factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

Similar documents
SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Designing Of Distributed Power-Flow Controller

Voltage Control and Power System Stability Enhancement using UPFC

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Modeling and Simulation of STATCOM

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Chapter 10: Compensation of Power Transmission Systems

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Power Quality enhancement of a distribution line with DSTATCOM

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Comparison of FACTS Devices for Power System Stability Enhancement

FACTS devices in Distributed Generation

Improving the Electric Power Quality by UPFC Systems in Electrical Networks

ELEMENTS OF FACTS CONTROLLERS

Performance and Analysis of Reactive Power Compensation by Unified Power Flow Controller

Interline Power Flow Controller: Review Paper

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

Real and Reactive Power Coordination for a Unified Power Flow Controller

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Performance Of Distributed Power Flow Controller (DPFC) Under Fault Condition

Investigation of D-Statcom Operation in Electric Distribution System

Performance Improvement of Power System Using Static Synchronous Compensator (STATCOM) Priya Naikwad, Mayuri Kalmegh, Poonam Bhonge

Available ONLINE

A Review on Mid-point Compensation of a Two-machine System Using STATCOM

ENHANCING POWER SYSTEM STABILITY USING NEURO-FUZZY BASED UPFC

Optimal Placement of Shunt Connected Facts Device in a Series Compensated Long Transmission Line

STUDY AND SIMULATION OF THE UNIFIED POWER FLOW CONTROLLER (UPFC) IN POWER SYSTEM

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Analysis of FACTS Devices in Transmission System

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Modified Approach for Harmonic Reduction in Transmission System Using 48-pulse UPFC Employing Series Zig-Zag Primary and Y-Y Secondary Transformer

Performance of DVR & Distribution STATCOM in Power Systems

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Power flow improvement using Static Synchronous Series Compensator (SSSC)

Power Quality and the Need for Compensation

International Journal of Advance Engineering and Research Development

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Power System Oscillations Damping and Transient Stability Enhancement with Application of SSSC FACTS Devices

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

The Influence of Thyristor Controlled Phase Shifting Transformer on Balance Fault Analysis

Enhancement of Power Quality in 14 Bus System using UPFC

Improvement in Power Quality of Distribution System Using STATCOM

Comparison of Simulation and Experimental Results of UPFC used for Power Quality Improvement

SIMULATION RESULTS OF EIGHT BUS SYSTEM USING PUSH-PULL INVERTER BASED STATCOM

I. INTRODUCTION. Keywords:- FACTS, TCSC, TCPAR,UPFC,ORPD

Design and Simulation of Passive Filter

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online):

Comparison of Simulation Results of D-Facts & UPFC Used for Power Quality Improvement

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

POWER FLOW CONTROL WITH UPFC IN POWER TRANSMISSION SYSTEM

Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multimachine System

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

Transfer Capability Enhancement of Transmission Line using Static Synchronous Compensator (STATCOM)

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Application of IPFC Scheme in Power System Transients and Analysed using Fuzzy Technology

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

Damping Power system Oscillation using Static Synchronous Series Compensator (SSSC)

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

Keywords: Stability, Power transfer, Flexible a.c. transmission system (FACTS), Unified power flow controller (UPFC). IJSER

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Improvement of Transient stability in Power Systems with Neuro- Fuzzy UPFC

Transient Stability Improvement of Multi Machine Power Systems using Matrix Converter Based UPFC with ANN

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

Implementing Re-Active Power Compensation Technique in Long Transmission System (750 Km) By Using Shunt Facts Control Device with Mat Lab Simlink Tool

Experimental Verification and Matlab Simulation of UPFC for Power Quality Improvement

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 8 Issue 1 APRIL 2014.

Power Quality Compensation by using UPFC

Analysis and Enhancement of Voltage Stability using Shunt Controlled FACTs Controller

Designing and Control of Converters used in DPFC for Mitigation of Voltage Sag and Swell In Transmission Line

A New Control Scheme for Power Quality Improvement with STATCOM

Performance Evaluation of Mho and Quadrilateral Characteristic Relays on UPFC Incorporated Transmission Line

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Application of SSSC-Damping Controller for Power System Stability Enhancement

Brief Study on TSCS, SSSC, SVC Facts Device

Improvement Voltage Sag And Swell Under Various Abnormal Condition Using Series Compensation

