7E Series - Energy meter. Features PTB 1

Similar documents
Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Multi-voltage Multi-function. Wiring diagram (without control signal)

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

83 Series - Modular timers 16 A. Features

38 Series - Relay interface modules A

38 Series - Relay interface modules A

83 SERIES. 83 Series - Modular timers A. Features

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Energy Management Energy Meter Type EM110

2 or 4 pole changeover contact Plug-in/Faston 187

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Modular timers A

48 Series - Relay interface modules A. Features

C series Product brief

62.22 Copper side view

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

Energy Management Energy Meter Type EM110

24 V DC, 12 W output 12 V DC, 12 W output 24 V DC, 36 W output

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

87 Series - Modular timers 5-8 A. Features

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

38 Series - Relay interface modules A. Features /

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

3-phase energy meters with S0 pulse output

Energy Management Energy Meter GM3D

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Relay interface modules A

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Solid-State Relays Zero-point switching, without heatsink

02/11/2015

A rated contacts PCB mount - bifurcated terminals. Copper side view

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Introduction DIN rail mounted electricity meters

Type CP-S, CP-C & CP-A Switch mode

Multi-function 11 pin Plug-in for use with 90 series sockets

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

High precision measurement system for current and voltage IHC-A/B-RM01/03

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Electronic timer CT-TGD.22

Three-phase energy meter for transformer connection with S0 pulse output

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

The power in relays and timers since Catalogue

SMARTimer, digital timer 16 A

MID energy meter B21 Single-phase energy meter, 65 A

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDD.22

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

CP-E range Benefits and advantages

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Output Voltage nom. (adjustable)

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Energy Management Energy Meter Type EM340

CARREL-ELECTRADE LTD not just products... solutions!

Three-phase monitoring relays

7P Series - Surge Protection Device (SPD) Features 7P P P

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

38 Series - Relay Interface Modules A

Data sheet AWD3 3-phase, bidirectional energy meter for current converter metering with integrated S0-output Controls Division

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relay CM-PVE

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Three-phase monitoring relay

PD30ETD10xxSA. Photoelectrics, Diffuse reflective. Main features. Description

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Energy Management Energy Analyzer Type EM111

MINI-PS AC/2X15DC/1

Output Voltage nom. (adjustable)

PD140FNT60QMU-02C. Through Beam. Main features. Description

Relè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Transcription:

Features kwh Energy meter - 1-phase Type 7E.13 5(32) - 1 module wide Type 7E.16 10(65) - 2 module wide Complies with E 62053-21 and pre 50470 Complies with the EU MID-directive 2004/22/EG (Measuring Instruments Directive), mandatory for meters subject to legal regulation (from 31 Oct 2006) Certified by PTB (Physikalisch - Technischen Bundesanstalt) ccuracy class 1 Protection class Pulse output for remote energy management; SO interface (open collector) according DI 43864 to link the energy meter to a centrally located monitoring/management system Tamper-proof cover with lead seal facility available as an accessory Space saving small size 35 mm rail (E 50022) mount 7E.13.8.230.0000 ominal current 5 (32 Maximum) 1-phase 230 V C 17.5 mm wide -SO +SO 7E.16.8.230.0000 ominal current 10 (65 Maximum) 1-phase 230 V C 35 mm wide -SO +SO For outline drawing see page 5 Specification ominal/maximum current measuring Minimum measured current Current range (within accuracy class) Maximum peak current Supply (& monitored) voltage V C Operating range Frequency Hz Rated power W Display, Reading, Indication Max. totalising count/min. totalising count kwh ED- Pulses per kwh Open collector- output specification (SO+/SO ) Voltage (external supply) V DC Maximum current m Maximum leakage current @30 V/25 C µ Pulses per kwh Pulse length ms Internal series resistance Ω Maximum Cable length (30 V/20 m) m ccuracy class mbient temperature (Within accuracy class) C mbient temperature (Outside accuracy class) C Protective class Protection category: Housing/terminal pprovals (according to type) 5/32 10/65 0.02 0.04 0.25...32 0.5...65 960 (10 ms) 1,950 (10 ms) 230 230 (0.8...1.15)U (0.8...1.15)U < 0.4 < 0.5 Seven digit counter, red decimal digit, digit height 4 mm 999,999.9/0.1 999,999.9/0.1 2,000 1,000 5...30 5...30 20 20 10 10 1 1 10 + 10 + 20 +55 20 +55 IP 50/IP 20 IP 50/IP 20 PTB 1

