Recommendation T/CS (Vienna 1982) ANALOGUE SUBSCRIBER LINE TESTS AND MEASUREMENTS

Similar documents
) ,4)&2%15%.#9 053("544/. 3)'.!, 2%#%04)/. '%.%2!, 2%#/--%.$!4)/.3 /. 4%,%0(/.% 37)4#().'!.$ 3)'.!,,).'

Part IV: Glossary of Terms

)454 1 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

TSA 6000 System Features Summary

NATIONAL TELECOMMUNICATIONS AGENCY RESOLUTION Nº 238, NOVEMBER

Subscriber loop. Claude Rigault ENST FCN, 29/09/2002 Claude Rigault, ENST 1

Signalling In Telecom

ETSI ES V1.1.1 ( )

Compliance Requirements Overview 1

Part I: Requirements for Terminal Equipment (TE) and Related Access Arrangements Intended for Direct Connection to Analog Wireline Facilities

Line Signalling Fundamentals

- 1 - Rep. ITU-R M.2009 REPORT ITU-R M.2009 DIRECT-DIAL TELEPHONE SYSTEMS FOR THE MARITIME MOBILE SERVICE

Recommendation T/CS (Vienna 1982, revised in Montpelier 1984) SYSTEM L1 MULTIFREQUENCY PUSH-BUTTON INTERREGISTER SIGNALING

ETSI ES V1.2.1 ( )

Suppliers' Information Note. BT Metallic Path Facility. Interface Description

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

GENERAL CONSIDERATIONS ON TRANSMULTIPLEXING EQUIPMENTS. (Geneva, 1980; further amended)

Part VI: Requirements for ISDN Terminal Equipment

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

EG V1.1.1 ( )

Suppliers' Information Note. BT Public Switched Telephone Network (PSTN): Technical Characteristics Of The Single Analogue Line Interface

Suppliers' Information Note. BT Public Switched Telephone Network (PSTN): Technical Characteristics Of The Multi-Line Analogue Line Interface

SHARED TENANT SERVICE (STS) ARRANGEMENTS

ETSI TS V1.1.1 ( )

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"

Call Progress Tone and Ringing Signal Generation

TELECOMMUNICATION SWITCHING SYSTEMS STUDY NOTES

Product Guide Verizon Delaware LLC. Section 11 Delaware LLC Original Sheet 1. Channels

Supplement No Telephone PA P.U.C. - No. 14

M-980 General Purpose Call Progress Tone Detector

)454 / 03/0(/-%4%2 &/2 53% /. 4%,%0(/.%490% #)2#5)43 30%#)&)#!4)/.3 &/2 -%!352).' %15)0-%.4 %15)0-%.4 &/2 4(% -%!352%-%.4 /&!.!,/'5% 0!2!

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

Switched Access Service Section (A) Nonrecurring Charges Rate Reference. (1) Local Transport Installation

Exercise 1-4. Pulse Dialing

VHF LAND MOBILE SERVICE

International maritime VHF radiotelephone system with automatic facilities based on DSC signalling format

Investigation of Sensing for DTE Power Via MDI. Jennifer Rasimas, Stephen Jackson January 20, 2000

OUTLINE OF AUTOMATIC STEP BY STEP SYSTEM. The Telephone Dial 3. Subscribers' Calling Equipment 11. Typical Numbering Scheme 14

Silvertel. Ag1110 LOW COST SLIC

ETSI ES V1.1.1 ( )

Superseded by a more recent version INTERNATIONAL TELECOMMUNICATION UNION

INTERIM EUROPEAN I-ETS TELECOMMUNICATION January 1996 STANDARD

ETSI ES V1.2.1 ( )

INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES

Figure FXS Front Panel. Figure FXS Front Panel

DraftETSI EN V1.2.1 ( )

TS V1.1.1 ( )

Draft ETSI EN V1.3.1 ( )

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK

Draft ES V1.1.1 ( )

ETSI TS V1.1.1 ( )

RECOMMENDATION ITU-R F.756 * TDMA point-to-multipoint systems used as radio concentrators

Contents 1. FEATURES EQUIPMENT DESCRIPTION INSTALLATION OPERATION TROUBLESHOOTING SPECIFICATIONS...

