Shunt active filter algorithms for a three phase system fed to adjustable speed drive

Similar documents
Simulation Study of PWM Techniques for Voltage Source Converters

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Power Quality improvement of a three phase four wire system using UPQC

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Application of Fuzzy Logic Controller in Shunt Active Power Filter

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Neural Network Controlled Hybrid Active Power Filter with Distorted Mains for PMSM Drive

2020 P a g e. Figure.2: Line diagram of series active power filter.

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

Literature Review for Shunt Active Power Filters

Selective Harmonic Elimination Using Three Phase Shunt Active Power Filter

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

DESIGN AND IMPLEMENTATION OF THREE PHASE SHUNT APF CURRENT CONTROLLER WITH ANN TECHNIQUE

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A Novel Fuzzy Variable-Band Hysteresis Current Controller For Shunt Active Power Filters

Chapter 2 Shunt Active Power Filter

Indirect Current Control of LCL Based Shunt Active Power Filter

Power Quality Improvement using Shunt Passive Filter

Power Quality Improvement in Fourteen Bus System using UPQC

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

Three Phase Active Power Filter Based on Current Controlled Voltage Source Inverter

ACTIVE compensation of harmonics, reactive power and

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Performance Analysis of UPQC for Non-Linear Load by Using MATLAB

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

IMPLEMENTATION OF NEURAL NETWORK IN ENERGY SAVING OF INDUCTION MOTOR DRIVES WITH INDIRECT VECTOR CONTROL

Active Power Filters: A Comparative Analysis of Current Control Techniques for Four-Leg Full-Bridge Voltage Source Inverters

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Delhi Technological University (formerly DCE) Delhi-42, India

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC

An Adjustable-Speed PFC Bridgeless Single Switch SEPIC Converter-Fed BLDC Motor

STATCOM BASED ON REDUCTION OF PQ ISSUES IN MICRO GRID APPLICATION SYSTEMS

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

ISSN Vol.03,Issue.42 November-2014, Pages:

CURRENT HARMONICS REDUCTION IN 3 PHASES 4 WIRE SYSTEM USING HYBRID FILTERS R.Saravanakumar 1#, S.Amritha 2#

Improving the Power Quality by Four Leg VSI

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

Control Strategy for a cross phase connected and a conventional UPQC

ABSTRACT I. INTRODUCTION

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

Harmonics Reduction using 4-Leg Shunt Active Power Filters

645 P a g e. the quantity of compensate current needed accordingly. Fig. 1. Active powers filter with load current detection.

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

SCIENCE & TECHNOLOGY

Improvement of Power Quality by Using 28-Pulse AC-DC Converter

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

HARMONIC contamination, due to the increment of nonlinear

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

International Journal of Advance Research in Engineering, Science & Technology

Power Quality Enhancement in Distribution System using ANN based DSTATCOM

Transcription:

Shunt active filter algorithms for a three phase system fed to adjustable speed drive Sujatha.CH(Assoc.prof) Department of Electrical and Electronic Engineering, Gudlavalleru Engineering College, Gudlavalleru, (A.P.), India ksujathasagar@gmail.com Sravanthi.Kusam(M.tech) Power electronics & Electrical Drives, Department of Electrical and Electronic Engineering, Gudlavalleru Engineering College, Gudlavalleru, (A.P.), India Sravanthi.kusam@gmail.com Dr. K.Chandra shekar Department of Electrical and Electronic Engineering, Rvr& jc college,anu Guntur (A.P) Abstract This paper presents the simulation of Shunt Active Power filter by using two different control schemes, Indirect current control technique and Synchronous detection technique by using ANN. These two control techniques are working under both balanced and unbalanced three phase voltage source conditions and it is feeding to a adjustable speed drive the torque speed characteristics of a motor is presented. Indirect current control technique is implemented under dynamic load condition and load balanced condition. The equal current distribution method of synchronous detection theory is used here to calculate the three phase compensating currents to be provided by the active filter. For calculating sequence currents neural network is used. Neural network is used for estimation of distorted waves, delay less harmonic filtering. Keywords -- Power Quality, Shunt active filter, indirect current control, Synchronous detection technique using ANN. 1. Introduction The wide use of non-linear loads such as uninterrupted power supplies (UPS), adjustable speed drives (ASD), furnaces, and single phase computer power supplies etc cause power quality problems such as harmonic currents, poor power factor and voltage sag/swell increase in reactive power. There are several shunt active filtering algorithms developed. This paper presents the latest advanced techniques indirect current control and Synchronous detection technique of the Active filter; the three-phase reference supply currents are obtained using a closed loop PI controller. A Hysteresis PWM current controller is employed over the reference and sensed supply currents to generate gating pulses of IGBT s of the Active filter. The control algorithm used in this is synchronous detection theory based on Equal current distribution, but this theory, in its original form, will not work under the condition of voltage distortion. This problem can be eliminated by sensing the source/load voltages/currents from which fundamental reference currents can be deduced. By using two control methods the THD values are compared and torque and speed variations for an adjustable speed drive with balanced and unbalanced voltage source are presented here. In this paper, simulation results of indirect current control technique and Synchronous detection technique are present. 2. Indirect current control Sujatha.CH et al. / International Journal of Engineering Science and Technology (IJEST) The fig: 1 shows the basic control scheme of the AF using indirect current control. Three-phase voltages at PCC along with dc bus voltage of the AF are used for implementation of control scheme. ISSN : 0975-5462 Vol. 3 No.10 October 2011 7577

