MIT510, MIT520 and MIT1020

Similar documents
MIT510/2, MIT520/2 and MIT1020/2

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

MIT515, MIT525, MIT1025

Advanced Test Equipment Rentals ATEC (2832)

BM25 Automated 5-kV Insulation Tester

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400/2 CAT IV Insulation testers

MIT400/2 CAT IV Insulation testers

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

AEMC Megohmmeters. AEMC Flexible Current Probe

BMM80 Premium Insulation Multimeters

TTR 100 Single-Phase Handheld TTR

ODEN AT Primary Current Injection Test System

Insulation Testers and Earth Ground Testers

MIT415 Insulation tester

MIT480/2 Insulation testers

Insulation resistance testing. A complete solution for every person.

Insulation resistance testing. A complete solution for every application.

n Single- and three-phase transformer n Lightweight, handheld n Battery powered, line rechargeable n Tests turns ratio, phase displacement,

Insulation resistance testing. A complete solution for every application

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

INSULATION TESTER SERIES

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis

Digital insulation tester

Advanced Test Equipment Rentals ATEC (2832)

Insulation resistance testing. A complete solution for every application.

DET4 Series. 4-Terminal Earth/Ground Resistance and Soil Resistivity Testers. DET4 Series Earth/Ground Resistance & Soil Resistivity Testers

MIT520/2 5kV Digital Insulation Tester USER MANUAL

Laboratory oil testers

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

THE ELECTROM itig II MOTOR TESTER AND WINDING ANALYZER

VF3 AC Voltage detector. User Guide Guide de l utilisateur Bedienungsanleitung Guía del usuario

MFT1735 User guide addendum

Advanced Test Equipment Rentals ATEC (2832)

FRAX 101 Sweep Frequency Response Analyzer

S1-1054/2 10kV Digital Insulation Tester USER MANUAL

S1-552/2 5kV Digital Insulation Tester USER MANUAL

Award winning product

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

FRAX Series Sweep Frequency Response Analyzers

The NEW itig II Winding and Motor Analyzer A revolution in automated, safe, and comprehensive high and low voltage tests all in a lightweight

ANNEXURE 1 LIST OF EQUIPMENTS LOT 1

Fully automated three phase 250V Transformer Turns Ratio Meter

True Three-Phase Transformer Turns Ratio Tester TRT40A

MIT400 Series Insulation and continuity testers

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

International distributors

TRM-203/403 transformer resistance meters

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

GROUND RESISTANCE TEST EQUIPMENT

METRISO 5000 D-PI Digital High-Voltage Insulation Tester

TRM-203/TRM-403. transformer resistance meters. Vanguard Instruments Company, Inc.

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

MD-5060 DIGITAL MEGOHMMETER

Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter

Electrical Test & Measurement Equipment

USER'S MANUAL DMR-6700

TRAX Transformer and Substation Test System

Insulation Testing. Distributor Training Program

True Three-Phase Transformer Turns Ratio Tester TRT4x

Technical Data Sheet. Zeta 20

G SAFETY WARNINGS. LT300 High current loop tester. User guide

TTR2796. Fully Automated Three Phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS APPLICATIONS

Three-Phase Transformer Turns Ratio Tester TRT03B

True Three-Phase Transformer Turns Ratio Tester TRT30A

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Analog Digital Multimeter with Insulation Resistance Measurement

4-range High voltage insulation resistance tester KEW 3126

Winding Ohmmeter RMO-TW

MEGOHMMETER ENGLISH. User Manual

True Three-Phase Transformer Turns Ratio Tester TRT4x

Safety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software

NEW PRODUCT LAUNCH SALES GUIDE MIT480/2

MW3105 DIGITAL CLAMP MULTIMETER

TORKEL 900-series Battery Load Unit

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

MIT400 Series Insulation and continuity testers

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Advanced Test Equipment Rentals ATEC (2832)

APPA 300 Series. The Most User-Friendly High Performance Multimeter

True Three-Phase Transformer Turns Ratio Tester TRT63B

Measure voltage without test leads. Product Highlights

GAMMA 20 DIGITAL MULTIMETER

True Three-Phase Transformer Turns Ratio Tester TRT30A

Insulation Resistance Testing Guide

SVERKER 900 Relay and Substation Test System

Three-Phase Transformer Turns Ratio Tester TRT03C

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Megohmmeter Model 1060

Fluke 1660 Series Multifunction Installation Testers

MEGGER BMM2000 Series Insulation Multimeters User Guide

Transcription:

MIT510, MIT520 and MIT1020 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510 and MIT520) and 35 TΩ (MIT1020) Automatic insulation resistance tests Automatic dielectric absorption ratio, polarization index, step voltage, and dielectric discharge tests (MIT520 and MIT1020) RS232 or USB download of results (MIT520 and MIT1020) Ingress protection to IP65 3 ma short circuit current DESCRIPTION The new MIT510 and 520 5kV and MIT1020 10kV insulation resistance testers are all designed specifically to assist the user with the testing and maintenance of high voltage equipment. The instruments are designed in a landscape style which is more familiar and user friendly. The measurement ranges have been increased significantly for all three units. The MIT510 and MIT520 measurement range has been expanded to 15 TΩ, replacing the ambiguous infinity reading with an actual number that can be used for predictive/preventive trending on the highest quality insulation. The MIT510 has the facility to set the test voltage in steps from 250 V to 5000 V and the MIT520 has the ability to set the test voltage from 50 V to the maximum output voltage. The MIT1020 offers an increased measurement range to 35 TΩ in order to provide trending values for the best of insulating materials used on the higher capitalized equipment. The model features an expanded test voltage range from 50 V to 10 kv, in 10 V increments to 1 kv and 25 V increments above. All three instruments have a large, easy-to-read backlit LCD making them equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time is displayed constantly, removing the need for separate timers. The MIT520 and MIT1020 allow up to 3 timed measurement positions to be set, which simplifies DAR testing. A built-in integral timer starts automatically at the beginning of a test, and displays in minutes and seconds. At the end of any test, capacitive loads are automatically discharged and the decaying voltage displayed. The timer enables the performance of an automatic IR test with the MIT510, while the MIT520 and MIT1020 add the capability of preprogrammed DAR, PI, SV and DD. The MIT520 and MIT1020 include a selectable breakdown or burn mode and an alarm mode, which allows the operator to preset a specific resistance level. The unit will beep until the limit is exceeded. The controls of the instruments are clear and unambiguous, and a quick start guide is included in the lid, eliminating the need to carry manuals to site locations. Redundant safety features make the instruments fully amenable to safe operation in the more demanding high voltage environment. Instrument design is in conformance with EN61010 for arc-flash protection. If the instrument is accidentally connected to a live test item, external voltage will be automatically displayed and testing inhibited above 50 V (80 V on MIT1020). At the conclusion of a test, dangerous static voltage on the test item is automatically discharged and monitored on the display. All three models are fitted with a guard terminal to enhance accuracy. The guard test lead is included as standard with each instrument. APPLICATIONS All three models are designed for testing the insulation of high-voltage electric equipment. Their wide voltage range also allows applications for low-voltage equipment. Generators, motors, transformers, cables and switchgear all require effective maintenance. The test techniques on the instruments provide valuable diagnostic information.

All three instruments test the insulation resistance of: High-voltage power cables and high-voltage buses Large motor/generator windings Line and substation transformers The MIT520 and MIT1020 also perform spot tests, stepvoltage tests, dielectric discharge tests and dielectric absorption tests for the following applications: Acceptance testing at installation to check conformance to specifications. Routine preventive/predictive maintenance testing after installation. Quality assurance testing as part of the manufacturing process. Diagnostic testing to isolate faulty components for repair. With its higher voltage testing capability, the MIT1020 is the perfect every day work tool for manufacturers, users and maintainers of rotating machinery. Designed in accordance with the requirements of IEEE43:2000 the MIT1020 is ideal for measuring the insulation resistance of armature and field windings in rotating machines rated 1hp (750 W) or greater. The standard applies to synchronous, induction and dc machines as well as synchronous condensers. FEATURES AND BENEFITS Improved operating flexility provides the user with the choice of using these instruments via line or battery operation. Line operation also affords enhanced charging capabilities for high-capacitance test samples. High measurement range enables installation testing and long-term trending of higher value apparatus. 3 ma short circuit current allows for faster charging and testing of large capacitive and inductive loads. Results storage and downloading enables state-of-the-art record keeping free of transposition errors. Five industry-standard tests can be performed automatically, freeing operator from time-consuming manual operations. Backlit display enables ease of testing in poorly lit areas. Rugged, lightweight polypropylene case and IP65 rating make all of the instruments adaptable for all field conditions. A variety of measurements including applied test voltage, leakage current and capacitance, affords enhanced capabilities to diagnose insulation condition and problems. Redundant safety features includes automatic discharge of test item, test inhibition in presence of external voltage, and design to EN61010. The MIT1020 incorporates the ability to apply test voltage up to 10 kv, making it fully conformable to the requirements of IEEE43:2000. A quick start guide is included in the lid, eliminating the need to carry bulky manuals to site locations. For greater ease of use and downloading, an RS232 or USB interface is available (MIT520 and MIT1020 only). Alarm limit mode (MIT520 and MIT1020 only) allows for faster testing and less ambiguous result interpretation. The MIT1020 in use at an industrial complex substation Delta wye transformer being testing with a MIT520

