DATE: 10 February 2010 I.T.L. (PRODUCT TESTING) LTD. CE EMC Test Report. for. MAXIMUM Security (1984) Ltd. Equipment under test:

Similar documents
Satec Ltd. 3-Phase Power Meter PM135

Test Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd.

Galcon Galil Control

DATE: 25 September 2012 I.T.L. (PRODUCT TESTING) LTD. FCC EMC Test Report. (Equipment Authorization Under FCC Verification Process) for

CERTIFICATE OF COMPLIANCE

FCC Radio Test Report. Orpak Systems Ltd.

FCC Radio Test Report

2620 Modular Measurement and Control System

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

TRANSMITTER MODEL: KAS-2030M

Test Report GUANGDONG EAST POWER CO., LTD

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

STC Test Report. Date : Page 1 of 13 No. : HM161169

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

FCC Part 15 Subpart B

EMC Test Report. Report Number: M030826

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

TEST REPORT... 1 CONTENT...

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC Test report for LED Panel Light Models , , , , ,

EMC COMPLIANCE TEST REPORT

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

Electrical HERMON LABORATORIES

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

King Pigeon Communication Co., Limited

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Sunlight Supply, Inc.

FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

FCC 47 CFR PART 15 SUBPART B

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

PARTIAL RADIATED EMISSIONS AND RADIATED IMMUNITY TEST REPORT

T A B L E O F C O N T E N T S DESCRIPTION PAGE

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

C E R T I F I C A T I O N

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

EMC TEST REPORT. Report No.: CE10-LIE040101E

CE TEST CERTIFICATION

FCC Verification TEST REPORT

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

1 Introduction Test Specification Environment Relevant standards Emissions Immunity...

C E R T I F I C A T I O N

Test and Measurement for EMC

FCC CLASS B COMPLIANCE REPORT (DoC)

TEST REPORT. Issued for:

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

r(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

C E R T I F I C A T I O N

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

1 SUMMARY OF STANDARDS AND RESULTS

EMC VERIFICATION SUMMARY Report No.: SZHH

Electromagnetic Compatibility

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

CE TEST CERTIFICATION

TÜV SÜD Canada Inc. 11 Gordon Collins Dr, Gormley, ON, L0H 1G0 Canada Ph: (905) Testing Laboratory Certificate #

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

f02 January 11, TÜV Rheinland Nederland B.V. P.O. Box AA Leek (NL) Eiberkamp VT Leek (NL)

Transcription:

DATE: 10 February 2010 I.T.L. (PRODUCT TESTING) LTD. CE EMC Test Report for MAXIMUM Security (1984) Ltd. Equipment under test: MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 See customer s declaration/statement on page 5 for additional models/subconfigurations covered by this test report. Written by: Y. Raz, Documentation Approved by: Y. Mordukhovitch, Test Engineer Approved by: I. Raz, EMC Laboratory Manager This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 1 of 59