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

Multi-Pulse Voltage Source Converter Statcom For Voltage Flicker Mitigation

A Review on Improvement of Power Quality using D-STATCOM

Improvement of System Reliability & Power Transfer Capability using Distributed Power- Flow Controller (DPFC)

POWЕR QUALITY IMPROVEMENT IN POWЕR SYSTЕM BY USING SVPWM BASED STATIC SYNCHRONOUS SЕRIЕS COMPЕNSATOR

[Kumar*, 4.(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Control Of Shunt Active Filter Based On Instantaneous Power Theory

FACTS Devices and their Controllers: An Overview

Transient Stability Enhancement with Application of FACTS Devices

A.V.Sudhakara Reddy 1, M. Ramasekhara Reddy 2, Dr. M. Vijaya Kumar 3

Transcription:

2011 International Conference on Signal, Image Processing and Applications With workshop of ICEEA 2011 IPCSIT vol.21 (2011) (2011) IACSIT Press, Singapore Location of FACTS devices for Real and Reactive Power Flow Control A. Kumaran 1, A. Allirani 2 1 Research Scholar, Anna University of Technology, Coimbatore,Tamilnadu-641 047. 1E-mail:principalmekumaran@gmail.com. 2 The Principal, SRS college of Engineering and Technology, Salem, Tamilnadu -636 122. 2E-mail: allirani2004@gmail.com Abstract. In present years, the electrical power system is very complex and it requires very careful design of new devices are needed to improve electric power utilization and maintaining power system stability, power loss minimization and security. This paper presents an approach to find the optimal location of FACTS devices such as Unified Power Flow Control (UPFC), Static Synchronous Compensator (STATCOM), Static Synchronous Series Compensator (SSSC), Thyristor-Controlled Series Compensators (TCSC) and Static Var Compensator (SVC) in electrical power transmission system which improve the Active and Reactive power flow of transmission lines, voltage regulation and minimize power loss. The FACTS devices are the most versatile and complex power electronic equipment that has required for the control and optimization of power flow in electrical power transmission system. This research deals with Active and reactive power flow control through a transmission line by placing FACTS devices at the sending end of the electrical power transmission line. Simulations were carried out using Matlab/Simulink software to validate the performance of the FACTS devices. Keywords: Unified Power Flow Control,Static Synchronous Compensator, Thyristor-Controlled Series Compensators, Flexible AC Transmission Systems(FACTS). 1. Introduction (Use Header 1 Style) Now a day s electrical power systems are more complex and it s require careful design of new devices are needed to improve electric power utilization while still maintaining reliability, stability, minimizing power loss and security. Thus, this needs a review of traditional methods and the creation of new concepts that emphasize a more efficient use of already existing power system resources without reduction in system stability and security. The proposed concept is known as Flexible AC Transmission Systems (FACTS) [1,5,6,7]. The main objectives of FACTS devices are to increase the transmission capacity, minimize the power loss, maintaining stability, reduce the power system cost and control power flow over designated transmission routes. A new generation of FACTS controllers is on voltage source converters and includes devices such as Static Var Compensators (SVC), Static Synchronous Compensators (STATCOM), Thyristor Controlled Series Compensators (TCSC), the Static Synchronous Series Compensators (SSSC), Thyristor Controlled Phase Angle Regulator (TCPCT) and the Unified Power Flow Controllers (UPFC). The UPFC is the most versatile and complex of the FACTS devices, combining the features of the STATCOM and the SSSC. The UPFC can provide simultaneous control of all basic electrical power system parameters, viz., transmission voltage, impedance, phase angle, Phase current, Real power and reactive power. FACTS devices are connected to a transmission line in various ways, such as in series, shunt, or a combination of series and shunt. Shunt compensation enhances the real power handling capacity of a line at a much lower cost than building a second transmission line of the same capacity. There are more number of 242

