Pulse Sequence Design Made Easier

Similar documents
Pulse Sequence Design and Image Procedures

Principles of MRI EE225E / BIO265. Lecture 21. Instructor: Miki Lustig UC Berkeley, EECS. M. Lustig, EECS UC Berkeley

Pulse Sequences: Rapid Gradient Echo

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

H 2 O and fat imaging

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

Background (~EE369B)

MR Basics: Module 6 Pulse Sequences

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

MRI Anatomy and Positioning Series Module 12: Fat Suppression Techniques

MRI Summer Course Lab 2: Gradient Echo T1 & T2* Curves

Advanced MSK MRI Protocols at 3.0T. Garry E. Gold, M.D. Associate Professor Department of Radiology Stanford University

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

MR Advance Techniques. Flow Phenomena. Class II

MR Basics: Module 8 Image Quality

1 Introduction. 2 The basic principles of NMR

Steady-state sequences: Spoiled and balanced methods

RAD 229: MRI Signals and Sequences

functional MRI: A primer

HETERONUCLEAR IMAGING. Topics to be Discussed:

(N)MR Imaging. Lab Course Script. FMP PhD Autumn School. Location: C81, MRI Lab B0.03 (basement) Instructor: Leif Schröder. Date: November 3rd, 2010

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

MRI Metal Artifact Reduction

Image Quality/Artifacts Frequency (MHz)

2015 Spin echoes and projection imaging

MAGNETIC RESONANCE IMAGING

MRI at a Glance. Catherine Westbrook. Blackwell Science

Chapter 2. The Physics of Magnetic Resonance Imaging

2014 M.S. Cohen all rights reserved

BOLD fmri: signal source, data acquisition, and interpretation

IR/SR TrueFISP. Works-in-Progress package Version 1.2. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B.

Page 1 of 9. Protocol: adult_other_adni3_study_human_ge_3t_25w_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

NMR Basics. Lecture 2

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

Simultaneous Multi-Slice (Slice Accelerated) Diffusion EPI

Half-Pulse Excitation Pulse Design and the Artifact Evaluation

MR in Tx Planning. Acknowledgements. Outline. Overview MR in RTP

Index COPYRIGHTED MATERIAL. Note: Page number followed by italics are for figures and bold are for tables, respectively.

Gradients. Effects of B0 gradients on transverse magnetisation Similar to figure 10 of Sattler review Progr. NMR 34 (1999), 93

MARP. MR Accreditation Program Quality Control Beyond Just the Scans and Measurements July 2005

A. SPECIFIC AIMS: phase graph (EPG) algorithms to cover a wide range of MRI

Lab 8 6.S02 Spring 2013 MRI Projection Imaging

System/Imaging Imperfections

Works-in-Progress package Version 1.0. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B. January 22, 2003

Improve Image Quality of Transversal Relaxation Time PROPELLER and FLAIR on Magnetic Resonance Imaging

Magnetic Resonance Imaging Principles, Methods, and Techniques

PHY3902 PHY3904. Nuclear magnetic resonance Laboratory Protocol

ISSN X CODEN (USA): PCHHAX. The role of dual spin echo in increasing resolution in diffusion weighted imaging of brain

RF pulse design and the Small Tip Angle Approximation

Magnetic Resonance Imaging

Mapping the Flip Angle in Magnetic Resonance Imaging Using the Accelerated 3D Look-Locker Sequence

CME. Rapid Gradient-Echo Imaging. Review. Brian A. Hargreaves, PhD*

Challenges of Field Inhomogeneities and a Method for Compensation. Angela Lynn Styczynski Snyder. Michael Garwood, Ph.D., Adviser

In a typical biological sample the concentration of the solute is 1 mm or less. In many situations,

MRI: From Signal to Image

High Field MRI: Technology, Applications, Safety, and Limitations

RF Pulse Toolkit: Application Specific Design

ACRIN 6686 / RTOG 0825

Downloaded from by on 02/07/18 from IP address Copyright ARRS. For personal use only; all rights reserved

Noninvasive Blood Flow Mapping with Arterial Spin Labeling (ASL) Paul Kyu Han and Sung-Hong Park

The promise of high-field MRI. High Field MRI Technology, Applications, Safety, and Limitations. High-field Scanners

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 July 21.