TABLE OF CONTENTS 1. GENERAL INFORMATION ------------------------------------------------------------------------------- 3 1.1 Administrative Information... 3 1.2 Abbreviations and Symbols... 5 1.3 List of Accreditations... 6 2. APPLICABLE DOCUMENTS ---------------------------------------------------------------------------- 7 3. TEST SITE DESCRIPTION ------------------------------------------------------------------------------- 8 3.1 Location... 8 3.2 Open Test Site... 8 3.3 Antenna Mast... 8 3.4 Turntable... 8 3.5 EMI Receiver... 8 3.6 Test Equipment... 8 4. SUMMARY OF TEST RESULTS ------------------------------------------------------------------------ 9 5. EQUIPMENT UNDER TEST (E.U.T.) DESCRIPTION -------------------------------------------- 10 6. LIST OF TEST EQUIPMENT ---------------------------------------------------------------------------- 14 6.1 Immunity Tests... 14 6.2 Emission Tests... 15 7. E.U.T. PERFORMANCE VERIFICATION ------------------------------------------------------------ 16 7.1 Mode of Operation... 16 7.2 Monitoring of E.U.T.... 16 7.3 Definition of Failure... 16 8. RADIATED EMISSION ----------------------------------------------------------------------------------- 17 8.1 Test Specification... 17 8.2 Test Procedure... 17 8.3 Test Results... 17 9. IMMUNITY TO ELECTROSTATIC DISCHARGE -------------------------------------------------- 22 9.1 Test Specification... 22 9.2 Test Procedure... 22 9.3 Test Results... 22 10. IMMUNITY TO RADIATED FIELD --------------------------------------------------------------------- 45 10.1 Test Specification... 45 10.2 Test Procedure... 45 10.3 Test Results... 45 11. IMMUNITY TO ELECTRICAL FAST TRANSIENT / BURST ------------------------------------ 47 11.1 Test Specification... 47 11.2 Test Procedure... 47 11.3 Test Results... 47 12. IMMUNITY TO CONDUCTED DISTURBANCES -------------------------------------------------- 49 12.1 Test Specification... 49 12.2 Test Procedure... 49 12.3 Test Results... 49 13. SET UP PHOTOGRAPHS ------------------------------------------------------------------------------- 52 14. SIGNATURES OF THE E.U.T'S TEST ENGINEERS --------------------------------------------- 55 15. APPENDIX A - CORRECTION FACTORS ---------------------------------------------------------- 56 15.1 Correction factors for CABLE... 56 15.2 Correction factors for Amplifier 8447F 30M-1.3G GAIN... 57 15.3 Correction factors for Bilog ANTENNA... 58 16. APPENDIX B - MEASUREMENT UNCERTAINTY ------------------------------------------------ 59 16.1 Radiated Emission... 59 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 2 of 59

1. General Information 1.1 Administrative Information Manufacturer: MAXIMUM Security (1984) Ltd. Manufacturer's Address: 201 Levi Eshkol St. Kiryat Ono, 55400 Israel Tel: +972-3-634-9851 Fax: +972-3-634-9775 Manufacturer's Representative: Daniel Attias Equipment Under Test (E.U.T): Equipment Model No.: Equipment Serial No.: MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 (See customer s declaration/statement on following page for additional model/sub-configurations names). Date of Receipt of E.U.T: 23.11.09 Start of Test: 23.11.09 End of Test: 27.01.10 Test Laboratory Location: I.T.L (Product Testing) Ltd. 1 Batsheva St., Lod ISRAEL 71100 Test Specifications: See Section 2 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 3 of 59

Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 4 of 59

1.2 Abbreviations and Symbols The following abbreviations and symbols are applicable to this test report: A/m AC AM ARA Aux Avg CDN cm db dbm dbμv dbμv/m DC EFT/B EMC ESD E.U.T. GHz HP Hz khz kv LED LISN m mhn MHz msec N/A per QP PC RF RE sec V V/m VRMS ampere per meter alternating current amplitude modulation Antenna Research Associates auxiliary average coupling-decoupling network centimeter decibel decibel referred to one milliwatt decibel referred to one microvolt decibel referred to one microvolt per meter direct current electrical fast transient/burst electromagnetic compatibility electrostatic discharge equipment under test gigahertz Hewlett Packard Hertz kilohertz kilovolt light emitting diode line impedance stabilization network meter millihenry megahertz millisecond not applicable period quasi-peak personal computer radio frequency radiated emission second volt volt per meter volts root mean square Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 5 of 59

1.3 List of Accreditations The EMC laboratory of I.T.L. is accredited by the following bodies: 1. The American Association for Laboratory Accreditation (A2LA) (U.S.A.), Certificate No. 1152.01. 2. The Federal Communications Commission (FCC) (U.S.A.), Registration No. 861911. 3. The Israel Ministry of the Environment (Israel), Registration No. 1104/01. 4. The Voluntary Control Council for Interference by Information Technology Equipment (VCCI) (Japan), Registration Numbers: C-1350, R-1285. 5. Industry Canada (Canada), IC File No.: 46405-4025; Site No. IC 4025A-1. 6. TUV Product Services, England, ASLLAS No. 97201. 7. Nemko (Norway), Authorization No. ELA 207(b). I.T.L. Product Testing Ltd. is accredited by the American association for Laboratory Accreditation (A2LA) and the results shown in this test report have been determined in accordance with I.T.L.'s terms of accreditation unless stated otherwise in the report. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 6 of 59