Features kwh Energy meter - 3-phase Type 7E.36-0000 10(65) - Single tariff Type 7E.36-0002 10(65) - Dual tariff Complies with E 62053-21 and pre 50470 Complies with the EU MID-directive 2004/22/EG (Measuring Instruments Directive), mandatory for meters subject to legal regulation (from 31 Oct 2006) Certified by PTB (Physikalisch - Technischen Bundesanstalt) ccuracy class B Protection class Pulse output for remote energy management; SO interface (open collector) according DI 43864 to link the energy meter to a centrally located monitoring/management system Tamper-proof cover with lead seal facility available as an accessory 35 mm rail (E 50022) mount 7E.36.8.400.0000 ominal current 10 (65 Maximum) 3-phase 70 mm wide 1 2 3 (PE) 3 x 230 V C / 50 Hz 7E.36.8.400.0002 ominal current 10 (65 Maximum) 3-phase Dual tariff (Day and ight) 70 mm wide 1 2 3 (PE) R T1,T2 = Tariff switching equipment R T1,T2 3 x 230 V C / 50 Hz +SO -SO E1 E2 +SO -SO 1 1 2 2 3 3 1 1 2 2 3 3 For outline drawing see page 5 Specification ominal/maximum current measuring Minimum measured current Current range (within accuracy class) Maximum peak current Supply (& monitored) voltage V C Operating range Frequency Hz Rated power per phase W Display, Reading, Indication Max. totalising count/min. totalising count kwh ED- Pulses per kwh Open collector- output specification (SO+/SO ) Voltage (external supply) V DC Maximum current m Maximum leakage current @30 V/25 C µ Pulses per kwh Pulse length ms Internal series resistance Ω Maximum Cable length (30 V/20 m) m ccuracy class mbient temperature C Protective class Protection category: Housing/terminal pprovals (according to type) 10/65 10/65 0.04 0.04 0.5...65 0.5...65 1,950 (10 ms) 1,950 (10 ms) 3 x 230 3 x 230 (0.8...1.15)U (0.8...1.15)U < 1.5 < 1.5 Seven digit counter, red decimal digit, digit height 4 mm 999,999.9/0.1 999,999.9/0.1 5...30 5...30 20 20 10 10 B B 25 +55 25 +55 IP 50/IP 20 IP 50/IP 20 PTB 2