FAST AND CONTRAST-ENHANCED PHASE-SENSITIVE MAGNETIC RESONANCE IMAGING

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

Steady-state MRI: methods for neuroimaging

k y 2k y,max k x 2k x,max

Improvement of the Image Quality of Black-blood Magnetic Resonance Imaging with the Subtraction Double Inversion Recovery Technique

Lecture 7: Basics of magnetic resonance imaging (MRI): one dimensional Fourier imaging

A Conceptual Tour of Pulsed NMR*

SIEMENS MAGNETOM Skyra syngo MR D13

EE225E/BIOE265 Spring 2012 Principles of MRI. Assignment 7. Due March 16, 2012

MRI MRI REGISTRY REVIEW PHYSICAL PRINCIPLES OF IMAGE FORMATION ARTIFACTS SUPERCONDUCTIVE MAGNET ANAIBI MOLINA(R) (RT) (MR) (CT) T2 DEPHASING

NUMERICAL DESIGN OF RESONATOR COILS FOR HIGH FIELD MAGNETIC RESONANCE IMAGING. A Thesis

1.5T HIGH FIELD SMALL ANIMAL MRI

Diffusion and Functional MRI of the Spinal Cord Methods and Clinical Applications

Microneurography in conjunction with functional Magnetic Resonance Imaging Technical Issues and Signal Processing

MRI imaging in neuroscience Dr. Thom Oostendorp Lab class: 2 hrs

Chapter 11 Coherence Editing: Pulse-field Gradients and Phase Cycling

Application Guide & Release Notes

Inherent Insensitivity to RF Inhomogeneity in FLASH Imaging

NEMA Standards Publication MS (R2014) Determination of Signal-to-Noise Ratio (SNR) in Diagnostic Magnetic Resonance Imaging

Fast Joint design of RF and Gradient waveforms for MRI parallel excitation

Optimizing the Magnetization-Prepared Rapid Gradient-Echo (MP-RAGE) Sequence

SIGNA Explorer Lift revives our MR

3T Unlimited. ipat on MAGNETOM Allegra The Importance of ipat at 3T. medical

Ultrasonic Linear Array Medical Imaging System

3D-Printed Microstrip Resonators for 4.7T MRI. Saeed Javidmehr. A thesis submitted in partial fulfillment of the requirements for the degree of

PULSED/CW NUCLEAR MAGNETIC RESONANCE

Digital Imaging CT & MR

TimTX TrueShape. The parallel transmit architecture of the future. Answers for life.

Applications Guide. Spectral Editing with SVS. (Works-in-Progress) MAGNETOM TaTs and Verio Systems (3T)

Spiral MRI on a 9.4T Vertical-bore Superconducting Magnet Using Unshielded and Self-shielded Gradient Coils

Efficiency of Background Suppression for Arterial Spin Labeling. Dairon Garcia

6.S02 MRI Lab Acquire MR signals. 2.1 Free Induction decay (FID)

Optimization of Gradient-Echo MR for Calcium Detection

Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging

EE225E/BIOE265 Spring 2014 Principles of MRI. Assignment 6. Due Friday March 7th, 2014, Self Grading Due Monday March 10th, 2014

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

Passive Tracking Exploiting Local Signal Conservation: The White Marker Phenomenon

Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

Transcription:

Pulse Sequence Design Made Easier Gregory L. Wheeler, BSRT(R)(MR) MRI Consultant gurumri@gmail.com 1 2 Pulse Sequences generally have the following characteristics: An RF line characterizing RF Pulse applications A pulse sequence is a timing diagram designed with a series of RF pulses, gradients switching, and signal readout used in MR image formation. Pulse Sequence Design Made Easier Gradients switching to encode the volume for spatial localization Signal reception used to create MR image Pulse sequence components 3 4 There are four processes in pulse sequence design: Excitation RF pulse(s) is/are applied Encoding Phase encoding is performed to determine how K-space is filled Refocusing Refocusing Net Magnetization back into transverse plane Readout Signal is encoded and recorded This is a timing diagram. All lines are read left to right and top to bottom simultaneously. Above line is positive direction. Below line is negative direction. The RF line characterizes RF pulse applications. The height and width of the pulse determines how much (watts) and how long the pulse is applied. Gradients are switched on and off to spatially localize the volume or the slice for image reconstruction. Gradients are switched on and off for: Slice Selection Phase Encoding Frequency Encoding or Readout Pulse sequence processes 5 Pulse Sequence Guidelines 6 Page 1

The gradient on while the RF is applied is the Slice Select Gradient. The gradient on while the signal is received or recorded is the Frequency Encoding or Readout Gradient. Which gradient is the slice select gradient?? The gradient that changes amplitude per TR and on prior to refocusing is the Phase Encoding Gradient. Pulse Sequence Guidelines Pulse Sequence Quiz 7 8 Which gradient is the slice select gradient? Gz Which gradient is the slice select gradient? Gz Which gradient is the phase encoding gradient?? Pulse Sequence Quiz Pulse Sequence Quiz 9 10 Pulse Sequence Quiz Which gradient is the slice select gradient? Gz Which gradient is the phase encoding gradient? Gy Pulse Sequence Quiz Which gradient is the slice select gradient? Gz Which gradient is the phase encoding gradient? Gy Which gradient is the frequency encoding gradient?? 11 12 Page 2

Pulse Sequence Quiz Which gradient is the slice select gradient? Gz Which gradient is the phase encoding gradient? Gy Which gradient is the frequency encoding gradient? Gx 13 14 What slice orientation will the images created from this pulse sequence have? 15 What slice orientation will the images created from this pulse sequence have? AXIALS (Gz - is the slice select gradient) 16 More on Phase Encoding Phase encoding is performed to provide spatial localization and to guide k-space filling. What do you notice about the phase encoding gradient? Phase amplitude changes every TR 17 18 Page 3

Each amplitude designates another line in k-space 19 What do you notice about the signal as gradient changes? 20 Signal gets stronger with low amplitude gradients (shallow). The signal gets weaker with high amplitude gradients (steeper). Outer lines of K-space, use high amplitude gradients which yield low signal return. Center lines of K-space use low amplitude gradients which yield high signal return. Outer lines reconstructed yield spatial resolution. Center lines reconstructed yield signal (S/N) and contrast. 21 22 High Spatial Resolution High S/N and Contrast High Spatial Resolution Frequency Encoding K-Space Filling 23 24 Page 4

There are three conventional pulse sequence designs. Spin Echo Gradient Recalled Echo Inversion Recovery Spin Echo pulse sequences begin with a 90 RF pulse followed by at least one 180 RF pulse. Produces T1-, T2-, and PD-wt. type tissue contrast Conventional Pulse Sequences Spin Echo Pulse Sequence (SE) 25 26 Image parameters Short TR - contrast Short TE - signal Image Contrast Bright Fat - short T1 Dark CSF - long T1 Image Parameters Long TR - signal Short TE - signal Image Contrast Bright or Gray Fat Gray CSF Contrast based on proton concentration SE T1-weighted SE Double Echo Proton Density Image Parameters Long TR - signal Long TE - contrast RF 90 180 180 echo echo 90 Image Contrast Dark Fat short T2 Bright CSF Long T2 Gss Gpe Gro TR TE 1 TE 2 SE Double Echo T2-weighted Conventional Spin Echo Diagram 30 Page 5