2. Applicable Documents 2.1 EMC Directive: 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC 2.2 EN 61000-6-3: 2007 Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments 2.3 EN 50130-4: 1995 Amendment A1: 1998 Amendment A2: 2003 Alarm systems Part 4:Electromagnetic compatibility Product family standard: Immunity requirements for components of fire, intruder and social alarm systems 2.4 IEC 61000-4-2: 1995 Electromagnetic Compatibility (EMC), Part 4: Testing and Measurement Techniques; Section 2: Electrostatic discharge immunity test: Basic EMC publication. 2.5 IEC 61000-4-3: 1996 Electromagnetic Compatibility (EMC), Part 4: Testing and Measurement Techniques; Section 3: Radiated, radio frequency, electromagnetic field immunity test. 2.6 IEC 61000-4-4: 1995 Electromagnetic compatibility (EMC), Part 4. Testing and measurement techniques; Electrical fast transient /burst immunity test, Basic EMC Publication. 2.7 IEC 61000-4-6: 1996 Electromagnetic Compatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 7 of 59

3. Test Site Description 3.1 Location Radiated Emission tests were performed at the Electromagnetic Compatibility Test Facility of I.T.L. (PRODUCT TESTING) LTD. located at Kfar Bin Nun, Israel 99780 Telephone: + 972-8-9797799, Fax: + 972-8-9797702 3.2 Open Test Site Consists of 3 meter and 10 meter ranges, using a 7x14 meter solid metal ground plane, a remote controlled turntable and an antenna mast. The turntable and the tested equipment that is placed on it are environment protected. All the power, control and signal lines are routed under the ground plane. 3.3 Antenna Mast AAM-4/A, manufactured by Antenna Research Associates (ARA). The antenna position and polarisation are remotely controlled via Fibre Optical Link using ARA Dual Controller ACU-2/5, and pressurised air. The antenna position is adjustable between 1-4 meters. 3.4 Turntable ART-1001/4, manufactured by ARA. The position of the turntable is remotely controlled via a Fibre Optic Link, using ARA Dual Controller ACU-2/5. The turntable is mounted in a pit and its surface is flush with the Open Site Ground Plane. 3.5 EMI Receiver HP8542E, including HP85420E R.F. filter manufactured by Hewlett-Packard, being in full compliance with CISPR 16 requirements. 3.6 Test Equipment See details in Section 6. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 8 of 59

4. Summary of Test Results Test Radiated Emissions EN 61000-6-3: 2007 Class B Results The E.U.T met the performance requirements of the specification. The margin between the emission level and the specification limit is 3.4 db in the worst case at the frequency of 55.26 MHz, horizontal polarization. ESD IEC 61000-4-2: 1995 Air Discharge, 8kV Contact Discharge, 6kV The E.U.T met the performance requirements of the specification. Radiated Immunity IEC 61000-4-3: 1996 (80-2000 MHz) 10 V/m, 80% A.M. by 1kHz Pulse Modulated, 1Hz, The E.U.T met the performance requirements of the specification. EFT/B IEC 61000-4-4: 1995 1kV DC Power Lines The E.U.T met the performance requirements of the specification. Conducted Disturbances IEC 61000-4-6: 1996 (0.15-100 MHz) 10 VRMS, 80% A.M. by 1kHz Pulse Modulated by 1Hz The E.U.T met the performance requirements of the specification. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 9 of 59

