G4 Generator. Four-Electrode Radiofrequency Generator. The Leader in RF Medicine Since 1952

Similar documents
COSMAN The Leader in RF Medicine Since 1952

Leksell Neuro Generator

Radio Frequency Electrosurgical System Specialist

Lumbar Transforaminal

2D, 3D CT Intervention, and CT Fluoroscopy

WRIST ARTHROSCOPY SYSTEM

2012 Monitored Rehab Systems E1201 Manual Kneelax. Installation and user manual

577 nm: The Preferred Wavelength

Robots in the Field of Medicine

CALYS 75. Field documenting multifunction calibrator

Ultimate DR flexibility

FMT18 FLOOR MOUNTED SYSTEM

VNS Therapy System Overview and Dosing

The First True Color Confocal Scanner

Recorders OUR MOST COMPACT CHART RECORDER! Input Number Chart Special Description Type of Pens Size Options Page

INTELECT SHORTWAVE DIATHERMY MOVING REHABILITATION FORWARD

troubleshooting LEVEL 1 training

OTC18 OVERHEAD TUBE CRANE SYSTEM

Impressive Wide Field Image Quality with Small Pupil Size

GE Medical Systems. OEC 9800 Plus. Digital Mobile Imaging System. imagination at work

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

CALYS 100. Field precision documenting multifunction calibrator

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

K nk Valve 10 Year Limited Warranty

CALYS 50. Field multifunction calibrator for basic use

GE AMX 4+ Portable X-Ray

The First True Color Confocal Scanner on the Market

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

Quantum Medical Imaging

CALYS 150. Advanced documenting multifunction calibrator thermometer

Balancing accuracy......and great efficacy

Loop calibration and maintenance

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

Additel 875 Series Dry Well Calibrators

Technical data ESA614 Electrical Safety Analyzer

Maximizing clinical outcomes

SKYBOX. 5-channel Digital EMG, NCS and EP System

The First True-Color Wide-Field Confocal Scanner

Vascular. Development of Trinias Series unity edition Angiography Systems. 1. Introduction. 3. Three Concepts of "unity"

Additel 875 Series Dry Well Calibrators

Progeny Imaging Veterinary

Fluke 712B and 714B Temperature Calibrators

ddraura Series Productivity meets versatility

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame

Q3D. Speak to a 3D Specialist. CBCT 3D / Panoramic Imaging GENERAL DIMENSIONS. Suni Imaging Product Lines GET.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Compact design. Clinical versatility.

UTILITY LOCATING EQUIPMENT

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software.

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

th St N Suite 113 Largo, FL (888) (888) Fax

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

SOCRATES. Auditory Evoked Potentials

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

FRAX Series Sweep Frequency Response Analyzers

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Fluke Clamp Meters Solutions for every need

ALPHASHOT MICRO IN-HOUSE MACRO PHOTOGRAPHY STUDIO CUT COSTS INCREASE SALES SPEED UP WORKFLOW

1510A PRECISION SIGNAL SIMULATOR

VA L U E A N A LY S I S B R I E F

TRAX Transformer and Substation Test System

MH8001 Four Channels Pre-Programmed TENS and EMS combo device

VERCISE DIRECTIONAL SYSTEMS* VERCISE NEURAL NAVIGATOR 2.1 PROGRAMMING TUTORIAL

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Neurosurgery with ultrasonic technology by Söring: fine preparation and effective dissection

TCM4 Series. Product line for transcutaneous monitoring

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Horizon. Your innovative partner in medicine technology.

Three-Phase Transformer Demagnetizer DEM60

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

Emprint Ablation System with Thermosphere Technology

Application Note 175 Using the STMISOC Stimulus Isolator

GC723A / GC724B Cable and Antenna Analyzer

Front View 3 2. Selection and Operating Elements

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

HF- GENERATORS.

