Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Similar documents
Analog Isolation Amplifiers

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Components Signal Conditioning For Your Computer Instruments Standard Models

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Modular Smart Interfaces

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Analog Isolation Amplifiers

Model Channels Input type Sample rate Resolution

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SCXI 8-Channel Isolated Analog Input Modules

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Advanced Test Equipment Rentals ATEC (2832)

USB-2404-UI Specifications

ADAM 4000/4100 Series

Analog Signal Conditioning Accessories

Low Noise Variable Gain Low Frequency Voltage Amplifier

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Q.raxx A slimline RS / EC

Correlation of Voltage and Temperature Measurement

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

CONTA-ELECTRONICS. Converter Units

Variable Gain Low Frequency Voltage Amplifier

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

KMT - Kraus Messtechnik GmbH

Q.raxx A101-8 slimline RS / EC

Zero Drift, Unidirectional Current Shunt Monitor AD8219

Series Modules. Overview. Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2. ANALOG Modules Channels

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Q.raxx A slimline RS / EC Universal Measurement System

Series GLET Accessory for dataloggers series GL in modular enclosure

High-precision process calibrator Model CED7000

DIN Thermocouple Conditioner MODEL 5M14(V)

KMT - Kraus Messtechnik GmbH

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Variable-Gain High Speed Current Amplifier

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance.

High Resolution, Zero-Drift Current Shunt Monitor AD8217

Low Noise Variable Gain Low Frequency Voltage Amplifier

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Analog I/O Module Summary

Telemetrie-Messtechnik Schnorrenberg

NEW! AOIP FD5 Advanced Digital Data Logger

DIGEM f 96 x 48 EK. Applications. Description

IsoAmp 11000/ The Universal Isolation Amplifier.

User Manual CTP4/8/16

Temperature Transmitters - Head Mounted

AD8218 REVISION HISTORY

Multifunction Calibrator - Model 8080

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Process displays For standard signals, temperature, resistance measurement

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Variable Gain Sub Femto Ampere Current Amplifier

IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals.

Additel 875 Series Dry Well Calibrators

Temperature Transmitters - DIN Rail Mounted

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

VXI-TB CHANNEL ISOTHERMAL TERMINAL BLOCK

2750 Integra Mainframes

CALYS 150. Advanced documenting multifunction calibrator thermometer

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Assembly. Front view. Parametrization interface. Power Bus

PACSystems* RX3i IC695ALG600

LOW NOISE / LOW DRIFT DIFFERENTIAL AMPLIFIER SP 1 004

Transducer for Measurement Bridges SCM90, SIGS15

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

ULTRASTAB I U Precision

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

Telemetrie-Messtechnik Schnorrenberg

Low Noise Variable Gain Low Frequency Voltage Amplifier

World-Class Accuracy & Measurement Range (40 Conventional Models)

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

PACSystems* RX3i IC695ALG600-DD

OPERATING INSTRUCTIONS NI Channel, 24-Bit, Universal Analog Input Module

MODEL: R30US4. Remote I/O R30 Series

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Specifications Test Conditions Vs = ± 15 V, Ta = 25 C Gain Gain Values 40, 60, 80, 100 db indicated by four LEDs Gain Accuracy ± 0.1 % (between settin

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

5500A. Multi-Product Calibrator. Extended Specifications 2005

General Specifications

ONE CALIBRATOR ONLY MAIN FEATURES:

5520A. Multi-Product Calibrator. Extended Specifications 2005

Model ½-Digit Multimeter Datasheet

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:

Temperature measurement TMD 832 head transmitter

MODEL SR445A. 350 MHz PREAMPLIFIER

Transcription:

Selection Guide PAD Series Modules Multi channel Low bandwidth - for static signals Isolation Digital output (RS-485) Exchangeable For DEWETRON systems with built-in DAQ rack Module # CH Input type Ranges V PAD-CB8-x-M Miniature thermocouple connection block for PAD-CB8-x-P2 Standard thermocouple connection block for PAD- TH8-P modules PAD-CB8-RTD Connect up to 8 RTD sensors (or resistors) to Bandwidth (BW), Filters (FILT) PAD-OPT1 Screw terminal adapter including cold junction compensation (CJC) for Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: ISO: current with external shunt ±20 ma FILT: 1 / 4 / 8 values averaging OP: 150 V DC Temperature and ohmic measurement PAD-TH8-P 8 Voltage ±15, ±50, ±100, ±150 mv, BW: ISO: -150 mv to +1.5 V, FILT: 1 / 4 / 8 values OP: 15 V DC Thermocouple Thermocouple type J, K and T averaging PAD-TH8-P + CB8-RTD 8 Thermoresistors Pt100, Pt200, Pt500, Pt1000, BW: ISO: Pt2000, Ni120 FILT: 1 / 4 / 8 values OP: 15 V DC Resistors up to 2 kohm averaging Digital out, analog out PAD-DO7 7 Digital output Relay outputs (dry contacts) - ISO: 300 V DC max load: 0.5 A @ 60 V AC, 1 A @ 24 V DC PAD-CB8-x BNC or banana sockets for easy signal connection to PAD-V8-P modules 1

