EMC TEST- REPORT TEST REPORT NUMBER: EFSH IE-01-E01 EUROFINS PRODUCT TESTING SERVICE (SHANGHAI) CO., LTD.

Similar documents
Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

1 SUMMARY OF STANDARDS AND RESULTS

TEST REPORT... 1 CONTENT...

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC Test report for LED Panel Light Models , , , , ,

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC TEST REPORT. According to

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

EMC VERIFICATION SUMMARY Report No.: SZHH

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

Test Report GUANGDONG EAST POWER CO., LTD

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Declaration of Conformity.

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

2620 Modular Measurement and Control System

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

PT. SARANA KARYA SOLUSINDO.

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC standards. Presented by: Karim Loukil & Kaïs Siala

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC Test Report. Report Number: M030826

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Test Report GUANGDONG EAST POWER CO., LTD

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

TEST REPORT. Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

EMC MEASUREMENT AND TEST REPORT

EMC TEST REPORT For Suzhou Omnik New Energy Co., Ltd Solar Inverter Model No. : (1) Omniksol-3K-TL (2) Omniksol-4K-TL Brand : Omnik

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC test report AU01+E04

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

Content. Report No. SH Page 2 of 22

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

CE-EMC TEST REPORT. Prepared for : Kinglumi Co., Ltd. Bldg 3, Nangang 3nd Industrial Zone, Tangtou, Shiyan Town, Bao an District, Shenzhen City, China

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

CONFORMANCE TEST REPORT FOR EN /-6

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

CE EMC TEST REPORT. Model Name: JZH-RF898B JZH-RX898B Report No.: BCTC E. Prepared for

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT. according to

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

TEST REPORT. Issued for:

CE EMC Test Report. (Declaration of Conformity) For. Electromagnetic Interference. Prepared for. Eaglerise Electronics (Foshan) Co., Ltd.

TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

EMC TEST REPORT. According to

Transcription:

EUROFINS PRODUCT TESTING SERVICE (SHANGHAI) CO., LTD. EMC TEST- REPORT TEST REPORT NUMBER: EFSH12010549-IE-01-E01 Phone: +86-21-61819181 No.395 West Jiangchang Road, Zhabei District, Shanghai, Fax: +86-21-61819180 200436, P.R. China Page 1 of 35

TABLE OF CONTENTS 1 Contents 1 Contents 2 2 General Information 3 2.1 Notes 3 2.2 Testing laboratory 4 2.3 Details of approval holder 5 2.4 Application details 5 2.5 EUT information 5 2.6 Test standards 5 3 Technical test 6 3.1 Summary of test results 6 3.2 Test environment 6 3.3 Test equipment utilized 7 3.4 Test results 8 4 Emission Test 9 4.1 Conducted Emission 9 4.2 Disturbance power 12 4.3 Radiated disturbance 14 4.4 Harmonic Current Emissions 16 4.5 Voltage Changes, Voltage Fluctuations and Flicker 19 5 Immunity Test 20 5.1 Performance Criteria Description in Clause 6 of EN 55014-2 20 5.2 Classification of apparatus 20 5.3 ESD 21 5.4 Radio frequency electromagnetic fields 22 5.5 Electrical Fast Transients 23 5.6 Surge Immunity 24 5.7 Injected currents(rf continues conducted) 25 5.8 Voltage dips and Interruption 26 5.9 Frequency magnetic field 27 6 Test setup Photos 28 7 EUT Photos 33 Page 2 of 35

2.2 Testing laboratory No.395 West Jiangchang Road, Shanghai, 200436, P.R. China Telephone : +86-21-61819181 Telefax : +86-21-61819180 CNAS ACCREDITED TESTING LABORATORY CNAS-Registration number: L4679 Test location, where different: Name : Address : No.395 West Jiangchang Road, Shanghai, 200436, P.R. China Telephone : +86-21-61819181 Fax : +86-21-61819180 Subcontractor(Radiated emission and Radiated immunity) Name : Audix Technology(Shanghai) Co., Ltd Address : 680 Gui ping RD #34.3-4F,Caohejing Hi-Tech Park,Shanghai,China Telephone :./. Fax :./. Page 4 of 35

