A Study of Magnetic Shielding Performance of a Fermilab International Linear Collider Superconducting RF Cavity Cryomodule

Similar documents
MAGNETIC HYGIENE CONTROL ON LCLS-II CRYOMODULES FABRICATED AT JLAB*

ACHIEVEMENT OF ULTRA-HIGH QUALITY FACTOR IN PROTOTYPE CRYOMODULE FOR LCLS-II

THE ROLE OF MAGNETIC FLUX EXPULSION TO REACH Q0>3x10 10 IN SRF CRYOMODULES

Superconducting RF Cavity Performance Degradation after Quenching in Static Magnetic Field

CAGE CAVITY: A LOW COST, HIGH PERFORMANCE SRF ACCELERATING STRUCTURE*

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

NIOBIUM IMPURITY-DOPING STUDIES AT CORNELL AND CM COOL-DOWN DYNAMIC EFFECT ONQ 0

Overview of ERL Projects: SRF Issues and Challenges. Matthias Liepe Cornell University

Snowmass WG5: Superconducting Cavities and Couplers (Draft August 12, 2005 Rong-Li Geng) Topic 1: Cavity Shape

HIGH POWER COUPLER FOR THE TESLA TEST FACILITY

Resonant Excitation of High Order Modes in the 3.9 GHz Cavity of LCLS-II Linac

Packaging of Cryogenic Components

MRI SYSTEM COMPONENTS Module One

ASSEMBLY PREPARATIONS FOR THE INTERNATIONAL ERL CRYOMODULE AT DARESBURY LABORATORY

THE CRYOGENIC SYSTEM OF TESLA

RF thermal and new cold part design studies on TTF-III input coupler for Project-X

Vibration studies of a superconducting accelerating

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

Cornell ERL s Main Linac Cavities

LCLS-II SRF Linac Multi-lab partnership to build CW FEL based on SRF at SLAC. Marc Ross 13 January 2014

LOW BETA CAVITY DEVELOPMENT FOR AN ATLAS INTENSITY UPGRADE

5.5 SNS Superconducting Linac

TECHNICAL CHALLENGES OF THE LCLS-II CW X-RAY FEL *

To produce more powerful and high-efficiency particle accelerator, efforts have

(fb) Nevent/year for 50fb -1. s (GeV) ~ ~ qq q=t. ZZ cos <0.8 W + W tt 175GeV 500,00 5,000. Zh 120GeV. 230GeV. HA 400GeV 220GeV 410GeV

Novel Demagnetization Method after Magnetic Particle Testing

COMPARISON OF BUFFERED CHEMICAL POLISHED AND ELECTROPOLISHED 3.9 GHz CAVITIES*

RECORD QUALITY FACTOR PERFORMANCE OF THE PROTOTYPE CORNELL ERL MAIN LINAC CAVITY IN THE HORIZONTAL TEST CRYOMODULE

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT

COUPLER DESIGN CONSIDERATIONS FOR THE ILC CRAB CAVITY

DESIGN OF SINGLE SPOKE RESONATORS FOR PROJECT X*

Experience with 3.9 GHz cavity HOM couplers

XFEL Cryo System. Project X Collaboration Meeting, FNAL September 8-9, 2010 Bernd Petersen DESY MKS (XFEL WP10 & WP13) 1 st stage. Possible extension

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

Review of New Shapes for Higher Gradients

DESIGN OF A 45 CIRCUIT DUCT BANK

Sample Testing with the Quadrupole Resonator A way to obtain RF results over a wide parameter range

Gareth Evans STV. Peter Tabolt STV. Boston, MA. Philadelphia, PA. Simulation and Mitigation of Magnetic Field Created By Traction Power Systems

Coupler Electromagnetic Design

A New 2 K Superconducting Half-Wave Cavity Cryomodule for PIP-II

Nb 3 Sn Present Status and Potential as an Alternative SRF Material. S. Posen and M. Liepe, Cornell University

4. Superconducting sector magnets for the SRC 4.1 Introduction

ADVANCES IN CW ION LINACS*

CEBAF Overview June 4, 2010

CALCULATIONS FOR RF CAVITIES WITH DISSIPATIVE MATERIAL*

INTRODUCTION. METHODS Cavity Preparation and Cryomodule Assembly

LORENTZ FORCE DETUNING ANALYSIS OF THE SPALLATION NEUTRON SOURCE (SNS) ACCELERATING CAVITIES *

KEYWORDS: ATLAS heavy ion linac, cryomodule, superconducting rf cavity.

