Mobile demagnetizer MM DM-P / -PC (large objects, pipes, bars, stock)

Similar documents
Product Program High-Performance Demagnetizers

Demagnetizing. Clamping Chucks. Clamping Plates. Lifting Magnets. Holding Magnets. Demagnetizing. Units. Control Electronics. Non-Ferrous Separators

Workplace safety for demagnetizer operators

RECOMMENDED & DISTRIBUTED BY. Inverter Series PORTABLE WELDING SOLUTIONS

RECOMMENDED & DISTRIBUTED BY. Inverter Series PORTABLE WELDING SOLUTIONS

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

The latest version offers all the features already available in the IPoD series 8232 to 8238 and 8427 as well as providing several exclusive

Novel Demagnetization Method after Magnetic Particle Testing

Inverter Series PORTABLE WELDING SOLUTIONS

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

LV Compensation & Filtering Products

AC/DC Submerged Arc Welding

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Product Specification of BURY Speaker

Inverter Series PORTABLE WELDING SOLUTIONS

Exercises in Welding Process and Equipment --- Part 3: Power-source and Equipment ---

Technical Specification

Bevelling made easy. SKF AutoCUT EKF EKF EKF EDGE PROCESSING MACHINES

Pulse welding machine Intuitive operation

Flexibility and efficiency on high accuracy machining

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

MC-370CE - Soco Cold Saw, Includes Stand 100 x 100mm Rectangle Capacity Dual Speed 22 / 44rpm & Self Centring Vice & CE Approved Guarding

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

FERROMASTER. Instruction Manual

Hybrid & Electric Mobility Solutions Electric Vehicle Contactors

EN 1090-certified Pulse welding machine Powerful

Instruction Manual Veritest

Chicago Electric MIG B Gun Install

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

CAMTO. Arc detecting relay. system. January Revised August D D1200

Advanced electromagnetism and electromagnetic induction

Power supply CP-D 24/4.2 Primary switch mode power supply

MAGNETC ARC OSCILLATOR MODEL : HTW-05-MG I HTW-05-MG II

Lincoln Electric EMEAR ASPECT 300. Industrial TIG AC/DC Welder K BK rev02

High precision measurement system for current and voltage IHC-A/B-RM01/03

Three-Phase Transformer Demagnetizer DEM60

Three-Phase Winding Ohmmeter TWA25K

PROFILE 500. Halogen profile-spot

TM1600. Circuit Breaker Analyzer System

Electricity Fundamentals Training System

MAGNETIC FIELD MEASURING

AMH-DC-TB-S SOFT MAGNETIC MATERIALS: RINGS, BARS, STRIPS

Placement Paper For Electrical

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

SubArc Digital Series

Quadrupole Power Supply Unit QPS400-3

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

HTC Technical Manual

MTE training MTE Corporation

Preface...x Chapter 1 Electrical Fundamentals

AC/DC Current Probe CT6844/CT6845/CT6846

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

MASTER TIG-250AC/250MV

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Reliably switch high powers and specific loads Our TERMSERIES and D-SERIES products are proven in practice Let s connect.

Capacitor Switching Contactors

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

PROMIG-250SYN/250SYN Pulse

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

Surge Generator for MIL-STD 1275

Introduction. A closed loop of wire is not an electrical circuit, a circuit requires

Submerged Arc Welding Equipment

BALANCED DRIVE. Line of speaker units designed with optimized motor symmetry. The Wavecor Balanced Drive Technology

NBU-1012 Square pulse flashlamp driver User Manual

Magnetic induction with Cobra3

proton beam onto the screen. The design specifications are listed in Table 1.

Practical Tricks with Transformers. Larry Weinstein K0NA

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

Exercise 3: EXERCISE OBJECTIVE

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

DC CIRCUITS Part I of III Parts. Part II installation. Part III troubleshooting

SMD Pulse Transformer for Ethernet Applications. The New Reference LAN Pulse Transformer

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

DETECTING SHORTED TURNS

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Laboratory no. 3 FLUORESCENT LAMPS FITTINGS

Deltaweld 350 Systems

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

Process: DC TIG (GTAW) AC TIG (GTAW) Input Power: 230V, 1-Phase Amperage Range: A Rated Output at40 C (104 F): Maintenance and Repair

WIND MONITOR ANEMO / WIND VANE YOUNG ALPINE

Power supply CP-D 24/1.3

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

2 PDT Coil supply. Contacts rated at. Contact rating per pole and load type. Load Current in 100,000 cycles 100,000 cycles

FG2 TWO-CHANNEL DETECTOR

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Electro-Magnetic Flowmeters COPA-XE

SubArc Digital Series

PCT200 SERIES CT/PT TEST SYSTEM USER MANUAL

Wire feeding systems for welding applications

The NEW itig II Winding and Motor Analyzer A revolution in automated, safe, and comprehensive high and low voltage tests all in a lightweight

Welding Transformer: Principle, Requirement and Types

Laboratory Exercise 6 THE OSCILLOSCOPE

Thyristorised Automatic Power Factor

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.

