GAFIK Systems GX-IPS-WH Sensor GX-IPS-WH 369302c 1 06.22.17 Description The GX-IPS Sensor uses an infrared transmitter/receiver pair to detect partition movement and, in conjunction with other Lutron products, coordinates lighting preset functions in areas such as partitioned meeting rooms or ballrooms. The GX-IPS may be used with GAFIK Eye 3000 or 4000 systems, GAFIK Eye, Energi Savr ode, or Quantum systems. Features Automatically combines lighting preset functions when partition is open creating one large space. Lighting preset functions become independent as partition is closed creating several smaller spaces. For operation with GAFIK Eye 3000 / 4000 system, the GX-IPS requires an interface (GX-I) and a power supply (GX-12D or PP-D). For operation with GAFIK Eye,or Energi Savr ode systems, the GX-IPS requires an interface (E-I) and a power supply (GX-12D or PP-D). For operation with Quantum, the GX-IPS requires either an interface (E-I) or wallstation with contact closure input (WS2-, WA-, or similar) and a power supply (GX-12D or PP-D). Job ame: SPEIFIATI SUBMITTAL Model umbers: Job umber:
GAFIK Systems Specifications GX-IPS-WH 369302c 2 06.22.17 Power perating voltage: Low-voltage PEL (lass 2: USA) 12 24 -, 135 ma. Lutron recommends using a GX-12D plugin power supply or a PP-D power supply (both ordered separately). ne GX-12D can supply power to five sensor transmitter/receiver pairs. ne PP-D can supply power to one sensor transmitter / receiver pair. Transmitter and receiver have reverse polarity and short-circuit protection. onnection Wire leads provided. Finish White painted plastic. Environment 32 F 104 F (0 40 ). elative humidity less than 90% non condensing. Mounting Surface mount indoors only. Sensor Status Indicator eceiver and transmitter includes an LED indicator that assists in sensor alignment during installation and provides sensor operating status. Transmitter LED will be green when properly powered and transmitting eceiver LED will be orange when receiving beam and not illuminate when blocked. System apacity Each GX-I or E-I Interface (prefix WS2-, WA-, or similar; ordered separately) can accommodate up to five GX-IPS partition sensors for five different moveable walls. Each seetouch wallstation (ordered separately) can accommodate one GX-IPS partition sensors for one moveable wall. ontact losure utput from GX-IPS is configurable to ormally pen or ormally losed from receiver unit. Job ame: SPEIFIATI SUBMITTAL Model umbers: Job umber:
GAFIK Systems Dimensions and Mounting GX-IPS-WH 369302c 3 06.22.17 eceiver and transmitter surface mount in 1-gang U.S. wallboxes 3.5 in (89 mm) deep, mounted facedown from the ceiling. Indoor use only. The sensors must be mounted in a position where the partition separates the transmitter and receiver when the partition is closed. Transmitter and receiver may be located no more than 8 ft (2.43 m) apart. Adjustable mounting brackets allow easy alignment during installation. Wires feed through the back of the transmitter/receiver. Side iew Standard single-gang U.S. wallbox mounted facedown and flush with ceiling surface (typical of two). 1.5 in (38 mm) eiling GX-IPS-WH Transmitter GX-IPS-WH eceiver 8 ft (2.43 m) maximum Top iew Single gang wallbox (typical of two) Wallbox mounting line of center Job ame: SPEIFIATI SUBMITTAL Model umbers: Job umber:
LUT +1.610.282.3800 www.lutron.com + 87654321 0-24 0-24 1 A 1 A 0-24 0-24 ½ A ½ A + 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 243 ID. T. EQ. 0-24 1 A 0-24 ½ A GAFIK Systems System Diagrams GX-IPS-WH 369302c 4 06.22.17 GAFIK Eye 3000 and 4000 Systems eiling GX-IPS oom A GX-IPS eceiver (X) oom B (GX-12D or PP-D) Wallstations M I M 5 I I 4 5 I I 3 4 I 2 3 I 1 2 I 1 5 M 5 M 5 5 5 4 4 3-4 M 4 3-4 M 3 3 3 2 2 1-2 2 M 1 1-2 M 1 1 M 1 21 23 43 4 M + P/ 500-10728 P/ 500-1072 GX-I 24 200 ma 24 200 ma +1.610.282.3800 www.lutron.com Wallstations 1 1 2 2 3 3 4 4 5 5 PGM PGM GX-I or MX-I PEL (lass 2: USA) ontrol Link GAFIK Eye System, Energi Savr ode System, Quantum System eiling GX-IPS Transmitter oom A GX-IPS eceiver oom B To I1-5 (GX-12D or PP-D) E-I Energi Savr ode Quantum Hub 1 2 3 4 5 Wallstation GAFIK Eye E-I- 24 200 ma 1.610.282.3800 Wallstation 3 2 2 1-2 M 1 1 3 4 3-4 M 4 5 M 5 5 M + M I 5 I 4 I 3 I 2 I 1 Job ame: SPEIFIATI SUBMITTAL Model umbers: Link Job umber:
GAFIK Systems GX-IPS-WH Wiring Diagrams 8 7 6 5 4321 1 2 3 4 5 369302c 5 06.22.17 GAFIK Eye 3000 and 4000 Systems E-I- 24 200 ma + 1.610.282.3800 243 ID. T. EQ. 0-24 1 A 0-24 ½ A E-I 1-2 M 1 1 2 2 4 4 3-4 M 3 3 5 M 5 5 M + M I 5 I 4 I 3 I 2 I 1 Black GX-12D GX-IPS oom A GX-IPS eceiver (X) oom B eiling ote: Diagram represents a single partition. A E-I will accomodate up to five GX-IPS partition sensors (five partitions). A single GX-12D will power up to five GX-IPS partition sensors. ote: The E-I is programmed for partition mode. Set input closures for maintained inputs (refer to the E-I installation instructions). 87654321 2 3 4 5 1 E-I- GAFIK Eye System, Energi Savr ode System, Quantum System 24 200 ma + 1.610.282.3800 243 ID. T. EQ. 0-24 1 A 0-24 ½ A E-I 1-2 M 1 1 2 2 4 4 3-4 M 3 3 5 M 5 5 Black M + M I 5 I 4 I 3 I 2 I 1 Black (ommon) ed (24 -) (ontrol) PP-D Black (Line/Hot) White (eutral) ed ed eiling GX-IPS oom A GX-IPS eceiver (X) oom B ote: Diagram represents a single partition. A E-I will accomodate up to five GX-IPS partition sensors (five partitions. A single PP-D will power up to five GX-IPS partition sensors. ote: The E-I is programmed for partition mode. Set input closures for maintained inputs (refer to the E-I installation instructions). )Lutron, Lutron, GAFIK Eye, Quantum, and seetouch are trademarks of Lutron Electronics o., Inc., registered in the U.S. and other countries. Energi Savr ode and GAFIK Systems are trademarks of Lutron Electronics o., Inc. Job ame: SPEIFIATI SUBMITTAL Model umbers: Job umber: