ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Similar documents
Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

Harmonics Reduction using 4-Leg Shunt Active Power Filters

ABSTRACT I. INTRODUCTION

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Harmonics Elimination Using Shunt Active Filter

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

POWER QUALITY IMPROVEMENT USING SHUNT ACTIVE FILTER

Kanuru; Krishna (Dt); A.P, India. DOI: / Page. 1 G. Aruna Jyothi, 2 DR. P. V. R. L.

Control Of Shunt Active Filter Based On Instantaneous Power Theory

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

Harmonics Reduction of 3 Phase Diode Bridge Rectifier by Implementing P-Q Theory with Active Filter

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Power Quality improvement of a three phase four wire system using UPQC

Chapter 2 Shunt Active Power Filter

Application of Fuzzy Logic Controller in Shunt Active Power Filter

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

2020 P a g e. Figure.2: Line diagram of series active power filter.

Experimental Results of a Single-Phase Shunt Active Filter Prototype with Different Switching Techniques

Simulation Study of PWM Techniques for Voltage Source Converters

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Power Control and Quality Management in DG Grid Interfaced Systems

Active Harmonics Filtering of Distributed AC System

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Power Quality Improvement using Shunt Passive Filter

Power Control Scheme of D-Statcom

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Review on Shunt Active Power Filter for Three Phase Four Wire System

Improving the Power Quality by Four Leg VSI

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

Literature Review for Shunt Active Power Filters

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

Universal power quality conditioner

A Comparative Study on Four Time-Domain Harmonic Detection Methods for Active Power Filters Serving in Distorted Supply

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Indirect Current Control of LCL Based Shunt Active Power Filter

A Hysteresis based Active Shunt, Passive Series Hybrid Filter for Power Quality Improvement

ISSN Vol.04,Issue.08, July-2016, Pages:

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

CHAPTER 4 DESIGN OF DC LINK VOLTAGE CONTROLLER FOR SHUNT ACTIVE POWER FILTER

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

PI Controller Based Shunt Active Power Filter with Cascaded Multilevel Inverter

Performance Analysis of Shunt Active Power Filter Base On Active Reactive Power Theory

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Fig. 1 Schematic Diagram Showing Connections to the Active Filter With Non-Linear Load

Photovoltaic System Based Interconnection at Distribution Level With Different Loads

Control schemes for shunt active filters to mitigate harmonics injected by inverted-fed motors

IMPORTANCE OF VSC IN HVDC

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

HARMONIC contamination, due to the increment of nonlinear

ISSN Vol.03,Issue.07, August-2015, Pages:

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

CURRENT HARMONICS REDUCTION IN 3 PHASES 4 WIRE SYSTEM USING HYBRID FILTERS R.Saravanakumar 1#, S.Amritha 2#

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology


A Novel Control Strategy of Shunt Active Filters

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Dynamic Modeling and Simulation of Unified Power Quality Conditioner

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Selective Harmonic Elimination Using Three Phase Shunt Active Power Filter

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Compensation of Harmonics Power by using Shunt Active Filter

Transcription:

Design of Shunt Active Power Filter to eliminate the harmonic currents and to compensate the reactive power under distorted and or imbalanced source voltages in steady state Sangu Ravindra #1, Dr.V.C.Veera Reddy #2, Dr.S.Sivanagaraju #3 #1 Asso.Prof, Dept of EEE, QISCET, Ongole, #2 Professor, Dept of EEE,S.V.U college of Engg, Tirupathi, #3 Asso.Prof, Dept of EEE, JNTU Kakinada, Abstract - The shunt active power filter has proved to be a useful device to eliminate harmonic currents and to compensate reactive power for linear/nonlinear loads. This paper presents a novel approach to determine reference compensation currents of the three-phase shunt active power filter (APF) under distorted and/or imbalanced source voltages in steady state. The proposed approach is compared with three reviewed shunt APF reference compensation strategies. Results obtained by simulations with Matlab and Simulink show that the proposed approach is more effective than the reviewed approaches on compensating reactive power and harmonic/neutral currents of the load, even if the source voltages are severely distorted and imbalanced. In addition, the proposed approach yields a simpler design of the shunt APF. Index Terms: Shunt active power filter, Voltage source converters, Linear and nonlinear loads, PI Controllers. 1. INTRODUCTION The use of shunt active power filters (APF) to eliminate harmonic currents and to compensate reactive power for linear/nonlinear loads has attracted much attention since the late 1970s Fig. 1 shows the schematic diagram of a threephase four-wire shunt APF, where the APF senses the source voltages and load currents to determine the desired compensation currents. Akagi proposed the instantaneous reactive power theory (i.e.,p-q theory) for calculating the reference compensation currents required to inject into the network at the connected point of the nonlinear load. Since then, the theory has inspired many works dealing with active power filter compensation strategies One of the peculiar features of a shunt APF is that it can be designed without active energy source units, such as batteries, or in other forms in its compensation mechanism. In other words, an ideal APF does not consume any average real power supplied by the source. To accomplish this function, it requires an effective reference compensation strategy for both reactive power and harmonic/neutral current compensation of the load. Up to date, most reference compensation current strategies of the APF are determined either with or without reference-frame transformations. For instance, the theory proposed and requires transformation of both source voltages and load currents from the a-b-c reference frame to the alpha-beta reference frame to determine the APF reference compensation currents in the three-phase three-wire system. For applications of the APF in a three-phase four-wire system, extended the theory to handle the zero-sequence power compensation with a more complicated design. In the authors proposed the generalized instantaneous reactive power theory in the reference frame for harmonic and reactive power compensation.the advantages of the proposed approach are that no reference-frame transformation is required and a simpler APF design can be achieved. A synchronous reference frame method for obtaining the load currents at the fundamental frequency, which will be the desired source currents. The APF reference compensation currents are then determined by subtracting the fundamental components from the load currents. Proposed an algorithm in the reference frame for maintaining ideal three-phase source currents when the source voltages are amplitude-imbalanced. In theory, the aforementioned approaches work very well on harmonic and/or reactive power compensation for nonlinear loads under ideal source voltages. However, if the source voltages are imbalanced and/or distorted, the generated APF reference compensation currents are discrepant and the desired ISSN: 2231-5381 http://www.internationaljournalssrg.org Page 20

balanced/ sinusoidal source currents cannot be maintained.among many approaches for determining the APF reference compensation currents, one of the mainstreams is to maintain sinusoidal source currents supplying average real power to the load. With the use of sinusoidal source current strategy, it is proved that the APF can have better performance than other strategies.to achieve full compensation of both reactive power and harmonic/neutral currents of the load, this paper presents a novel approach to determine the shunt APF reference compensation currents, even if the source voltages and load currents are both imbalanced and distorted. The proposed approach is similar to those presented; it is an - reference-frame-based method and is categorized as a sinusoidal source current strategy. In the paper, a brief review of the three approaches proposed in first described. Next, the theory of the proposed strategy is presented. The Matlab/Simulink simulations are then followed to compare the usefulness of the proposed method and the reviewed approaches. A three-phase system feeding an inverter load has been selected to study the performance of the APF system. It has been observed that due to the non-linear characteristics of power electronics loads the THD s of source current and terminal voltage fall well below the IEEE-519 standard and in principle APF system is used to inject a current equal in magnitude but in phase opposition to harmonic current to achieve a purely sinusoidal current wave inphase with the supply voltage. Figure 1 shows the single-line diagram of a simple power system with APF system ON. The heart of the APF system is the IGBT based voltage source inverter (VSI). A dc capacitor is used to deliver power for the VSI. For the successful operation of APF, capacitor voltage should be at least 150 % of maximum line-line supply voltage. Since the PWM VSI is assumed to be instantaneous and infinitely fast to track the compensation currents, it is modeled as a current amplifier with unity gain. II. SHUNT ACTIVE POWER FILTER A. DETERMINATION OF APF REFERENCE COMPENSATION CURRENTS: Fig.1. Schematic diagram of three phase four wire shunt active power filter with linear & nonlinear loads Active filters are implemented using a combination of passive and active (amplifying) components, and require an outside power source. Operational amplifiers are frequently used in active filter designs. These can have high Q, and can achieve resonance without the use of inductors. However, their upper frequency limit is limited by the bandwidth of the amplifiers used. Multiple element filters are usually constructed as a ladder network. These can be seen as a continuation of the L,T and π designs of filters. More elements are needed when it is desired to improve some parameter of the filter such as stop-band rejection or slope of transition from pass-band to stop-band. The proposed compensation strategy of the active power filter is based on the requirement that the source currents need to be balanced, undistorted, and in phase with the positivesequence source voltages. The goals of the shunt APF control are: 1) unity source power factor at positive-sequence fundamental frequency; 2) minimum average real power consumed or supplied by the APF; 3) harmonic current compensation; and 4) neutral current compensation. Therefore, the active power filter must provide full compensation (i.e., harmonic/neutral currents and reactive power) for the nonlinear load. To achieve these goals, the desired three-phase source currents must be in phase with the positive-sequence fundamental source voltage components. III. VOLTAGE SOURCE CONVERTERS A. VSC BASED TRANSMISSION: The fundamentals of VSC transmission operation may be explained by considering each terminal as a voltage source connected to the AC transmission network via a three-phase reactor. The two terminals are interconnected by a DC link..4 Fig: 2 shows a phasor diagram for the VSC converter connected to an AC network via a transformer inductance. The fundamental voltage on the valve side of the converter ISSN: 2231-5381 http://www.internationaljournalssrg.org Page 21