These unique features improve insulation testing efficiency and effectiveness Extra data storage and download capability Run more tests and save more test data. Download results using either an RS232 or USB style connection (MIT520 and MIT1020 only). Line or battery operation The operating flexibility you need when site conditions are unknown or long term testing is required. Multiple built-in safety features Designed to meet the most stringent operator safety requirements, including EN61010. Includes live voltage warning, safety lockout over 50 V on 5-kV testers and 80 V on 10-kV testers, and automatic energy discharge. Improved enclosure It s virtually indestructible, yet ergonomic and lightweight. It features an oversized rubber handle and removable lid for effective use in tight places. A lid mounted lead storage bag is also included. Easier operation Use a Quick Start guide conveniently located in the lid, always there for easy reference.

SPECIFICATIONS Test Voltage MIT510: 250 V, 500 V, 1000 V, 2500 V, 5000 V MIT520: 50 V to 1 kv in 10 V steps, 1 kv to 5 kv in 25 V steps MIT1020: 50 V to 1 kv in 10 V steps, 1 kv to 10 kv in 25 V steps Insulation Resistance Range Digital display: MIT510/MIT520: 10 kω to 15 TΩ MIT1020: 10 kω to 35 TΩ Analog display: MIT510/MIT520/MIT1020: 100 kω to 1 TΩ Accuracy (23º C) ±5% to 1 TΩ ±20% to 10 TΩ (MIT520) ±20% to 20 TΩ (MIT1020) Voltage Output Accuracy (0ºC to 30ºC) 0 to +4% ±1 V of nominal test voltage at 100 MΩ load ±25 V for test voltages less than 500 V Short Circuit/Charge Current 3 ma Current Measurement Range: ±0.01 na to ±5 ma Accuracy (23ºC): ±5% ±0.2 na at all voltages Capacitance Measurement Range: 10 nf to 50 µf (for voltages > 500 V) Accuracy (23ºC): ±5% ±5 nf kv 6 5 4 3 2 1 0 5kV Voltage Characteristic 0 1 2 3 4 5 6 7 8 9 10 M Ohms 5kV 2.5kV 1kV 500V 250V Capacitor Charge Time: 5 seconds per µf at 3 ma Discharge Time: 5 seconds per µf to discharge from: MIT510/MIT520: 5000 V to 50 V MIT1020: 10,000 to 50 V Display Analog/digital 3 digits Timer Range Count up to 99 minutes and 59 seconds from start of test Memory Capacity (MIT520 and MIT1020) 32 kb Industry-Standard Tests MIT510: Auto IR MIT520: Auto IR, PI, DAR, SV, and DD MIT1020: Auto IR, PI, DAR, SV, and DD Interference Rejection 2 ma rms at 200 V and above Guard Terminal 2% error guarding 500 kω leakage with 100 mω load Voltage Input Range 95 to 240 V, ±10% rms 50/60 Hz and dc Battery Life 6 hours continuous testing at 5 kv 4 hours continuous testing at 10 kv Safety Meets the requirements of EN61010-1: 2001 CAT 111 600 V EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas Ingress Protection IP65 (lid closed) Temperature Range Operating: 14ºF to 122ºF (-10ºC to +50ºC) Storage: -13ºF to +149ºF (-25ºC to +65ºC) Humidity Range 90% RH @ 104ºF (40ºC) Dimensions 12 in. x 7.6 in. x 14.2 in. (305 mm x 194 mm x 360 mm) Weight 15 lb. (6.75 kg) Test Voltage Output Characteristics Over Insulation Resistance Range