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is voltage stability. Voltage stability has been defined as the ability of a system to maintain voltage so that when load admittance is increased, load power will increase and both power and voltage can be controlled. The main cause of voltage instability is insufficient reactive power supply. Properly planned reactive reserve will provide adequate reactive power support at critical buses [6]. 2. Power Flow Control of UPFC The basic components of the UPFC are two voltage source inverters (VSIs) sharing a common dc storage capacitor, and connected to the power system through coupling transformers. One VSI is connected to in shunt to the transmission system via a shunt transformer, while the second VSI is connected in series with line through a series transformer. A basic UPFC functional scheme[10] is shown in fig.l. Fig. 1 Basic functional scheme of UPFC The series inverter is controlled to inject a symmetrical three phase voltage system (Vse), of controllable magnitude and phase angle in series with the line to control active and reactive power flows on the transmission line. So, this inverter will exchange active and reactive power with the line. The reactive power is electronically provided by the series inverter, and the active power is transmitted to the dc terminals. The shunt inverter is operated in such a way as to demand this dc terminal power (positive or negative) from the line keeping the voltage across the storage capacitor Vdc constant. So, the net real power absorbed from the line by the UPFC is equal only to the losses of the inverters and their transformers. The remaining capacity of the shunt inverter can be used to exchange reactive power with the transmission line so to provide a voltage regulation and security at the connection point. The two VSIs are can working independently of each other by separating the dc side. So in that case, the shunt inverter is operating as a STATCOM that generates or absorbs reactive power to regulate the voltage magnitude at the connection point. Instead, the series inverter is operating as SSSC that generates or absorbs reactive power to regulate the current flow, and hence the power flows on the transmission line. 3. Mathematical model of UPFC The basic structure and operation of the UPFC can be represented through the model[10] shown in fig.2. The transmission line parameters are as shown in Table I Fig.2 Mathematical model of UPFC In this model, we have considered the UPFC is placed at the centre of a 100km transmission line. The equations for sending end active and reactive power can be obtained from the real and imaginary powers of power equation as follows: Ps=R(Vs δi)=0.256+0.482sin(δb- δ)-0.256cos δ+2.72sin δ+0.08cos(δb- δ) 243

Qs=Im[z δi] =2.65-2.65cos δ+0.48cos (δ- δb)+0.08sin(δb- δ)-0.256sin δ The variation limits of δb and δ are according tothe following relation: 0 δb 2Π 0 δ 0.71 radians The maximum limit of δ is chosen according to the stability margin [9]. The variation of sending end active and reactive powers by varying δb and δ is obtained through MATLAB. 4. Control Structure of UPFC The superior operating characteristics of the UPFC are due to its unique ability to inject an ac compensating voltage vector with arbitrary magnitude and angle in series with the line upon command, subject only to equipment rating limits. With suitable electronic controls, the UPFC can cause the seriesinjected voltage vector to vary rapidly and continuously in magnitude and/or angle as desired. Thus, it is not only able to establish an operating point within a wide range of possible P, Q conditions on the line, but also has the inherent capability to transition rapidly from one such achievable operating point to any other. The control of the UPFC is based upon the vector-control approach(i.e., for STATCOMs). The term vector, instead of phasor, is used in this section to represent a set of three instantaneous phase variables, voltages, or currents that sum to zero. The symbols V and I are used for voltage and current vectors. For the purpose of power control it is useful to view these vectors in an orthogonal coordinate system with p and q axes such that the p axis is always coincident with the instantaneous voltage vector v and the q axis is in quadrature with it. In this coordinate system the p-axis current component, i p, accounts for the instantaneous real power and the q-axis current component, i q, for the reactive power. Fig.3. Overall UPFC control structure Under balanced steady-state conditions, the p-axis and q-axis components of the voltage and current vector are constant quantities. This characteristic of the described vector representation makes it highly suitable for the control of the UPFC by facilitating the decoupled control of the real and reactive current components. "The UPFC control system may, in the previously established manner, be divided functionally into internal (or converter) control and functional operation control. The internal controls operate the two converters so as to produce the commanded series injected voltage and, simultaneously, draw the desired shunt reactive current. The external or functional operation control defines the functional operating mode of the UPFC and is responsible for generating the internal references, VpqRef and IqRef, for the series and shunt compensation to meet the prevailing demands of the transmission system. The functional operating modes and compensation demands, represented by external (or system) reference inputs, can be set manually (via a computer keyboard) by the operator or dictated by an automatic system optimization control to meet specific operating and contingency requirements. An overall control structure, showing the internal, the functional operation, and system optimization controls with the internal and external references is presented in Figure 3[1,2,3,4].The capability of unrestricted series voltage injection together with independently controllable reactive power exchange offered by the circuit structure of two back-to-back converters, facilitate several operating and control modes for the UPFC. 244