5. Equipment Under Test (E.U.T.) Description Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 10 of 59

Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 11 of 59

Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 12 of 59

Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 13 of 59

6. List of Test Equipment 6.1 Immunity Tests Equipment indicated below by an X used in Tests IEC 61000-4:-2,-3,-4,-5,-6,-8,-11. Test equipment calibration is in accordance with ITL Q.A. Procedure PM 110, "Calibration Control Procedure", which complies with ISO 9002 and ISO/IEC Guide 17025. Instrument Manuf. Model Serial No. Used in Test IEC 61000-4: -2-3 -4-5 -6-8 -11 Transient Generator KeyTek CEMASTER 9612436 X ESD Simulator KeyTek MiniZap 15/EC 9512290 X Isotropic Field Probe AR EP-2080 23190 X Signal Generator HP 8657A 2849U01094 X X RF Amplifier AR 100W1000M1 19842 X Isotropic Field Monitor AR FM-2000 19719 X Biconilog Antenna EMCO 3142B 1078 X Horn Antenna A.H. systems SAS 200/571 199 X BulkF Current Probe FCC F-120-9 105 X RF Amplifier AR 500A100 19896 X Transient Wave- form Monitor CDI TWM-100 3233 Phase Control Amplifier CDI PCA-1000 3217 Single Phase Isolated Backfilter CDI CDI-1kVA 3221 Surge Generator CDI CDI-1000i 3153 1.2/50; 8/20usec AC Surge Unit KeyTek E551 9512398 Surge Generator EM TEST UCS 500-M 1198-45 AC Power Source EM TEST UCS 500-M 1198-45 Current Generator FCC F-1000-4-8-125A 9838 Magnetic Loop FCC F-1000-4-8/9/10- L-1M 9836 RF Amplifier AR 25S1G4 23102 RF Amplifier AR 20T4G18 21296 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 14 of 59

6.2 Emission Tests The equipment indicated below by an X was used for testing Conducted Emission (CE), Radiated Emission (RE), and IEC 61000-3-2;3 Test equipment calibration is in accordance with ITL Q.A. Procedure PM 110 "Calibration Control Procedure", which complies with ISO 9002 and ISO/IEC Guide 17025. Used in Test Instrument Manufacturer Model Serial No. CE RE -2-3 LISN EMCO 3810/2BR 1297 Transient Limiter HP 11947A 3107A03041 RF Amplifier HP 8447F 3113A06386 X Current Probe FCC F51 163 EMI Receiver HP 8546A 3650A00365 X Receiver RF Filter Section HP 85460A 3650A00365 X EMC Analyzer HP HP8593 3536A00120 X Biconilog Antenna EMCO 3142B 1250 X Horn Antenna ETS 3115 6142 X Antenna Mast ETS 2070-2 ETS X Turntable ETS 2087 ETS X Mast & Table Controller ETS/EMCO 2090 ETS/EMCO X Power Analysis System EM Test DPA 500 0501/09 AC Power Source EM Test ACS 500 1101/01 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 15 of 59

7. E.U.T. Performance Verification 7.1 Mode of Operation The E.U.T. was tested in standby mode. Before and after the immunity tests the functional test for each unit was performed. 7.2 Monitoring of E.U.T. Figure 1. Test Set-up The yellow and red indicators were observed during and after the immunity tests. During Radiated Immunity and conducted disturbances tests, the E.U.T.s were observed via CCTV, indication LEDs were connected to the E.U.T.s outputs. 7.3 Definition of Failure 1. For all the tests, except Radiated Immunity test: Four synchronous blinking for the red and yellow indicators. 2. For Radiated Immunity test: ON position of the indication LEDs during 2sec. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 16 of 59

8. Radiated Emission 8.1 Test Specification 30-1000 MHz, EN 61000-6-3: 2007, CLASS B 8.2 Test Procedure The E.U.T operation mode and test set-up are as described in section 7.1. A preliminary measurement to characterize the E.U.T was performed inside the shielded room. The preliminary measurements produced a list of the highest emissions. The E.U.T was then transferred to the open site, and placed on a remotecontrolled turntable. For table-top products, the E.U.T was placed on a non-metallic table, 0.8 meters above the ground. For floor-standing products, the E.U.T. was placed directly on the horizontal ground plane, but was separated from metallic contact with the ground plane by up to 15 cm of insulation. The effect of varying the position of the cables was investigated to find the configuration that produces maximum emission.. The configuration tested is shown in Figure 33. Radiated Emission Test. The frequency range 30-1000 MHz was scanned, and the list of the highest emissions was verified and updated accordingly. The emissions were measured using a computerized EMI receiver complying to CISPR 16 requirements. The specification limits and applicable correction factors are loaded to the receiver via a 3.5" floppy disk. The readings were maximized by adjusting the antenna height between 1-4 meters, the turntable azimuth between 0-360, and the antenna polarization. Verification of the E.U.T emissions was based on the following methods: Turning the E.U.T on and off. Using a frequency span less than 10 MHz. Observation of the signal level during turntable rotation. Background noise is not affected by the rotation of the E.U.T. The emissions were measured at a distance of 3 meters. 8.3 Test Results The E.U.T met the requirements of the EN 61000-6-3: 2007, Class B specification requirements. The margin between the emission level and the specification limit is 3.4 db in the worst case at the frequency of 55.26 MHz, horizontal polarization. The details of the highest emissions are given in Figure 2 to Figure 5. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 17 of 59

