument generates a timeout error while unsuccessfully attempting to communicate with the power meter. 16

Perform the user flatness correction If you are not using an Agilent E4416A/17A/18A/19A power meter, or if you do not have GPIB interface capability, you can perform the User Flatness Correction manually. For instructions, see Performing the User Flatness Correction Manually. 1. Press {More (1 of 2)} > {User Flatness} > This performs the user flatness correction. The {Do Cal}. signal generator enters the user flatness correction routine and a progress bar is shown on the display. 2. When prompted, press {Done}. This loads the amplitude correction values into the user flatness correction array. If desired, press {Configure Cal Array}. This opens the user flatness correction array, where you can view the list of defined frequencies and their calculated amplitude correction values. The user flatness correction array title displays User Flatness: (UNSTORED) indicating that the current user flatness correction array data has not been saved to the memory catalog. 17

User Flatness Correction Manually If you are not using an Agilent E4416A/17A/18A/19A power meter or if you do not have GPIB interface capability, you can perform the User Flatness Correction manually. Complete the steps in this section and then continue with the User Flatness Correction tutorial. 1. Press [More (1 of 2)] > {User Flatness} > This opens the User Flatness table editor and {Configure Cal Array}. places the cursor over the frequency value (26.5 GHz) for row 1. The output changes to the frequency value of the table row containing the cursor and 26.500 000 000 00 is displayed the AMPLITUDE area of the display. 2. Observe and record the measured value from the power meter. 3. Subtract the measured value from 0 dbm. 4. Move the table cursor over the correction value in row 1. 5. Press {Edit Item} > [enter the difference value The signal generator adjusts the output from Step 3] > {db}. amplitude based on the correction value entered. 6. Repeat Steps 2 through 5 until the power meter reads 0 dbm. 7. Use the down arrow key to place the cursor The output changes to the frequency value over the frequency value for the next row. of the table row containing the cursor, as shown in the AMPLITUDE area of the display. 8. Repeat Steps 2 through 7 for every entry in the User Flatness table. 18

Save the User Flatness Correction Data to the Memory Catalog This process allows you to save the user flatness correction data as a file in the signal generator s memory catalog. With several user flatness correction files saved to the memory catalog, specific files can be recalled, loaded into the correction array, and applied to the output to satisfy various output flatness requirements. 1. Press {Load/Store}. 2. Press {Store to File}. 3. Enter the file name FLATCAL2 using the alphanumeric soft keys and the numeric keypad. 4. Press {Enter}. The user flatness correction array file FLATCAL2 is now stored in the memory catalog as a UFLT file. Applying the user flatness correction array 1. Press [Return] > [Return] > {Flatness Off On}. This applies the user flatness correction array to the output. The UF indicator is activated in the AMPLITUDE section of the signal generator s display and the frequency correction data contained in the correction array is applied to the output amplitude of the mm-wave source module. Recalling and applying a user flatness correction array Before performing the steps in this section, complete the section Creating a User Flatness Correction Array Using a MM-Wave Source Module. 1. Press [Preset]. 2. Press [Amplitude] > {More (1 of 2)} > {User Flatness} > {Configure Cal Array} > {More (1 of 2)} > {Preset List} > {Confirm Preset}. 3. Press [More (2 of 2)] > {Load/Store}. 4. Ensure that the file FLATCAL2 is highlighted. 5. Press {Load From Selected File} > This populates the user flatness correction array {Confirm Load From File}. with the data contained in the file FLATCAL2. The user flatness correction array title displays User Flatness: FLATCAL2. 6. Press [Return] > {Flatness Off On}. This activates flatness correction using the data contained in the file FLATCAL2. 19

To find out more visit: www.agilent.com/find/psg Related Agilent literature Agilent PSG Signal Generators, Brochure, Literature number 5988-7538EN Agilent E8267C PSG Vector Signal Generator, Data Sheet, Literature number 5988-6632EN Agilent E8247C/E8257C PSG Analog/CW Signal Generator, Data Sheet, Literature number 5988-7454EN Agilent PSG Vector Signal Generator Self Guided Demo, Literature number 5988-8087EN Agilent E8247C/E8257C PSG Analog/CW Self Guided Demo, Literature number 5988-2414EN Agilent E8267C PSG Vector Configuration Guide, Literature number 5988-7541EN Agilent E8247C/E8257C PSG Analog/CW Configuration Guide, Literature number 5988-7879EN Agilent PSG Series Product Note: Millimeter Head, Literature number 5988-2567EN Agilent PSG Two-tone and Multi-tone, Application Note 1410, Literature number: 5988-7689EN www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. By internet, phone, or fax, get assistance with all your test & measurement needs Phone or Fax United States: (tel) 800 452 4844 Canada: (tel) 877 894 4414 (fax) 905 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com Online Assistance: www.agilent.com/find/assist Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2001, 2003 Printed in USA, February 4, 2003 5988-2410EN