HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

Similar documents
HEINE Direct Ophthalmoscopes

HEINE BETA 200S Ophthalmoscope

HEINE Direct Ophthalmoscopes

HEINE Direct Ophthalmoscopes

HEINE mini 3000 Pocket Diagnostic Instruments Now Available with LED Illumination

Keeler Direct Ophthalmoscopes

BETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS

Wide Angle Ophthalmoscope Instructions

Professional Optometric Student Guide

Understanding your Direct Ophthalmoscope

Lecture 2 Slit lamp Biomicroscope

Vantage Plus. The best just gets better. LED illumination. Slimline Polymer battery. New Standard Combined. Longest life Brightest Better detail

Beautifully Crafted Slit Lamps

Eyes. Inspection Visual Acuity Visual Fields Pupillary Response Fundoscopic Exam

Basic Principles of the Surgical Microscope. by Charles L. Crain

Kinder products for your most precious patients

Ophthalmic Instruments

Beautifully Crafted Slit Lamps

2012 Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

INTRODUCTION. SO-2200LED Binocular Indirect Ophthalmoscope

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

Learn Connect Succeed. JCAHPO Regional Meetings 2017

11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?

Impressive Wide Field Image Quality with Small Pupil Size

The First True-Color Wide-Field Confocal Scanner

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

RETINOSCOPY LABORATORY MICHAEL DAVIDSON RON OFRI

Xcel 255 & 455 Slit Lamps

The First True Color Confocal Scanner

The First True Color Confocal Scanner on the Market

Keeler. Innovator, market leader, with a focus on the future. UK manufacturer. Service. Reliability. 2

Beautifully Crafted Slit Lamps.

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

you can We have an eye for detail. CF-1 HIGH RESOLUTION DIGITAL RETINAL CAMERA Camera Canon EOS 1Ds Mark III f7.1 1/800 ISO 320

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

Retinoscopy: Research Applications

ED-Lenses. Zoom. Boating. Spectator Sports. Travel & Hiking. Hunting. Mountaineering. Wildlife & Observation. Aspherical Lenses

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

Training Eye Instructions

All-Glass Ophthalmic Lenses

Professional Optometric Student Guide

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

YZ11D OPHTHALMOSCOPE INSTRUCTION MANUAL

Instruments Commonly Used For Examination of the Eye

KTP LASER. Photocoagulation System

Physics Chapter Review Chapter 25- The Eye and Optical Instruments Ethan Blitstein

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

MrN Physics Tuition in A level and GCSE Physics AQA GCSE Physics Spec P3 Optics Questions

Marco TRS Total Refraction System

2Win Binocular Mobile Refractometer and Vision Analyzer

Preface. General Requirements for Safety. Precautions

25 cm. 60 cm. 50 cm. 40 cm.

CONTACT LENSES Discover a different world

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

THE ONLY PORTABLE, AFFORDABLE INSTRUMENT OFFERING THREE-DIMENSIONAL VIEWING AND ILLUMINATION INTO A SMALL CAVITY.

The A-Scan Plus. Cataract Surgeons who do their homework...get an A-Plus. Product #

Systems Biology. Optical Train, Köhler Illumination

Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification.

SLIT LAMP BQ 900 Sophisticated microscopy

OCULUS Pentacam AXL Always an Axial Length Ahead

Chapter 25. Optical Instruments

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Keratometry: Vertical Axis. Axis

OCULUS Keratograph 4. Topographer. We focus on progress

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

WEARABLE WIRELESS ADAPTIVE REFRACTOR

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

ATLAS Corneal Topography System

CX-1 digital retinal camera mydriatic & non-mydriatic. Redefining true versatility.

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

VISIOMED Luminis A New Standard in Dermoscopy

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Refraction, Lenses, and Prisms

Medical Photonics Lecture 1.2 Optical Engineering

Going beyond the surface of your retina

SLIT LAMPS Confidence that lasts

Better diagnosis and treatment all-in-one.

MEDICARE GB LTD LIGHTING CATALOGUE. Approved Luxo Dealer

Multiple-Choice Questions

Optical Coherence Tomography Retina Scan Duo

Unique Aberration-Free IOL: A Vision that Patients

LED Slit Lamp XL-1. Operations Manual. The contents of this Instruction Manual may be changed without prior notice. D06-S e Rev1.

Chapter 3 Optical Systems

Chapter 36. Image Formation

LEOK-3 Optics Experiment kit

Loupe and LED Illumination Systems. The Lightness of Seeing

Fundus Photograph Reading Center

Optical Connection, Inc. and Ophthonix, Inc.