Which two processes are repeated in a Dual SE Sequence? Which two processes are repeated in a Dual SE Sequence? Refocusing and Readout Tau Time 33 34 Effects of the 180 0 Pulse eliminates signal loss due to field inhomogeneities eliminates signal loss due to susceptibility effects eliminates signal loss due to water/fat dephasing all signal decay is caused by T2 relaxation only Spin Echo Parameters T1 is TR Dependent PD is TR and TE Dependent T2 is TE Dependent Spin Echo Parameters that manipulate Tissue Characteristics 35 36 Page 6

Multi Echo Spin Echo RF only 1 phase encode per TR ST = TR(msec) x Npe x NEX /60,000(msec) slice ST: Scan time in minutes Npe: Number of phase steps NEX: Number of acquisitions, NAQ, NEX, NSA phase readout 2DFT Scan Time Formula signal 37 echo 1 echo 2 38 38 R F 90 180 echo 180 echo First developed as the RARE (Rapid Acquisition with Relaxation Enhancement) method. 192 192 A 90 pulse initiates the sequence, followed by multiple 180 pulses to generate multiple echoes. 4 3 2 1 Frequency Encoding Frequency Encoding 4 3 2 1 However separate phase encodes are used prior to each echo to fill k-space more rapidly. Fast Spin Echo 39 40 Fast Spin Echo Pulse Diagram 41 42 Page 7

Parameter Acronyms ETE ETL or Turbo Factor ETS Terminology Effective TE The TE placed in portion of k-space with greatest impact on signal. Echo Train Length Number of Echoes acquired per TR Echo Train Spacing Time (msec) between echoes in Echo Train Fast Imaging Parameters 43 ETE Selectable and determines TE in center of k- space. Therefore determines image contrast. ETL Selectable and determines number of echoes acquired per TR. Determines how fast sequence is run; higher the ETL the shorter the scan time. Higher ETL reduce time for slices. ETS Not selectable; higher spacing leads to blurriness. Fast Imaging Parameters 44 Optimal TR is 2000 4000msec or longer so magnetization fully recovers. Longer TR s allow more signal and slices. Shorter TR (<2000msec) image not T2- weighted even though CSF is bright. Too much T1 contrast added to the image. ETE time is long >80msec. Longer ETE s are allowed due to longer TR (signal) Fast or Turbo SE Guidelines Single shot FSE or TSE acquires 53% of k- space and reconstructs in Half-Fourier algorithm to achieve final resolution. Allows T2-wt studies with reduced motion artifacts and low susceptibility. Adaptable for breath hold exams and uncooperative patients. Single Shot FSE concept 46 SE & FSE Contrast Parameter Guidelines Scan Time = TR(msec) x Npe x NEX (Minutes) 60,000(msec) x ETL TE TR WEIGHTING short short T1 long long T2 short long Proton density Fast Imaging Scan Time Formula 47 48 Page 8

Spin Echo All vendors use Spin Echo designation Fast Imaging T2 Siemens: Turbo Spin Echo GE: Fast Spin Echo Hitachi: Fast Spin Echo Philips: Turbo Spin Echo Picker: Fast Spin Echo Toshiba: Fast Spin Echo Vendor Terminology Single Shot SE Siemens: HASTE GE: SSFSE Hitachi: SSFSE Philips: SSTSE Picker: EXPRESS Toshiba: FASE FSE w/90 Flip-Back Siemens: RESTORE GE: FRFSE Hitachi: Driven Equilibrium Philips: DRIVE Toshiba: FSE T2 puls 49 50 Inversion Recovery Sequence Inversion Spin Echo Diagram 51 52 Inversion Recovery pulse sequences are highly sensitive to differences in T1 values of tissues. Especially useful where T1 values are similar. The primary contrast control mechanism is TI. TI, Time of Inversion, is the length of time net magnetization is allowed to recover before starting the 90 RF pulse (Spin Echo). STIR, Short TI or Tau Inversion Recovery, sequences are created by shortening the TI time to 69% of T1 relaxation of fat for fat suppression. FLAIR, Fluid Attenuated Inversion Recovery, sequences are created by lengthening the TI time to 69% of T1 relaxation of water for water suppression. Inversion Recovery 53 54 Page 9