2.3 Details of approval holder Name : Inventist Inc. Address : 4901 NW Camas Meadows Dr. Camas, WA 98607, USA Telephone :./. Fax :./. 2.4 Application details Date of receipt of application : 2012-2-14 Date of receipt of test item : 2012-2-14 Date of test : 2012-2-14 to 2012-2-22 2.5 EUT information Description of test item : Electric unicycle Type identification : SW-1 Brand Name : SOLOWHEEL Serial number :./. Power supply : 39V DC, 4.5Ah, 1000W Charger : Input:100-240V AC, 50/60Hz Output: 36V DC, 2A Test voltage : 230V~, 50Hz Additional information : The EUT is an Electric Wheel Barrow powered by Li-ion battery inside. Manufacturer: (if applicable) Name Address : Yuyao City Xinxin shunyi Plastic Mode and Electrical Appliance Factory : Point of Comtactliwang, Lishan Jiufang No.37, Lishan Country, Ditang Town, Yuyao City, China 2.6 Test standards Technical standard : EN 55014-1: 2006+A1:2009 EN 55014-2: 1997 + A1: 2001+A2: 2008 EN 61000-3-2: 2006+A1: 2009+ A2: 2009 EN 61000-3-3: 2008 Page 5 of 35

3 Technical test 3.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. or The deviations as specified were ascertained in the course of the tests performed. 3.2 Test environment Temperature : 20... 25 C Relative humidity content : 30... 60% Air pressure : 100... 103kPa Page 6 of 35

3.3 Test equipment utilized Measurement Equipment List No. Name: Type: Manufacturer: Cal due data: 1 Ultra compact simulator UCS500N7 EMTEST 2012-12-02 2 Oscilloscope TDS3012C Tektronix 2012-12-02 3 Current transformer MC2630 EMTEST 2012-12-02 4 Motorized Variac MV2616 EMTEST 2012-12-02 5 Capacitive coupling clamp HFK EMTEST 2012-12-02 6 Continuous Wave Simulator CWS500N1 EMTEST 2012-12-02 7 CDN L 801 M2/M3 Luethi 2012-12-02 8 EM Clamp EM 101 EM 101 2012-12-02 9 ESD NSG 437 TESEQ 2012-12-02 10 Triple Loop Antenna HXYZ 9170 Schwarzbeck 2012-12-02 11 EMI Test Receiver ESCI R&S 2012-12-02 12 Single phase Harmonics & California 5001ix-CTS-400 Flicker analyser Instruments 2012-12-02 13 AC Power Source 50001LX California Instruments 2012-12-02 14 Absorbing clamp MDS21 Luethi 2012-12-02 15 Artificial mains ENV216-DCV R&S 2012-12-02 16 Click meter CL55C AFJ 2012-12-02 17 LISN LS16C AFJ 2012-12-02 18 Magnetic field coil MS100 EMTEST 2012-12-02 19 Shielded Room 4*3*3 Zhong-shuo 2012-12-02 20 Shielded Room 7*4*3 Zhong-shuo 2012-12-02 21 Biconical Antenna CBL6112D Teseq 2012-05-14 22 50Ω Coaxial Switch MP59B ANRITSU 2012-03-18 23 Preamplifier 8447D Agilent 2012-03-18 24 Preamplifier 8449B HP 2012-04-26 25 Spectrum Analyzer E7405A Agilent 2012-04-26 26 Test Receiver ESVS10 R&S 2012-04-02 27 Biconical Antenna EMCO 3108 2013-01-24 28 High Gain Horn Antenna AT4002A AR 2013-01-24 29 Log-Periodic Antenna AT1080 AR 2013-01-24 30 Dual Direction Coupler DC6180 AR 2012-03-18 31 Dual Directional Coupler DC7144A AR 2012-03-18 32 Isotropic Field Monitor FM2000 AR NCR 33 Isotropic Field Probe FP2036 AR 2012-05-19 34 Power Meter 438A HP 2012-04-02 35 Power Amplifier KAW2180 AR 2012-04-02 36 State Solid Amplifier AS0825-125 MILMEGA 2012-04-02 37 Signal Generator E4421B Agilent 2012-04-02 38 Power Sensor 8481D HP 2012-04-06 Page 7 of 35

3.4 Test results 1st test test after modification production test Test case Subclause Required Test passed Test failed Conducted Emission Disturbance power Radiated disturbance Discontinuous disturbance Clause 4.1.1 of EN 55014-1 Clause 4.1.2 of EN 55014-1 Clause 4.1.2 of EN 55014-1 Clause 4.2 of EN 55014-1 Harmonic Current Emissions EN 61000-3-2 Voltage Changes, Voltage Fluctuations and Flicker Electrostatic Discharge Electrical Fast Transients Injected currents (RF continues conducted) EN 61000-3-3 Clause 5.1 of EN 55014-2 Clause 5.2 of EN 55014-2 Clause 5.3 &5.4 of EN 55014-2 Radio frequency electromagnetic fields Surge immunity Voltage dips and Interruption Clause 5.5 of EN 55014-2 Clause 5.6 of EN 55014-2 Clause 5.7 of EN 55014-2 Note 1: The Radio frequency electromagnetic fields test was not required as the appliance did not contain any clock or oscillator frequency higher than 15MHz. Note 2: The click was less than 5, and the click duration was less than 10ms. So it is deemed to comply with Discontinuous disturbance test. Page 8 of 35