Signet 2750 DryLoc ph/orp Sensor Electronics

Just Load and Go. Put sterilization in the trusted, dependable hands of STERRAD Systems. Introducing STERRAD Systems with ALLClear Technology

SERVICE MANUAL. Dynatron 950plus & Dynatron 650plus

Ground Bond & Optional HV & HC Scanner. Ground Bond & Functional Run Test. Ground Bond, Functional Run Test & Line Leakage Test. Features and Benefits

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

Automatic hardness testing devices

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Digital Electric Micrometer. DEG2000 Instruction Manual

Quick Start Guide for the PULSE PROFILING APPLICATION

DIGITAL IMAGING WITHOUT LIMITS. Your Complete Digital X-Ray Solution. Wireless. Flexible. Every image SIZE.

Signet 9950 Dual Channel Transmitter

ENDOSCOPIC ULTRASOUND SYSTEMS

Cassette DR Solution. FDR D-EVO G43i. Square shaped cassette enabling enhanced operability and multipurpose use ISS. Wireless

DC Electronic Loads 8500 series

Progeny Imaging. User Guide V x and Higher. Part Number: ECN: P1808 REV. F

BLACKBIRD Spinal System

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Weld Checkers RESISTANCE WELDING

Ysio Max. The most direct way to the image. Answers for life.

HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM

Transcription:

G4 Generator Four- Radiofrequency Generator The Leader in Medicine Since 1952

Pioneers of Radiofrequency Cosman s Historic Firsts in Medicine Landmark inventions by Bernard J Cosman, MS (MIT) and MIT Professor Eric R Cosman, Sr, PhD 1938-2000 Founded and owned Radionics, the world leader in medicine until its sale. 1950 s First commercial radiofrequency generator (1952) First temperature-monitoring electrode First impedance monitor 1960 s First facet denervation electrode with Dr. Shealy First trigeal neuralgia electrode with Dr. Sweet First cordotomy electrode with Dr. Rosomoff 1970 s First medial branch TC electrode with Dr. Sluijter First curved trigeal electrode with Dr. Tew First TC cordotomy electrode with Dr. Levin First DREZ electrode with Dr. Nashold 1980 s First intradiscal heating with Dr. Sluijter First cardiac ablation generator First CT cordotomy electrode with Dr. Kanpolat 1990 s Invented pulsed (P) with Dr. Sluijter et al. First pulsed generator, the G-3C+ First curved cannulae with Drs. Racz & Finch First generator for tumor ablation First cooled electrode with Dr. Goldberg The Next Generation of Innovation The latest advances from Prof Eric R Cosman, Sr, PhD and Eric R Cosman, Jr, PhD (MIT) 2004-present Founded Cosman Medical. G4 four-electrode, touch-screen generator G-1A & 1B generators with simplified controls Fundamental discoveries in & P biophysics 1, 2 First palisade for sacroiliac joint (SIJ) pain 3 1950 s G-2 1960 s G-3A 1970 s G-5 1980 s G-3B 1990 s G-3C+ 1971: MIT Professor Eric R Cosman, Sr, PhD and his father, Bernard J Cosman, MS (MIT) in the Radionics booth at the American Association of Neurological Surgeons (AANS) congress. 2007: Eric R Cosman, Jr, PhD (MIT) and his father, Professor Eric R Cosman, Sr, PhD in the Cosman Medical exhibition booth at the International Spine Intervention Society (ISIS) congress. 1 Cosman ER Jr, Cosman ER Sr. Electric and Field Effects in Tissue Around Radiofrequency s. Pain Medicine 2005; 6(6):405-24.