5. Simulation Setup in MATLAB Fig. 4 shows the simulation model including a power system with a transmission line[9,10]. The UPFC installed near the sending end effectively controls the power flow from sending end to the receiving end. Fig. 4. Power system study model Here, Vs and Vr are assumed to be sending and receiving-end voltages. This model assumes that sending end corresponds to a power plant while the receiving end to an electric power network, i.e., SMIB system. The receiving end voltage may not cause any phase angle change, because Vr is an infinite bus voltage. The phase angle of Vs is adjusted according to the power demand for the power plant. A phase difference of 10 0 between sending-end and receiving end voltages is simulated. The main circuit of the series device (SSSC) consists of a three phase PWM inverter, the ac terminals of which are connected in series to a transmission line through three single phase transformers. The shunt device (STATCOM) consists of a three phase PWM inverter, the ac terminals of which are connected in parallel with the transmission line via a three phase star-delta transformer. In this simulation, the shunt inverter operates in automatic voltage control mode. Similarly, AC voltage from the sending end bus feeding the shunt coupling transformer is measured in p.u, (Vpum) and compared with the AC voltage set point (here 1.0 p.u), whose error is fed to PI controller to generate modulation index, mi. 6. Power Flow Control of STATCOM and SSSC This chapter presents the operating principles and applications of several highly versatile controllers are the STATCOM, SSSC, and UPFC without any prejudice to other FACTS controllers [1,8]. These three FACTS controllers are second generation types that are based on non Thyristor devices such as Gate Turn- Offs (GTOs) and Insulated-Gate Bipolar Transistors (IGBTs). STATCOM (or SSC) is a shunt-connected reactive-power compensation device that is capable of generating and/or absorbing reactive power and in which the output can be varied to control the specific parameters of an electronic power system. A STATCOM can improve power-system performance in dynamic voltage control in transmission and distribution systems, Power-oscillation damping in powertransmission systems, Transient stability, Voltage flicker control and Control of not only reactive power but also (if needed) active power in the connected line requiring a dc energy source. A STATCOM is a controlled reactive-power source. It provides he desired reactive-power generation and absorption entirely by means of electronic processing of the voltage and current waveforms in a voltagesource converter (VSC) and VSC is connected to a utility bus through magnetic coupling. STATCOM is seen as an adjustable voltage source behind a reactance meaning that capacitor banks and shunt reactors are not needed for reactive-power generation and absorption, thereby giving a STATCOM a compact design, or small footprint, as well as low noise and low magnetic impact. The exchange, of reactive power between the converter and the ac system can be controlled by varying the amplitude of the 3-phase output voltage, E s of the converter. That is, if the amplitude of the output voltage is increased above that of the utility bus voltage, then a current flows through the reactance from the converter to the ac system and the converter generates capacitive-reactive power for the ac system. If the amplitude of the output voltage is decreased below the utility bus voltage, then the current flows from the ac system to the converter and the converter absorbs inductive-reactive power from t ac system. In other words, 245

the converter can supply real power to the ac system from its dc energy storage if the converter-outputvoltage is made to lead the ac-system voltage. STATCOM provides the desired reactive power exchanging the instantaneous reactive power by among the phases of the ac system. Adjusting the phase shift between the converter-output voltage and the ac system voltage can similarly control real-power exchange between the converter and the ac system. On the other hand, it can absorb real power from the ac system for the dc system if its voltage lags behind the acsystem voltage. A STATCOM provides the desired reactive power exchanging the instantaneous reactive power by among the phases of the ac system. 7. Simulation Results A transmission line of a simple power system with parameters as given in Table 1[10] is considered. UPFC is placed in series with the transmission line at the sending end. Voltage, active power, reactive power and current variations in the transmission line with UPFC and without UPFC are studied. The power system studied is SMIB system, when the transmission line is without UPFC, the sending-end and receiving-end voltages are as shown in fig. 5(a)&(b). When UPFC is placed across the same transmission line, the voltage regulation is improved as per fig 6. (a)with UPFC (b) Without UPFC Fig. 5. Sending end and Receiving end voltages Fig.6. Receiving end voltage With UPFC In this simulation, the theta order input to the series inverter control circuit is 50.By varying the theta order input to the controller the phase and magnitude of the series injected voltage can be varied. When the transmission line is without UPFC, the real and reactive power flow cannot be controlled. Fig.7 (a) shows the active power through the line with UPFC. Fig.7 (b) shows the active power flow through line without UPFC. Transmission capability of the existing transmission line is highly improved with the presence of UPFC. But the difference between the sending end real power and receiving end real power is high in the transmission line with UPFC. This is due to the increase in transmission losses, which include losses in the both converters and coupling transformers. 246

