NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Ultrasonic level indicator type INOWAFE

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster

solids ULTRASONIC LEVEL METERS FOR COMPACT TRANSMITTERS TWO-PART MEASURING SYSTEM EchoTREK NIVOSONAR Excellent sensor focusing: 5 total beam angle

SITRANS L Level instruments

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF)

Ultrasonic level transmitter, non-contact

Propagation of Electromagnetic Waves

Technologies, Solutions, and Applications. Guided Wave Radar for Level

ULTRASONIC LEVEL INDICATOR

INSTALLATION and PROGRAMMING MANUAL

HOW TO SELECT A CONTINUOUS LEVEL SENSOR WHITEPAPER

INSTRUCTION MANUAL FOR ULTRASONIC/MICROWAVE SENSORS

Level Measurement Products Installation Considerations-Radar

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

REFLEX RADAR INDICATOR

FOSTEN AUTOMATION SÉRIE F500-RD

Micropilot M FMR250. Technical Information

EchoTREK. S-300 compact ultrasonic level transmitter series for free flowing solids

Ultrasonic Level Transmitters (Optional Exercise)

Level Measurement With REFLEX RADAR

Sultan Liquid- Acoustic Wave Technology

Specification DataFile

Indholdsmåling Dalum Landbrugsskole Vejeevent 21. august 2018

HART PROFIBUS. EchoTREK ULTRASONIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

Level Measurement With REFLEX RADAR

U Series Non-Contact Ultrasonic Transmitter

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

INSTALLATION and PROGRAMMING MANUAL

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Princo Model L4660 Series SmartSonic for Free-Flowing Solids

SITRANS LR 300: High Performance Radar for Level Measurement

AccuSolar SOLAR POWERED SYSTEM

Princo Model L4660 Series Four-Wire SmartSonic Smart Narrow-Beam Ultrasonic Level transmitter

Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications

Continuous level measurement. The radar sensor for bulk solids VEGAPULS 69

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Ultrasonic Level Detection Technology. ultra-wave

Technologies, Solutions, and Applications. Level Switching

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Ultrasonic Level Transmitter.

Proximity Sensors Ultrasonic Precision Proximity Sensors

Global Water Instrumentation, Inc.

LST400 Ultrasonic level / open channel flow transmitter

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

prosonic T FMU230, FMU231

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

Ultrasonic level measuring device, non-contact

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

MK372/Ultrasonic Sensor System. Installation & Setting up Instructions. Comprising. MK372 Indicator/Controller Ultrasonic Transmitter

Xperience The Future in Level Measurements

THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Sonic Distance Sensors

EchoTREK. SE/SG-300 series two-wire compact ultrasonic level transmitters

2-wire level transmitter

Instruction Manual. Ultrasonic and Radar

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Ultrasonic level meters ULM 70

Effective Solids Level Measurement with Radar

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Serie NW - Acoustic Wave. Option list. Applications / Overview

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

Field Devices and Wiring

Level Measurement Techniques In A Modern Quarry

MB7760, MB7769, MB7780, MB7789

MP Series Radar Transmitter Installation & Operation Manual

U71/U73 Ultrasonic Transmitter

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Saab Tank Control representative:

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

Advanced instrumentation solutions crafted with highest precision

White Paper: Why use continuous level sensors?

PROGRAMMING MANUAL For SCA-3!!-4 models with HART

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

Operation. LEVEL Transmitters

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive

LST100 Ultrasonic level transmitter for upstream oil and gas

RCM DIRECT READING FLOWMETER

Ult r a s o n i c le v e l me t e r s ULM 70

No E. General Information. Ultrasonic Level Meters C O M PACT TRANSMITTERS T W O - PART MEASURING SYSTEM HITROL CO., LTD.

