Series P. Applications

Similar documents
LED Driver Constant voltage

LED Driver Constant voltage

3 - Protection components Circuit-breakers

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

Protection relays and transformers

K Factor Power Transformers

DATA SHEET Selectable AC transducer TAS-311DG

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Theta 20A / 20V. Technical Data Sheet. Special Features

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

LED control gear Linear / area fixed output

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

LED control gear Compact fixed output. Uconverter LCI 20 W 350/500/700 ma TEC SR TEC series

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Installation / Monitoring Technique

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

LED Driver Linear / area fixed output

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

LED Driver Compact fixed output

SPECIFICATION. Online UPS 3000VA

Theta Hz. Technical Data Sheet. Special Features

Reactors for filtering

LED Driver Compact fixed output

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

NS..S contactor relays - with spring terminals AC operated

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT

N. TEST TEST DESCRIPTION

LED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Accessories. Accessories

MINI-PS AC/2X15DC/1

RISH Ducer E13 3 channel transducer for AC current and voltage

LED Driver Constant voltage

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

MINI-PS AC/24DC/1.3

02/11/2015

Measuring current transformers of the W, W series

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

LED Driver Compact fixed output. Udriver LC 15/20/25W 350/500/700/600mA fixc C SNC ESSENCE series

Bridgeport Magnetics Design Guide

PSR-SCP- 24DC/ESD/5X1/1X2/300

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

LED Driver Constant voltage. Udriver LCU 60W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED Driver Constant voltage

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

DS10000ULFS-10V/10kA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

QUINT-PS/ 3AC/24DC/10

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

N. TEST TEST DESCRIPTION

Capacitor Switching Contactors

Technical features table for miniature circuit-breakers SH 200 Series

LED Driver Compact fixed output

W DATA SHEET Current Transformer 40 x 10, A

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Orbital GFI Inverter Series

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

LED Driver Compact dimming outdoor

Smart Power Relay E I...

Automatic capacitor banks with detuned filters

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

LED Driver Compact fixed output

Electronic Circuit Breaker ESS20-0..

Automatic capacitor banks with detuned filters

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

LED Driver Linear / area fixed output

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

LED Driver Compact dimming

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Power Meter Series PM3200 Functions and characteristics

Protection components

CP-T range Product group picture

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Transcription:

Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any selected combination of input and output voltages. Applications Control Transformer: Transformer able to supply a high instantaneous power without voltage drop at the output. Very suitable for interlocking contactors, relays and electro valves, as well as adaptation of the mains voltage to the necessary supply voltage of the loads. Isolation Transformer: Transformer with secondary voltage > 50 V, with double or reinforced isolation between primary and secondary. Its construction provides an excellent degree of attenuation of electrical distortions. Recommended for: - Electronic equipment, PLC s and automation systems. - Auxiliary elements in electrical panels. - Linear and switching power supplies. Eliminates the risk of human accidents in case of unipolar contacts. Safety Transformer: Transformer with secondary voltage < 50 V, with double or reinforced isolation between primary and secondary. Eliminates any risk of human accidents in case of unipolar or bipolar contacts. Standards IEC / EN / UNE-EN 61558-2-2... Control transformer IEC / EN / UNE-EN 61558-2-4... Isolating transformer IEC / EN / UNE-EN 61558-2-6... Safety transformer UL 506... Control, isolating and safety transformer Characteristics Frequency... 50-60 Hz Protection degree... IP - 20 Ambient temperature (ta)... + 25 º C (IEC 61558) Relative humidity (without condensation)... < 95 % Safety class... Class I or Class II ( selectable) Instalation location... Indoor Duty... Continuous Test voltage (Dielectric Strength): - between Primary and Secondary... 4,6 KV - between Primary and Earth... 3,2 KV - between Secondary and Earth... 2,5 KV Voltage drop at nominal rating... < 5 % Eternal cover... Polymer of latest technology, non-flammable V-0 according to UL94 Isolations... Class B-130º C (IEC 61558) Windings... Copper HC-200º C (double enamelled) Cooling... (AN) Natural Aire Terminals... Screws with self-lifting supporting washers Earth terminal... Screws with self-lifting supporting washers Operation indicator... Led 1