4 Emission Test 4.1 Conducted Emission This clause lays down the general requirements for the measurement of disturbance voltage produced at the terminals of apparatus. 4.1.1 Limits Frequency range MHz Quasi-peak Limit At mains terminals db (µv) Average Limit 0.15 to 0.50 66 to 56 59 to 46 0.50 to 5 56 46 5 to 30 60 50 Note1: The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 30 MHz. Note2: The lower limit is applicable at the transition frequency. 4.1.2 Measurement procedure 1. The mains terminal disturbance voltage was measured with the EUT in a shielded room. 2. The EUT was connected to AC power source through a LISN (Line Impedance Stabilization Network) which provides a (50 μh + 5 Ω) 50 Ω linear impedance. The power cables of all other units of the EUT were connected to a second LISN, which was bonded to the ground reference plane in the same way as the LISN for the unit being measured. 3. The tabletop EUT was placed upon a non-metallic table 0.8m above the ground reference plane. And for floor-standing arrangement, the EUT was placed on the horizontal ground reference plane, but separated from metallic contact with the ground reference plane by 0.1m of insulation. Page 9 of 35

4. According to a pre-test at 160kHz, the voltage 230V/50Hz was selected for final test. Before get the final emission results with quasi-peak(qp) detector and average(av) detector, a pre-scan was performed with the peak(pk) detector to find out the maximum emission data plots of the EUT. 4.1.3 Measurement uncertainty Ulab(cond) = 1.8dB at 95% level of confidence, k=2 4.1.4 Results -Measurement Data Live Line: Level Page 10 of 35

Neutral Line: Level Page 11 of 35

4.2 Disturbance power This clause lays down the general requirements for the measurement of disturbance power produced at the terminals of apparatus. 4.2.1 limits Table 2a-Disturbance power limits for the frequency range 30 MHz to 300 MHz Frequency range MHz Quasi-peak Limit db (pw) Average 30 to 300 45 to 55 35 to 45 Note: Increasing linearly with the frequency from. If the limit for the measurement with the average detector is met when using a receiver with a quasi-peak detector, the equipment under test shall be deemed to meet both limits and the measurement using the receiver with an average detector need not be carried out. Table 2b-Margin when performing disturbance power measurement in the frequency range 30 MHz to 300 MHz 4.2.2 Measurement procedure Page 12 of 35

The test configuration corresponds to the standard EN 55014-1. The equipment under test is placed on a non metallic table with 0,8 m high. The lead to be measured is stretched horizontally in a straight line, to permit variation in position of the absorbing clamp along the lead to find the maximum indication. The lead shall be at least length of 6 meter. According to a pre-test at 50MHz, the voltage 230V/50Hz was selected for final test. Before get the final emission results with quasi-peak(qp) detector and average(av) detector, a pre-scan was performed with the peak(pk) detector to find out the maximum emission data plots of the EUT. The absorbing clamp is placed around the lead. 4.2.3 Measurement uncertainty Ulab(cond) = 3.35 db at confidence of 95%,k=2 4.2.4 Results Level Page 13 of 35

4.3 Radiated disturbance This clause lays down the general requirements for the measurement of Radiated disturbance produced at the space of apparatus. 4.3.1 Limits Frequency range Quasi-peak limits at 10m Quasi-peak limits at 3m MHz db (µv/m) db (µv/m) 30 to 230 30 40 230 to 1000 37 47 At transitional frequencies the lower limit applies. 4.3.2 Measurement procedure 1. The radiated emissions test was conducted in a semi-anechoic chamber. The EUT was placed upon a non-metallic table 0.8m above the ground reference plane. And for floor-standing arrangement, the EUT was placed on the horizontal ground reference plane, but separated from metallic contact with the ground reference plane by 0.1m of insulation. 2. Before get the final emission results with quasi-peak(qp) detector, a pre-scan was performed with the peak(pk) detector to find out the maximum emission data plots of the EUT. 3. The frequencies of maximum emission were determined in the final radiated emissions measurement, the physical arrangement of the test system and associated cabling was varied in order to determine the effect on the EUT's emissions in amplitude, direction and frequency. At each frequency, the EUT was rotated 360, and the antenna was raised and lowered from 1 to 4 meters in order to determine the maximum disturbance. Measurements were performed for both horizontal and vertical antenna polarization. Test was performed on subcontractor. Page 14 of 35

