TA-Slider 160 KNX Protocol Implementation

Similar documents
TA-Slider 160 KNX R24 Protocol Implementation

TA-Slider 160. Actuators Digitally confi gurable proportional push actuator 160/200 N

Fan Coil Actuator FCA 2

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

Application Programs Descriptions

Technical manual GS 4x.00 knx application description air quality sensor

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

KNX manual 1-channel flush-mounted switch actuator SU 1

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

KNX Room temperature controller

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

SeeTool - Solutions for KNX

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

1. Use of the application program

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MDT Switch Actuator/FanCoil

GEMÜ 1242 Electrical position indicator

Brief description. Type overview

KNX presence detectors for ceiling flush mount EK-DD2-TP, EK-DE2-TP

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

TAC5 Regulation + SAT KNX Module

application software

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

EIB/KNX Switch Actuators. User manual

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Application manual KNX room temperature controller EK-EP2-TP

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

KNX ENO 620/622 (32-channel AP)

application software

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

instabus EIB product documentation

K-BUS Switch Actuator

Application manual KNX room temperature controller EK-EQ2-TP

Air Quality Sensor KNX AQS

Technical Manual MDT Air quality/co2 Sensor

Instruction manual. art Installation manual

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

Technical Manual MDT LED-Indicator

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

Tebis application software

STC-KNX (32-channel AP)

KNX ENO 634 (32-channel AP)

Application Manual KNX fan-coil actuators/controllers EK-HA1-TP EK-HB1-TP EK-HC1-TP

Technical Manual MDT Room Temperature Controller

application software

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Room thermostat solo, FM Type: 6124-xx

Digital amplifier for proportional valves PEM XD

THREE-PHASE ENERGY METER DIRECT CONNECTION PM30D01KNX. User manual

16-Channel Yearly Time Switch TR 648 S DCF

Thorsten Reibel, Training & Qualification Global Application and Solution Team

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

Operation with the Tebis TX100 configurator

Installer manual inputs/outputs interface for led KNX

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

CU-DIN DIM 6-CH 0 10V KNX

SRC-110 Series Zone Controllers with Modbus RTU

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

KNX PY. Global Irradiance Sensor. Installation and Adjustment

KNX Powerline PL 110. KNX Association

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Product documentation

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

Weather Station for KNX

KNX TH65-AP. Thermo-Hygrometer. Installation and Adjustment. Item number 70184

KNX ON/OFF controller 4 contacts 16A

Communicative heating controller

KNX 4-channel RGBW Dimmer LED module EK-GC1-TP - PWM power outputs EK-GF1-TP V control outputs

Pololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation

VAV-Compact. Contents. Modbus General Notes 2 Modbus Register Overview 3 Modbus Register Description 4

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Meteodata 140 S weather station

Unidirectional Gateway EnOcean - KNX/BUS

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Electromotoric actuators for stroke valves

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

IO-Link inductive sensors

Type 3374 Electric Actuator

Electronic pressure-independent characterised control valve with energy monitoring

Mx-D15 Intelligent Valve Actuator

Please enter the identity code of your device here!

Transcription:

10.2017 TA-Slider 160 KNX Protocol Implementation 1

Identification in KNX ETS software Product family: HVAC Product type: Valve Manufacturer: IMI Hydronic Engineering Name: TA-Slider 160 KNX Order number: 322224-0100X te: TA-Slider 160 KNX is ETS5 ready. The minimum ETS version is ETS5.0 Commissioning The proportional electro-motor, TA-Slider 160 KNX, actuator is connected directly to the KNX bus; a separate bus coupler is not required. The bus connection is carried out via the connecting cable which is fixed to the device with the help of a bus connecting terminal (not provided). An external auxiliary voltage is not necessary. It should be noted that a TA-Slider 160 KNX draws in stand-by less than 10 ma and as much as 25 ma when running in maximum load conditions. The programming of the physical address can be carried out without contact by placing a magnet as shown in below picture. KNX Wiring diagrams TA-Slider 160 KNX 2x2x0.6 mm² M - + B M - + Black Red Yellow White KNX Bus Terminal Description M Neutral B Connection for potential free contact (e.g. open window detection), max. 100 Ω, max. 10 m cable or shielded te: M terminal is internally connected to KNX - Bus wire. 2

KNX product catalogue The KNX product catalogue file can be downloaded from our website under the Documentation section of TA-Slider 160. Refer to below table to find out which product catalogue version for which actuator firmware version. Firmware version Required KNX product catalogue Production date 0.1.4 TA-Slider_160_KNX_v1_1.knxprod 0.2.0 TA-Slider_160_KNX_v1_2.knxprod From 2017-09-15 Unless indicated otherwise, all objects and parameters described in this document are present from the first version of the TA-Slider 160 KNX actuator (firmware 0.1.4, KNX product catalogue 1.1). KNX protocol implementation Available communication objects Obj Object name Object function Type Flags 1a Control value Drive to position 1 Bit CW 2a Actual value Indicate actual position 2 Bytes CRT 1b Control value Drive to position 1 Byte CW 2b Actual value Indicate actual position 1 Byte CRT 1c Control value Drive to position 2 Bytes CW 2c Actual value Indicate actual position 2 Bytes CRT 3 Detected stroke Valve stroke detected by calibration 2 Bytes CRT 4* Change-over Change-over flag 1 Bit CW 5* Drive to forced position Go to pre-defined forced position 1 Bit CW 6* Binary input Binary input value 1 Bit CRT 7 Error code Error code 2 Bytes CRT For communication objects 1 and 2 (Control value and Actual value), version a, b or c are mutually exclusive. Communication objects marked with a * are available depending on configuration. Error code is a bit field formatted as follows 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 r r r r r r r r r r r SOOR CT SDF Clogging PF r: Reserved SOOR: Signal out of range alarm CT: Cyclic timeout alarm SDF: Stroke detection failure Clogging: Clogging alarm PF: Power failure 3