transformer, i.e. UV(1), is proportional to the DC voltage as been expressed in Eq(1). UV(1) = kuud ---------- (1) The quantity ku can be controlled by applying additional number of commutation per cycle, i.e. applying pulse with modulation (PWM). Using the definition of the apparent power and neglecting the resistance of the transformer results in the following equations for the active and reactive power: The active and reactive power will in the following be defined as positive if the powers flow from the AC network to the converter. The phase displacement angle δ will then be positive if the converter output voltage lags behind the AC voltage in phase. The active power or the DC voltage is controlled by the control of δ and the reactive power is controlled by the control of the modulation index (m). The instantaneous real and imaginary power of the inverter on the valve side can be expressed in terms of the dq. IV. TWO AXIS REPRESENTATION OF CURRENTS 3-PHASE The control strategy of the active filter is based on the generation of reference source currents. These reference source currents are generated using synchronous frame reference theory (SRF). The load currents (i la, i lb, i lc ), PCC voltages (v a, v b, v c ) and dc link voltage (V dc ) are sensed and used as feedback signals. The load currents in abc coordinates are transformed in to d-q coordinates using Park s transformation. The d-q components of the load currents are calculated as, 2 2 cos cos cos i la i ld 2 3 3 i lb i lq 3 2 2 sin sin sin i lc 3 3. (2) Fig:2 Phasor diagram of VSC and direction of power flows Where cosθ and sinθ are obtained from three phase PLL. These d-axis and q-axis currents can be separated into two parts namely average and oscillatory parts as, i i i ld ld ld.. (3) i i i lq lq lq.. (4) B. OUTER ACTIVE AND REACTIVE POWER AND VOLTAGE LOOP: The reference source currents in d-q coordinates are transformed into abc coordinates using inverse Parks transformation and it is expressed as, i cos sin a 2 2 2 id os sin b 3 3 3 i q i c 2 2 cos sin 3 3.. (5) 1) PWM CURRENT CONTROLLER: Fig: 3 Overview diagram of the VSC control system The reference source currents (i a, i b and ) are compared with the sensed source currents (i a, i b and ). The ON/OFF switching patterns of the gate drive signals to the IGBTs are generated from the PWM current. The current errors are computed as, ISSN: 2231-5381 http://www.internationaljournalssrg.org Page 22