Superior, Efficiency, and Ease of Use The Most Advanced Generator Ever Built ersion 2 of the popular G4 generator builds on Cosman s tradition of performance, safety, and quality in pain management and neurosurgery with the widest available range of features: Intuitive 12 touch screen Large color-coded readings control with knob or screen Automatic stimulation ramp Simultaneous or stagger start of electrodes Two interface options: One Touch: Simple, digital Graphing: Advanced, graphical Enough power to heat four 16ga cannula Multi-bipolar for SI joint pain E-dose control Full operability with 12 touch screen or wireless remote. The upright screen is visible from a distance. Optional knob control. Unparalleled Capability. Unmatched Simplicity. Wireless Remote Control Nitinol, standard, or disposable electrodes. Smooth steerable cannulae of all sizes. 10mm 12mm Treat Four Sites At Once Automatic and Independent Control. Simultaneous or Auto Stagger Start. Faster & s. 15mm SI Joint Palisade TM Kit Bipolar and guide block produce a more complete SIJ lesion zone with fewer lesions. 3 Create two bipolar lesions at once. Genicular Treating multiple nerves at the same time can save time and reduce costs. 2 Cosman ER Jr, Dolensky JR, Hoffman RA. Factors That Affect Radiofrequency Heat Lesion Size. Pain Medicine 2014; 15(2):2020-36. 3 Cosman ER Jr, Gonzalez CD. Bipolar Radiofrequency Lesion Geometry: Implications for Palisade Treatment of Sacroiliac Joint Pain. Pain Practice 2011; 11(1):3-22.

Preset: Medial Branch Electorde Type = Standard Active s = 1 Sensory Rate = 50 Hz Senory Width = 1 Sensory Auto Ramp = Off Motor Rate = 2 Hz Motor Width = 1 Motor Auto Ramp = 2.0 Ramp Speed = Fast Control Units = oltage Doctor Info Name = Best Deptartment = Anesthesiology Hospital = University Hospital Set Temp = 90 Set Time = 1:30 Stagger Start = 0 sec Mode = Standard Auto Ramp = On Max Temp = 42 Set Time = 1:30 Set oltage = 45 Pulse Rate = 2 Hz = 20 Stagger Start = 0 sec E-dose = oltage Auto Ramp = On Interface = One Touch Cosman G4: Simple Customizable Workflow with Uni Two Interfaces to Satisfy Diverse Needs Select a different interface for each doctor preset. oltage 20 2.0 W 1 100mA One Standard Stepped Set Temp Set Time 1:30 One Touch Interface ery large displays Simplified touch screen controls Useful in a busy practice Choose either the simplicity of full touch screen automation or the precision of manual knob control 100 80 60 40 20 0 0:30 1 100 ma 1:00 20 2.0 W One 70 53 35 18 0 1:30 Reset Set Temp Settings Set Temp Set Time 1:30 Mode Standard Auto Ramp On Change Graphing Interface Graph temperature and voltage Knob or touch screen control Useful for advanced treatments 1 Load stored procedure settings, doctor and patient information. Start Patient Database Select Preset Cordotomy Functional Stereotaxy Intradiscal Medial Branch Palisade SIJ Pallidotomy DRG Splanchnic Nerve Sympathectomy Thoracic Medical Branch Trigeal Neuralgia Doctor Presets Store hundreds of procedure settings for multiple doctors. Select Patient Jump to... Edit info... Last Name First Name ID Belden Anne 061022 Fritz Albert 571043 Holder Richard 111920 Jenkins Diane 985623 Salinas Carlos 982833 Tyler Walter 229340 an Dieren Teus 923284 Zedillo Miguel 888231 New Delete Delete All DOB 1954-10-03 L3-L5 R Medial Branch 1962-02-15 T6-7 L/R Medial Branch 1944-08-30 C2-4 L DRG 1968-03-19 Trigeal 2/3 R 1958-09-09 Sacroiliac Joint Palisade 1963-03-15 L3-L5 L Medial Branch 1956-07-23 C3-5 L/R DRG 1970-01-17 L4-5 L Medial Branch Patient Database Store patient names, IDs, DOBs, and notes. Recall on repeat appointments. Modify Presets Cancel Start Cancel Ok 2 Perform procedure. Adjust electrode setup, settings, notes, and site labels as desired. One Motor One One One Type Active s Labels Standard Bipolar 1 2 3 4 Edit Clear All Connect as Shown G 1 2 3 Labels 1: Not specified 4 1 oltage 0.1 0.01 1.19 37 Sensory Motor Pulse Rate 2 Hz 1 oltage Ramp 1.2 oltage 20 2.0 W 1 100mA Standard Stepped Set Temp Set Time 1:30 42 oltage 45 6 1 474 ma Max Temp 42 Set Time 1:30 Set oltage 45 Pulse 2 Hz 20 Intuitive color-coded screens and large displays 3 Print or export procedure record. Or save on G4 for later export. Print procedure summary directly to a USB printer Export electronic records to USB thumb drive JPEG screen shots for records & presentations Plot & analyze data for clinical research