(a)with UPFC (b) Without UPFC Fig. 7. Receiving end active power (a)with UPFC (b) Without UPFC Fig. 8. Receiving end reactive power The reactive power flow through the transmission line with and without UPFC is shown fig. 8.The raise in the transmission capability is noticed from the simulation results. The power transfer capability of long transmission lines is usually limited by their thermal capability. Utilizing the existing transmission line at its maximum thermal capability is possible with UPFC. Fig.9.Sending end voltage with SSSC Fig.10.Receiving end voltage with SSSC Fig. 11. Receiving end reactive and active power with STATCOM 247

The current through phase A of the transmission line with UPFC, it raise in the transmission capability of the transmission line. The current transfer capability of long transmission lines is usually limited by their thermal capability. Utilizing the existing transmission line at its maximum thermal capability is possible with UPFC. The Sending end and Receiving end voltages with SSSC are shown in fig.9&10.the receiving end reactive and active power of the transmission line with STATCOM is shown in fig 11. The raise in the transmission capability is noticed from the simulation results. 8. Conclusion Line to line voltage Frequency Transmission rating TABLE 1. SYSTEM PARAMETER 1000 kv 50 Hz 100 MVA Capacitance of DC link Capacitor 1500µF DC link voltage Length of the transmission line Resistance of the line Inductive reactance of the line Capacitive reactance of the line 50kV 400km 32 µω/m 350.3 µω/m 274.5 MΩ/m In this research, the MATLAB environment is used to simulate the model of FACTS controllers connected to a three phase-three wire transmission system. This research paper presents control and performance of FACTS devices intended for installation on a transmission line. This FACTS control system is simulated with shunt inverter in AC and DC voltage control mode and series inverter in open loop phase angle control mode. Simulation results show the effectiveness of FACTS controllers in controlling real and reactive power through the transmission line. Due to the AC voltage controller, AC voltage regulation has improved. The DC voltage controller maintains the DC link voltage to the DC voltage set point about 50 kv. This technique improved in the real and reactive power flow through the transmission line with FACTS devices when compared to the system without FACTS devices. 9. Reference [1] N. G. Hingorani and L. Gyugyi, Understanding FACTS, Concepts, and Technology of Flexible AC Transmission Systems. Piscataway, NJ: IEEE Press, 2000. [2] Eskandar Gholipur and Shahrokh Saadate, "Improving of Transient Stability is Power Systems Using UPFC" IEEE Trans. Power Del., vol. 20, no. 2, pp. 1677-1682, Apr. 2005. [3] Q. Yu, S. D. Round, L. E. Norum, T. M. Undeland, "Dynamic Control of a Unified Power Flow Controller," IEEE Trans. Power Del., vol. 9, no. 2, pp.508-514, Apr. 1996. [4] H. Fujita, Y. Watanabe and H. Akagi, "Control and Analysis of a Unified Power Flow Controller," IEEE Trans. Power Elect, vol. 14, no. 6, pp.1021-1027, Nov. 1999. [5] H. Fujita, Y. Watanabe and H. Akagi, "Dynamic Control and Performance of a Unified Power Flow Controller for Stabilizing an AC Transmission System," IEEE Trans. Power Elect, vol. 21, no. 4, pp.1013-1020, July,.2006. [6] N.P.Pathy, M.A.Abdel Moamen, Power flow control and solutions with multiple and multi type FACTS devices, Electric power system research(october)(2004) [7] A.A. Edris, R. Aapa, M.H. Baker, L. Bohman, K. Clark, "Proposed terms and definitions for flexible ac transmission system (FACTS)", IEEE Tran. on power delivery Vol. 12, No. 4, Oct. 1997. [8] V. K. Chandrakar, A.G. Kothari, "Optimal Location for Line Compensation by Shunt Connected FACTS Controller" The Fifth International Conference on Power Electronics and Drive Systems, PEDS 2003, Vol. 1, Page(s): 151 156, 17-20 Nov. 2003. [9] H. I. Shaheen, G. I. Rashed, and S. J. Cheng, Optimal Location and Parameters Setting of Unified Power Flow Controller Based on Evolutionary Optimization Techniques, IEEE PES 2007 General Meeting, 2007, pp. 1-8. [10] S. Tara Kalyani and G. Tulasiram Das Simulation of real and Reactive Power Flow Control With UPFC 248