i i -i aerr a a ; i i - i ; i i - i. (6) berr b b cerr c c i i - i ; aerr a a i i - i ; i i - i. (9) berr b b cerr c c These current error signals are fed to a carrier less PWM current for switching of the IGBTs of the VSC of the active filter. i la i lb i lc v a v b v c abc V dc V dcref d-q-o PLL ild PI LPF (cosθ,sinθ) i ld i loss 0 i d i q d-q-o abc i a i b Hysteresis current Fig: 4 Gating signals for PWM current 2) PWM FOR POWER BALANCE THEORY: ia ib ic Gating Signals The control strategy of the active filter is based on the generation of reference source currents. The reference source currents are generated using power balance theory (PBT). The load currents (i la, i lb, i lc ), PCC voltages (v a, v b, v c ) and dc link voltage (V dc ) are sensed and used as feedback signals. These current error signals are fed to a carrier less PWM current for switching of the IGBT of the VSC of the active filter. i la i lb i lc v a v b v c V dc V dcref Active power measurent Amplitude in-phase unit templates u a u b u c LPF P 2 3 PI V t i a i b ia Hysteresis current ib Gating Signals for 3-leg VSC Fig: 5 Gating signals for Carrier less PWM current V. SIMULATION RESULTS I lp I loss I p Three phase voltages at the generator terminals (v a, v b and v c ) are sensed and amplified to compute their amplitude as, 2 V v v v 3 2 2 2 t a b c. (7) The dc bus voltage error V dcer at nth sampling instant is expressed as, V V -V (8) dcer ( n) dcref ( n) dc( n) Where V dcref is the reference dc voltage and V dc(n) is the sensed dc link voltage of the CC-VSC. The output of the PI for maintaining the dc bus voltage of the CC-VSC at the n th sampling instant is expressed as, Fig:6 Total Hormin distorsion in output voltage for unbalanced supply voltages The reference source currents (i a, i b and i c) are compared with the sensed source currents (i a, i b and ). The ON/OFF switching patterns of the gate drive signals to the IGBTs are generated from the PWM current. The current errors are computed as, ISSN: 2231-5381 http://www.internationaljournalssrg.org Page 23

Fig:7 Total Hormin distorsion without active filter for nonlinear loads Fig:8 Total Hormin distorsion with active filter VI CONCLUSION This is the only method when the loads may be balanced/unbalanced, linear/non-linear and any distortion the source current must be sinusoidal. Because of this we can preferred this proposed approach method. The AF is observed to eliminate the harmonic and reactive components of load current resulting in sinusoidal and unity power-factor source currents. It is observed that the source current remains below the load current even during transient conditions. The AF enhances the system efficiency because the source need not process the harmonic and reactive power demanded by the load. This paper presented a novel approach to determine reference compensation currents of the three phases shunt active power filter (APF) under distorted and/or imbalanced source voltages in steady state. The proposed approach was compared with three reviewed shunt APF reference compensation strategies. Among many approaches for determining the APF reference compensation currents, one of the mainstreams is to maintain sinusoidal source currents supplying average real power to the load. With the use of sinusoidal source current strategy, it is proved that the APF can have better performance than other strategies. VII REFERENCES [1] H. Akagi, Y. Kanazawa, A. Nabae, Generalize Theory of the Instantaneous Reactive Power in Three-Phase Circuits, IPEC'83 - Int. Power Electronics Conf., Tokyo, Japan, 1983, pp. 1375 1386. [2] H. Akagi Y. Kanazawa, A. Nab Instantaneous Reactive Power Compensator Comprising Switching Devices without Energy Storage Components, IEEE Trans. Industry \ Applic., vol. 20, May/June 1984. [3] E. H. Watanabe, R. M. Stephan, M. Aredes, New Concepts of Instantaneous Active and Reactive Powers in Electrical Systems with Generic Loads, IEEE Trans. Power Delivery, vol. 8, no. 2, April 1993, pp. 697-703. [4] M. Aredes, E. H. Watanabe, New Control Algorithms for Series and Shunt Three-Phase Four- Wire Active Power Filters, IEEE Trans. Power Delivery, vol 10, no. 3, July 1995, pp. 1649-1656. [5] J. L. Afonso, C. Couto, J. S. Martins, Active Filters with Control Based on the p-q Theory,IEEE Industrial Electronics Society Newsletter, vol. 47, nº 3, Set. 2000, pp. 5-10. [6] J. L. Afonso, H. R. Silva, J. S. Martins, Active Filters for Power Quality Improvement, IEEE Power Tech 2001, Porto, Portugal, 10-13 Set. 2001. [7] Simulink Model-Based and System-Based Design, Modelling, Simulation,Implementation version 5,The MathWorks, July 2002. [8] IEEE Working Group on Nonsinusoidal Situations: Efects on Meter Performance and Definitions of Power, Practical definitions for powers in systems with nonsinusoidal waveforms and unbalanced loads: a discussion, IEEE Trans. Power Delivery, vol. 11, no. 1, pp. 79 101, Jan. 1996. [9] A. E. Emanuel, Summary of IEEE Standard 1459: definitions for the measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions, IEEE Trans. Ind. Appl., vol. 40, no. 3, pp. 869 876, May/Jun. 2004. ISSN: 2231-5381 http://www.internationaljournalssrg.org Page 24