NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

Similar documents
PKZ 2 Manual Motor Protectors Technical Data

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILM40(RDC24) Article No.:

Breakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories

Type: DILEM 10 G(24VDC) Article No.:

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

3 - Protection components Circuit-breakers

Characteristics 5 TeSys k contactors and reversing contactors

Page 13-2 Page Page 13-7

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Easy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Technical features table for miniature circuit-breakers SH 200 Series

Type CP-S, CP-C & CP-A Switch mode

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Capacitor Switching Contactors

Control module CP-A CM

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

XT IEC Power Control Miniature Controls

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Contactors and Contactor Assemblies

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Ratings for Switching AC Motors AC-2, AC-3, AC / /

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

2010 CA Z-EN

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Technical Data Accessories MCCBs Ex9M.

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Motor Protection Circuit Breaker Series 8146/5-V27

DILK50-10(230V50HZ,240V60HZ) Catalog No Eaton Catalog No. XTCC050D10F. Application Contactors for power factor correction. mm 1 x (2.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

11/0 IZM circuit-breakers, IN switch-disconnectors

For Immediate Delivery call KMParts.com at (866)

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

AT4 Position Switches Complete Units

NS..S contactor relays - with spring terminals AC operated

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Modeion MOULDED CASE CIRCUIT BREAKERS BL1000S

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

For Immediate Delivery call KMParts.com at (866)

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

Three-phase monitoring relays CM-PFE and CM-PFE.2

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Installation / Monitoring Technique

E-STOP relays, safety gate monitors

Three-phase monitoring relay CM-PFS

Moeller Electric Corporation

New Products Catalogue 2009 Safety Relays ESR5

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Three-phase monitoring relay CM-PVE

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

190S A N D 2 C A16 C TE

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Protection components

Controls Contactors and Contactor Assemblies Special Applications

EN 50178, IEC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

CP-T range Product group picture

Uncompromising Quality: More Reliability for Single-Phase and Three-Phase Supply Networks

L-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Three-phase monitoring relay CM-PBE

technical information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Transcription:

Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000 8000 Rated operational voltage U e 50/60 Hz V 500 690 690 Rated short-circuit making capacity I cm ka 220 275 275 Short-circuit interrupting rating I cn I cu IEC/EN 60 947 test cycle O-t-CO I cs IEC/EN 60 947 test cycle O-t-CO-t-CO 220 240 V 50/60 Hz I cu ka 100 125 125 I cs ka 75 95 95 380 400/415 V 50/60 Hz I cu ka 100/65 100/90 100/90 I cs ka 50/33 50/45 50/45 cos ϕ 0,25 0,25 0,25 500 V 50/60 Hz I cu ka 20 35 35 cos ϕ 0,3 0,25 0,25 I cs ka 10 18 18 cos ϕ 0,5 0,3 0,3 660/690 V 50/60 Hz I cu ka 20 20 cos ϕ 0,3 0,3 I cs ka 5 5 cos ϕ 0,7 0,7 DC voltage T 15 ms 110 V DC ka 30 30 30 250 V DC ka 20 20 20 440 V DC ka 12 12 12 NZMH6-.../ZM6A...-

09/099 NZM9-.../ZM9A-...- NZMH9-.../ZM9A-...- 250 250 1000 8000 8000 690 690 73 220 NZM12-.../ZM(A)-...- 2) General technical data Standards and specifications UL 489, CSA 22.2 No. 5.1 IEC/EN 60 947-2, VDE 0660 Climatic proofing Damp heat, constant to IEC 60 068-2 3 Damp heat, cyclical to IEC 60 068-2 30 Ambient temperature, min./max. C open 25/+55 (lower temperatures enclosed 25/+40 on request) Shock resistance 25 g (shock duration 20 ms) Leistungsschalter, Lasttrennschalter bis 1600 A 35 100 18 75 0,3 0,2 35 100/90 18 75/68 0,3 0,2 25 65 13 33 0,3 0,25 10 28 0,5 0,25 10 14 0,5 0,3 25 35 20 30 15 25 Dimension page 09/109 Weights page 14/020 Mounting position 30 Notes 1) Type NZMH4-...-C thermal magnetic devices (16-80 A) are rated as circuit breakers per IEC/EN 60 947-2 only. See page 09/... for more information 2) Type NZM12-...- circuit breakers are UL/CSA only. Consult Moeller Electric for IEC/EN rated versions.