Intermittent transient earth fault protection

W FXS LS/GS Channel Unit 600 Ohms

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

MH Data Access Arrangement Preliminary Information. Features. Description. Applications. Ordering Informations

M Precise Call Progress Tone Detector

DIAGRAM NOTES RELATING TO GBW GROUP SELECTOR FOR UAX NZ 13. Diagrams to be considered in conjunction with this circuit are :-

1.4 OPERATING INSTRUCTIONS

M V/5V General Purpose Call Progress Tone Detector INTEGRATED CIRCUITS DIVISION. Description. Features. Applications. Ordering Information

3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance

Product Guide Verizon Delaware LLC. Section 31 Delaware LLC Original Sheet 1. Connection With Certain Facilities of Others

3M Dynatel Far-End Device (FED II) Applications

ITS Information Technology Standardization (40) Contents. Page 1

)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

GDC 086R Issue 4, 10/17/97. Installation and Operation. Metroplex Flexi-Voice Plus Model MP General DataComm

EUROPEAN pr ETS TELECOMMUNICATION February 1996 STANDARD

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

VC-4/4A, VC-8/8A, VC-16

ACCESS SERVICE. 10. Special Federal Government Access Services General

ETSI TR V1.1.1 ( )

2 GHz Licence-exempt Personal Communications Service Devices (LE-PCS)

This document is designed to be used in conjunction with the CMX869A data sheet.

U. S. ARMY TEST AND EVALUATION COMMAND COMMODITY ENGINEERING TEST PROCEDURE

EUROPEAN ETS TELECOMMUNICATION February 1996 STANDARD

ETSI TR V1.1.1 ( )

CPC5712 INTEGRATED CIRCUITS DIVISION

Understanding Mixers Terms Defined, and Measuring Performance

T-1048 ISSUE 2 - ~ CARLSON TYPE C TEST TU. Operating Instruction

TELEPHONE TRANSMISSION SYSTEMS. ETI 2506 Telecommunication Systems

ICORE, INC. TARIFF F.C.C. NO. 2 6th Revised Page Cancels 5th Revised Page ACCESS SERVICE

The term Private Line Services includes the following:

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30

EUROPEAN ETS TELECOMMUNICATION January 1998 STANDARD

Wire Loop Signaling Repeater, Loop Start Only

DATASHEET HC5503T. Features. Applications. Ordering Information. Block Diagram. Balanced PBX/Key System SLIC, Subscriber Line Interface Circuit

Final draft ETSI ES V1.3.1 ( )

2 Grounding of power supply system neutral

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

TARIFF SECTION PAGE NUMBER

M Y R E V E A L - C E L L U L A R

TNA 102. Characteristics of the Spark Analogue Telephone Network Customer Interface. TNA 102: October 2017 DRAFT FOR COMMENT.

CHAPTER 17 THE TELEPHONE CIRCUIT # DEFINITIONS TERMS

Faculty of Engineering Electrical Engineering Department Communication Engineering I Lab (EELE 3170) Eng. Adam M. Hammad

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

Motorola MSC-241. Design and Deploy for MOTOTRBO Solutions EMEA.

The quality of the transmission signal The characteristics of the transmission medium. Some type of transmission medium is required for transmission:

INTERNATIONAL TELECOMMUNICATION UNION

Xen IPK II ANALOGUE TELEPHONE User Guide

Transcription:

o T/es 54-07 E B Page 1 Recommendation T/CS 54-07 (Vienna 1982) ANALOGUE SUBSCRIBER LINE TESTS AND MEASUREMENTS Recommendation proposed by Working Group T/No. 11 Switching and Signaling (CS) Text of the Recommendation adopted by the Telecommunications Commission: The European Conference of Postal and Telecommunications Administrations, considering that analogue subscriber lines are currently generally used and will continue to be used to a great extent in the foreseeable future; that on the basis of the defined maintenance philosophy, procedures for testing, measuring and monitoring, together with the field of application for subscriber line maintenance, all need to be specified; P that existing practice for analogue subscriber line maintenance shows a considerable variance in solutions; that system independent equipment, as well as the integration of some or all of these functions into digital local exchanges may be used, recommends that the members of the CEPT use for new exchanges, and/or system independent test and/or measurement equipment, the procedures for analogue subscriber line tests and measurements set-out below. GENERAL INTRODUCTION - FIELD OF APPLICATION This Recommendation covers the maintenance of an analogue subscriber connection. Referring to the Figure 1 (T/CS 54-07), three parts can be recognized in this connection: the subscriber set or STE (subscriber terminal equipment); the transmission part of the subscriber connection; the exchange terminal (ET). The ET can be situated in a local digital exchange or in a remote multiplexer or concentrator. Special categories of lines (e.g. party lines, analogue subscriber carrier systems, concentrators, service restrictions indicated by the presence of ground on one of the wires, etc.) are not covered in the present Recommendation. The test and/or measurement procedures to be used in such lines is for further study. ana[ogue telephony I subscriber s premises P line transmission serving loca[ exchange Figure 1 (T/CS 54-07). Parts of an analogue subscriber s connection. PART 1: OUTWARD TESTS AND MEASUREMENTS n This part of the Recommendation considers only the outward tests and measurements of the subscriber set and the subscriber line.

T/CS 54-07 E Page 2 1. GENERAL REQUIREMENTS 1.1. In order to adequately perform the tests of the subscriber set and subscriber line, the exchange must be capable of preventing disturbing influences from the exchange terminal to the line, e.g. by complete disconnection. 1.2. It must be possible to connect any subscriber line via an appropriate access to the test equipment, e.g. a metallic path. 1.3. It should be possible to initiate the tests and/or measurements and to receive the results locally or at a remote work position. For some tests and/or measurements, initiation will take place from the subscriber s premises. 1.4. With respect to the line tests and/or measurements, each subscriber s line will be in one of the following states: fault free line; line not tested; faulty line. A faulty line may be blocked or marked. The term blocked means that the line is blocked to calls due to a detected fault. The term marked means that the line has been indicated as faulty because of failure but is not blocked to calls. Only free lines will be able to be tested and/or measured by all the methods described in this Recommendation. When the line is not tested, the reason why it is not tested will be presented, except if the line is not installed. n. 1.5. When the subscriber line is tested or measured without the knowledge of the actual subscriber, the subscriber should be kept as unaware of these actions as possible (e.g. bell-ringing, clicks, etc.). 2. TEST AND/OR MEASUREMENT METHODS Three test and/or measurement methods can be distinguished: A. tests initiated from subscriber s premises (on demand, by dialling a special code); B. tests and/or measurements initiated from administration s premises (on demand, usually via a manmachine interface, e.g. control desk); C. automatic tests (automatic routine tests and/or measurements, automatic tests on a call-by-call basis). The choice of the applied procedure(s) (e.g. omitting the automatic tests on a call-by-call basis) depends on technical and economical considerations that can be different for each Administration according to the structure of the network and the organization of maintenance. It should be in accordance with a general maintenance philosophy. 3. TESTS INITIATED FROM THE SUBSCRIBER S PREMISES 3.1. These tests provide maintenance staff with the ability to access a ringback service from the subscriber s premises, in order to initiate some tests on the line and the terminal equipment. These tests should also be possible from any point in the local network, by means of a portable telephone set. The following call procedure could be adopted (needs further study): maintenance staff member dials a particular access code on the set to be tested; the exchange sends back a tone indicating whether the test equipment is available or not; the successive actions to off-hook and on-hook enable the different tests to be made. Note: The different test to be made could also be selected by differing access codes, determining individual test or groups of tests. 3.2. From the subscriber s premises, the following tests are implicit in the call procedure: 1. dial performance; 2. multifrequency keying performance; 3. test of bell functions.