usa usb usc Fig: 1 Control algorithm for indirect current control Comparison of Average value of DC bus voltage ( v dc ) and reference value of dc bus voltage ( results in a voltage error, which is fed to a PI controller as shown in figure. v * dc ) of the AF Here, proportional ( K ) and integral gains ( K ) are so chosen, such that a suitable DC bus voltage response is p achieved. The output of PI controller is taken as amplitude ( i I * sp ) of the reference supply currents. Now, Three-phase in-phase components of the reference supply currents are computed using their amplitude and in-phase unit current vectors derived in-phase with the supply voltages, and are given by... Where, and are in-phase unit current vectors and are derived as, / / / Where is the amplitude of supply voltage and it is computed as 2/3 / Hence from the above procedure, the three phase reference supply currents are computed. Now the three-phase reference supply currents and sensed supply currents are given as inputs to hysteresis current controller which generates gating signals for IGBT s of the AF. A. Implementation of hysteresis based current controller A Hysterisis current controller is used over reference supply currents (, and ) and sensed supply currents (, and ) to generate gating signals to the IGBT s used in the VSI bridge working as the AF. In response to gating pulses to the AF, eliminates harmonics, correct the power-factor at PCC to nearly unity and balances the unbalanced nonlinear load while maintaining a self-supporting dc bus of the AF. ISSN : 0975-5462 Vol. 3 No.10 October 2011 7578

The actual current in this forced to track the sine reference within the hysterisis band by back and forth (or bangbang) switching of the upper and lower switches. The inverter then essentially becomes a current source with peak to peak current ripple, which is controlled within the hysterisis band, which makes the source current to be sinusoidal. Hence the conditions for switching the devices are, Upper switch on: (i* - i) > HB. Lower switch on: (i* - i) < HB. The model of hysterisis controller, which is implemented in MATLAB for the current control purpose, is shown in below figure. The simulation model for the indirect current control is shown in fig: 2. Three phase supply is used under both balanced and unbalanced conditions. Unbalanced case fifth and seventh harmonics are high. Third harmonic cuntent was zero because of tree phase. The input inductor, Dc bus capacitor used in AF is choosen as L c =3.35mH, C dc = 1500µF. The torque speed a characteristic of adjustable speed drive is verified in with both balanced and unbalanced condition. Fig: 2 Simulation model for Indirect current control scheme in SIMULINK environment. 3. Synchronous detection technique Synchronous detection (SD) theory can work effectively under balanced as well as unbalanced source and load conditions because the compensating currents are calculated taking into account the magnitudes of per phase voltages. The synchronous detection method is applied to calculate compensating currents while the three phase source is feeding a highly non-linear load. The equal current distribution method of synchronous detection theory is used here to calculate the three phase compensating currents to be provided by the active filter. The following assumptions are made in calculating the three phase compensating currents using equal current distribution method of synchronous detection algorithm: (i) Voltage is not distorted; (ii) loss in the neutral line is negligible. The equal current synchronous detection method shows a better profile of source side line current after compensation. Assume the peak values of source currents are balanced after Compensation: Peak values of active current in each phase after compensation are ISSN : 0975-5462 Vol. 3 No.10 October 2011 7579