The effect of inverting the magnetization vector by the 180 RF pulse allows for the tissues dynamic range to be increased. The magnitude of magnetization M is a function of time after a 180 pulse. Magnetization starts negative (-Z), passes through zero at t =.69 T1 and recovers completely by t = 5T1. Suppression occurs at the tissue s NULL POINT. Null point is the point at which net magnetization crosses the transverse plane. The Null point is approximately 69% of the T1 of the tissue to be suppressed. Inversion Recovery Null Point Suppression Point 55 56 Desired Contrast Inversion Time (TI) Heavily T1-wt STIR (Fat Suppressed) TI is approx. ¼ TR 85 250msec Null Points FLAIR (Water Suppressed) 1900-2500msec IR Parameter Guidelines 57 58 TE long TR long 50-80msec 4000 10,000msec ETL 16 20 TI null point of fat T2 FSE and T2 STIR STIR Parameter Guidelines 59 60 Page 10

STIR should not be used with contrast because STIR will suppress both the fat and the contrast. Useful in MSK imaging normal bone is fatty marrow bone bruises and fractures are clearly seen. STIR Imaging Guidelines STIR Images - MSK 61 62 Helps visualize stroke. Helps in determining Multiple Sclerosis Achieves suppression of CSF. Long TE, Long TR, Long ETL TI/TAU time of 1700 3200msec (depending on magnetic field strength) Used in brain and cord imaging see periventricular and cord lesions more clearly Fluid Attenuated IR Fluid Attenuated IR Parameters 63 64 FLAIR Axial Brain 65 66 Page 11

Gradient Recalled Echo Diagram (Static) 67 Gradient Recalled Echo Diagram (Dynamic) 68 In Gradient Recalled Echo, a reversed gradient technique refocuses the spin phases. Flip angles less than 90 are optimized to enhance T1 or T2 tissue-like contrast (T2*). Flip angles less than 90, flip some component of longitudinal magnetization vector into the transverse plane, while portions remain. Gradient Recalled Echo (GRE) Gradient Echo sequences show a wide range of variations compared to the Spin Echo and Inversion Recovery sequences. 69 70 The major benefit is the use of the gradients to refocus the net magnetization instead of an RF pulse. A gradient reversal in the readout direction is used to create the echo. Spins will either speed up or slow down pending the gradient influence. This is different from the 180 RF pulse which flips the spins for refocusing. Gradient Reversal The spins are refocused by reversing the speed of the spins rather than flipping them over to the other side of the x-y plane as occurs with the spin echo sequence. Magnetic susceptibility artifacts are more pronounced on gradient echo sequences. 71 72 Page 12

Magnetic Susceptibility Magnetic susceptibility, caused by protons of one tissue precessing faster than the protons of an adjacent tissue, is exaggerated due to the affect the spins have on each other while under the influence of the reversed gradient. The MR signal returned is due primarily to T1 longitudinal magnetization. The MR signal returned is also due to faster T2 relaxation rates due to field inhomogeneities. The information is therefore T2* information, which is T2 relaxation due to magnetic field inhomogeneities as well as tissue characteristics. Gradient Recalled Echo (GRE) 73 74 short FA medium FA long FA T2*-weighted PD-weighted T1-weighted Flip Angle Degree Range Contrast Short 1-35 T2* Medium 36-59 PD Long 60-90 T1 Flip Angles Flip Angles control GRE Contrast 75 76 Spoiled GRE Incoherent aka SPGR, FLASH, T1-FFE Uses gradients or RF to spoil or destroy accumulated transverse coherence maximizes T1 contrast Refocused GRE Coherent Aka FISP, GRASS, FFE, Rephased SARGE Uses RF or gradients to refocus accumulated transverse magnetization Maximizes T2 Contrast Gradient Recalled Echo Gradient Recalled Echo 77 78 Page 13