Parameters Main Control type a) Two points b) Proportional - Rough positioning c) Proportional - Fine positioning (1 bit telegram) (8 bit telegram) (10000 values) Default value: Proportional - Rough positioning (8 bit telegram) Set the type of the control object. Target position for control value 0 Available when Control type is a) Default value: 0 Setpoint when a 0 is sent (control value is binary). Target position for control value 1 Available when Control type is a) Default value: 10000 Setpoint when a 1 is sent (control value is binary). Characteristic Available when Control type is b) or c) Linear Equal Percentage Modified (EQM) Inverted EQM Default value: Linear Characteristic curve of the valve. Hysteresis Available when Control type is b) or c) Accurate 1% 2% 3% 5% 7% 10% 15% Default value: 2 % Move the actuator only when the signal goes beyond this margin. Control direction Direct (0% = fully extended actuator; for push-to-close valves) Reversed (0% = fully retracted actuator; for push-to-open valves) Default value: Direct (0% = fully extended actuator; for push-to-close valves) Valve direction of the input signal. Cyclic timeout 1 min 2 min 5 min 10 min 15 min 20 min 30 min 45 min 60 min 4 Default value: Raise an error if the actuator didn t receive a control signal for the time being. This indicates the frequency of the input signal.

Maximum valve stroke Range: Min: 250, Max: 8500 Default value: 6500 Unit: µm Limit the detection range for the calibration to this upper value. Activate LED? (Only from firmware 0.2.0, KNX product catalogue 1.2) Options : Default value : Deactivate LED for a discreet device. Enable stroke limitation? Disabled Default value: Disabled Enable the stroke limitation. Enabled Limited stroke Available when stroke limitation is enabled Range: Min: 250, Max: 8500 Default value: 6500 Unit: µm Indicate the Limited stroke value. Enable change-over? Available when stroke limitation is enabled Disabled Enabled Default value: Disabled According to the selected trigger (telegram or binary input), set the cooling or the heating mode. Change-over trigger Available when Change-over is enabled KNX telegram Default value: KNX telegram Select the source for the change-over. Binary input (Overrides binary input settings) Limited stroke when change-over is triggered Available when Change-over is enabled Range: Min: 250, Max: 8500 Default value: 6500 Unit: µm Override the limited stroke when the change-over is active. Continues on next page 5

Mode when change-over is triggered Available when Change-over is enabled Options : Cooling Heating Default value : Cooling Selected mode when the change-over is active. Parameters Maintenance Calibration at power on ne Full Fast Default value: Full Type of calibration done at power on. Automatic calibration refresh Never Weekly Monthly Default value: Weekly Perform a calibration at this frequency. Enable forced position? Disabled Enabled Default value: Disabled Enable the configuration of a forced position. Forced position Available when forced position is enabled Default value: 0 Value of the forced position. Parameters Binary input Activate binary input? Default value: Enable the binary input. 6

Binary input trigger Available when binary input is enabled Open Closed Default value: Open Set the triggered state of the binary input. Binary input action Available when binary input is enabled ne Go to position Default value: ne Select the action to take when the binary input is triggered (can additionally activate the change-over through the corresponding option). Binary input position Available when binary input action is set to Go to position Default value: 0 Set the position to reach when the binary input is triggered (and the Go to position option is selected). Periodic transmission of input state Available when binary input is enabled ne 1 min 2 min 5 min 10 min 15 min 20 min 30 min 45 min 60 min Default value: ne Transmit the binary input state at the selected frequency. Transmission on change (Only from firmware 0.2.0, KNX product catalogue 1.2) Available when binary input is enabled Options : Default value : Transmit the new binary input state on status change. Parameters Error Send status in case of error? Default value: Transmit the error status on the KNX bus when one appears. Continues on next page 7

On valve clogging, perform unblocking attempts Default value: If the valve is clogged, performs three attempts to unblock it. On valve clogging, move to fully open valve position Default value: If the valve is clogged, set the valve fully open. Forced error position Default value: 0 Depending on the selected options, move to this position when an error is detected. Move to error position on stroke detection failure Default value: Move to the defined position when a stroke detection failure happens. Move to error position on cyclic instruction timeout Default value: Move to the defined position when a cyclic instruction timeout happens. Move to error position on control value out of range Default value: Move to the defined position when the control value is out of range (for control values 0-10000). We reserve the right to introduce technical alterations without prior notice. 8 www.imi-hydronic.com