Four s que Automation, Control, and Record Features Four s e 2 3 4 Radiofrequency Custom 100 Settings 70 100 Custom 70 100 Settings Simultaneous or automatic stagger start of up 70 100 70 80 53 80 53 80 53 80 53 to four electrodes One One 60 35 60 35 60 35 60 35 40 18 40 18 40 18 40 18 Smooth automatic temperature control for large and small electrodes Displays of all crucial readings: 20 0 0 0:45 1:30 0 0:45 1:30 0 0:45 1:30 0 0:45 1:30 olts, Milliamps, Watts, 1and Oh 1 One One 100 ma 210 Ω 100 ma 230 Ω 117 ma 150 ma Automatic staggering of electrode activations oltage, current, or power control for multiple non-tc electrodes (CR) 2.0 W 2.1 W 3.2 W 4.5 W quickly identifies problem electrodes Reset Patented technology for energizing 42 multiple electrodes 42 1 1 One One Proprietary algorith accelerate heating 42 A broad range of temperature 42 settings 1(37-95 ) 1 Max TempSet Temp Max Temp oltage oltage 70 100 Intradiscal stepped temperature 70 progra 100 Elapsed 70 Time 42 42 42 45 42 45 200 Max Set Time Temp Max Set Time Temp The oltage widest range of pulse settings: oltage Rate 1-10 Hz, 53 80 53 80 Ω 53 Ω1:30 42 1:30 Push-button adjustment 42 of the automatic Width 2-30 ec, oltage 0-100 45 45200 set temperature during lesioning E-dose: Automatic control of pulse settings to Set Settings Max Set oltage Time Temp Set Max Set oltage Time Temp oltage oltage 35 60 optimize nerve exposure to 35 the electric 60 field 1 Ω 35 Set 1:30 45 6 474 Temp Ω 42 80 1:30 42 45 45 6 480 khz waveform for optimal P effect 200 474 45 1 200 Pulse Set Set oltage Time 1:30 Pulse Set Set oltage Time 18 40 Low and high-temperature 18 P (37-95 40 ) ma ma 1 Hz 18 30 6 474 Stagger 45 6 Hz Ω 1:30 7 Ω Start 1:30 045 6 474 sec Mode Pulse Set oltage Standard Pulse Set oltage ma ma 2 Hz 0 20 Sensory & Motor 6 Auto 45 8 Hz Ramp 455 On 1:30 0 6 474 0:45 1:30 474 0 0:45 1:30 Pulse Pulse Automatic : Choose slow or instant-on ramp rate COSMAN G4 ersion 2.0.4 COSMAN G4 ersion 2010-11-19 2.0.4 ma2010-11-19 2:08 PM ma 4 Hz 102:08 PM 10 Hz 4 Manual : Use knob or on-screen buttons Change Select any P 2, 3,..., 30 ec 00 ma Mark the final 230 stimulation level Ω for 117 true electronic ma record keeping 150 ma Select any P Pulse Rate 1, 2,..., 10 Hz COSMAN G4 ersion 2.0.4 COSMAN G4 ersion 2010-11-19 2.0.4 2010-11-19 2:08 PM 2:08 PM Audible impedance tone for cordotomy and intradiscal placement W Support for both spinal and 3.2 W neurosurgical procedures: 4.5 W Rate 2-200 Hz, Width COSMAN 0.1-3 G4 ec, ersion voltage 2.0.4 or current COSMAN G4 control ersion 2010-11-19 2.0.4 2010-11-19 2:08 PM Motor 2:08 PM One 27 30 User Friendly in Multiple Languages Clear labeling and helpful troubleshooting messages simplify usage in a variety of selectable languages. 4 2010-11-19 2:08 PM Type Active s Labels Four s Reglages Personnalisés Configuration des Électrodes Quatre Électrodes Connect as Shown G 1 2 3 Otros Parámetros Configuración de Electrodos 4 Cuatro Electrodos Standard Bipolar Connecter Comme Indiqué G 1 2 3 4 Type Standard Bipolaire Conecte según se muestra G 1 2 3 4 1 2 Tipo 3 de 4 Estándar Bipolar Électrodes Actives Edit Positions 1 2 3 4 Labels Electrodos Clear All 1: Not specified 1 2 3 4 Activos 2: Not specified Positions 3: Not specified Modifier Effacer Électrode 1: Non specifié 4: Not specified Électrode 2: Non specifié Etiquetas Etiquetas Électrode 3: Non specifié Modificar Borrar Electrodo 1: Sin especificar Électrode 4: Non specifié Electrodo 2: Sin especificar Electrodo 3: Sin especificar Electrodo 4: Sin especificar Électrodes Thermique Pulsée Terer Electrodos EStim Notas Térmica Pulsada Terar 1 2 3 4 20 21 27 30 Sensory 1 1 0.5 ma 0.1 ma OFF 2.0 ma 0.5 ma 0.1 ma 250 Ω 37 50 1 250 Ω 37 One Ramp OFF COSMAN G4 ersion 2.0.4 2010-11-19 2:08 PM Sensory Motor Pulse Rate Hz Start Sensory Motor Pulse Rate 2 Hz 1 Ramp 6 ma Select and preset manual or automatic control for sensory and motor modes separately Calibration and Safety Checks Ongoing checks of temperature and other readings confirm accuracy and control. Self-diagnostic tests of hardware and software verify proper function. Reset Set Temp Settings Set Temp Set Time 1:30 Stagger Start 0 sec Mode Standard Auto Ramp On Change