2, 2, 2 Where, and are real powers from each of the phases and, and are peak values of phase voltages in the three phases. From the above equations 2 2 2 Then The total average power By rearranging The reference active source currents are calculated as 2 2 2 Where The compensating current is obtained as In the control scheme, the fundamental positive sequence currents are being extracted. The reference currents can be obtained by subtracting the positive sequence current from the load current. The online extraction can be done by using Fourier integral or moving average filtering method. These methods involve a considerable delay for the calculation of Fourier coefficients. This delay can be reduced by the use of neural network filter. Applications of neural networks in power electronics are estimation of distorted waves, FFT analysis, on-line diagnostics, PWM techniques, delay less harmonic filtering, adaptive P-I close loop control etc. The control scheme applied in this work uses the neural network filter for online extraction of sequence currents. Artificial neural network (ANN) is an emerging technology that is advancing rapidly and having impact on many engineering applications. ISSN : 0975-5462 Vol. 3 No.10 October 2011 7580

Neural Network Structure The basic element needed for neural network is the neuron. The Structure of an artificial neuron is shown in fig: 3. Fig: 3 Multiple-input neuron In the neuron the input signals pass through synaptic weights and collect in the summing node before passing through a transfer function at the output. A bias signal can be added in the summing node. The interconnection of artificial neurons results in an artificial neural network (ANN). The ANN can generally be classified as feed forward and feedback types. In a feed forward network, the signals from neuron to neuron flow only in forward direction, where as in feedback network the signals flow in forward as well as backward direction. The examples of feed forward networks are perceptron, Adaline and Madaline and Back propagation network. The examples of feedback networks are Hopfield network and Boltzmann network. Extraction of negative sequence currents: For the extraction of sequence currents a three layer feedforward back propagation neural network is used. The general structure of a feed-forward back propagation network is shown below. The name "back propagation" comes from its characteristic training method. For extraction of sequence currents a three layer feed-forward back propagation neural network is used, with ten neurons in first layer (input layer) and ten neurons in second layer (hidden layer),three neurons in third layer (output layer). The transfer functions for all layers are purelin. Fig: 4 Feed-Forward back propagation network Training Data generation: For the extraction of sequence currents the required inputs are three phase currents, and the corresponding outputs. The required inputs and outputs are generated in MATLAB program. In the program the input Currents are initialized to zero, and incremented in steps. By taking one thousand samples in a cycle and arranging them in a vector of three rows, outputs also arranged in required vector size depends on the no of the outputs. The input vector size and output vector size must have same no of columns. The training data is generated for both balanced and unbalanced conditions. The number of the data required is depending on the network architecture and required error tolerance. Training the Network: The training of the network was done with MATLAB program. The training data required the number of epochs, error and min_gradient. The number of epochs depends on the error, and architecture of the network. First, the weights are initialized to random numbers. After training the first data the weights are adjusted to the required outputs. The training is done for both balanced and unbalanced conditions. After training, the network is simulated with trained inputs. If the network errors are with in the predefined range then the architecture is suitable, other wise the network architecture must be changed. After successful training the network can also give the required outputs with unknown inputs. After training the architecture is converted to simulink block. The generation of training data and training the neural network is done in using the neural network toolbox commands. The neural network structure is converted into simulink diagram using the command gensim, to interface with the other power system blocks. The fig:5 shows the 3 layers of the neural network and the fig:6 ISSN : 0975-5462 Vol. 3 No.10 October 2011 7581

shows the inside view of a layer. The fig:8 shows the no of the neurons of a layer. Simulation model for the synchronous detection technique is shown in fig: 7. Fig: 5 3Layer Feed-forward Neural Network Fig: 6 view of single Layer Fig: 7 Simulation Model for Shunt active Filter for proposed Synchronous detection method Fig: 8 View of Weights of the layer one ISSN : 0975-5462 Vol. 3 No.10 October 2011 7582

4. Simulation results The simulation results of the shunt active power filter is carried in MATLAB/Sim Power Systems environment. The simulation results are shown below. As can be seen from the figure, the non-linear load is a three-phase bridge rectifier feeding an adjustable speed drive. The simulation is done for various source and load conditions for providing harmonic compensation, load balancing and reactive power compensation. It can be clearly seen that by using Synchronous detection technique THD value is less compared to indirect current control technique. Fig: 9 Indirect current control wave forms under balanced three phase (a) Supply voltage& current (b) load current (c) filter current Fig: 10 Indirect current control wave forms under dynamic Load condition load is changing from 5KW to 10KW to 5KW. Three phase (a) supply voltage& current (b) Load current ISSN : 0975-5462 Vol. 3 No.10 October 2011 7583

