Keysight N2771B 30 kv High Voltage Probe

Similar documents
Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

Keysight N2790A Differential Voltage Probe. User Guide

PKT 512A-RO High Impedance Passive Cable Divider

Keysight U9397A/C FET Solid State Switch (SPDT)

400 MHz Passive High-Voltage Probe R&S RT-ZH

PHV RO High Voltage Passive Probe. Instruction Manual

Keysight 86205B RF Bridge

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP017 and PP018 Passive Probes

TA MHz oscilloscope probe TA MHz oscilloscope probe

N2790A Differential Voltage Probe

Keysight U2701A/U2702A USB Modular Oscilloscope

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

1157A 2.5 GHz Active Probe

1156A 1.5 GHz Active Probe

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Agilent 1146A AC/DC Oscilloscope Current Probe

Keysight 16440A SMU/Pulse Generator Selector

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Tablet Oscilloscope Safety Information

Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy

Operator s Manual. PP016 Passive Probe

TETRIS User's Guide. High Impedance Active Probe DO177-1

N2792A and N2793A Differential Probes User s Guide

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide

1147A 50 MHz Current Probe

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Agilent G1888 Network Headspace Sampler

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Agilent 1147A 50 MHz Current Probe

Agilent N2893A 100 MHz Current Probe

Agilent 1160 Series Miniature Passive Oscilloscope Probes. User s Guide

200Amp AC Clamp Meter + NCV Model MA250

Keysight N7026A 150 MHz AC/DC High Sensitivity Current Probes. User s Guide

InfiniiMax Spice Models for the N5381A and N5382A Probe Heads

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

Keysight X-Series Signal Analyzer

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Keysight 1147B 50 MHz Current Probe. User s Guide

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DM-45 Digital Multimeter

2015 RIGOL TECHNOLOGIES, INC.

Keysight U7243B USB3.1 Electrical Compliance Test Application. Methods of Implementation

TT-SI MHz Active Differential Probe

SPM-50 RF Spectrum Power Meter PC Software User Manual

TT-SI MHz DIFFERENTIAL PROBE

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

TT-SI 9001 / TT-SI MHz Active Differential Probes

Keysight U1211A, U1212A, and U1213A Clamp Meters

Keysight 8710x Series Coaxial Multiport Switches

Keysight 8494/95/96G/H Attenuators

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Educator s Training Kit for 1000 X-Series Oscilloscopes

Agilent 8494/95/96A/B Attenuators

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

DS1000E, DS1000D Series Digital Oscilloscope

AC/DC CLAMP METER USER S MANUAL

ELECTROSURGICAL UNIT ANALYZER

Choosing the right Pico Technology active differential probe

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Keysight X-Series Signal Analyzers

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

Pin Tool. Assembly Guide. For Research Use Only. Not for use in diagnostic procedures. Original Instructions

USER'S MANUAL DMR-6700

MODEL 3810/2 Line Impedance Stabilization Network

Agilent N6700 Modular Power System Family

netzerotools.com 374/375/376 Users Manual Clamp Meter

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

80i-110s AC/DC CURRENT PROBE

Keysight Technologies E4416A/4417A Power Meters

User s Manual Current Probe. IM E 2nd Edition IM E

Model 228 Current Leakage Tester INSTRUCTION MANUAL

Agilent N6700 Modular Power System Family

Keysight Advanced Power System N6900/N7900 Series

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Keysight U7250A MIPI C-PHY SM Compliance Test Application. Methods of Implementation

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

Model MHz Arbitrary Waveform / Function Generator

VT1586A Rack Mount Terminal Panel Installation and User s Manual

INSTRUCTION MANUAL CLAMP ON PROBE

TT-SI MHz Active Differential Probe

User s Guide. 400A AC/DC Clamp Meter. Model MA220

1.General instructions Specifications Description...7

Keysight 3458A Multimeter

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Model 229 Series 2 Leakage Current Tester OPERATOR S MANUAL

312, 316, 318. Clamp Meter. Users Manual

Transcription:

Keysight N2771B 30 kv High Voltage Probe User s Guide

Notices Keysight Technologies, Inc. 2012-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number N2771-92011 Ed ition Fourth edition, August 2015 Printed in Germany Keysight Technologies Malaysia Sdn. Bhd. Bayan Lepas Free Industrial Zone 11900 Penang, Malaysia Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Keysight disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Keysight shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Keysight and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hard ware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. U.S. Government Rights The Software is "commercial computer software," as defined by Federal Acquisition Regulation ("FAR") 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement ("DFARS") 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at www.keysight.com/find/sweula. The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indicated conditions are fully understood and met. A notice denotes a hazard. It calls attention to an operating proced ure, practice, or the like that, if not correctly performed or adhered to, could resul t in personal injury or death. Do not proceed beyond a notice until the ind icated cond itions are fully understood and met.