T/CS 54-07 E Page 3 3.3. The following tests can also be provided optionally: 1. foreign DC and AC voltages; 2. insulation resistance; 3. power supply, current or loop resistance; 4. meter at subscriber s premises; 5. loop capacitance; 6. quality of speech transmission (telephonometry); 7. extensive MFPB or dial performance tests. 4. TESTS AND/OR MEASUREMENTS FROM ADMINISTRATION S PREMISES These detailed tests and/or measurements are initiated from local or remote man-machine terminals. They can be initiated after the examination of the fault reports resulting from previous automatic routine tests, previous automatic call-by-call tests or on the basis of subscriber complaints. They have priority over automatic routine tests. Lines with a permanent busy condition should be able to be tested and/or measured from Administration s premises. Where subscriber co-operation exists, a speech connection is assumed. When tests are being done without subscriber co-operation and the subscriber is making a call attempt, the tests or measurements should be aborted. They should also be aborted, if possible, when an incoming call is made to the subscriber line being tested. In the following, tests and/or measurements from the Administration s premises are identified. The actual tests to be performed, fault limits, the lines to be tested and the test moment(s) may be controlled by man-machine-communication. 4.1. Without co-operation at subscriber s premises: 1. foreign DC voltage: 2. foreign AC voltage: 3. insulation resistance: or to exchange battery b to ground or to exchange battery; the last two tests of point 3. above may be replaced by a to ground or to exchange battery, with b connected to a; 4. loop continuity: measurement of the capacitance a to b; 5. data for the localization of line faults; 6. test of the test access and the connection between the line and the ET. 4.2. With co-operation at the subscriber s premises: 1. dial performance: number of pulses received dial speed pulse ratio; 2. MFPB performance: digits received (Aj B, C, D included): go/no-go test only; in the case of a no-go result, the frequency, level and pulse length measurements can be optionally provided; 3. test of the meter at subscriber s premises; 4. payphone signals need further study; 5. call test, a functional test of the subscriber set: ringing, talking, listening; 6. test of the register-recall signal; 7. test of special conditions on the line, e.g. subscriber controlled service restrictions; 8. measurement of the loop resistance and/or feeding current. - It should be possible to define a basic subset of the tests under Section 4.1. which could be initiated by a single command.

TICS 54-07 E Page 4 For each on-demand test, the exact values of the measurements of the specified parameters should be presented, as well as the fault limits and a pass/fail indication. Before an on-demand test is made, a check to determine the presence of a call on the line should be performed. 5. AUTOMATIC ROUTINE TESTS AND MEASUREMENTS Automatic routine tests are performed on some or all subscriber lines at predetermined times, usually at night, e.g. once a week. Some specific automatic routine measurements which give more detailed and statistical information about the subscriber lines and associated local cable network may also be done. In this case, the measured value of all measured lines is presented and the frequency of these measurements may be lower. When the automatic routine test is applied on a call-by-call basis, it can be used for lines not previously tested and on lines found faulty during the call-by-call tests. Faulty lines should be tested periodically with an interval that can be changed by commands. A line which is found correct should no longer be stated faulty. The testing equipment should be able to recognize the state of the lines in use (see Section 1.4.). Spare (unused) lines need not be tested. During a test cycle covering all the lines, free lines are tested and busy lines are identified. After this test cycle, the lines previously identified as busy may be tested in a second test cycle. Each line can then be classified as correct, faulty or busy. At the end of the automatic routine test, a list is presented giving the directory and/or equipment number of the lines that are faulty or busy, and of the lines no longer stated faulty. The test limits and periods will also be indicated. When a subscriber initiates a call during a measurement testing on his line, the test or measurement should be aborted as soon as possible and in a way that causes minimum effect on the service offered to the subscriber, e.g. delay to dial tone, clicks on line, etc. When an incoming call is made to a subscriber line which is being tested or measured, the test or measurement should, if possible, be aborted too. The results of the automatic routine test are of the type go/no-go. However, the equipment should, in the case of automatic routine measurements, also be able to present the real measured value of the specified parameters. Further processing of such type of data, e.g. for more detailed or statistical information, need not necessarily be done by the line testing and/or measuring equipment itself. A faulty line should only be blocked in case of excessive AC or DC voltage detected on the line. The line testing equipment should automatically check itself, either periodically, or after a predetermined number of consecutive tests with results out-of-limit. Man-machine-communication facilities which may be local or remote must be provided in order to specify: the lines to be tested and/or measured; the start time and the frequency of tests and/or measurements; the subset of tests and/or measurements to be performed; the fault limits; the destination and presentation of the output. The following automatic routine tests and/or measurements are identified; however, the actual tests to be performed, fault limits, the lines to be tested and the test start time and frequency may be controlled by man-machine-communication. 1. foreign AC voltage: 2. foreign DC voltage: 3. insulation resistance: or to exchange battery b to ground or to exchange battery; the last two tests may be replaced by a to ground or to exchange battery, with b connected to a; 4. loop continuity: measurement of the capacitance a to b. The initial voltage tests should be compulsory, no further tests should be applied to lines failing the voltage tests. All measurements to ground refer to exchange ground.