Circuit Breakers, 09/100 Molded case circuit breakers NZMH4-...- C 1) NZM6B-.../ ZM6A-...- NZMH6-.../ ZM6A-...- NZM9-.../ ZM9A-...- NZMH9-.../ ZM9A-...- NZM12-.../ ZM(A)-...- 2) Frame size A 80 125 125 250 250 1000 Overload trips Bimetal type (directly heated) A 4-80 15-125 15-125 63-250 63-250 Solid state type A 300-1000 Temperature compensation, residual error in the range 25/ +55 C (reference 20 C) %/K 0.3 0.7 0.7 0.3 0.3 Undervoltage trips Pull-in voltage range % U s 85 110 85 110 85 110 85 110 85 110 85 110 Dropout voltage range % U s 70 35 70 35 70 35 70 35 70 35 70 35 Minimum command time ms 10 15 10 15 10 15 10 15 10 15 10 15 Inrush rating AC VA 6.5 6.5 6.5 40 40 100 Sealing AC VA 3.5 3.5 3.5 7 7 12 Inrush rating DC W 2.8 2.8 2.8 1.9 1.9 160 Sealing DC W 2.8 2.8 2.8 1.9 1.9 3.6 Shunt trips Pull-in voltage range % U s 70 110 70 110 70 110 70 110 70 110 70 110 Minimum command time ms 10 15 10 15 10 15 10 15 10 15 10 15 Inrush rating AC (50 Hz) VA 50 50 50 150 150 350 Sealing AC VA 15 15 20 Inrush rating DC (intermittent duty operation) W 40 40 40 120 120 200 Switching times Tripping in the event of a short-circuit Minimum command time ms 2 3 3 4 4 6 Opening delay ms 0.3 0.3 0.3 6 0.3 12 Total opening delay ms 5 6 6 20 6 25 Opening delay with: Shunt trips (100 % of rated coil voltage) ms 10 20 10 20 10 20 10 20 10 20 15 25 Undervoltage trips ms 15 20 15 20 15 20 15 20 15 20 20 25 NHI, VHI, AHI, RHI auxiliary contacts 3) IEC/EN 60 947 ratings Rated operational current I e AC-15 115 V 50 Hz A 6 6 (1) 6 (1) 6 (1) 6 (1) 6 230 V 50 Hz A 6 6 (1) 6 (1) 6 (1) 6 (1) 6 400 V 50 Hz A 4 4 (1) 4 (1) 4 (1) 4 (1) 4 DC-13 (L/R 200 ms) 24 V DC A 1 1 (1) 1 (1) 1 (1) 1 (1) 1 60 V DC A 0.8 0.8 (0.4) 0.8 (0.4) 0.8 (0.4) 0.8 (0.4) 0.8 110 V DC A 0.7 0.7 (0.2) 0.7 (0.2) 0.7 (0.2) 0.7 (0.2) 0.7 220 V DC A 0.3 0.3 (0.1) 0.3 (0.1) 0.3 (0.1) 0.3 (0.1) 0.3 Lifespan, electrical to AC-15 ops. 20000 20000 20000 20000 20000 20000 to DC-13 ops. 5000 5000 5000 7500 7500 2500 Short-circuit rating without welding (contacts closed) Fuseless PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 Fuses A gl 10 10 10 10 10 10 UL/CSA Pilot Duty Ratings Type NHI Pilot Duty A600/P600 A600/P600 A600/P600 A600/P600 A600/P600 A600 Type VHI, AHI, RHI C300 C300 C300 C300 A600 Notes: 1) Type NZMH4-...-C thermal-magnetic devices (16-80A) are rated as circuit breaker per IEC/EN 60 947-2 only. See page 09/053 for further information 2) Type NZM12-...- circuit breakers are UL/CSA only. Consult Moeller Electric for IEC/EN rated version. 3) For IEC/EN 60 947 ratings, values which appear in brackets apply to VHI, AHI, and RHI contacts. Otherwise values apply to all contacts.