SSI Technologies - Application Note AT-AN1 Acu-Trac Ultrasonic Fluid Level Sensors Product Overview

Smart Radar Level Transmitter ALT6200 Overview Features Specification

ISO-9001:2015 certified PRODUCTS GUIDE. Aplus Finetek Sensor, Inc. More than just another level measurement company. Aplus Finetek Sensor, Inc.

Ultrasonic Transmitters vs. Guided Wave Radar for Level Measurement

AUTOMATION. Operator s Manual. DCR-1005 and DCR Rev. A4, 10/08 Doc

OEM radar transmitter, for aggressive media level measurement

*Based on a paper presented at the 49 th IEEE IAS-PCA Conference, Charleston, USA, 29 April 3 May 2007.

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.

Level Measurement Continuous level measurement Radar transmitters

Main features. Operation. LEVEL Transmitters

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Transcription:

(Part 4) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles, level measurement with the aid of pressure instruments was discussed. In the third part of this series of articles, radar level measurement basics and parameters affecting its efficiency were explained and in this section of these articles, level measurement with the aid of ultrasonic waves will be discussed. ULTRASONIC LEVEL MEASUREMENT BASICS Ultrasonic level instruments operate on the basic principle of using sound waves to determine liquid/ solid/slurries level. In addition to standard level or volume measurement, they can monitor open channel flow, determine the actual volumetric throughput in lift stations, measure differential level and control the pumps. Ultrasonic Level Transmitters consist of two elements; 1) a high efficiency transducer and, 2) an associated electronic transceiver. Together, they operate to determine the time for a transmitted ultrasonic pulse and its reflected echo to make a complete return trip between the non-contacting transducer and the sensed material level. As shown in Figure 16, a top-of-tank mounted transducer directs waves downward in bursts onto the surface of the material whose level is to be measured. A piezoelectric crystal inside the transducer converts electrical pulses into sound energy that travels in the form of a wave at the established frequency and at a constant speed in a given medium. Echoes of these waves return to the Min measuring distance (dead band) X m Figure16: Basic Concept and Elements of the Ultrasonic Level Measurement Close end blocking X M Max measurement range of the device Max measuring distance of the device Max measuring distance of the application (H) Programmed measurement range of the application Distance measured Level calculated Far end blocking Minimum measuring distance (X ): (also known as the Dead Band ) is a feature common to all m ultrasonic level meters. This is a short range in front of the sensor within which the ultrasonic device can not measure. Maximum measuring distance (X ): The longest range under ideal condition within which the device can M measure. No measurement is possible beyond this distance. 11 Indumart Inc.