T/CS 54-07 E Page 5 6. AUTOMATIC TEST ON A CALL-BY-CALL BASIS At every call set-up, a subscriber line testis performed, both on the calling (A-) and the called (B-) subscriber line. The test is performed after the seizure for the A-subscriber, before the dial tone for the B-subscriber, and before the ringing current is sent, or after clear-down for either A- or B-subscriber. The call-by-call test must be such that the network service performance and network technical performance parameters are met, e.g. dial tone delay. Lines which are found faulty should be either marked or blocked, depending upon the severity of the fault (see Section 1.4.). The following tests, on a call-by-call basis, should be provided. However, the tests to be performed, fault marking limits and fault blocking limits may be controlled by man-machine-communication. 6.1. Foreign voltage 1. foreign DC voltage: 2. foreign AC voltage: b to ground. 6.2. Insulation resistance 1. A-subscriber:, with b wire connected via the telephone set; 2. B-subscriber:, b to ground (this may be replaced by: a to ground, with b connected to a);. All measurements to ground refer to exchange ground. 7. PARAMETER VALUES In Tables 1 (T/CS 54-07) and 2 (T/CS 54-07), an overview of all tests and measurements is given. The ranges and accuracies for measurements are minimum requirements. When the value of the parameter is outside the provided range, an indication should be given. This indication should be an out-of-range indicator and/or the maximum or minimum value of this range. Note: The ranges mentioned, as compared to accuracy, are to specify the accuracy only and are not intended to specify the measuring sub-ranges of the actual equipment.

T/CS 54-07 E Page 6 Function Test and/or measurement methods Measuring range R and accuracy A Applicable test procedures State of STE la: to detect and measure foreign AC voltage Foreign AC voltage: - between aandb a to ground - b to ground R: 0-300 V r.m.s. a) 0-20 V: * 2V b) 20-300 V: + 10% of the real value 4., 5. and 6. On-, off-hook or 1b: to measure the transmission quality of a subscr. line Attenuation and (psophometric) noise measurements No value recommended 4. and 5. On-, off-hookor 2a: to measure loop capacitance (loop continuity test) Loop capacity between a and b R: 0-10 pf a) 0-0.5 pf: +50 nf b) 0.5-10 pf: + 10VO of the real value 4.2..5. and 6. On-hook 2b: to determine the geographical location of a loop interruption Loop capacity between a and b R: O-1 pf a) 0-0.05 pf: + 5 nf b) 0.05-1 KF: + 10% of the real value See Paragraph 4.2. 3: to detect and measure foreign DC voltage Foreign DC voltage: - between a and b - b to ground R: 100 to +100 V a) lto+l V: O.l V b) between 100 to lvand+lto +100v: + 10VO of real value 4., 5. and 6. On-, off-hook or 4a: to detect and measure line insulation failure Insulation resistance between a and b R: 0.01 M-1 M Ohm a) 0.01 M to 0.16 M Ohm: +8 k Ohm b) 0.16 M to 1 M Ohm: +5Y0 of real value 4.2..5. and 6. On-hook or 4b: to detect and measure line insulation failure Insulation resistance or to exchange battery, or or to exchange battery with b connected to a R: 100-10 M Ohm a) 100 k-160 k Ohm: +8k Ohm b) 160 k-10 M Ohm: * 5 % of real value See Paragraph 4.2. On-hook or 4C: to detect and measure loop resistance Loop resistance between a and b R: 10 Ohm to 10 k Ohm a) 10-100 Ohm + 10 Ohm b) 100-10 k Ohm: + 10% of the real value 4.2. and 6. Off-hook