Ordering information Example: Energy meter 32 /230 V C, with PTB certified, accuracy class 1, available with Tamper-proof lead sealed cover as accessory, for 35 mm rail (E 50022) mounting. 7 E. 1 3. 8. 2 3 0. 0 0 0 0 Series Function 1 = 1-phase 3 = 3-phase Current 3 = 32 6 = 65 Supply version 8 = C 50 Hz Option 0 = Standard 2 = Dual tariff (7E.36 only) Supply voltage 230 = 230 V C 50 Hz 400 = 3 x 230/400 V C 50 Hz ll versions/width 7E.13.8.230.0000/17.8 mm 7E.16.8.230.0000/35 mm 7E.36.8.400.0000/70 mm 7E.36.8.400.0002/70 mm Insulation E 62053-21 7E.13, 7E.16 7E.36 Insulation rated voltage V 250 250 Overvoltage category IV IV Isolation between active part SO+/SO terminals kv (1.2/50 µs) 6 6 adjacent phases kv (1.2/50 µs) 6 Insulation between supply and SO+/SO V C 4,000 4,000 between adjacent phases V C 4,000 Protection class EMC Specification Reference standard Electrostatic discharge contact discharge E 61000-4-2 8 kv air discharge E 61000-4-2 15 kv Radio-Frequency Electromagnetic Field (80...1,000)MHz E 61000-4-3 10 V/m Fast Transients (Burst) (5-50 ns, 5 khz) on Supply Terminals E 61000-4-4 Class 4 (4 kv) on SO+/SO Terminals E 61000-4-4 Class 4 (2 kv) Surge (1.2/50 µs) on Supply Terminals E 61000-4-5 Class 4 (4 kv) on SO+/SO Terminals E 61000-4-5 Class 3 (1 kv) Radio-Frequency Common Mode (0.15...80)MHz on Supply terminals E 61000-4-6 10 V Radiated and Conducted Emission E 55022 Class B Other data Pollution degree 2 Vibration resistance (10...60)Hz mm 0.075 (60...150)Hz g 1 Vibration resistance of the internal mechanical counter (10...500)Hz g 2 Schock resistance g/18 ms 30 Schock resistance of the internal mechanical counter g/18 ms 350 Power lost to the environment 7E.13 7E.16 7E.36 without current W 0.4 0.4 1.5 with maximum current W 1 2 6 Supply terminals 7E.13 7E.16, 7E.36 Max. wire size solid cable stranded cable solid cable stranded cable mm 2 1...6 0.75...4 1.5...16 1.5...16 WG 18...10 18...12 16...6 16...6 Screw torque for I max m 0.8...1.2 1.5...2 Screw M4 Pozidrive o.1, Phillips o.1, Flat o.1 SO+/SO terminals Max. wire size solid cable stranded cable solid cable stranded cable mm 2 2.5 1.5 2.5 1.5 WG 14 16 14 16 Screw torque for I max m 0.5 0.8 Screw M3 Pozidrive o.1, M4 Pozidrive o.1, Phillips o.1, Flat o.1 Phillips o.1, Flat o.1 3

ED indication (ormal operation) Type Energy consumption one ow High Pulses per kwh Pulse space The ED Pulse rate represents the instantaneous power being consumed, according to the following 7E.13 2,000 100 ms kw = (number of pulse per Minute) / 33.3 7E.16 1,000 100 ms kw = (number of pulse per Minute) / 16.7 7E.36 100 150 ms kw = (number of pulse per Minute) / 1.7 ED indication (bnormal operation) Status indicates errors of installation, as below Type 7E.13 7E.16 Device O, incorrect connection (- inverted). Mark = 600 ms, Space = 600 ms 7E.36 Mark = 100 ms, Phase 1 1 inverted or loss Phase 2 2 inverted or loss Phase 3 3 inverted or loss Phase 1 1 and 2 2 inverted or loss Phase 1 1 and 3 3 inverted or loss Phase 1 1 and 2 2 and 3 3 inverted or loss SO+/SO Open collector output wiring diagram The pulsating open collector output available at terminals SO+ and SO can be interfaced with the input of a computer, plc or other energy management equipment to allow the remote monitoring of energy consumed. + 24 V DC Energy meters at difference locations (ote: Both Single and Dual tariff meters provide only a single pulsating output) Central monitoring/management system (max. 20 m for each input) 4

Outline drawing 17.5 63 31 85 89.2 35.6 62.1 85 82 23.8 44 35 62 7E.13.8.230.0000 7E.16.8.230.0000 31 82 70 62 ccessories Terminal cover for type 7E.13 07E.13 For the tamper-proof lead seal use 2 terminal cover 07E.13 Terminal cover for type 7E.16 and 7E.36 07E.16 7E.16 - For the tamper-proof lead seal use 2 terminal covers 7E.36 - For the tamper-proof lead seal use 4 terminal covers 07E.16