a Nexans company Catalogue 2014

Similar documents
a Nexans company Catalogue 2012

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

a Nexans company Catalogue 2012

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2009

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

Compact catalogue 2014/2015

Premoulded cable joint SMPGB

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Medium Voltage Power Cables

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Ritz Instrument Transformers GmbH. Welcome

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

Energy Division. Bowthorpe LV/MV Surge Arresters

A. Product Description: Stranded conductor insulated wire.

Data sheet. W-Series WDU 2.5

END CAP & HEAT SHRINK SLEEVE

ELECTRICAL R&D LABORATORY SPECIFICATION FOR TESTS OF COMPRESSION AND MECHANICAL CONNECTORS AND TERMINAL LUGS FOR POWER CABLES WITH COPPER

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

147,LoharChawl,9,TavawalaBuilding,1stFloor,MUMBAI

JCN cables. The. splice is an

Underground System Design TADP 547

CABLE JOINTING KITS &

Cable connection. 58 RM6 catalogue schneider-electric.com

SRS SEALED ROTARY SENSORS

Product Catalogue CABLE CONNECTION TECHNIQUE. Ring Connectors

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Data sheet... W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

INSTALLATION INSTRUCTION HEATSHRINK TRIFURCATING TRANSITION JOINT TO SUIT 3 CORE

Powersafe Termination Guide

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

Low Voltage Splices, 1000 V or less

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Company Profile.

3M Electrical Markets Division 3M Cold Shrink Silicone Rubber Splices QS-III. Easy Installation. High reliability.

QSLVM2500 QSLV-M Cold Shrink Insulator

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Data sheet. W-Series WDU 4 BL

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

Data sheet. W-Series WDU 10

Armoured Power and Control Cables Fire Resistant

P3-19 Series Connectors For Entertainment Lighting

Thru Wall Floor Seals For New Installation

Low Loss Pre-Connectorized Cable Sets, LL58 Series, DC-3.5GHz

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Low Voltage Splices 0-600V (1000V rated) Cold Shrink Splices (0-1000V)

POTENTIAL TRANSFORMER

General Information...SA1-SA4

ULC STANDARDS TECHNICAL WORK PROGRAM (WTO) Last modified on:

Substation HV Cables. Document Number: 1-11-FR-07

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

Capacitor Switching Contactors

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

50-SDMS-01 SPECIFICATIONS FOR

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Distribution transformers Part 2 Ground mounted transformers not closecoupled

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

Tri-Rated Flexible PVC Equipment Wire

MV water-proof and water tree retardant power cable

Datenblatt. W-Series WDU 2.5

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

Electric cables. Cranes

Transformers connected via a cable Overvoltage protection

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

TECHNICAL SPECIFICATION

AEE. Canada. Australia

insulate seal protect EquipmEnt insulation and ConnECtion products

SECTION MEDIUM-VOLTAGE CABLES

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

(

TECHNICAL SPECIFICATION

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Measuring current transformers of the W, W series

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Armoured Instrumentation Cables to BS6883

Interconnect and Termination Devices

METRATESTER 5+ Tester for DIN VDE /6.15

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Order Information. Nominal CCT

374/375/376 Clamp Meter. Users Manual

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Evaluation of Distribution Line Spacers through the Leakage Current Monitoring

Datenblatt. W-Series WDU 10

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Transcription:

a Nexans company Catalogue 014

Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from 1 to 4 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 199, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International standards All our products meet the International standards like CENELEC HD 69.1, CENELEC EN 50180, IEC 601, IEC 6050-4 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.144-test conform with the European standards for laboratories ISO 105 for electrical testing of low and medium voltage cable accessories according to the international standards EN 509, IEC 6050-4, IEC 6144 and HD 69. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve. 1

TERMINATIONS Table of contents ITK - indoor termination OTK - outdoor termination AIN - indoor termination AFN - outdoor termination T-ITK - -core indoor termination T-OTK - -core outdoor termination 15TS-NSS - universal bushing boot 04/014

AIN SLIP-ON INDOOR TERMINATION Application A kit of terminations for use indoors in controlled environmental conditions and subject to light condensation. Provides a simple and quick method of stress relieving on screened polymeric cables. Up to 4 kv 6/10 (1) kv 6.5/11 (1) kv 8./15 (1.5) kv 1/0 (4) kv 1./ (4) kv 18/0 (6) kv 0.8/6 (4) kv Design Indoor termination comprising: 1. Cable lug (not included in the standard kit).. High flexibility silicone rubber housing, allowing larger tolerances on cable insulation diameters, with integrated conductive rubber insert, providing stress relief.. Earthing lug (not included in the standard kit). 1 Specifications and standards Meets the requirements of CENELEC HD 69.1 and IEC 6050-4. Termination type Voltage Um (kv) min Conductor sizes (mm ) max AIN 10 AIN 0 AIN 0 AIN 6 1 4 6 4 5 5 50 06/014 8