TICS 54-07 E Page 7 / Function Test and/or mea- Measuring range Applicable State of STE surement methods R and accuracy A test procedures 1: to measure dial number of pulses R: 1-12 Go/no-go Off-hook performance received See Paragraphs 3. characteristics - dial speed R: 8-12 Hz and 4.2. A: 2 % relative pulse ratio R: 5-95~o A: 2% absolute 2: to measure digits received (A, R: according MFPB Go/no-go MFPB B, C and D coding See Paragraphs 6. performance included) and 4.2. characteristics frequencies R: 650-1660 HZ A: 0.2 % of the real value levels R: 5 dbmto 28 dbm A: 1 dbm pulse length Not applied Off-hook 3: to verify the Go/no-go tests of Go/no-go Off-hook correct operation the meter See Paragraphs 3. of the meter at and 4.2. subscriber s 4: to test STE call Functional test of See Paragraphs 3. functions the STE: and 4.2. ringing R: half nominal ringing Go/no-go current talking R: not measured, just Go/no-go listening manually tested register recall Go/no-go 5: to test and Number of pulses R: system-dependent Go/no-go measure received per coin See Paragraph 4.2. payphone coin unit pulsing Off-hook PART 2: INWARD TESTS This part of the Recommendation considers only the maintenance of the subscriber line termination (ET, including associated exchange functions). Depending on the grade of integration in the digital exchange, some of the tests and/or measurements described in this part of the Recommendation can be optional. 1. GENERAL REQUIREMENTS In order to adequately perform the tests and/or measurements of the ET, the exchange must be capable of preventing interferences from the line to influence the testing and/or measuring of the ET. It must be possible to connect any ET via an appropriate access to the test and/or measurement equipment, e.g. metallic path. It should be possible to initiate the tests and/or measurements and to receive the results either locally or at a remote work position. 2. TEST AND/OR MEASUREMENT PROCEDURES Two test and/or measurement procedures can be distinguished: on-demand tests and/or measurements; automatic routine tests. 3. ON-DEMAND TESTS AND/OR MEASUREMENTS These tests and/or measurements are initiated from local or remote measurement man-machine terminals. They can be initiated after the examination of fault reports resulting from the automatic routine tests or on the basis of subscriber complaints. They have priority over automatic routine tests.

T/CS 54-07 E Page 8 It must be possible to specify man-machine-communication: the ET to be tested (one or a specific group); the subset of tests to be performed (see Section 5). The simulation of a real call to another subscriber (test-connection) must be possible under man-machine control. For every on-demand test, the exact measured value will be issued, as well as the fault limits and a pass/fail indication. A failing test should not automatically block the ET. 4. AUTOMATIC ROUTINE TEST Automatic routine tests are performed on some or all ET at predetermined times, normally at night, e.g. once a week. With respect to the automatic routine test, the ET can be in one of the following states: fault free; busy (eventually permanent calling condition); faulty, The ET not yet allocated should not be tested. Two test cycles are performed. A first is applied on all free ETs, a second may be performed on the ET found busy during the first cycle. After that, a list of faulty and busy ETs is presented with indication of their directory and/or equipment number. For each faulty ET, the fault report will indicate the failing test (go/no-go indication). A faulty ET cannot be blocked by the test equipment. Man-machine-communication facilities, either local or remote, must be provided in order to specify: the ET to be tested; the time and the frequency of testing; the subset of tests to be performed (see Section 5.). It is admitted that an off-hook condition occurring on a line will not be detected by the associated ET on which the testing sequence is being performed. 5. LIST OF ET TESTS 5.1. Power feed The test equipment measures the feeding voltage. 5.2. Loop detector The reaction of the ET on the seizure signal (change of the loop from on-hook to off-hook) will be checked. The result of this test is a go/no-go result. 5.3. Ringing and ring trip The ringing, applied by the ET between a and b wires, is measured by the test equipment. After that, a check will be done to determine whether or not the ring trip function is executed (go/no-go result). As in Section 5.2., the check of the on-hook and off-hook detection capability is performed under worst case conditions (maximum loop resistance and minimum leakage resistance). 5.4. Metering test A metering command is given to the ET. A check will be done to determine whether or not a metering pulse appears on the metallic test path. The frequency, level and pulse duration will be measured. 5.5. Transmission test The purpose of this test is to check performance of the transmission path, including the codec. 5.6. Dial tone test A command to connect dial tone to the line is given to the ET. A check is performed to determine whether or not the dial tone appears.