Fast mounting system: enclosure suitable for mounting on DIN Rail 35 x 7,5 mm (EN 50022) up to 250 VA for easy mounting in electrical panels and switchboards. Separation of connections: by separations of technical polymer. Protection of connection terminals: by means of polycarbonate cover ( V-2 according to UL94 ) avoiding accidental electrical contacts. Dimensions and weights Reference Dimensions (mm) A B C D E Weight (Kg) P 25 69 92 80 79 45 5 0.64 P 40 69 92 80 79 45 5 0.79 P 63 84 101 98 88 55 5 1.1 P 100 84 101 98 88 55 5 1.6 P 160 106 123 118 110 74 5 2.3 P 200 106 123 118 110 74 5 2.7 P 250 106 123 118 110 74 5 3.3 P 315 118 138 131 121 88 6 4.1 P 400 118 138 131 121 88 6 4.9 P 500 136 162 156 145 104 6 5.8 P 630 136 162 156 145 104 6 6.8 P 800 136 162 156 145 104 6 8.6 Technical characteristics Reference Rating ta = + 25 ºC Instantaneous power cos θ = 0,5 No load voltage No load losses Short circuit losses Efficiency Short circuit voltage (100ºC) Vo Po Pk ( * ) η ( * ) Uk ( * ) VA VA % W W % % P 25 25 43 10 3.4 3.9 77.4 15.5 P 40 40 66 10 4.9 5.0 80.2 12.3 P 63 63 117 10 4.5 10.7 80.6 16.8 P 100 100 174 8 6.8 11.0 84.9 11.3 P 160 160 373 6.8 9.5 16.1 86.2 9.6 P 200 200 494 6.4 8.8 19.1 87.8 8.4 P 250 250 607 5.4 11 21.2 88.6 7.7 P 315 315 967 4.8 10.9 22.4 90.4 6.5 P 400 400 1256 4.4 12.9 24.2 91.5 5.9 P 500 500 1613 3.2 13.9 27.3 92.4 5.1 P 630 630 2440 2.8 19.7 25.4 93.3 4.0 P 800 800 3140 2.7 20.7 28.5 94.2 3.5 2

References of standard transformers Rating Secondary voltage Primary voltage 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V VA V References 25 230 / 400 PA 25 PB25 PC25 PD25 40 230 / 400 PA 40 PB40 PC40 PD40 63 230 / 400 PA 63 PB63 PC63 PD63 100 230 / 400 PA100 PB100 PC100 PD100 160 230 / 400 / 460 PA160 PB160 PC160 PD160 200 230 / 400 / 460 PA200 PB200 PC200 PD200 250 230 / 400 / 460 ---- PB250 PC250 PD250 315 230 / 400 / 460 ---- PB315 PC315 PD315 400 230 / 400 / 460 ---- PB400 PC400 PD400 500 230 / 400 / 460 ---- PB500 PC500 PD500 630 230 / 400 / 460 ---- ---- PC630 PD630 800 230 / 400 / 460 ---- ---- PC800 PD800 Selection of the safety class The transformer is delivered with default safety class setting: CLASS I which is indicated by the earth symbol below the earth terminal. The earth terminal is located at the secondary side, at the left side of the secondary terminals. Earth symbol To convert the transformer from CLASS I to CLASE II, please carry out the following steps: 1. Take out the screw and washer of the earth terminal. 2. Enter the plastic cover ( D ) in the hole of the earth terminal, press firm until it is well fixed into the terminal. ATTENTION: This cover can not be taken out once it is fixed. 3

