Digital Multimeter, Pen Type

Similar documents
Digital Clamp Meter Model: &

DIGITAL MULTIMETER AUTORANGING

Digital Multimeter with Backlight

Model: &

True RMS Digital Multimeter Model:

Mini Clamp Meter Model:

AMM-1022 Digital Multimeter USER`S MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Multifunction Digital

AC/DC CLAMP METER USER S MANUAL

MODEL: D03128 CLAMP METER

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

User Manual. All rights reserved. Specifications are subject to change without notice.

MS8223A. CAT.IIi 600 V

Model DIGITAL MULTIMETER

KMD-S04 Multímetro de bolsillo

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Pocket Size Digital Multimeter Models: and

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

OPERATOR S INSTRUCTION MANUAL

ProfiScale MULTI Multimeter

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

3B SCIENTIFIC PHYSICS

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

CONTENTS MS2033A. 1.Introduction Safety Information...01

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User Manual. All rights reserved. Specifications are subject to change without notice.

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês

Pen-type DIGITAL MULTITESTER

User Manual Digital Multimeter

DVM1190 DIGITAL MULTIMETER

Model UT10A: OPERATING MANUAL Table of Contents (1)

MS2030 CAT III 600 V A V AUTO RS232

DCM730. Digital Clamp Meter User s Manual

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Dawson DDM190. Digital Multimeter User s Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Digital Clamp Meter. User Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

DIGIT & POINTER MULTIMETER

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

LCR METER Model:

OPERATOR S INSTRUCTION MANUAL

Model UT201/202: OPERATING MANUAL. Table of Contents

AX-C Introduction. 2. Safety Information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model : OPERATING MANUAL Table of Contents (1)

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

DDM350 Pen-Type Digital Multimeter User s Manual

UT207A/208A/209A Operating Manual. Table of Contents

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

DMM8900 SERIES USERS MANUAL

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

INSTRUCTION MANUAL DIGITAL MULTIMETER

Electrical Multimeter

Table of Contents Title Page

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Table of Contents GDM-356. Page

LCR METER Model:

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

MS2109A AC/DC Clamp Meter. User Manual. Contents

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

DIGITAL CLAMP METER Use s Manual

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Handheld Digital Multimeter PRO-50A

Model UT20B: OPERATING MANUAL Table of Contents (1)

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Pocket Size Digital Multimeter with USB Model: A & A

DIGITAL MULTIMETER OPERATOR S MANUAL

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Electrical Multimeter

USER'S MANUAL DMR-4350

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

VC835 DIGTAL MULTIMETER Operation Manual

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

312, 316, 318. Clamp Meter. Users Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Pen Multimeter. Model

AUTO-SCAN Pen R/C/D Meter for SMD AX-507B USER S MANUAL

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Model UT50D: OPERATING MANUAL. Table of Contents

The Meter Structure The Figure 2-1 shows the Meter structure.

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Transcription:

MODEL: D03127 Digital Multimeter, Pen Type 1

CONTENTS Page Number Description 3 Important Safety Information 3 Electrical Symbols 4 Overview 4 Measurement Operation 5 AC & DC Voltage Measurement 5 AC & DC Current Measurement 5 Resistance Measurement 6 Diode Measurement 6 Connectivity Test 6 Non-contact Voltage Detection 6 General Technical Specification 7 Accuracy Specifications 8 Cleaning & Maintenance 8 Replacing the Batteries 2

IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. When using electrical appliances basic safety precautions should always be followed. Before use, check that there is no damage to the instrument, there is no metal exposed or sign of wear to the insulating layer of the probe. Do not touch the charged body with voltage exceeding 30V AC RMS, 42V AC or 60V DC. When the low battery indicator is displayed, replace the battery immediately to avoid any potential measurement error. The input measurement voltage should not exceed the rated value regulated by the instrument. Do not use the instrument around explosive gas, steam or in a wet environment. When measuring, connect the zero/ground line first, then connect the live wire. When disconnecting, ensure you disconnect the live wire first and then disconnect the zero line and ground line. When measuring, ensure your fingers are behind the finger protector of the probe. Do not use the instrument in the event of a single element, whose rating is the lowest in the instrument, probe or accessories, exceeding the measurement category (CAT) ratings. ELECTRICAL SYMBOLS Symbol Description ~ ~ High voltage warning. AC (Alternating Current). DC (Direct Current). AC or DC.. Important safety information. Ground. Fuse. Equipment with double insulation protection. CAT III CAT III measurement is suitable for test and measurement of circuits which are connected to the mains installation of a building. 3

OVERVIEW Number 1 Test probe 2 Light Description 3 Non-contact voltage induction area 4 Non-contact voltage indicator 5 Rotary dial 6 Display 7 Buttons: Data Hold Range Select Backlight and Light - press and hold for more than two seconds to turn the backlight on. Press and hold for two more seconds to turn off. 8 Black probe 1 2 3 4 5 6 7 8 MEASUREMENT OPERATION Manual & Automatic Range The instrument is equipped with manual and automatic range. In automatic range mode, the instrument will select the best range for the input signal detected. This way the user does not need to re-select range when changing the measuring signal. The instrument can also be set to manual range. The default mode is automatic range mode after the unit is turned the default mode is automatic range on or the function is switched, the instrument displays AUTO symbol. The operations of entering or quitting manual range are as follows: - In automatic range mode, press the Range button. The AUTO symbol will be hidden. - Press the Range button to increase the range. When the maximum range is reached it will return to the minimum range. - Press and hold the Range button for two seconds to quit manual range mode. The instrument will display the AUTO symbol. Note: There is only one range for connectivity and diode function. If there is no operation for 15 minutes after being turned on, the instrument will make five short sounds. One minute later, it will make a longer sound before automatically turning off. After automatic turn-off, press any button between FUNC. and HOLD and the instrument will turn back on. By pressing the FUNC. button to turn the instrument back on, it will cancel the 4