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Easy Kohler Illumination Method

Lecture 15 Chap. 6 Optical Instruments. Single lens instruments Eyeglasses Magnifying glass. Two lens Telescope & binoculars Microscope

PHYS 160 Astronomy. When analyzing light s behavior in a mirror or lens, it is helpful to use a technique called ray tracing.

Refractive Power / Corneal Analyzer. OPD-Scan III

Transcription:

HEINE QUALITY M A D E I N G E R M A N Y :- HEINE Hand-held Ophthalmic Instruments

:- HEINE HSL150 Hand-held Slit Lamp Uncompromisingly compact. HEINE QUALITY M A D E I N G E R M A N Y

003 [ HEINE HSL150 HAND-HELD SLIT LAMP ] [ HEINE HSL150 HAND-HELD SLIT LAMP ] The ideal portable addition to a static full-size slit lamp. ORDER NO. [ HEAD ONLY ] : 3.5V [ C-002.14.602 ] 2.5V [ C-001.14.602 ] HSL150 features bright, white XHL Xenon Halogen illumination comparable in intensity with the best static slit lamps for examination of the anterior segment. The compact, ergonomic design provides instant loupe alignment of the slit image for comfortable operation. HSL150 provides a 10mm x 0,2mm up to 14mm x 4mm slit image for direct focal illumination with an optical section. The ideal alternative for examinations where a static slit lamp is not available or practical to use. This hand-held slit lamp is invaluable for screening, in accident and emergency rooms, and for bed-ridden patients or small children. :- Magnified view with 20-Diopter loupe. :- Instant selection of interference cobalt blue filter (FITC) for corneal examination. :- Instant selection of loupe position for optimal alignment with slit. :- Advanced multi-coated optics maximize light transmission and reduce reflexes. :- Full metal construction assures perfect optical alignment and will provide a lifetime of reliable performance. :- HEINE 2.5V or 3.5V XHL Xenon Halogen Technology provides a bright, white light for true full-size slit lamp brightness. :- Continuously adjustable brightness control. :- Compact design for complete portability and ease of use. :- 100% dustproof construction, for a lifetime of maintenance-free performance. :- The HSL150 instrument head weighs only 70 g, the lightest portable Slit lamp available. :- 6x magnification. HEINE HSL150 Hand-held Slit Lamp with HEINE BETA SLIM handle Typical applications include: :- Corneal examination for foreign bodies or ocular trauma. :- Corneal examination with fluorescein using the precision interference cobalt blue filter (FITC). :- General examination of the anterior segment, iris and crystalline. :- Primary diagnosis of patients with eye infections. :- Examination of elderly and bed-ridden patients. :- Contact lens work. :- Industrial medicine. [ HEINE HSL10x LOUPE ATTACHMENT ] ORDER NO. [ LOUPE ATTACHMENT ] : [ C-000.14.606 ] Loupe attachment with 10x magnification for HSL150. With precision magnification optics for crisp, clear images. :- 10x magnification when combined with HSL150 Loupe. :- Increased working distance from examiner to patient. :- Large field of view. :- With an additional detachable TP-elastomer Eyepiece to steady the instrument on the brow and avoid stray light. Can be replaced with a soft TP-elastomer cap, suitable for spectacle-wearers. HEINE HSL10x Loupe Attachment

:- HEINE LAMBDA 100 Retinometer Unique design. HEINE QUALITY M A D E I N G E R M A N Y

005 [ HEINE LAMBDA100 RETINOMETER ] [ HEINE LAMBDA100 RETINOMETER ] The first compact instrument for assessing potential visual acuity of patients with cataracts and other opacities. LAMBDA100 clinically tested with excellent results. ORDER NO. [ HEAD ONLY ] : 3.5V [ C-002.35.015 ]* 2.5V [ C-001.35.015 ]* 3.5V [ C-002.35.010 ]** 2.5V [ C-001.35.010 ]** * with acuity scale 20/300 to 20/25 (scale 2) ** with acuity scale 0.06 to 0.8 (decimal scale 1) :- Simple, easy-to-use controls. Reliable diagnosis, easy to operate. :- The instrument fits onto battery- or rechargeable handles. Complete mobility no dependence on the slit lamp. :- Compact, lightweight (100 g). Can be used anywhere even bedside. :- HEINE XHL Xenon Halogen Technology and brightness control. Avoids patient discomfort from dazzle. :- Includes explanatory card for patient instruction. HEINE LAMBDA 100 Retinometer with HEINE BETA handle Examples of various acuity grating patterns (visual angle 1 ) Three simple steps to potential acuity assessment with LAMBDA 100. [ 01 ] Switch on instrument, select acuity, select grating angle, reduce ambient lighting. [ 02 ] Rest Retinometer against the patient s forehead. Scan the pupil with the red light spot to find a window through which the patient can recognize the grating pattern and identify its angle. [ 03 ] Select progressively-finer grating patterns with different angles until the patient can no longer recognize the angle. The value of the last recognizeable angle indicates potential acuity. 0 20 Visus = 0,5( 40 ) 45 Visus = 0,32 20 ( 60 ) 90 20 Visus = 0,06 ( 300 )