Voltage selection system Before connecting the transformer, make sure that correct conductor sizes are used. In case the cables have diameter 3mm or less, it is not necessary to break the cable pass zone marked on the transparent cover. For cables with larger diameter, break the cable pass zone. Voltage selection according to transformer rating: Reference PA 6 V 12 V PB 12 V 24 V PC 24 V 48 V PD 115 V 230 V 25 and 40 VA 63 and 100 VA 1 2 3 1 2 3 7 8 9 7 8 9 10 160, 200, 250, 315, 400, 500, 630 and 800 VA EXAMPLE 2 460V 3 4 5 6 To select a supply voltage 400 V place the metal bridge between terminals 3 4 and connect the supply cables to terminals 2 6. 8 9 10 11 Placing the bridges between terminals 8 9 and 10 11, the lowest secondary voltage () is obtained between terminals 9 10. The metals bridges for voltage selection are included in the transformer box. 4

Protection type and rating A ) Protection at the primary side of the transformer: The supply circuit of the transformer should only be protected against short circuits, by means by a protection with rating of at least 2 times the nominal current of the transformer due to the inrush current of the transformer (about 20 times I nominal during 10 ms). PRIMARY RATING (VA) 230 V 400 V 460 V Rating Type Rating Type Rating Type 25 0.25 T 0.125 T ---- ---- 40 0.40 T 0.20 T ---- ---- 63 0.63 T 0.315 T ---- ---- 100 1.00 T 0.50 T ---- ---- 160 1.60 D, am 1.00 D, am 0.63 T 200 2.00 D, am 1.00 D, am 1.00 D, am 250 2.50 D, am 1.25 D, am 1.25 D, am 315 3.15 D, am 1.60 D, am 1.60 D, am 400 4.00 D, am 2.00 D, am 2.00 D, am 500 5.00 D, am 2.50 D, am 2.50 D, am 630 6.00 D, am 3.15 D, am 3.15 D, am 800 6.30 D, am 5.00 D, am 4.00 D, am T : T type, temporised fuse / am : am type fuse / D : magnetic circuit breaker, curve D B ) Protection at the secondary side of the transformer: The secondary side of the transformer should be protected against overloads, by means of a protection rated equal or inferior to the secondary current of the transformer. SECONDARY RATING (VA) 6V 12V 24V 48V 115V Rating Type Rating Type Rating Type Rating Type Rating Type Rating Type 25 4.00 gg, C 2.00 gg, C 1.00 gg, C 0.50 T 0.20 T 0.10 T 40 6.00 gg, C 3.15 gg, C 1.60 gg, C 0.80 T 0.315 T 0.16 T 63 10.00 gg, C 5.00 gg, C 2.50 gg, C 1.25 gg, C 0.50 T 0.25 T 100 16.00 gg, C 8.00 gg, C 4.00 gg, C 2.00 gg, C 0.80 T 0.40 T 160 25.00 gg, C 12.50 gg, C 6.00 gg, C 3.15 gg, C 1.25 gg, C 0.63 T 200 32.00 gg, C 16.00 gg, C 8.00 gg, C 4.00 gg, C 1.60 gg, C 0.80 T 250 ---- ---- 20.00 gg, C 10.00 gg, C 5.00 gg, C 2.00 gg, C 1.00 gg, C 315 ---- ---- 25.00 gg, C 12.50 gg, C 6.00 gg, C 2.50 gg, C 1.25 gg, C 400 ---- ---- 32.00 gg, C 16.00 gg, C 8.00 gg, C 3.15 gg, C 1.60 gg, C 500 ---- ---- 40.00 gg, C 20.00 gg, C 10.00 gg, C 4.00 gg, C 2.00 gg, C 630 ---- ---- ---- ---- 25.00 gg, C 12.50 gg, C 5.00 gg, C 2.50 gg, C 800 ---- ---- ---- ---- 32.00 gg, C 16.00 gg, C 6.00 gg, C 4.00 gg, C T : T type, temporised fuse / gg : gl gg type fuse / C : magnetic circuit breaker curve C 5