09/101 UL/CSA Motor disconnect switches with IEC/EN Molded case circuit breakers 3 pole NZMH4-...-C NZM(H)6(B)/ZM6-...-C NZM(H)9/ZM9-...-C Frame size A 80 125 250 Motor disconnect switches with General technical data page 09/098 page 09/098 page 09/098 IEC/EN 60 947-2 circuit breaker ratings page 09/098 page 09/098 page 09/098 UL 508 / CSA 22.2 No.14 motor disconnect switches Adjustable range of thermal overload trips A 4-80 15-125 63-250 HP ratings HP page 09/053 page 09/062 page 09/072 Auxiliary contacts, voltage trips page 09/100 page 09/100 page 09/100 Circuit Breakers, UL/CSA Motor disconnect switches without IEC/EN switch-disconnectors 3 pole N6-...-C N9-...-C N12-...-C N12-...- Frame size A 150 150 1200 Motor disconnect switches without General technical data page 09/098 page 09/098 page 09/098 IEC/EN 60 947-3 switch disconnector ratings Rated impulse withstand voltage V 8000 8000 8000 Rated short-time withstand current I cw (1s current) ka 3 7 20 Lifespan, mechanical ops. 20000 30000 15000 Max. operating frequency ops./h 60 60 60 Lifespan, electrical AC-1 ops x 10 3 10 10 10 AC-2, AC-3 ops x 10 3 5 5 5 DC-2, DC-5 ops x 10 3 1 0.5 0.5 UL/508 / CSA 22.2 No. 14 motor disconnect switches HP ratings page 09/053 page 09/062 page 09/072 Auxiliary contacts, voltage trips page 09/100 page 09/100 page 09/100 UL 489 molded case switches page 09/081 Mounting position 1)

09/102 Circuit Breakers, Type NZMH4-...-OBI-C NZMH4-...-C NZM(H)6(B)-.../ZM6(A)-...-(C) NZM(H)6(B)-.../ZM6-...-OBI-C current A 18 80 100 125 AWG 14... 3 AWG 14... 3 AWG 14... 1/0, up to 90A, 60/75 C cable 100A, 60 C cable Nm 4 4 10 15 NZM(H)6(B)-160/ZM6(A)-125-(C) NZM(H)6(B)-160/ZM6-125-OBI-(C) AWG 4... 3/0, 125A, 60 C cable Type NZM(H)9-.../ZM9(A)-...-(C) NZM(H)9-.../ZM9-...-OBI-C NZM12-.../ZM12(V)(A)-...- current A 250 800 1000 AWG 8... Kcmil 300 Kcmil 250-600 2 conductors: AWG 3/0... 3 conductors: Kcmil 250... 400 AWG 2... Nm 40 50 50 Type N6-...-C N9-...-C N12-...-C current A 100 150 250 800 1000 1200 AWG 14... 1/0 75 C cable AWG 4... 3/0 75 C cable AWG 8... Kcmil 300 Kcmil 250-600 2 conductors: AWG 3/0... 3 conductors: Kcmil 250-400 AWG 2... Nm 10 15 40 50 50 50 AWG 2... Notes: All devices shown above except type NZM12-... are dual rated UL/CSA and IEC/EN. Consult Moeller Electric for IEC/EN conductor cross information.