Fig: 11 power factor is unity for supply voltage and current Fig: 12 speed & torque wave forms of adjustable speed drive for Indirect current control Fig: 13 Indirect control FFT analysis for supply current Fig: 14 Indirect control FFT analysis for load current & filter current ISSN : 0975-5462 Vol. 3 No.10 October 2011 7584

Fig: 15 Synchronous detection wave forms under balanced voltage. Three phase (a) supply voltage (b) supply current (c) Load current (d) output voltage (e) filter current Fig: 17 speed & torque wave forms of adjustable speed drive (Synchronous detection) Fig: 18 Synchronous detection wave forms under unbalanced voltage. Three phase (a) supply voltage (b) supply current (c) Load current (d) supply voltage after balancing (e) filter current Fig: 19 FFT analysis for supply current (Synchronous detection) ISSN : 0975-5462 Vol. 3 No.10 October 2011 7585

Fig: 20 FFT analysis for load current, filter current (Synchronous detection) Control techniques THD% Indirect current control Synchronous detection Table: 1 3.18 2.70 Table 1 shows that by using indirect current control the THD value is high compared to Synchronous detection technique. The harmonic content was eliminated in Synchronous detection technique is high. 5. Conclusion In this paper, indirect current control and Synchronous detection methods using equal current division technique have been applied to a shunt active power filter to compensate for reactive and harmonic currents under balanced and unbalanced source voltage conditions. The simulation has been carried out in MATLAB/SIMULINK environment and power factor is unity for supply voltage, current. 6. References [1] C.K.Duffey and R.P.Stratford, Update of Harmonic Standard IEEE-519 IEEE Recommended Practices and [2] Requirements for Harmonic control in Electric Power System, IEEE/IAS Transactions,Nov. /Dec.1989, pp.1025-1034. [3] Australian Standard (AS1359.31-1986), Rotating Electrical machines General Requirements, 1986. [4] uropean Standard IEC- 34-1(1983), Rotating Electrical machines, 1983. [5] Annette von Jouanne and Basudeb (Ben) Banerjee, Assessment of Voltage Unbalance, IEEE Transactions on power [6] delivery, Vol. 16, no. 4, Oct. 2001, pp. 782 780. [7] F.Z.Peng, D.J.Adams, Harmonic sources and filtering approaches-series/parallel, active/passive, and their combined [8] power filters, Conference Record of the IEEE 34th IAS Annual Meeting, Vol. 1, 3-7 Oct. 1999, pp. 448 455. [9] L.M.Tolbert, H.D.Hollis, and P.S Hale, "Survey of Harmonics Measurements in Electrical Distribution Systems, Industry [10] Applications conference, 1996. 31st IAS Annual Meeting, Conference record of the 1996 IEEE. [11] IEEE Task Force, Effects of harmonics on equipment, IEEE Transactions on Power Delivery, Vol. 8, Apr. 1993, pp. [12] 672-680. [13] IEEE Task Force, The effects of power system harmonics on power system equipment and loads, IEEE Transactions on [14] Power Apparatus and Systems, vol. 104, Sept. 1985, pp. 2555-2563. [15] Hugh Rudnick, Juan Dixon and Luis Moran, delivering clean and pure power, power energy magazine, IEEE, Vol. 1, [16] No. 5, Sep-Oct 2003, pp. 32-40. [17] Singh, K.Al-Haddad, A. Chandra, A review of active filters for power quality improvement, IEEE Transactions on [18] Industrial Electronics, Vol. 46, No. 5, Oct.1999, pp. [19] M. El-Habrouk, M.K.Darwish, P.Mehta, Active power filters: a review, Electric Power Applications, IEE Proceedings, [20] Vol. 147, No. 5, Sept. 2000 pp. 403 413. [21] NormanMarium, Ahsanul Alam, Senan Mahmod and Hashim Hizam, Review of control strategies for power quality [22] conditioners, Power and Energy Conference 2004, Proceedings. National, Nov. 2004, pp. 109-115. ISSN : 0975-5462 Vol. 3 No.10 October 2011 7586