4.3.3 Measurement uncertainty Ulab(cond) = 3.9dB at 95% level of confidence,k=2 4.3.4 Results Horizontal: Level No Frequency Measure Level Over Limit Limit Probe Cable Amp Ant Pos Table Pos Type (MHz) (dbuv/m) (db) (dbuv/m) (db/m) (db) (db) (cm) (deg) 1 187.82 35.19-4.81 40.000 4.41 6.56 0.000 100 0 QP 2 203.63 37.28-2.72 40.000 4.30 6.50 0.000 200 320 QP Vertical: Level No Frequency Measure Level Over Limit Limit Probe Cable Amp Ant Pos Table Pos Type (MHz) (dbuv/m) (db) (dbuv/m) (db/m) (db) (db) (cm) (deg) 1 142.76 35.90-4.10 40.000 4.23 6.39 0.000 100 100 QP 2 179.80 36.88-3.12 40.000 4.32 6.47 0.000 200 150 QP 3 208.00 34.47-5.53 40.000 4.62 6.88 0.000 250 320 QP Page 15 of 35

4.4 Harmonic Current Emissions This part deals with the limitation of harmonic currents injected into the public supply system. 4.4.1 Limits Limit for Class A equipment 4.4.2 Measurement procedure The equipment under test is placed on a wooden table with a height of 0,8 m in the EMC lab. For each harmonic order, measure the 1,5 s smoothed r.m.s. harmonic current in each DFT time window and calculate the arithmetic average of the measured values from the DFT time windows, over the entire observation period. Each harmonic order, all 1.5 s smoothed r.m.s. harmonic current values and the average values for the individual harmonic currents, taken over the entire test observation period shall be less than or equal to the applicable limits. Page 16 of 35

4.4.3 Results Test Result: Pass Harmonics Source qualification: Normal Current & voltage waveforms 6 300 Current (Amps) 4 2 0-2 -4 200 100 0-100 -200 Voltage (Volts) -6-300 Harmonics and Class A limit line European Limits Current RMS(Amps) 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 4 8 12 16 20 24 28 32 36 40 Harmonic # Test result: Pass Worst harmonic was #15 with 93.97% of the limit. Page 17 of 35

Current Test Result Summary Test Result: Pass Source qualification: Normal THC(A): 0.83 I-THD(%): 186.84 POHC(A): 0.065 POHC Limit(A): 0.260 Highest parameter values during test: V_RMS (Volts): 229.96 Frequency(Hz): 50.00 I_Peak (Amps): 3.885 I_RMS (Amps): 0.950 I_Fund (Amps): 0.448 Crest Factor: 4.092 Power (Watts): 101.2 Power Factor: 0.477 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.019 1.080 1.8 0.023 1.620 1.42 Pass 3 0.426 2.300 18.5 0.427 3.450 12.36 Pass 4 0.019 0.430 4.4 0.022 0.645 3.47 Pass 5 0.397 1.140 34.8 0.397 1.710 23.22 Pass 6 0.018 0.300 6.1 0.021 0.450 4.70 Pass 7 0.355 0.770 46.1 0.357 1.155 30.89 Pass 8 0.017 0.230 7.5 0.020 0.345 5.78 Pass 9 0.305 0.400 76.4 0.308 0.600 51.29 Pass 10 0.016 0.184 8.5 0.018 0.276 6.66 Pass 11 0.251 0.330 75.9 0.254 0.495 51.26 Pass 12 0.014 0.153 9.0 0.017 0.230 7.19 Pass 13 0.195 0.210 92.7 0.198 0.315 62.97 Pass 14 0.012 0.131 9.1 0.014 0.197 7.25 Pass 15 0.141 0.150 94.0 0.145 0.225 64.45 Pass 16 0.010 0.115 8.6 0.012 0.173 6.86 Pass 17 0.093 0.132 70.5 0.097 0.199 48.80 Pass 18 0.008 0.102 7.9 0.009 0.153 6.19 Pass 19 0.054 0.118 45.4 0.057 0.178 32.19 Pass 20 0.006 0.092 7.1 0.008 0.138 5.47 Pass 21 0.027 0.107 25.1 0.029 0.161 17.92 Pass 22 0.005 0.084 6.4 0.006 0.125 4.93 Pass 23 0.020 0.098 20.7 0.023 0.147 15.73 Pass 24 0.004 0.077 0.0 0.005 0.115 4.54 Pass 25 0.026 0.090 29.0 0.029 0.135 21.70 Pass 26 0.004 0.071 0.0 0.005 0.106 4.43 Pass 27 0.029 0.083 35.3 0.031 0.125 24.61 Pass 28 0.004 0.066 0.0 0.004 0.099 4.53 Pass 29 0.028 0.078 35.8 0.028 0.116 24.15 Pass 30 0.003 0.061 0.0 0.004 0.092 4.34 Pass 31 0.022 0.073 30.7 0.023 0.109 21.18 Pass 32 0.003 0.058 0.0 0.003 0.086 3.98 Pass 33 0.015 0.068 21.7 0.016 0.102 15.59 Pass 34 0.002 0.054 0.0 0.003 0.081 3.44 Pass 35 0.007 0.064 10.8 0.008 0.096 8.43 Pass 36 0.002 0.051 0.0 0.002 0.077 3.06 Pass 37 0.002 0.061 0.0 0.004 0.091 4.44 Pass 38 0.002 0.048 0.0 0.002 0.073 2.95 Pass 39 0.006 0.058 11.5 0.008 0.087 9.35 Pass 40 0.002 0.046 0.0 0.002 0.069 3.04 Pass Page 18 of 35