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

Recent Results of High Gradient Superconducting Cavities at Cornell

L W C S1 S & & ILC L 1 C

SUPPRESSING ELECTRON MULTIPACTING IN TTF III COLD WINDOW BY DC BIAS

Application Information

Examination of Microphonic Effects in SRF Cavities

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann

Development of a charged-particle accumulator using an RF confinement method FA

H. Weise, Deutsches Elektronen-Synchrotron, Hamburg, Germany for the XFEL Group

THE MULTIPACTING STUDY OF NIOBIUM SPUTTERED HIGH-BETA QUARTER-WAVE RESONATORS FOR HIE-ISOLDE

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web:

HOM/LOM Coupler Study for the ILC Crab Cavity*

QUARTER WAVE COAXIAL LINE CAVITY FOR NEW DELHI LINAC BOOSTER*

3.9 GHz System (AH1) XFEL WP46

SPECIFICATIONS FOR A 4.7 TESLA/310MM BORE ACTIVELY SHIELDED MAGNET SYSTEM

STATUS OF THE ILC CRAB CAVITY DEVELOPMENT

Tests of the Spoke Cavity RF Source and Cryomodules in Uppsala

Physics Requirements Document Document Title: SCRF 1.3 GHz Cryomodule Document Number: LCLSII-4.1-PR-0146-R0 Page 1 of 7

Units. In the following formulae all lengths are expressed in centimeters. The inductance calculated will be in micro-henries = 10-6 henry.

LOW-β SC RF CAVITY INVESTIGATIONS

Recent Progress in the Superconducting RF Program at TRIUMF/ISAC

SRF EXPERIENCE WITH THE CORNELL HIGH-CURRENT ERL INJECTOR PROTOTYPE

Cryogenics for Large Accelerators

SRF Advances for ATLAS and Other β<1 Applications

SPECIFICATION FOR A 7.0 TESLA/400MM ROOM TEMPERATURE BORE MAGNET SYSTEM

PROGRESS IN IFMIF HALF WAVE RESONATORS MANUFACTURING AND TEST PREPARATION

Fiducialization of Superconducting Radio Frequency Cryomodules at Jefferson Lab

THE HIGH LUMINOSITY PERFORMANCE OF CESR WITH THE NEW GENERATION SUPERCONDUCTING CAVITY

Couplers for Project X. S. Kazakov, T. Khabiboulline

HIGHER ORDER MODES FOR BEAM DIAGNOSTICS IN THIRD HARMONIC 3.9 GHZ ACCELERATING MODULES *

NONDISTRUCTIVE TESTING INSTRUMENT OF DISHED Nb SHEETS FOR SRF CAVITIES BASED ON SQUID TECHNOLOGY

HOM COUPLER ALTERATIONS FOR THE LHC DQW CRAB CAVITY

SIMULATIONS OF TRANSVERSE HIGHER ORDER DEFLECTING MODES IN THE MAIN LINACS OF ILC

Using Higher Order Modes in the Superconducting TESLA Cavities for Diagnostics at DESY

The HOMSC2018 Workshop in Cornell A Brief Summary

Illinois. I Physics. Investigation of TESLA Damping Ring Kickers using the A0 Photoinjector Beam

CHALLENGES IN ILC SCRF TECHNOLOGY *

The ATLAS Toroid Magnet

Aurélien Ponton. First Considerations for the Design of the ESS Cryo-Modules

Advances in CW Ion Linacs

Behavior of the TTF2 RF Gun with long pulses and high repetition rates

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

TESLA Progress on R1 & R2 issues

REVIEW OF NEW SHAPES FOR HIGHER GRADIENTS

SUPERCONDUCTING PROTOTYPE CAVITIES FOR THE SPALLATION NEUTRON SOURCE (SNS) PROJECT *

INFN School on Electron Accelerators. Cryomodule Design & Cryogenics

Magnetic and Electromagnetic Microsystems. 4. Example: magnetic read/write head

Insertion Devices Lecture 4 Undulator Magnet Designs. Jim Clarke ASTeC Daresbury Laboratory

CHAPTER 6 CARBON NANOTUBE AND ITS RF APPLICATION

Properties of Inductor and Applications

Tuning systems for superconducting cavities at Saclay

Current Industrial SRF Capabilities and Future Plans

Transcription:

A Study of Magnetic Shielding Performance of a Fermilab International Linear Collider Superconducting RF Cavity Cryomodule Anthony C. Crawford Fermilab Technical Div. / SRF Development Dept. acc52@fnal.gov 02Sep14 This note presents measurements that support the conclusion that it is feasible to achieve magnetic field values at the level of 5 milligauss for a cryomodule in a realistic and representative ambient magnetic field environment. The Goal for Shielding For the case of nitrogen doped bulk niobium 1.3 GHz cavities [1], the working assumption is that an ambient magnetic field of 5 milligauss, or less, averaged over the RF surface of the cavities, is required in order to achieve a total RF surface resistance less than 10 nanoohms at 2K. For a TeSLA shaped cavity this is equivalent to Q 0 = G/10 nanoohms = 2.7 x 10 10 (G = 270 for a TeSLA cavity.) Magnetic Shielding Properties of a Fermilab International Linear Collider (ILC) Cryomodule A cylindrical shield with magnetic field oriented in the direction of the cylindrical axis (longitudinal field), has an attenuation factor that decreases proportionally to (D/L) 2, where D is the shield diameter and L its length. For long cylindrical geometries that typically occur in cryomodules made up of multicell elliptical cavities, passive shielding of the longitudinal field is much less effective than shielding of the transverse fields. For understanding the inherent difficulty of longitudinal cylindrical magnetic shielding, there is no better reference that the TeSLA Test Facility (TTF) Design Report (1995), and the reader is urged to study the magnetic shielding section within the report [2]. The ambient magnetic field model that is used in this report is the future site of the SLAC Linac Coherent Light Source II (LCLS2). Measurements made in the SLAC linac tunnel indicate that the average ambient longitudinal field near the location of the beamline is approximately 90 mgauss, with with a standard deviation of approximately 90 mgauss. What is the best that can be done with ILC style steel vacuum vessels? Will the TTF shield arrangement be good enough for LCLS2? The answer depends on how effectively the steel vacuum pipe can be demagnetized. Remnant magnetic field in excess of 3 Gauss is present in the steel pipe as received from the manufacturer. The remnant longitudinal field in an FNAL ILC cryomodule vacuum vessel pipe at the location of the SRF cavity axis is shown in Figure 1 as well as the result obtained from a demagnetization procedure. The pipe was manufactured from ASTM A516 Grade 60 steel, commonly referred to as boiler plate. Remnant magnetic field in structures of this type is the result of residual stress remaining in the steel after forming and welding procedures and possibly of handling the plate stock with industrial electromagnet lifting fixtures. It should be noted that the cryomodule steel pipe was pointed approximately East to West on the floor of the Fermilab Industrial Center Building (ICB) for the measurements shown in Figure 1. The East-West magnetic field is quite small at this location, with an average value of only 50 mg. The result of the demagnetization procedure is that the longitudinal field at the cavity axis has been reduced to approximately ±17 mgauss for this location. Figure 1. Measurement of an FNAL ILC Cryomodule Empty Steel Pipe Before and After Demagnetization 1

y (Down) Following the demagnetization procedure, the cryomodule was moved to a different location on the ICB floor in order to make measurements in a larger average ambient longitudinal magnetic field. This location will be referred to as the North-South (N-S) site in this report. An average longitudinal (N-S) field of 157 mg was obtained over the length of the steel pipe and was judged to be a suitable representation for the LCLS2 longitudinal field. The coordinate system used for the N-S site is shown in Figure 2. The ambient field at the N-S site and its components are shown in Figure 3. x (West) Figure 2. The Coordinate System Used for Magnetic Field Measurement at Site 2 Figure 3. Ambient Magnetic Field at the N-S Site 2

A set of eight helium vessels was suspended from an ILC helium return pipe and used as a means of mechanical support for a set of eight Cryoperm10 magnetic shields. Each individual shield was 1.024 meter long and adjacent shields were separated by a longitudinal gap that was 0.305 meter in length. The thickness of the Cryoperm10 was 1mm. The shields were left open ended for initial magnetic measurements. The assembly was then installed inside the steel pipe which was then moved to the N-S location. The location of shields within the steel pipe can be seen in the photograph of Figure 4. Magnetic field components measured along the axis of the Cryoperm shields are shown in Figure 5. It should be noted that measurements from DESY and Helmholtz-Zentrum Berlin indicate that Cryoperm10 and similar cryogenic shielding materials tend to have approximately the same value for permeability at 9.2K as at room temperature. This is the basis for using measured room temperature magnetic field values to predict the field that the cavities will experience at 9.2K [3]. Cryoperm10 Shield Figure 4. Cryoperm Shields Within the Steel Pipe 3