Introduction Introduction The Keysight N2771B High Voltage Divider Probe is an accessory to be used with analog or digital oscilloscopes having input resistance of 1 MΩ (±1%) and nominal input capacitance between 6 and 20 pf. The N2771B is a 1000:1 divider which extends the voltage measurement capability to 15 kv DC, 10 kv rms AC, or 30 kv peak (< 20 ns pulse width). Contents Safety Precautions 4 IEC Measurement Category Definitions 6 Operation 7 Frequency Compensation Adjustment 8 Cleaning 8 Characteristics 9 Contacting Keysight 11 3

Safety Precautions Safety Precautions This high vol tage probe is designed to prevent accidental shock to the operator when properly used. This operating note must be read and understood prior to using the probe. Improper procedures or incorrect analysis of the measurement situation can resul t in serious shock. If the probe is subjected to vol tages over 15kV DC, or 10 kv rms, or 30 kv peak then DO NOT USE. The probe could potentially be damaged. Return the probe immed iately to a Keysight service center for performance validation. This high vol tage probe is designed for use within Measurement Category I (CAT I) only. Do not use the probe for measurements performed on circuits defined by any other measurement category or transient overvol tages of more than 1500V. Refer to IEC Measurement Category Definitions" on page 6 for a definition of measurement categories. Do not exceed 60 seconds of contact between the probe and circuit-under-test when measuring vol tages 8kV (DC), 5kV (AC, rms), or 20 kv (AC, peak). Keysight recommend s that an interval of 5 minutes be taken between measurements. This high vol tage probe must only be used by personnel who are trained, experienced, or otherwise qualified to recognize hazardous situations and who are trained in the safety precautions that are necessary to avoid possible injury when using such a device. Do not work alone when working with high vol tage circuits. For your own safety, inspect the probes for cracks and frayed or broken leads before each use. If defects are noted, DO NOT use the probe. Hands, shoes, floor and work bench must be dry. Avoid making measurements under humid, damp or other environmental cond itions that might effect the safety of the measurement situation. It is ad visable to turn the high vol tage source off before connecting or d isconnecting the probe. The probe body should be kept clean and free of any cond uctive contamination. Refer to the section on cleaning. 4

Safety Precautions The ground lead is critical to the safe operation of the probe. Failure to make this connection when making high vol tage measurements may resul t in personal injury or damage to the probe or oscilloscope. This connection must al ways be made BEFORE the probe tip comes in contact with the high vol tage and must not be removed until the probe tip has been removed from the high vol tage source. Do not attempt to take measurements from sources where the chassis or return lead is not grounded. 5

IEC Measurement Category Definitions IEC Measurement Category Definitions Measurement Category I (CAT I) Measurement Category II (CAT II) Measurement Category III (CAT III) Measurement Category IV (CAT IV) Definitions and Examples (Clause 6.5.2). Measurement category I is for measurements performed on circuits not directly connected to a mains supply. Example Measurements in circuits not derived from a mains supply and specially protected (internal) circuits derived from a mains supply. In the latter case, transient stresses are variable. For that reason, it is required that the transient withstand capability of the equipment is made known to the user. Measurement category II is for measurements performed on circuits directly connected to the low voltage installation. Example Household appliances, portable tools, and similar equipment. Measurement category III is for measurements performed in the building installation. Example Measurements on distribution boards, circuit breakers, wiring including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation and equipment for industrial use like, for example, stationary motors with permanent connections to the fixed installation. Measurement category IV is for measurements performed at the source of the low-voltage installation. Example Electricity meters and measurements on primary over-current protection devices and ripple control units. 6