transducer, which performs calculations to convert the distance of wave travel into a measure of level in the tank. The time lapse between firing the sound burst and receiving the return echo is directly proportional to the distance between the transducer and the material in the vessel. The medium is normally air over the material s surface but it could be a blanket of some other gases or vapours. The instrument measures the time for the bursts to travel down to the reflecting surface and return. This time will be proportional to the distance from the transducer to the surface and can be used to determine the level of fluid in the tank. This basic principle lies at the heart of the ultrasonic measurement technology and is illustrated in the equation: Distance = (Velocity of Sound x Time)/2. These noncontact devices are available in models that can convert readings into 4 20 ma outputs to DCSs, PLCs, or other remote controls. The frequency range for ultrasonic methods is in the range of 15...200 khz. The lower frequency instruments are used for more difficult applications; such as longer distances and solid level measurements and those with higher frequency are used for shorter liquid level measurements. For practical applications of ultrasonic measurement method, a number of factors must be considered. A few key points are: The speed of sound through the medium (usually air) varies with the medium s temperature. The transducer may contain a temperature sensor to compensate for changes in operating temperature that would alter the speed of sound and hence the distance calculation that determines an accurate level measurement. Temperature compensation is provided to account for uniform temperature variances of the sound medium. The temperature sensor is placed inside the transducer and the signal is sent to the transceiver via the transducer's wiring. Optionally, an alternate temperature sensor can be used to provide a temperature input, rather than by using the integral temperature sensor. If the temperature of the sound medium is to remain constant, instead of using either the integral temperature compensation or the remote sensor, the desired temperature may be entered during the transceiver configuration. The presence of heavy foam/dust on the surface of the material can act as a sound absorbent. In some cases, the absorption may be sufficient to preclude use of the ultrasonic technique. To enhance performance where foam/dust or other factors affect the wave travel to and from the liquid surface, some models can have a beam guide attached to the transducer. Extreme turbulence of the liquid can cause fluctuating readings. Use of a damping adjustment in the instrument or a response delay may help overcome this problem. The transceiver provides damping to control the maximum changing rate of the displayed material level and fluctuation of the ma output signal. Damping slows down the rate of response of the display especially when liquid surfaces are in agitation or material falls into the sound path during filling. Indumart Ultrasonic Level Transmitter is capable of monitoring virtually any short to medium range noncontact ultrasonic level measurements of most free flowing solids (granules and powders) and liquids. In applications characterized by dust, the instrument demonstrates notable stability by adjusting itself to the severity of the process. A definite advantage of some models of Indumart Ultrasonic Level Transmitter is their narrow total beam angle of 5 or 6 at -3 db. As a result of narrow beam angle, the emitted ultrasonic signal ensures outstanding focusing and good penetration trough dust, and furthermore, provides reliable measurements in narrow silos with uneven side walls and protruding objects (Fig. 17). 5 m 10 m 15 m 20 m r r = 22 cm r = 44 cm r = 66 cm r = 88 cm Figure17: Radii corresponding to 5 beam angle 12 Indumart Inc.

These transducer are virtually immune to buildups as condensation is atomized on contact with their highly active closed cell face. The lower frequency models operates in extremely hostile environment such as cement, sugar silos, stone crushers, gravel bins, etc. They incorporates current output directly or inversely proportional to the span. Remote programming of and acquiring information, such as viewing of the primary measurement values, from the transmitter are performed by a configuration software, which runs under Windows. Programmable system is usually recommended, which gives the opportunity to easily entering all configuration data, such as low and high level precisely without actual simulation, and to declare the severity of the process to optimize level measurements. Other features of the software include: (1) viewing of the measurement values on a computer via EXCEL application; (2) diagnosing the system with individual error message; (3) parameters read out, which reports on the operating conditions of the system to facilitate installation and troubleshooting. The optional RS485 with MODBUS protocol may also be acquired for monitoring, data acquisition and remote programming of the transmitter. The ultrasonic instrument with HART and the configuration software enables remote programming of up to 15 field devices and viewing of the primary measurement values on a PC. To avoid problems caused by repose formation of the solids, aiming (tilting) of the device is required. The aiming device for carrying out the most appropriate level measurement in tanks/silos is offered for most models. The programmer/display module (D400) may also be added to your level/volume measurement system to indicate the process value on its 6-digit display and be used to enable full parameter programming with access to all features of the LTU400 or LTU200 Series (Fig. 18). The bargraph display of this programmer provides visual information on the signal strength or the measurement value. These series features 32 point linearisation, over 10 pre-programmed tank shapes (Fig. 19) for calculation of volume/weight, as well as the ability to suppress the interface of an echo from a fixed object inside the container. Other features of them include: (1) access lock by secret code to prevent unauthorized access and programming; (2) fully self diagnostic system with individual error message for appropriate action; (3) service and test parameters read out, which reports on the operating conditions such as sensor gain, echo amplitude, noise level and more to facilitate the installation and troubleshooting of the system; (4) simulation mode, which is used for checking the instrument's output by simulating static or continuous change of level with selectable parameters such as low level, high level and cycle time; (5) revealing the device history such as total operating hours, operation after last switch-on, number of switching actions for each relay, minimum and maximum temperatures registered, etc. Other features of D400 are: two independent volume flow totalisers (one of them is resettable); trend monitoring and rate of level changing, temperature monitoring; individually coded error messages. Also, indication of the device history, such as total operating hours, time of operation after the last switch-on, minimum and maximum temperatures, etc. Five onboard multi-purpose relays are provided to be used as high/low alarms for level, flow rate or temperature. In addition, these relays may be used as pump control with automatic sequencing or be applied in many other control functions as the circuitry of the transceiver provides 14 modes of relay operations. Five LED's are also provided to indicate the alarm status. 3 ft ft in gal 3 m m cm I M US 8DIST LEV VOL FLOW % ma c 8 8 8 8 8 PROG RELAY T1 T2 FAIL F sec min hour day COM ECHO INDUMART Canada Figure 18: D400 Display and programming module Figure 19: Pre-programmed tank shapes 13 Indumart Inc.