Kit contents A kit always comprises termination housings, installation instructions, special lubricant, wiper, adhesive tape, field control mastic,... Cable lugs and earthing lugs are not included in the standard kit, but can be ordered separately. Ordering instructions Select the part number corresponding to both the system voltage and the cable dimensions in mm. Voltage Um (kv) 1 Conductor sizes (mm ) Diameter over core insulation min max min max 5 95 1. 1.0 10 40 19.0 8.5 00 500.0.0 800 4.0 9.0 50.0 58.0 Number of sheds L 5 Dia. D 4 60 68 Ordering part number x AIN 10-1 x AIN 10- x AIN 10- x AIN 0-4 x AIN 6-5 x AIN 6-6 4 5 95 00 0 40 500 800 18.0.5 1.0 4.0 9.0.5.0 41.0 50.0 58.0 5 5 5 5 4 56 68 68 x AIN 0-1 x AIN 0- x AIN 0- x AIN 0-4 x AIN 6-5 x AIN 6-6 6 50 95 40 0 40.5.0.0 9.0 9.0 8.0 4.0 50.0 58.0 6 6 6 00 00 00 4 4 81 x AIN 0-1 x AIN 0- x AIN 0- x AIN 6-5 x AIN 6-6 4 00 1.5 9.0 41.0 50.0 58.0 x AIN 6-4 x AIN 6-5 x AIN 6-6 Example: A set of indoor terminations for a 4 kv - 40 mm stranded aluminium cable with copper wire screen without cable lugs. The diameter over core insulation is 0.4 mm. Order a x AIN 0- termination kit. For use with copper wire screened cables. No earthing device is necessary. For use with copper tape screened cables. Order: -/MT. For use with three-core cables. Please contact our representative. For use with other cable types. Please contact our representative. Can be supplied with all common types of cable lugs. No heating or flame is required. 9

AFN SLIP-ON OUTDOOR TERMINATION Application A kit of terminations for use outdoors and exposed to prolonged sunshine and other weather conditions. To connect polymeric insulated cable to equipment and for the outdoor terminating on to overhead lines or bus bars. Up to 4 kv 6/10 (1) kv 6.5/11 (1) kv 8./15 (1.5) kv 1/0 (4) kv 1./ (4) kv 18/0 (6) kv 0.8/6 (4) kv Design Outdoor termination comprising: 1. Cable lug (not included in the standard kit).. Water sealing silicone sleeve.. Silicone housing with sheds and integrated conductive silicone rubber insert providing stress relief for the cable. 4. Water sealing mastic. 5. Earthing clamp. 6. Earthing lug (not included in the standard kit). 1 Specifications and standards Meets the requirements of CENELEC HD 69.1 and IEC 6050-4. 5 4 6 Termination type Voltage Um (kv) min Conductor sizes (mm ) max AFN 10 AFN 0 AFN 0 AFN 6 1 4 6 4 5 5 50 06/014 10

Kit contents A kit always comprises termination housings, water sealing sleeve, the installation instructions, special lubricant, wiper, earthing clamp, water sealing mastic, adhesive tape, field control mastic,... Cable lugs and earthing lugs are not included in the standard kit, but can be ordered separately. Ordering instructions Select the part number corresponding to both the system voltage and the cable dimensions in mm. Voltage Um (kv) 1 4 6 4 4 Conductor sizes (mm ) Diameter over core insulation min max min max 5 95 10 40 00 500 800 5 95 00 50 95 40 0 0 40 500 800 0 40 10 00 1. 19.0.0 4.0 9.0 1.0 8.5.0 50.0 58.0 18.0.5.5.0 1.0 41.0 4.0 9.0 50.0 58.0.5 9.0.0 8.0.0 4.0 9.0 50.0 58.0 8.0.0 1.5 41.0 9.0 50.0 58.0 L Number of sheds (max) 10 10 10 4 40 4 40 4 40 4 40 4 40 6 00 6 00 6 00 Creepage Dia. D Ordering distance part number 90 69 x AFN 10-1 96 65 x AFN 10-105 60 x AFN 10-118 46 x AFN 0-4 1 55 x AFN 6-5 1 55 x AFN 6-6 100 480 x AFN 0-1 11 499 x AFN 0-118 46 x AFN 0-118 46 x AFN 0-4 1 55 x AFN 6-5 1 55 x AFN 6-6 115 695 x AFN 0-1 115 694 x AFN 0-1 18 x AFN 0-1 55 x AFN 6-5 1 55 x AFN 6-6 1 55 x AFN 6-1 55 x AFN 6-4 1 55 x AFN 6-5 1 55 x AFN 6-6 For use in heavy polluted areas (terminations with an increased creepage length) 0 10 00 8.0 1.5 9.0.0 41.0 50.0 58.0 11 11 11 11 55 55 55 55 1 1 1 1 109 109 109 109 x AFNP 6- x AFNP 6-4 x AFNP 6-5 x AFNP 6-6 Example: A set of outdoor terminations for a 4 kv - 40 mm stranded aluminium cable with copper wire screen without cable lugs. The diameter over core insulation is 0.4 mm. Order a x AFN 0- termination kit. For use with copper wire screened cables. No earthing device is necessary. For use with copper tape screened cables. Order: -/MT. For use with three-core cables. Please contact our representative. For use with other cable types. Please contact our representative. Can be supplied with all common types of cable lugs. No heating or flame is required. 11

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: a Nexans company Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan 1, B-90 Erembodegem Tel.: + (0)5 85 0 11 sales.euromold@nexans.com www.euromold.be 06/014 Catalogue also available on CD-ROM, Website and Mobile Apps