Radiated Emission E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: EN 61000-6-3: 2007, Class B Antenna Polarization: Horizontal Antenna: 3 meters distance Frequency range: 30 MHz to 1000 MHz Detectors: Peak, Quasi-peak Figure 2. Radiated Emission. Antenna Polarization: HORIZONTAL. Detectors: Peak, Quasi-peak Note: QP Delta refers to the test results obtained minus specified requirement; thus a positive number indicates failure, and a negative result indicates that the product passes the test. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 18 of 59

Radiated Emission E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: EN 61000-6-3: 2007, Class B Antenna Polarization: Horizontal Antenna: 3 meters distance Frequency range: 30 MHz to 1000 MHz Detectors: Peak, Quasi-peak Figure 3. Radiated Emission. Antenna Polarization: HORIZONTAL Detectors: Peak, Quasi-peak Note: 1. Horizontal axis shows logarithmic frequency scale. 2. The vertical axis shows amplitude (in db µv/m). 3. Peak detection is designated by the top of each vertical line. 4. Quasi-peak detection is designated by the first dash mark (from the top) of each vertical line. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 19 of 59

E.U.T Description Radiated Emission MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: EN 61000-6-3: 2007, Class B Antenna Polarization: Vertical Antenna: 3 meters distance Frequency range: 30 MHz to 1000 MHz Detectors: Peak, Quasi-peak Figure 4. Radiated Emission. Antenna Polarization: VERTICAL. Detectors: Peak, Quasi-peak Note: QP Delta refers to the test results obtained minus specified requirement; thus a positive number indicates failure, and a negative result indicates that the product passes the test. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 20 of 59

Radiated Emission E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: EN 61000-6-3: 2007, Class B Antenna Polarization: Vertical Antenna: 3 meters distance Frequency range: 30 MHz to 1000 MHz Detectors: Peak, Quasi-peak Figure 5. Radiated Emission. Antenna Polarization: VERTICAL. Detectors: Peak, Quasi-peak Note: 1. Horizontal axis shows logarithmic frequency scale. 2. The vertical axis shows amplitude (in db µv/m). 3. Peak detection is designated by the top of each vertical line. 4. Quasi-peak detection is designated by the first dash mark (from the top) of each vertical line. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 21 of 59

9. Immunity to Electrostatic Discharge 9.1 Test Specification IEC 61000-4-2: 1995 9.2 Test Procedure The E.U.T. was set up on a wooden support 0.1m high above the reference ground plane. The test setup is illustrated in the photograph, Figure 34. Immunity to Electrostatic Discharge Test. Photographs in Figure 6 to Figure 27 show the locations of test points. 9.2.1 Air Discharge Potentials of 2, 4 and 8 kv were applied near each applicable test point. At places where discharge occurred, the potential was applied twenty times; ten times negative and ten times positive. The E.U.T.'s performance during the test was verified as detailed in Section 7. 9.2.2 Contact Discharge Potentials of 2, 4, and 6 kv were applied to each applicable test point. In places where discharge occurred, the potential was then applied twenty times; ten negative and ten positive discharges. The E.U.T.'s performance during the test was verified as detailed in Section 7. 9.2.3 Indirect Discharge (vertical and horizontal coupling plane) Potentials of 2, 4, and 6 kv were applied to the center of the vertical edge of the coupling plane at a distance of 0.1 meters from the outer casing of the E.U.T. to each applicable test point. The potential was applied 10 times for each polarity, to each location of the coupling plane. All four faces of the E.U.T. were completely illuminated. An ESD of the same characteristics as for the vertical coupling plane was applied to the horizontal coupling plane, at each side of the E.U.T., at a distance of 0.1 meter from it's outer casing. Additional details are shown in Figure 5 of IEC 61000-4-2: 1995. The E.U.T.'s performance during the test was verified as detailed in Section 7. 9.3 Test Results The E.U.T met the requirements of specification IEC 61000-4-2: 1995. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 22 of 59