A Fast GRE sequence generates gradient echoes very rapidly using similar fast imaging techniques to fill k-space. Image contrast cannot be controlled with the flip angle, TR, and TE. Rather, a preparation pulse (TI) creates the desired contrast. The sequence is initiated with the 180 preparation pulse followed by a waiting period (the inversion time). R F Gss Gro Gpe 1 phase encode/tr echo TE TR Spoiler Pulses Inversion times of 200 to 1000msec are used. Fast Gradient Echo Conventional GRE w/ Spoilers 79 80 R F 180 echo echo R F 180 Gss Gro Gpe 180 Inversion Time ~200-1000 ms TR ~9-13 ms TE ~3-6 ms Inversion Time R F Data Acquisition Window Fast GRE Pulse Diagram Fast GRE Pulse Diagram 81 82 More on GRE.. MR signal is a composite of fat and water in the imaging voxel. Water and fat resonate at slightly different frequencies. TE time will determine whether fat and water will appear inphase or out-of-phase. Field Strength (T) 0.5 1 1.5 W-F Offset (Hz) 75 150 225 in 0.00 0.00 0.00 out 6.71 3.36 2.24 in 13.42 6.71 4.47 out 20.13 10.07 6.71 in 26.84 13.42 8.95 out 33.55 16.78 11.18 in 40.26 20.13 13.42 out 46.97 23.49 15.67 in 53.68 26.94 17.89 out 60.39 30.33 20.13 in 67.10 33.74 22.37 out 73.81 37.14 24.60 in 80.52 40.55 26.84 83 84 Page 14

Field Strength (T) 0.5 1 1.5 W-F Offset (Hz) 75 150 225 in 0.00 0.00 0.00 out 6.71 3.36 2.24 in 13.42 6.71 4.47 out 20.13 10.07 6.71 in 26.84 13.42 8.95 out 33.55 16.78 11.18 in 40.26 20.13 13.42 out 46.97 23.49 15.67 in 53.68 26.94 17.89 out 60.39 30.33 20.13 in 67.10 33.74 22.37 out 73.81 37.14 24.60 in 80.52 40.55 26.84 Frequency difference in ppm Fat frequency minus water frequency divided by the water frequency equals the frequency difference. This difference is about 3.3-3.5ppm. Frequency difference in hertz Multiply 3.5ppm by the imaging system s operating frequency. SI Fat water 85 frequency 86 Quiz Determine the frequency difference between fat and water at 3.0T? Hints: To find the operating frequency you must use the Larmor equation ώ = γ x β Multiply 3.5ppm by the imaging system s operating frequency to find the frequency difference. Fat/Water difference in hertz Answer: 1 st : Larmor Equation: ώ = γ x β ώ = 42.58mHz x 3.0T ώ = 127.74 mhz 2 nd : 3.5ppm x operating frequency 3.5ppm x 127.74mHz = 447 Hz @3.0T 0.35T 14.90 mhz x 3.5ppm = 52.1 Hz 1.5T 63.86 mhz x 3.5ppm = 223 Hz 87 88 Gradient Echo Vendor Acronyms Out of Phase Sequence Siemens GE Philips Hitachi Toshiba Picker Spoiled GE FLASH SPGR T1-FFE RSSG FE T1 Fast Coherent GE FISP GRASS FFE Re-SARGE FE In-phase SSFP TrueFISP FIESTA T2-FFE SARGE True SSFP CE Fast UltraFast TurboFLASH FastSPGR TFE RGE Fast GE RF Fast UltraFast 3D MPRAGE 3D FastSPGR 3DTFE MPRAGE 89 90 Page 15

Thanks for sharing your time with me! 91 92 Page 16