4.5 Voltage Changes, Voltage Fluctuations and Flicker This part is concerned with the limitation of voltage fluctuations and flicker impressed on the public lowvoltage system. 4.5.1 Limits Value Limit Pst 1,0 Plt 0,65 dt 3,3% dc 3,3% dmax 4,0% 4.5.2 Measurementest procedure The equipment under test is placed on a wooden table with a height of 0,8 m in the EMC lab. The voltage fluctuations and flicker were measured at the supply terminals of the EUT. 4.5.3 Results Parameter values recorded during the test: Vrms at the end of test (Volt): 229.91 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.028 Test limit: 0.650 Pass Page 19 of 35

5 Immunity Test 5.1 Performance Criteria Description in Clause 6 of EN 55014-2 Criterion A: Criterion B: Criterion C: The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. During the test, degradation of performance is allowed, however. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation and from what the user may reasonably expect from the apparatus if used as intended. Temporary loss of function is allowed, provided the function is self recoverable or can be restored by the operation of the controls, or by any operation specified in the instructions for use. 5.2 Classification of apparatus Category I: Apparatus containing no electronic control circuitry. Category II: Transformer toys, dual supply toys, mains powered motor operated appliances, tools, heating appliances and similar electric apparatus (for example. UV radiators, IR radiators and microwave ovens) containing electronic control circuitry with no internal clock frequency or oscillator frequency higher than 15 MHz. Category III: Category IV: Battery powered apparatus (with built-in batteries or external batteries), which in normal use is not connected to the mains, containing an electronic control circuitry with no internal clock frequency or oscillator frequency higher than 15 MHz. All other apparatus covered by the scope of this standard. The EUT belongs to Category II. Page 20 of 35

5.3 ESD 5.3.1 Test Procedures 1. Contact discharge was applied only to conductive surfaces of the EUT. Air discharge was applied only to non-conducted surfaces of the EUT. 2. The EUT was put on a 0.8m high wooden table for table-top equipment or 0.1m high for floor standing equipment standing on the ground reference plane (GRP). 3. A horizontal coupling plane(hcp) 1.6m by 0.8m in size was placed on the table, and the EUT with its cables were isolated from the HCP by an insulating support thick than 0.5mm. The VCP 0.5m by 0.5m in size while HCP were constructed from the same material type and thickness as that of the GRP, and connected to the GRP via a 470kΩ resistor at each end. The distance between EUT and any of the other metallic surfaces excepted the GRP, HCP and VCP was greater than 1m. 4. During the contact discharges, the tip of the discharge electrode was touching the EUT before the discharge switch is operated. During the air discharges, the round discharge tip of the discharge electrode was approached as fast as possible to touch the EUT. After each discharge, the ESD generator was removed from the EUT, the generator is then retriggered for a new single discharge. For ungrounded product, a discharge cable with two resistances was used after each discharge to remove remnant electrostatic voltage. 10 times of each polarity single discharge were applied to HCP and VCP. 5.3.2 Results Table (T) Contact (C) Voltage Number of Polarity Test point Opinion Floor (F) Air (A) (kv) discharge (+ / -) Air contact T A 8 20 + / - A Direct contact T C 4 20 + / - A HCP T C 4 20 + / - A VCP T C 4 20 + / - A A: no loss of function. Page 21 of 35