Immunity to Electrostatic Discharge E.U.T Description MULTI-ZONE Specification: IEC 61000-4-2: 1995 Air Figure 6. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 23 of 59

Immunity to Electrostatic Discharge E.U.T Description MULTI-ZONE Specification: IEC 61000-4-2: 1995 Air Figure 7. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 24 of 59

Immunity to Electrostatic Discharge E.U.T Description OUT-SMART Specification: IEC 61000-4-2: 1995 Air Figure 8. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 25 of 59

Immunity to Electrostatic Discharge E.U.T Description OUT-SMART Specification: IEC 61000-4-2: 1995 Air Figure 9. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 26 of 59

Immunity to Electrostatic Discharge E.U.T Description GUARD Specification: IEC 61000-4-2: 1995 Air Figure 10. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 27 of 59

Immunity to Electrostatic Discharge E.U.T Description GUARD Specification: IEC 61000-4-2: 1995 Air Figure 11. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 28 of 59

Immunity to Electrostatic Discharge E.U.T Description OUT-LOOK Specification: IEC 61000-4-2: 1995 Air Figure 12. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 29 of 59

Immunity to Electrostatic Discharge E.U.T Description OUT-LOOK Specification: IEC 61000-4-2: 1995 Air Figure 13. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 30 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN-FLT Specification: IEC 61000-4-2: 1995 Air Figure 14. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 31 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN Specification: IEC 61000-4-2: 1995 Air Figure 15. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 32 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN-2PM Specification: IEC 61000-4-2: 1995 Air Figure 16. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 33 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN-2PM Specification: IEC 61000-4-2: 1995 Air Figure 17. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 34 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN Specification: IEC 61000-4-2: 1995 Air Figure 18. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 35 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN Specification: IEC 61000-4-2: 1995 Air Figure 19. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 36 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN-MINI Specification: IEC 61000-4-2: 1995 Air Figure 20. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 37 of 59

Immunity to Electrostatic Discharge E.U.T Description CURTAIN-MINI Specification: IEC 61000-4-2: 1995 Air Figure 21. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 38 of 59

Immunity to Electrostatic Discharge E.U.T Description VIBRA-SENS Specification: IEC 61000-4-2: 1995 Air Air Figure 22. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 39 of 59

Immunity to Electrostatic Discharge E.U.T Description VIBRA-SENS Specification: IEC 61000-4-2: 1995 Air Air Figure 23. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 40 of 59

Immunity to Electrostatic Discharge E.U.T Description DIGITAL-KEY Specification: IEC 61000-4-2: 1995 Air Figure 24. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 41 of 59

Immunity to Electrostatic Discharge E.U.T Description DIGITAL-KEY Specification: IEC 61000-4-2: 1995 Air Figure 25. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 42 of 59

Immunity to Electrostatic Discharge E.U.T Description RM-1 Specification: IEC 61000-4-2: 1995 Air Air Air Figure 26. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 43 of 59

Immunity to Electrostatic Discharge E.U.T Description RM-1 Specification: IEC 61000-4-2: 1995 Air Air Figure 27. ESD Test Points Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 44 of 59