AC & DC VOLTAGE MEASUREMENT Move the rotary dial to, press the FUNC. button and select DC or AC voltage measurement. Connect the probe to be measured to the circuit or power supply in parallel and measure the voltage. Read the measurement on the screen. When measuring DC voltage, the display also shows the voltage polarity of the red probe test point. Do not input voltage above 600V as there is a risk of damaging the instrument. AC & DC CURRENT MEASUREMENT Move the rotary dial to the position, press the FUNC. button and select DC or AC current measurement. Cut off the power supply to the measured circuit and discharge all of the high voltage capacitors on the Disconnect the circuit to be tested and connect the instrument to the circuit to be measured in series. Connect to the power supply of the circuit and then read the measurement on the screen. When measuring DC current, the display also shows the voltage polarity of the red probe test point. Note: If OL is displayed it means that the instrument exceeds the measurement range of the instrument. Disconnect the circuit to be tested, remove the probe of the instrument and restore the circuit. Do not input current above 200mA, otherwise the fuse in the instrument may be burned. Disconnect the power supply of the measured circuit firstly and fully discharge all high voltage capacitors, then connect the instrument to the circuit in series. RESISTANCE MEASUREMENT Move the rotary dial to the position. Note: If it s not in the resistance measurement function, press FUNC. to switch to resistance measurement function. Connect the probe to the circuit to be measured in parallel and measure the resistance. Read the measurement result of the screen. Firstly, disconnect the power supply of the circuit to be measured and fully discharge all high voltage capacitors. 5

DIODE MEASUREMENT Move the rotary dial to the position and switch to the diode function. Contact the red probe to the anode of the measured diode, and the black probe to the cathode of the measured diode. The reading on the screen is the approximate value of the diode forward voltage drop. If it is connected in reverse, it will display OL. Firstly, disconnect the power supply of the circuit and discharge all high voltage capacitors. If the diode to be tested is an open circuit or with reverse polarity, the instrument will display OL. CONNECTIVITY TEST Move the rotary dial to the position, press FUNC. and switch to the connectivity function. Contact the probe to both ends of the When the resistance of the measured circuit is below 50Ω, the buzzer will sound. Firstly, disconnect the power supply of the circuit to be measured and fully discharge all high voltage capacitors. NON-CONTACT VOLTAGE DETECTION Move the rotary knob of the instrument to NCV. Approach the non-contact voltage induction area of the instrument to the live wire of the AC voltage (less than 5mm). The non-contact voltage indicating light of the instrument will light up. At the same time there is a beep, which indicates that there is AC voltage on the fire wire. GENERAL TECHNICAL SPECIFICATION Environmental conditions for use Working environment temperature & humidity Storage environment temperature & humidity Temperature coefficient Max. Voltage allowed between measuring terminal and ground Fuse Protection Sampling rate IEC/EN 61010-1 600V CAT III, pollution level 2, altitude <2000m 0~40 C -10~60 C (remove the battery when it is below 70%RH) 0.1 x accuracy/ C DC or AC 600V RMS Fuse FF 250mA/600V About 3 times/second 6

Display 3½ LCD screen Super range indication LCD display screen will display OL Low battery indication will be displayed on the screen Input polarity indication Automatically displays - Power supply 2 x 1.5V AAA batteries Dimensions 225mm x 38mm x 26mm ACCURACY SPECIFICATIONS The accuracy is applicable within one year of calibration. Reference conditions: the environmental temperature is 18 C to 28 C and relative humidity is no more than 80%. DC Voltage 200mV 0.1mV 2V 0.001V 20V 0.01V ± (0.5% reading + 3) 200V 0.1V 600V 1V ± (0.8% reading + 5) Input impedance: 10MΩ. Maximum input voltage: DC or AC 600V RMS. AC Voltage 2V 0.001V 20V 0.01V ± (0.8% reading + 3) 200V 0.1V 600V 1V ± (1.0% reading + 5) Input impedance: 10MΩ. Maximum input voltage: DC or AC 600V RMS. Frequency range: 40Hz~400Hz DC Current 20mA 0.01mA 200mA 0.1mA ± (1.8% reading + 5) Input protection: FF250mA/600V fuse. AC Current 20mA 0.01mA 200mA 0.1mA ± (2.0% reading + 5) Input protection: FF250mA/600V fuse. 7

Resistance 200Ω 0.1Ω 2kΩ 0.001kΩ 20kΩ 0.01kΩ ± (1.0% reading + 3) 200kΩ 0.1kΩ 2MΩ 0.001MΩ 20MΩ 0.01MΩ ± (1.2% reading + 15) Input protection: Maximum DC or AC 600V RMS Input protection: Maximum DC or AC 600V RMS. CLEANING & MAINTENANCE Diode Function Range Resolution Test Environment Diode test 1V 0.001V Testing current: about 1mA; open circuit voltage: about 2.8V. The display will show the approximate value of the diode forward voltage drop. Buzzer On/Off Function Description Test Environment When the built-in buzzer sounds, the measured resistance is no more than about 50Ω. Input protection: Maximum DC or AC 600V RMS. Testing current: about 1mA; open circuit voltage: about 2.8V. Clean the outer cabinet of the instrument with a clean, damp cloth and a small amount of mild detergent. Do not use any chemicals, abrasives or solvents that could damage the meter. REPLACING THE BATTERIES Turn off the power supply and disconnect the probe from the Loosen the screws used for fixing the battery cover and remove the battery cover. Remove the old batteries and replace with new ones. Mount the battery cover and and tighten the screws. RECYCLING INFORMATION This symbol indicates that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. Made in China. PR2 9PP 8 V 1.0