Wide Range of Pain Management and Neurosurgical Reliable Thermocouple (TC) s Choose a direct 3-meter connection to the generator, or an extension cable Colored to match cannulae shaft lengths: 5, 10, 15, 20 cm Compatible with both straight and curved cannulae of any gauge Nitinol (TCN) Made from Nickel-Titanium memory metal Improved durability to daily use and autoclaving Nitinol (TCN) Standard (CSK) Disposable (TCD) Standard (CSK) Disposable (TCD) Autoclavable for reuse in multiple procedures Cost-effective and reliable Sold sterile-packed to eliate sterilization planning Eliate the possibility of disease transmission Smooth Steerable Cannulae Straight (CC) or Curved (K) 5, 10, 15, 20 cm shafts 2, 4, 5, 10, 15 mm tips 22, 21, 20, 18, 16 gauge Sharp or Blunt Siliconized Echogenic Curved Sharp (K-C101018S) Curved Blunt (K-C101020B) Straight Sharp (CC101022) SideKick Tapered insulation for smooth maneuvering Disposable Injection s & Needles Keep your target while injecting through long fluid line Tissue piercing, steerable, smooth shafts: 5, 10, 15 cm Small hub with marker for injection direction Injection -Control (CU) Many sizes, straight & curved tips. US Patent 7,862,563. Injection (CR) 5mm tip for voltage-control, shrouded connector Injection (CP) 1mm tip for precise stimulation-guided blocks Block Injection Needle (CN) High quality, reliable, low cost Unitized /Cannula with Injection & Control (CU)

s, Cannulae, and Accessories 12mm 10mm Sacroiliac Joint (SIJ) Palisade TM Kit Guide block simplifies alignment and placement of cannulae Bipolar creates larger heat lesions than cooled as used in pain management 2, 3 Bipolar produces a more complete SIJ lesion zone in less time, with fewer lesions, using smaller cannulae 2, 3 Even faster with the G4: Create two bipolar lesions at once 15mm Knee and Hip Pain Radiofrequency ablation is a non-surgical, non-narcotic treatment option for those who are not candidates for invasive surgery Treating multiple nerves at once saves time and reduces costs Flextrode TM Disc Kit An extendable electrode with curved introducer simplifies targeted intradiscal placements Automatic stepped-temperature progra Targeted Intradiscal Trigeal Neuralgia Kits TEW Curved TIC Straight s Cordotomy Kits Autoclavable or Disposable Includes spinal needles Use X-ray or CT guidance Trigeal Neuralgia (TEW, TIC) Cordotomy: Reusable (LCE), Disposable (LCED) Stereotactic Brain s Adapt to most stereotactic frames Thalamotomy, Pallidotomy, Cingulotomy for treatment of movement disorders and intractable pain DREZ Kits Spinal DREZ Kit (NTCD) Nucleus Caudalis Kit (ENA) Stereotaxy (TC): Numerous sizes available DREZ (ENA, NTCD)