:- HEINE BETA 200S Ophthalmoscope Perfection in detail. HEINE QUALITY M A D E I N G E R M A N Y

007 [ HEINE BETA200S OPHTHALMOSCOPE ] [ HEINE BETA 200S OPHTHALMOSCOPE ] Superior aspherical optics. ORDER NO. [ HEAD ONLY ] : 3.5 V [ C-002.30.120 ] 2.5 V [ C-001.30.120 ] The BETA 200S is the first hand-held direct ophthalmoscope with a combination of aspherical optics and single-step diopter selection from -36D to +38D for precise lens selection and a crisp, focused fundus image in all diagnostic situations. HEINE s unique Aspherical Optical System uses the Gullstrand principle to separate the illumination and observation beams. Corneal and iris reflexes are avoided and a complete section of the retina is visible even with a small pupil. 7 apertures for diagnostic flexibility in both large and small pupils. :- Aspherical optics avoid corneal and iris reflex. :- 74 single-diopter steps (from -36 to +38 dpt) for perfect focus even with high refractive error. :- The optics are mounted on a metal frame to ensure a lifetime of optical precision. :- 7 different apertures for retinal examination with both large and small pupils. :- Separate interference red-free filter for improved contrast when viewing retinal blood-vessels. :- A powerful HEINE XHL Xenon Halogen bulb for full illumination with bright, white light. :- Dustproof and maintenance-free for the life of the instrument. :- The ergonomic rounded shape fits the orbita comfortably. Ergonomic, one-handed operation. :- The multi-coated, recessed eyepiece avoids stray light during the examination. :- The soft brow rest steadies the instrument and protects the examiners glasses. HEINE BETA200S Ophthalmoscope with HEINE BETA handle Apertures [ A ] [ B ] Unique Aspherical Optical System (AOS) from HEINE reduces corneal and iris reflexes to provide large, crisp and glare-free fundus images. [ 01 ] Cobalt blue filter [ 02 ] Fixation star with polar co-ordinates [ 02 ] [ 01 ] [ 05 ] [ 03 ] Large aperture [ 04 ] Medium aperture [ 05 ] Macula aperture / MicroSpot [ 03 ] [ 04 ] [ 05 ] [ 06 ] Slit aperture [ 07 ] Hemispot [ A ] without red-free filter [ B ] with red-free filter [ 01 ] Flat, elliptical illumination beam produced by HEINE s Aspherical Optical System. [ 02 ] Observation beam. [ 03 ] Redirected iris and corneal reflexes. [ 04 ] The elliptical light beam enters through the lower half of the cornea. The illumination beam has been separated from the observation beam (Gullstrand-Principle). All reflexes are diverted away from the observation beam due to the curvature of the reflective cornea. Due to the flat, compressed form of the light beam, a maximum amount of light enters through the pupil. [ 05 ] Once past the anterior chamber, the light beam opens up dramatically to illuminate a large area of the retina.

:- HEINE BETA 200 Retinoscope A new benchmark. HEINE QUALITY M A D E I N G E R M A N Y