10. Immunity to Radiated Field 10.1 Test Specification IEC 61000-4-3: 1996 10.2 Test Procedure The E.U.T. was subjected to a field of 10V/m, amplitude modulated 80% by a 1kHz and pulse modulated by 1 Hz sinusoidal signal. The Radiated Field was applied in vertical and horizontal polarization using a Biconilog antenna in the frequency range of 80-2000 MHz. The Radiated Field was calibrated and tested for uniformity in accordance with Section 6.2 of IEC 61000-4-3. The calibration values for the driver signal generator were based on the data given in I.T.L. "Radiated Immunity Calibration Test Report" No. PM-112R-IMM. The frequency was swept using discrete increments having a value less than 1% of the fundamental frequency. The performance of the E.U.T. was verified during the test as described in Section 7. The test setup is illustrated in the photograph, Figure 35. Immunity to Radiated Field Test. The tests were performed three times, each time in a different direction (3 orthogonal positions). See Figure 28 below. Figure 28. Relative Orientations of the E.U.T. and the Field Vectors 10.3 Test Results The E.U.T. passed the Radiated Immunity Tests as required by specifications: IEC 61000-4-3: 1996 For additional information see Figure 29. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 45 of 59

Radiated Immunity E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: IEC 61000-4-3: 1996, 80-2000 MHz Amplitude Modulation: 80% AM by 1 khz Frequency (MHz) Antenna Polarity Specification PASS / (V/m) FAIL From To 80 2000 Horizontal 10.0 Pass 80 2000 Vertical 10.0 Pass Immunity Threshold (V/m) Specification: IEC 61000-4-3: 1996, 80-2000 MHz (Pulse Modulated Signal 1Hz) Frequency (MHz) Antenna Polarity Specification PASS / (V/m) FAIL From To 80 2000 Horizontal 10.0 Pass 80 2000 Vertical 10.0 Pass Immunity Threshold (V/m) Figure 29. Immunity to Radiated Field Note: The dwell time for each frequency was 5 seconds. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 46 of 59

11. Immunity to Electrical Fast Transient / Burst 11.1 Test Specification IEC 61000-4-4: 1995 11.2 Test Procedure The E.U.T. was placed 0.1 m above a reference ground plane. The EFT/B generator was placed on, and grounded to, this ground plane. See the photograph, Figure 36. Immunity to Electrical Fast Transient / Burst Test. A test signal having the waveform described in Figure 37. Transient Waveforms was applied to the DC lines of the E.U.T mains input, at a distance of 1 meter from the E.U.T. The test signal voltage was 1 kv and it was applied for 1 minute to each line, in negative and positive polarities. The same test signal was applied to the signal lines (as applicable), that are connected to the E.U.T. The voltage level was 1 kv. Applicable signal and control lines should have a length greater than 3m. 11.3 Test Results The E.U.T. passed the immunity to electrical fast transients / bursts requirements as detailed by specification IEC 61000-4-4: 1995 Additional details are given in Figure 30. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 47 of 59

Electrical Fast Transient / Burst E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: IEC 61000-4-4: 1995 [ x ] Positive Polarity [ x ] Negative Polarity CAPACITIVE CLAMP TEST POINT PASS / FAIL ANOMALY SPECIFICATION (kv) DC line + Pass No anomaly 1.0 DC line - Pass No anomaly 1.0 THRESHOLD (kv) Figure 30. Immunity to Electrical Fast Transient / Burst Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 48 of 59

12. Immunity to Conducted Disturbances 12.1 Test Specification IEC 61000-4-6: 1996 12.2 Test Procedure The E.U.T. was subjected to conducted disturbances in the frequency range 0.15-100 MHz, 10 VRMS, 1kHz, 80% AM modulation, pulse modulation 1Hz. The disturbance signal was applied to the AC power lines using a Coupling Decoupling Network (CDN) or RF Current Injection Probe for Signal Lines. The driver signal generator levels used are based on calibration that was performed in accordance with Section 6.4 and Annex A of IEC 61000-4-6: 1996, I.T.L. Procedures PM-111-CDN/M and PM-111-C.P. 105. The frequency was swept using discrete increments having a value less than 1% of the fundamental frequency. The performance of the E.U.T. was verified during the test as described in Section 7. The test setup is illustrated in the photograph Figure 38. Conducted Disturbances. 12.3 Test Results The E.U.T. passed the Conducted Disturbances immunity tests as required by specification IEC 61000-4-6: 1996. Additional details are given in Figure 31 to Figure 32. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 49 of 59

Immunity to Conducted Disturbances E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: IEC 61000-4-6: 1996 Tested at 1 khz 80% AM Modulation Using CDN Network TEST POINT PASS / FAIL ANOMALY SPECIFICATION (VRMS) THRESHOLD (kv) DC Lines Pass No anomaly 10 Figure 31. Immunity to Conducted Disturbances Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 50 of 59