PAD Series Modules PAD-V8-P A/D conversion Bandwidth: 8 channel voltage module 8 internal 24 bit A/D converters 25-pin SUB-D socket Module specifications (for revision 6.00 or higher) PAD-V8-P Input channels Input signals Voltage ±100 mv, ±150 mv, ±500 mv, ±1 V, ±2.5 V, ±5 V, ±10 V, ±50 V, -0.15 to +1.5 V Current With external shunt resistor Resolution 10 µv for all ranges Sampling rate Max. 12 Hz per channel Readout speed Typ. 80 ch/sec.* DC accuracy ±0.03 % of reading ±900 µv Max. gain drift 20 ppm / C Max. offset drift 20 ppm of range / C Bandwidth (-3 db) (±1.5 db @ f0) (channel to channel and input to output) Overvoltage protection 150 V DC Common mode voltage / 250 V AC @ 50 Hz NMR 120 db @ 50/60 Hz CMRR 140 db @ DC, 120 db @ 50 Hz Interface speed 9600 bps (2400 to 115200) Power supply voltage ±9 V DC Typical 0.6 W *) Depending on system and number of channels 2 www.dewetron.com

PAD-TH8-P A/D conversion Bandwidth: 8 channel thermocouple and RTD module Thermocouple: requires PAD-CB8-x breakout box RTD:requires PDA-CB8-RTD breakout box 8 internal 24 bit A/D converters 25-pin SUB-D socket Module specifications (for revision 6.00 or higher) Input channels Input voltage Input resistance PAD-TH8-P ±1.5 V 1.4 MΩ Gain linearity 0.001% Bandwidth Resolution Max. gain drift Max. offset drift Typical noise 2 µv DC accuracy Sampling rate Readout speed Overvoltage protection NMR (50/60 Hz) CMRR (50/60 Hz) 1 µv (24-bit) 25 ppm / C 25 ppm of range / C Better ±0.05 % ±200 µv (typ. ±0.03 % F.S. ±20 µv) Max. 12 Hz per channel Typ. 80 ch/sec.* (channel to chassis ground) 100 V DC (channel to channel) 15 V DC 120 db 130 db Interface speed 9600 bps (2400 to 115200) Power supply voltage ±9 V DC *) Depending on system and number of channels Typical 0.6 W 3

PAD Series Modules PAD-CB8-RTD 8 channel RTD connector block for PAD-TH8-P 8 RTD channels, type Pt100, Pt200, Pt500, Ni120,... Sensor supply: galvanically isolated to PAD-TH8-P module Specifications PAD-CB8-RTD Input channels 8 RTDs Constant current 1250 µa (CB8-RTD-S3: 250 µa) Constant current drift 5 ppm/ K Connection types 2-, 3- or 4-wire Standard input ranges Resistor 0 to 999,99 Ohm, Pt100 a = 0.00385; Pt100 a = 0.003916; Pt200; Pt500; Ni120 CB8-RTD-S3 Resistor 0 to 999,99 Ohm, Pt100 a = 0.00385; Pt100 a = 0.003916; Pt200; Pt500; Pt1000; Pt2000 Accuracy Pt100 a = 0.00385 Pt100 a = 0.003916 Pt200 a = 0.00385 Pt500 a = 0.00385 ±0.25 C @ -200 to 100 C ±0.25 C @ -200 to 100 C ±0.25 C @ -200 to 100 C ±0.25 C @ -200 to 100 C ±0.4 C @ 100 to 400 C ±0.4 C @ 100 to 400 C ±0.4 C @ 100 to 400 C ±0.4 C @ 100 to 250 C ±0.8 C @ 400 to 800 C ±0.8 C @ 400 to 800 C ±0.5 C @ 400 to 630 C Pt1000 a = 0.00385 Pt2000 a = 0.00385 Ni120 ±0.25 C @ -200 to 100 C ±0.25 C @ -200 to 100 C ±0.3 C @ -80 to 100 C ±0.4 C @ 100 to 400 C ±0.4 C @ 100 to 400 C ±0.6 C @ 100 to 260 C ±0.8 C @ 400 to 600 C ±0.8 C @ 400 to 600 C Typical noise 0.01 C Operating temperature -25 to +80 C Cabel length 2m (up to 12 m on request) Dimensions (WxDxH) approx. 196 x 57 x 32.2 mm (7.7 x 2.2 x 1.3 in.) PAD-CB8-x-M and PAD-CB8-x-P2 Thermocouple type: 8 channel thermocouple connector block for PAD-TH8-P 8 thermocouple versions for K, J, T Specifications PAD-CB8-x-P2 and PAD-CB8-x-M Input channels 8 isolated thermocouple input channels Accuracy Thermocouple type J: Thermocouple type K: Thermocouple type T: ±1.0 C @ -200 to -100 C ±1.0 C @ -200 to -25 C ±1.0 C @ -200 to -150 C ±0.3 C @ -100 to 150 C ±0.4 C @ -25 to 120 C ±0.4 C @ -150 to 400 C ±0.4 C @ 150 to 400 C ±0.6 C @ 120 to 400 C ±1 C @ 400 to 1200 C ±1 C @ 400 to 1372 C Thermocouple type E, R, S, N, C or other types on request Typical noise ±0.1 C @ sampling; no average CJC Internal Operating temperature -25 to +80 C (better on request) Cable length 2 m (up to 12 m on request) 4 www.dewetron.com

PAD-DO7 7 channel relay output module Output channels: 7 relay output channels 300 V RMS 25-pin SUB-D connector Module specifications PAD-DO7 Number of channels 7 relay output channels Relay type Form A relay SPST N.O. with dry contacts Max. load 0.5 A (60 V AC ) 1 A (24 V DC ) 300 V RMS Relay on time Typical 5 ms Interface speed 9600 bps Power supply voltage +12 V DC Typical 1.0 W DEWETRON GmbH Parkring 4 8074 Grambach AUSTRIA Tel: 0043 316 30700 Fax: 0043 316 3070 90 info@dewetron.com DE-B100401E All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. DEWETRON GmbH 11/2016 5