009 [ HEINE BETA 200 RETINOSCOPE ] [ HEINE BETA 200 RETINOSCOPE ] HEINE ParaStop for total precision in selecting a parallel beam. ORDER NO. [ HEAD ONLY ] : 3.5V [ C-002.15.353 ]* 2.5V [ C-001.15.353 ]* * Streak Retinoscope The retinoscope is used to measure the refractive error of the eye. Conditions such as long- and shortsightedness and astigmatism can be detected and measured. The BETA 200 Retinoscope with ParaStop and the latest in multi-coated optics provides an exceptionally-bright fundus reflex for improved accuracy of diagnosis. ParaStop was designed and developed to simplify precise selection of a parallel illumination beam. ParaStop helps to determine the cylinder axis more precisely and speeds up subsequent testing after refraction. The internal polarisation filter in the BETA 200 eliminates stray light and internal reflex without reducing brightness. :- ParaStop simplifies precise selection of a parallel beam. :- Multi-coated optics ensure bright, clear images. :- The internal polarisation filter eliminates stray light and internal reflex. :- A single control sleeve adjusts vergence of the beam and provides streak rotation. :- The powerful, bright HEINE XHL Xenon Halogen bulb ensures easy recognition of neutralisation. :- Can be changed from a streak to a spot retinoscope by simply changing the bulb. :- Instrument controls are made of metal to guarantee lifelong precision and quality of operation. :- Improved ergonomic shape effectively shields the examiner s orbit from stray light. :- Totally-dustproof, maintenance-free. :- Optional detachable orange filter for light-sensitive patients. :- Optional holder for fixation cards available. :- Includes detachable brow-rest for spectacle wearers. HEINE BETA 200 Retinoscope with HEINE BETA handle ParaStop and polarisation filter [ 01 ] [ 01 ] Polarisation filter, eliminates internal reflexes and stray light. [ 02 ] Semi-reflector mirror: Simultaneous illumination and observation. Reflected light from the retina enters the examiner s eye. [ 03 ] Condensor lens adjustable by a single control sleeve: Produces a divergent, convergent or parallel beam of light. [ 04 ] A special retinoscope bulb rotates for diagnosis of the cylinder axis. [ 05 ] ParaStop simplifies and speeds up the precise detection of cylinder axis. [ 05 ] [ 03 ] [ 04 ] [ 02 ]

.50 010 [ ORDERING INFORMATION ] HSL150 Hand-held Slit Lamp for BETA or BETA SLIM handles 2.5V 3.5V HSL150, without handle C-001.14.602 C-002.14.602 XHL Xenon Halogen spare bulb X-001.88.098 X-002.88.099 Replacement filter attachment for HSL150 HSL 10x Loupe Attachment for HSL150 C-000.14.605 C-000.14.606 Set complete with HSL150 and BETA SLIM handle (slim, compact), with: 2.5V 3.5V BETA SLIM battery handle, in soft pouch, without spare bulb C-252.10.105 same, with HSL10x Loupe Attachment, spare bulb, in hard case C-268.10.105 BETA SLIM rechargeable handle and NT 300 charger, spare bulb, in hard case C-266.20.470 same, with HSL10x Loupe Attachment, in hard case C-268.20.470 Set complete with HSL150, BETA handle (standard size) and spare bulb in hard case, with: 2.5V 3.5V BETA battery handle C-265.10.118 same, with HSL10x Loupe Attachment C-267.10.118 BETA R rechargeable handle C-265.20.376 C-265.27.376* BETA R rechargeable handle with HSL10x Loupe Attachment C-267.20.376 C-267.27.376 BETA TR rechargeable handle and transformer C-265.20.384 C-265.27.384* BETA TR rechargeable handle and transformer with HSL10x Loupe Attachment C-267.20.384 C-267.27.384 BETA NT rechargeable handle (NiMH) and NT 300 charger C-265.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-265.29.420* BETA NT rechargeable handle (NiMH) and NT300 charger with HSL10x Loupe Attachment C-267.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-267.29.420* *Price on request..12.32 LAMBDA 100 Retinometer 2.5V 3.5V LAMBDA 100 Retinometer head with acuity scale 20/ 300 to 20/ 25 (scale 2), without handle C-001.35.015 C-002.35.015 LAMBDA 100 Retinometer head with acuity scale 0.06 to 0.8 (decimal scale 1), without handle C-001.35.010 C-002.35.010 XHL Xenon Halogen spare bulb X-001.88.077 X-002.88.078 Patient card (for patient instruction prior to examination) C-000.35.005 Set complete with LAMBDA 100 Retinometer, acuity scale 0.06 to 0.8 (decimal scale 1), patient card and spare bulb in hard case, with: 2.5V 3.5V BETA battery handle C-187.10.118 BETA R rechargeable handle C-187.20.376 C-187.27.376 BETA TR rechargeable handle and transformer C-187.20.384 C-187.27.384 BETA NT rechargeable handle (NiMH) and NT 300 charger C-187.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-187.29.420 Set complete with LAMBDA 100 Retinometer, acuity scale 20/300 to 20/25 (scale 2), patient card and spare bulb for each instrument in hard case, with: 2.5V 3.5V BETA battery handle C-189.10.118 BETA R rechargeable handle C-189.20.376 C-189.27.376 BETA TR rechargeable handle and transformer C-189.20.384 C-189.27.384 BETA NT rechargeable handle (NiMH) and NT 300 charger C-189.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-189.29.420 : Rechargeable handle with charge status display in the bottom insert.