Operation Operation 1 Connect the probe to the BNC input of the oscilloscope. 2 Select the desired volts/division range. (If you can set probe attenuation on the oscilloscope, set it to 1000:1) 3 Whenever possible, turn the high voltage source off before making any connections. 4 Connect the divider probe ground lead (alligator clip) to a good earth ground or reliable chassis ground. 5 Before turning on the high voltage source, make sure that no part of the person holding the probe is touching the device under test. Once this is certain, turn on the high voltage source. 6 Measure the voltage under test and observe the waveform on the oscilloscope. Remember the actual voltage is 1000 times greater than the oscilloscope waveform if the probe attenuation has not been set to 1000:1. 7 Turn off the high voltage source. 8 Disconnect the Keysight N2771B High Voltage Probe from the high voltage source BEFORE disconnecting the ground clip lead. Do not attempt to take measurements from sources where the chassis or return lead is not grounded. The ground lead is critical to the safe operation of the probe. Failure to make this connection when making high vol tage measurements may resul t in personal injury or damage to the probe or oscilloscope. This connection must al ways be made BEFORE the probe tip comes in contact with the high vol tage and must not be removed until the probe tip has been removed from the high vol tage source. Do not connect the ground clip lead to the high vol tage source for any reason. Do not make any floating measurements with the Keysight N2771B High Vol tage probe. Do not exceed 60 seconds of contact between the probe and circuit-under-test when measuring vol tages 8kV (DC), 5kV (AC, rms), or 20 kv (AC, peak). Keysight recommend s that an interval of 5 minutes be taken between measurements. This high vol tage probe is designed for use within Measurement Category I (CAT I) only. Do not use the probe for measurements within the other measurement categories or transient overvol tages of more than 1500V. 7

Frequency Compensation Adjustment Frequency Compensation Adjustment The N2771B High Voltage Probe has a Frequency Compensation adjustment that compensates for the input capacitance of the oscilloscope being used with the probe. Use a square-wave generator set for approximately 100 Hz output. Proceed with the following steps for frequency compensation. 1 Connect the probe to the oscilloscope. 2 Connect probe tip to square-wave generator. 3 Adjust the square wave generator for approximately 10 volts amplitude. 4 Adjust the oscilloscope time base for 20 μs/div. 5 Use a trimmer tool to adjust the compensation capacitor for the flattest pulse top. See the figure below for the location of the adjustment. Figure 1 Location of Frequency Compensation Adjustment Cleaning Clean only the exterior probe body and cables. Use a soft cotton cloth lightly moistened with a mild solution of detergent and water. Do not allow any portion of the probe to be submerged at any time. CAUTION Dry the probe thoroughly before attempting to make vol tage measurements. Do not subject the probe to solvents or solvent fumes as these can cause deterioration of the probe body and cables. 8

Characteristics Characteristics Table 1 Characteristics (Not Warranted) Maximum Input Vol tage (CAT I) DC Voltage: 15 kv AC Voltage: 10 kv rms Peak Voltage: 30 kv peak (< 20 ns pulse wid th) Compensation Range Temperature Coefficient Less than 200 ppm/ C Division Ratio For input capacitance of 6 pf to 20 pf 1000:1 Band wid th Designed For Use In 50 MHz ( 3 db) POLLUTION DEGREE 2 Input Resistance Operating Temperature 100 MΩ, when terminated by 1 MΩ 0 C to +50 C Cable Length: Storage Temperature: 2 meter 20 C to +70 C Al titude: Humidity Up to 2,000 meters (6,561 ft) Up to 80% relative humidity at +40 C Accuracy: DC Volts: ±2, 5% (below 10 kv) DC Volts: ±4% (between 10 kv and 15 kv) AC Volts: ±5% at 1 khz AC Volts: ±3 db between 1 khz and 50 MHz 9

Voltage Derating Voltage Derating The following graph shows the voltage versus frequency derating curve for the Keysight N2771B High Voltage Probe. Figure 2 Voltage Versus Frequency Derating Curve 10

Contacting Keysight Contacting Keysight Information on contacting Keysight Technologies can be found at: www.keysight.com/find/contactus 11

Manual Part Number N2771-92011 *N2771-92011* Printed in Germany Keysight Technologies Malaysia Sdn. Bhd. Bayan Lepas Free Industrial Zone 11900 Penang, Malaysia