Percutaneous radiofrequency denervation of lumbo-sacral facet and sacroiliac joints is a simple and effective way to treat spinal pain. Radiofrequency Treatment of the Trigeal Nerve Enables Selective Destruction of Pain Fibers While Preserving Touch and Motor Function in the Face G4 Four-Output Radiofrequency Generator COSMAN Radiofrequency Treatment of the Lumbar Medial Branch by Charles A. Gauci, MD, FRCA, FIPP, FFPMRCA Technique Series COSMAN Percutaneous Stereotactic Radiofrequency Treatment of Trigeal Neuralgia Technique Series by John M.Tew, Jr., MD, FACS, and Andrew Grande, MD Wireless Remote Control (G4-M) Step-by-step Guides Footswitch (FS-1) G4 Cable Organizer (G4-CO) G4 Four- Generator Cordless Ground Pad (DGP-PMC) CR Injection Organizer (CR-CO) Ground Pad (DGP-PM) Sterile Test Pad (G-STP) Test plugs verify calibration and control (G-TP) (480 khz carrier frequency) Auto Temp: Off, 37 95 Auto Timer: 5 sec 30 Auto Stepped: Start, Step, Final Temps and Times : 0 50 Watts (480 khz carrier frequency) Auto : Off, 37 95 Auto Timer: 5 sec 30 oltage: 0-100 olts Peak Rates: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Hz Widths/Durations: 2, 3,..., 30 ec E-dose: Control oltage or (Biphasic Square Pulses) Rates: 2, 5, 50, 75, 100, 150, 180, 200 Hz Widths/Durations: 0.1, 0.5, 1, 2, 3 ec oltage Control: 0-3 olts Control: 0-10 ma Monitor: 30 3000 Ω Monitor: 0 110 USB Export: PCL3 Printer, Flash Drive (TXT, JPEG) Size: 14.2 9.5 12.2 in 3 (36.2 24.1 30.0 cm 3 ) Touch Screen: 12.1 in (30.7 cm) Weight: 22 lbs (10 kg) Electric Supply: 100, 120, 220, 240 ac; 50/60 Hz Designed and Built by Cosman Medical Like all Cosman products, the Cosman G4 radiofrequency generator is designed, manufactured, and serviced by our own engineers and technicians to ensure superior quality control, faster service, and cost savings that we pass on to our customers. Cosman Medical, Inc. is an ISO 13485 certified company. The G4 is indicated for use in procedures to create radiofrequency lesions for the treatment of pain, and for lesioning nerve tissue for functional neurosurgical procedures. Part # G4 G4-M FS-1 G-STP G-TP SC-2 CB112-TC CB114-TC CB116, CB116-4 DGP-PM-5,10,25 G-1A & 1B One- Generators Description Four- Generator Wireless Remote Control Foot Switch Sterilizable Test Pad with Cable Output Test Plug Storage and Carrying Case 2.4 m Cable, Connects TC to G4 2.4 m Cable, Connects Disposable TC to G4 2.4 m Cable, Connects CR/CP (s) to G4 Disposable Ground Pad, 5, 10, or 25/pk www.cosmanmedical.com Rx Only. Read Instructions for Use before use. Some products not available in all countries. Tel: +1 781 272 6561 Fax: +1 781 272 6563 info@cosmanmedical.com 2016 Cosman Medical, Inc. Cosman Medical, Inc. 22 Terry Avenue Burlington, MA USA 01803 SPI11682 Rev C 20160321