The optional remote display with 2 contacts (DIS300) may also be added to your level measurement system to indicate the process value on its 4-digit display and be used to trigger contacts at desirable material levels. Applying Indumart Ultrasonic Level Measurement instruments has been proven to be reliable with little maintenance, where other high maintenance level detectors are not preferred because of their negative field experience. Their performance is based on self-adjusting circuitry which analyzes the transducer signals through its software process and provides achievable accuracy. In applications characterized by dust, turbulence and steam, or in vessels with agitation, these instruments demonstrate notable stability by adjusting themselves to the severity of the process. Range In Liquids 0.1 ~ 1.8 m (0.4 ~ 6 ft) Resolution 0.7 mm (0.03") Frequency 148 khz Figure20: LTU102 Figure21: LTU200 Series Model Transducer Material Max. Distance (m) Min. Distance (m) Total Beam Angle Frequency (khz) Process Connection LTU203 LTU204 LTU205 LTU206 LTU207 LTU208 LTU210 LTU212 LTU215 PTFE PP, PVFD PP, PTFE PTFE 316 St. St. PP, PVFD PP, PVFD 316 St. St. PVFD PP, PVFD 3 4 5 6 7 8 10 12 15 0.2 0.2 0.25 0.25 0.35 0.4 0.35 0.35 0.45 0.55 6 6 5 5 7 5 7 5 5 5 80 80 80 80 50 60 50 60 40 40 1½" Thread 1½" Thread 2" Thread 2" Thread Flush Flange 2" Thread Flange Flush Flange Flange 14 Indumart Inc.

Model Range in Liquid Resolution Mounting LTU315 (52 khz) LTU309 (70 khz) LTU306 (80 khz) LTU305 (81 khz) 0.3 ~ 15 m 5.7mm (0.23") 0.25 ~ 9 m 3.4mm (0.13") 0.2 ~ 6 m 2.2mm (0.088") 0.2 ~ 5 m 1.8mm (0.07") 3" & 1½" NPT LTU303 (148 khz) 0.12 ~ 2.7 m 0.98mm (0.04") 3" & 1" NPT Figure22: LTU300 Series Figure23: LTU400 Series Mounting (min. flange) Frequency For Solids Type LTU415 LTU430 LTU460 ANSI 6" / DN150 ANSI 6" / DN150 ANSI 12" / DN300 Max. Measuring Distance* 15 m (49 ft) 30 m (98 ft) 60 m (196 ft) Min. Measuring Distance 0.6 m (2 ft) 0.6 m (2 ft) 1 m (3.33 ft) Suggested Applications * from transducer's face - under optimal conditions Recommended for short range monitoring of up to 8 m Up to 25 m for powder and heavy dusty granules; higher range for non-dusting granules Up to 50 m for powder and heavy dusty granules; higher range for non-dusting granules 30 khz 30 khz 15 khz For Solids & Liquids Model Range in Solid Resolution Mounting LTU515 (25 khz) LTU510 (45 khz) 0.4...15 m 10 mm (0.41") 0.3...10 m 6.8 mm (0.27") 6" NPT 3" NPT Figure24: LTU500 Series 15 Indumart Inc.