Immunity to Conducted Disturbances E.U.T Description MULTI-ZONE, OUT-SMART, GUARD, OUT-LOOK, CURTAIN-FLT, CURTAIN-2PM, CURTAIN, CURTAIN-MINI, CURTAIN-SHUTTER, VIBRA-SENS, DIGITAL-KEY, RM-1 Specification: IEC 61000-4-6: 1996 Tested at Pulse Modulation 1Hz Using CDN Network TEST POINT PASS / FAIL ANOMALY SPECIFICATION (VRMS) THRESHOLD (kv) DC Lines Pass No anomaly 10 Figure 32. Immunity to Conducted Disturbances Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 51 of 59

13. Set Up Photographs Figure 33. Radiated Emission Test Figure 34. Immunity to Electrostatic Discharge Test Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 52 of 59

Figure 35. Immunity to Radiated Field Test Figure 36. Immunity to Electrical Fast Transient / Burst Test Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 53 of 59

Figure 37. Transient Waveforms Figure 38. Conducted Disturbances Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 54 of 59

14. Signatures of the E.U.T's Test Engineers Test Test Engineer Name Signature Date Radiated Emissions Y. Mordukhovitch 10.02.10 ESD Y. Mordukhovitch 10.02.10 Radiated Immunity Y. Mordukhovitch 10.02.10 EFT/B Y. Mordukhovitch 10.02.10 Conducted Disturbances Y. Mordukhovitch 10.02.10 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 55 of 59

15. APPENDIX A - CORRECTION FACTORS 15.1 Correction factors for CABLE from EMI receiver to test antenna at 3 AND 10 meter range. FREQUENCY CORRECTION FACTOR FREQUENCY CORRECTION FACTOR (MHz) (db) (MHz) (db) 30 1.96 700 11.25 35 2.08 800 12.53 40 2.26 900 13.86 45 2.43 1000 14.86 50 2.59 1200 15.7 55 2.65 1400 17.05 60 2.86 1600 18.2 65 2.96 1800 19.4 70 3.04 2000 21.3 75 3.27 80 3.41 85 3.54 90 3.68 95 3.77 100 3.93 110 4.19 120 4.41 130 4.6 140 4.83 150 5.06 160 5.35 170 5.57 180 5.7 190 5.84 200 6.02 250 6.86 300 7.59 350 8.09 400 8.7 450 9.15 500 9.53 550 9.82 600 10.24 650 10.74 NOTES: 1. The cable type is RG-214/U Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 56 of 59

15.2 Correction factors for Amplifier 8447F 30M-1.3G GAIN FREQUENCY GAIN (db) (MHz) 20 27.16 30 27.18 50 27.15 100 27.01 200 26.48 500 27.54 1000 26.96 1100 26.69 1200 26.28 1300 25.85 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 57 of 59

15.3 Correction factors for Bilog ANTENNA Model: 3142 Antenna serial number: 1250 3 meter range FREQUENCY AFE FREQUENCY AFE (MHz) (db/m) (MHz) (db/m) 30 18.4 1100 25 40 13.7 1200 24.9 50 9.9 1300 26 60 8.1 1400 26.1 70 7.4 1500 27.1 80 7.2 1600 27.2 90 7.5 1700 28.3 100 8.5 1800 28.1 120 7.8 1900 28.5 140 8.5 2000 28.9 160 10.8 180 10.4 200 10.5 250 12.7 300 14.3 400 17 500 18.6 600 19.6 700 21.1 800 21.4 900 23.5 1000 24.3 Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 58 of 59

16. APPENDIX B - MEASUREMENT UNCERTAINTY 16.1 Radiated Emission The Open Site complies with the ±4 db Normalized Site Attenuation requirements of ANSI C63.4-1992. In accordance with Paragraph 5.4.6.2 of this standard this tolerance includes instrumentation calibration errors, measurement technique errors, and errors due to site anomalies. Test Report E94310.00 MAXIMUM Security (1984) Ltd. Page 59 of 59