Transcription:

Mobile demagnetizer MM DM-P / -PC (large objects, pipes, bars, stock) -Description -Specification -Technology -Application examples www.maurermagnetic.ch 09.06.2015 page 1/10

cable coils stationary coils Description of the modular mobile demagnetizer A8/10-1.4 K8/10-30 A5/6-1.6 MM DM-PC CT-UDM K5/6-15 MM DM-P K10/2.5-15 www.maurermagnetic.ch 09.06.2015 page 2/10

Power module specifications Type MM DM-P MM DM-PC MM DM Available performance MM DM 110, DM 140, DM 200, DM 240 MM DM36...400 Maximum current 110 240 A 36...400A Exterior dimensions W x H x D 550 x 1060 x1150 mm Variable (on request) Mobility Power module cabinet movable on 4 rollers - Line power supply 3 x 380 480 VAC 50 / 60 Hz, 63A-CEE fuse 3 x 380 480 VAC 50 / 60 Hz, variable fuse Operational interface Control switches PC with touch screen Variable (on request) Operation features No. of demagnetization programs Pulse activation Manual switches Indicator lamps 10 power levels Pulse activation Enhanced parameters Indicator lamps Variable (on request) 4 Unlimited Variable (on request) Offset function no yes Variable (on request) www.maurermagnetic.ch 09.06.2015 page 3/10

Coil module specifications Type K8/10-30 A8/10-1.6 K5/6-15 A5/6-1.4 K10/2.5-15 Flexible cable coils Weight ~40kg, length ~30m, may be interconnected several times Adapter cable for cable type K8/10-30 (necessary) Weight ~5kg, length ~15m, may be interconnected several times Adapter cable for cable type K5/6-15 (necessary) Weight ~3kg, length ~15m, (no adapter needed) CT-UDM Stationary universal coils Type CT6-UDM CT7-UDM CT8-UDM Active opening WxH 400x400mm 550x550mm 750x550mm Max. field strength Up to 100kA/m Up to 75kA/m Up to 75kA/m www.maurermagnetic.ch 09.06.2015 page 4/10

Technology: Demagnetization through decaying alternating magnetic field Goal: the best possible distribution of the domain magnetization direction in the demagnetized material Max. field strength [ka/m] Frequency [Hz] Effective range [LxWxH, m 3 ] Field homogeneity Decay precision Reversal of hard magnetic domains, penetration depth Penetration depth Full magnetic fluxing of material Uniform effect in the material Low decrement and best field symmetry at the end of the process for the best possible domain distribution Max. field strength decrement Frequency Field symmetry www.maurermagnetic.ch 09.06.2015 page 5/10

Demagnetization Technologies Technology Coil module Field strength Field reduction through increasing distance (continuous process) Pulse without energy feeding (capacitor discharge) Coil Plate / Yoke Coil Plate / Yoke Effective range Field homogeneity Decay precision Pulse with energy feeding (MaurerDegaussing) Coil Plate / Yoke www.maurermagnetic.ch 09.06.2015 page 6/10

Key arguments True demagnetization Demagnetization by high power AC sine field pulse with energy feeding No re-magnetization of the steel Demagnetization of subcomponents prior to assembly and/or welding Quick demagnetization Short demagnetization pulse duration of ~10 seconds Application of the lay on method for the cable coils (no winding is needed Allows demagnetization of large steel amounts within a short time Easy to use Triggering of the pulse by push the button Standard procedure leads to consistent results A degaussing specialist is not needed www.maurermagnetic.ch 09.06.2015 page 7/10

Application example: Demagnetization of large surface objects Reasons: Residual magnetism limits impaired welding process (magnetic arc blow) Elimination or reduction of magnetocorrosion Solution: MM DM200-P or -PC 2x K8/10-30 + 1x A8/10-1.4 Procedure according to: White Paper: Demagnetization of large surface objects before welding lay on and pulse coil type: 2x K8/10-30 www.maurermagnetic.ch 09.06.2015 page 8/10

Application example: Demagnetization of pipes or bars in a stock coil type: 2x K5/6-15 wound cable coil Typical reason: Residual magnetism limits Solution: MM DM200-P or -PC 2x K5/6-15 + 1x A5/6-1.6 optional 2x K8/10-30 + 1x A8/10-1.4 coil type: 1x K8/10-30 www.maurermagnetic.ch 09.06.2015 page 9/10

Application example: Demagnetization of steel plates lay on and pulse Typical reason: Residual magnetism limits Solution: MM DM200-P or -PC 2x K8/10-30 + 1x A8/10-1.4 optional 2x K5/6-15 + 1x A5/6-1.6 coil type: 2x K8/10-30 www.maurermagnetic.ch 09.06.2015 page 10/10