Figure 5. The Longitudinal Magnetic Field Inside the Cryoperm10 Shields at the N-S Site. (Green rectangles represent the locations of the individual shields) It is evident from Figure 5 that with an average ambient longitudinal field of 157 mgauss, and ignoring enhanced field at the ends of the cavity shields, we are rather far away from achieving the 5 mgauss specification. The addition of end caps ie, partial closures mounted on extensions and attached to the ends of the shields will significantly reduce fields at the ends, but not near the midpoints of the shields. In order to partially correct the central field, the same electrical coils that were used in the demagnetization procedure were used to cancel the longitudinal ambient field. The coil assembly consists of a series arrangement of Helmholtz type coils, separated by one half the diameter of the pipe. The coil at each end of the pipe can be excited by an independent current power supply in order to trim end effects from the steel pipe. The cancellation coils can be seen in Figure 6. Figure 6. Ambient Longitudinal Field Cancellation Coils Applied to the Outside Surface of the Steel Pipe 4

The total magnitude of the magnetic field, after applying the cancellation coils, can be seen in Figure 7. While the central field is reasonably low, the field when averaged over the active lengths of the cavities is 20 mgauss, due to the large fields at the ends of the Cryoperm shields. Figure 7. Magnetic Field Magnitude With Active Longitudinal Cancellation TTF style end caps were not available for this measurement. However, a reasonable approximation to a set of TTF end caps was improvised using FNAL ILC style end of cryomodule caps. An end cap assembly can be seen in Figure 8. One set of these was installed on the leftmost cavity shown in Figure 7. The total field magnitude both before and after installation of the end caps can be seen in Figure 9. Figure 8. Cryoperm10 End Cap Assembly 5

Figure 9. Cavity Number One Position Magnetic Field With and Without End Caps The average field over the active length of the cavity for the case without end caps is 17 mgauss and for the case with end caps is 4 mgauss. This result allows the following argument to be made: For the case of an FNAL ILC cryomodule, with a demagnetized steel pipe, active longitudinal field cancellation, and efficiently designed individual cavity shield end caps, you can achieve 5 mgauss average field at the cavities in an ambient longitudinal field of 157 mgauss. However, with this arrangement, any safety margin would have to come from enhanced flux expulsion technique applied during the cavity cooldown through 9.2K. What Can Be Done to Increase the Shielding Safety Factor? Two dimensional finite element modeling indicates that there is a significant benefit to longitudinal and transverse field attenuation that can be gained by including a high permeability room temperature liner approximately one centimeter inside the radius of the steel pipe. The values in table 1 were calculated using the parameters for room temperature Mu Metal. The calculated attenuation factor reflects the attenuation of the total field, but is dominated by the longitudinal field component. Liner Calculation Assumptions Relative Attenuation of Magnetic Field Magnitude None μ r = 1 1 0.5 mm thick non-linear B-H (Mu Metal) 2 1 mm thick μ r = constant = 24,000 2 1 mm thick non-linear B-H (Mu Metal) 4 Table 1. Calculated Values for a High Permeability Liner Inside the Steel Pipe 6

Because the 5 mgauss specification can essentially be met with a safety factor of 1 without a liner, the calculated attenuation factors for the different liners in Table 1 are equal to the final safety factor for magnetic shielding, should a liner be adopted. The additional layer of shielding could only be implemented with significant increased cost and difficulty. The cost of Mu Metal or Permalloy 80 is approximately half that of Cryoperm10 per unit weight. The increased size makes this an expensive addition to the cost of shielding. Incorporating another cylindrical layer of structure within the cryomodule is a significant engineering and assembly task. Yet, it may be necessary in order to meet the 5 mgauss specification with acceptably low risk. Summary A specification of B average 5 mgauss can be met with the following arrangement: 1. A demagnetized steel vacuum vessel 2. Segmented one layer cryogenic shields at the cavity helium vessels 3. Efficient end caps for the cryogenic shields 4. Active cancellation of the longitudinal ambient field component There is effectively no safety margin with this arrangement if the longitudinal ambient field exceeds 157 mgauss. A safety factor can be purchased by implementing a high permeability room temperature shield at the vacuum vessel radius. References [1] A. Grassellino, et al, Nitrogen and Argon Doping of Niobium for Superconducting Radio Frequency Cavities, Supercond. Sci. Technol. 26, 102001 (2013). http://dx.doi.org/10.1088/0953-2048/26/10/102001 [2] The Conceptual Design Report for the TeSLA Test Facility Linac: Version 1.0, 1995, p. 160 http://tesla.desy.de/ttf_report/cdr/pdf/cdr_chap4.pdf [3] Kugeler, O., et al, Improving the Intrinsic Quality Factor of SRF Cavities by Thermal Cycling, Proceedings of SRF2011, Chicago, USA. http://accelconf.web.cern.ch/accelconf/srf2011/papers/thpo011.pdf 7