ParaStop US Pat. 5.859.687 US Pat. 5.859.687 011 [ ORDERING INFORMATION ] BETA 200S Ophthalmoscope 2.5V 3.5V BETA 200S Ophthalmoscope, without handle C-001.30.120 C-002.30.120 XHL Xenon Halogen spare bulb X-001.88.069 X-002.88.070 Set complete with BETA 200S Ophthalmoscope, 1 spare bulb in hard case, with: 2.5V 3.5V BETA battery handle C-261.10.118 BETA R rechargeable handle C-261.20.376 C-261.27.376 BETA TR rechargeable handle and transformer C-261.20.384 C-261.27.384 BETA NT rechargeable handle (NiMH) and NT 300 charger C-261.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-261.29.420 BETA 200 Streak-Retinoscope 2.5V 3.5V BETA 200 Streak Retinoscope with XHL Xenon Halogen bulb, detachable brow rest, without handle C-001.15.353 C-002.15.353 XHL Xenon Halogen spare bulb for Streak Retinoscope X-001.88.087 X-002.88.089 XHL Xenon Halogen spare bulb to convert to Spot Retinoscope X-001.88.088 X-002.88.090 Bulb holder Bulb-cover Detachable brow rest for spectacle-wearers Orange filter for light-sensitive patients Fixation cards with holder for dynamic retinoscopy C-000.15.355 C-000.15.356 C-000.15.357 C-000.15.359 C-000.15.360 Set complete with BETA 200 Streak Retinoscope, 1 spare bulb in hard case, detachable brow rest, with: 2.5V 3.5V BETA battery handle C-034.10.118* BETA R rechargeable handle C-034.20.376 C-034.27.376 BETA TR rechargeable handle and transformer C-034.20.384 C-034.27.384 BETA NT rechargeable handle (NiMH) and NT 300 charger C-034.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-034.29.420 * Available with large battery handle X-001.99.120 (doesn t fit into hard cases). Please specify with your order. ParaStop Set complete with BETA 200S Ophthalmoscope, BETA 200 Streak Retinoscope, detachable brow rest, 1 spare bulb each in hard case, with: 2.5V 3.5V BETA battery handle C-262.10.118 BETA R rechargeable handle C-262.20.376 C-262.27.376 BETA TR rechargeable handle and transformer C-262.20.384 C-262.27.384 BETA NT rechargeable handle (NiMH) and NT 300 charger C-262.20.420 same, with BETA L rechargeable handle with Lithium-Ion battery C-262.29.420 : Rechargeable handle with charge status display in the bottom insert.

HEINE SUBSIDIARY COMPANIES HEINE REPRESENTATIVES A company makes history and gives a name to outstanding product quality: HEINE. Founded in 1946, family owned, rich in tradition and today international market leader in a complete range of diagnostic instruments. HEINE products meet all international standards (ISO/CE) and represent the leading edge in precision and ergonomic design. Ongoing dedication to research and development has created a solid and diverse technology base for continued quality and product leadership. Over 500 employees worldwide contribute to this success. www.heine.com GERMANY HEINE Optotechnik GmbH & Co. KG 82211 Herrsching Kientalstr. 7 Tel. +49 (0) 81 52-38 0 Fax +49 (0) 81 52-3 82 02 E-Mail: info@heine.com NORTH AMERICA HEINE USA LTD. 10 Innovation Way Dover, NH 03820 Tel. (603)742-71 03 Fax (603)742-72 17 Toll Free (800) 367-4872 E-Mail: service@heine-na.com AUSTRALIA HEINE AUSTRALIA PTY. LTD. Unit 9, 98 Old Pittwater Road P.O. Box 717 Brookvale 2100 New South Wales Tel. +61 (0) 2-99 38 95 00 Fax +61 (0) 2-99 39 23 05 E-Mail: info@heine.com.au SWITZERLAND HEINE (Schweiz) AG Tobeläckerstr. 9 CH-8212 Neuhausen am Rheinfall Tel. +41 (0) 52-6 72 22 66 Fax +41 (0) 52-6 72 63 77 E-Mail: heine-schweiz@schaffhausen.ch We reserve the right to change specification without notice. Your distributor 11/11. A-000.00.230 e