Product comparison guide. A look at each instrument s features. MIT510 MIT520 MIT1020 Display Analog/Digital Power Supply Mains power Rechargeable 10.0 kv 5.0 kv 2.5 kv Test Voltage 1.0 kv 500 V 250 V 10 V steps 50 V to 1 kv, 25 V steps 1 kv to max test voltage Max reading 15 TΩ 15 TΩ 35 TΩ Min reading 10 kω 10 kω 10 kω Measurements Voltage Capacitance and time constant Leakage current Auto IR Polarization index Test Types Step voltage Dielectric discharge Dielectric absorption ratio Timer control Timer display 3mA test currents Other Features USB output RS232 output Free calibration certificate IP65 rating Alarm limit mode What is the IEEE Standard 43-2000? In March 2000, the IEEE-SA Standards Board approved a revision of IEEE Std 43-1974 by the Electric Machinery Committee of the IEEE Power Engineering Society. This revision is IEEE Std 43-2000, the IEEE Recommended Practice for Testing Insulation Resistance of Rotating Machinery. Following is a brief summary of the highlights of IEEE Standard 43-2000: Test voltages up to 10 kv are recommended for windings rated greater than 12 kv. Both the insulation resistance and the polarization index test are recommended. Test results should be compared to historical values to identify changes. In lieu of historical records, minimum acceptable values (based on the type of equipment) for both tests are indicated. Depending on the machine rating, the readings for one or both tests should exceed the minimum acceptable values. If the readings are below the minimum acceptable values, the winding is not recommended for an overvoltage test or for operation.

MIT520/MIT1020 DISPLAY EXAMPLE 1 15 14 13 12 11 2 3 10 4 4 5 9 6 7 8 1. Voltage at terminals Displays amount of voltage present at the terminal. 2. Battery level Indicates the level of battery operation available. 3. Breakdown indicator Indicates that breakdown mode is in operation 4. High-voltage indicator Indicates the presence of high voltage during operation. 5. Digital display Displays the reading during a test. 6. Dielectric absorption ratio (DAR) 7. Polarization index (PI) 8. Time constant 6 through 8 Displays the ratio value or the resistance measured at the indicated time. 9. Capacitance display Indicates the capacitance of the test sample. 10. Analog display Unique, patented analog display shows resistance with real-time pointer movement. 11. Timer Displays the elapsed time of test. Displayed constantly, eliminating the need for a separate timer. 12. Data recording Indicates if data is being recorded during the test. 13. Alarm Indicates that alarm has been set. 14. Burn indicator Indicates that burn mode is in operation. 15. Test modes Shows which pre-programmed test is being run. ORDERING INFORMATION Item [Qty] Cat. No. 5-kV Insulation Resistance Tester MIT510 5-kV Insulation Resistance Tester MIT520 10-kV Insulation Resistance Tester MIT1020 Included Accessories 10 ft (3 m) lead set [3] 210968 RS232 cable (MIT520 and MIT1020) EV25955-025 USB cable (MIT520 and MIT1020) 25970-041 Item Cat. No. Line cord 17032 Pouch 6320-244 MIT510 User guide, CD version 6172-929 MIT520/MIT1020 User guide, CD version 6172-960 Optional Accessories 10 ft (3 m) lead set with straight jaw clamps EV6220-797 50 ft (15 m) lead set EV6121-452 UK Archcliffe Road, Dover CT17 9EN England T (0) 1 304 502101 F (0) 1 304 207342 UNITED STATES 4271 Bronze Way Dallas, TX 75237-1019 USA T 1 800 723 2861 T 1 214 333 3201 F 1 214 331 7399 OTHER TECHNICAL SALES OFFICES Norristown USA, Toronto CANADA, Mumbai INDIA, Trappes FRANCE, Sydney AUSTRALIA, Madrid SPAIN and The Kingdom of BAHRAIN. ISO STATEMENT Registered to ISO 9001:2000 Reg no. Q 09250 Registered to ISO 14001 Reg no. EMS 61597 MIT510_520_1020_DS_en_V03 www.megger.com Megger is a registered trademark