5.4 Radio frequency electromagnetic fields 5.4.1 Measurement procedure 1. The EUT was placed on 0.8m high wooden table for table-top equipment. For floor standing equipment, the EUT was placed on a 0.1m high wooden support above the GRP.The tests normally shall be performed with the generating antenna facing each of four sides of the EUT. When equipment can be used in different orientations (e.g. vertical or horizontal) the test shall be performed on all possible sides of the EUT. 2. The tests are carried out with a field strength by 3 V/m (measured in the unmodulated field) with amplitude modulated signal by a depth of 80 % by a sinusoidal audio signal of 1 khz. The logarithmic step was 1% and the dwell time was 3s dependent of the EUT cycle time. Test was performed on subcontractor. 5.4.2 Results Frequency Range Voltage(RMS) Modulation Frequency Opinion 80M-1GHz 3V/m 1kHz,80%,AM A A: no loss of function. Page 22 of 35

5.5 Electrical Fast Transients 5.5.1 Measurement procedure 1. The EUT was placed on a ground reference plane(grp) insulated by an insulating support 0,1 m thick and the GRP was placed on a 0.8m high wooden table for table-top equipment. For floor standing equipment, the EUT was placed on a 0.1m high wooden support above the GRP. 2. The GRP shall project beyond the EUT and the clamp by at least 0.1m on all sides. The distance between the EUT and any other of the metallic surface except the GRP was greater than 0.5m. All cables to the EUT was placed on the insulation support 0.1m above GRP. Cables not subject to EFT was routed as far as possible from cable under test to minimize the coupling between the cables. 3. The length of signal and power cable between the EUT and EFT generator was 0.5m. If the cable is a non-detachable supply cable more than 0.5m, the excess length of this cable shall be folded to avoid a flat coil and situated at a distance of 0.1m above the GRP. 5.5.2 Results Test port Voltage (kv) Polarity (+ / -) Duration (s or min) Waveform Tr / Th Repetition Frequency (khz) Opinion AC power line 1 + 2 min 5/50 ns 5 A AC power line 1-2 min 5/50 ns 5 A A: no loss of function. Page 23 of 35

5.6 Surge Immunity 5.6.1 Measurement procedure 1. The EUT was placed on a ground reference plane(grp) insulated by an insulating support 0,1 m thick and the GRP was placed on a 0.8m high wooden table for table-top equipment. For floor standing equipment, the EUT was placed on a 0.1m high wooden support above the GRP. 2. The 1,2/50 µs surge was to be applied to the EUT power supply terminals via the capacitive coupling network.decoupling networks were required in order to avoid possible adverse effects on equipment not under test that may be powered by the same lines and to provide sufficient decoupling impedance to the surge wave so that the specified wave may be applied on the lines under test. 3. The positive pulses are applied 90 relative to the phase angle of the a.c. line voltage to the equipment under test, and the negative pulses are applied 270 relative to the phase angle of the a.c. line voltage to the equipment under test. 5.6.2 Results Test mode Polarity (+ / -) Voltage ( kv ) Waveform Tr / Th Number of pulses Opinion Live-Neutral + 0.5/1.0 1.2/50 µs 5 A Live-Neutral - 0.5/1.0 1.2/50 µs 5 A A: no loss of function. Page 24 of 35

5.7 Injected currents(rf continues conducted) 5.7.1 Measurement procedure 1. The EUT was placed on an insulating support of 0.1m height above a ground reference Plane, arranged and connected to satisfy its functional requirement. All cables exiting the EUT was supported at a height of at least 30 mm above the ground reference plane. 2. The coupling and decoupling devices were required, they were located between 0,1 m and 0,3 m from the EUT. This distance was to be measured horizontally from the projection of the EUT on to the ground reference plane to the coupling and decoupling device. 3. The frequency range was swept from 150 khz to 230 MHz, using the signal levels established during the setting process, and with the disturbance signal 80 % amplitude modulated with a 1 khz sine wave, pausing to adjust the RF signal level or to change coupling devices as necessary. Where the frequency was swept incrementally, the step size do not exceed 1 % of the preceding frequency value. The dwell time of the amplitude modulated carrier at each frequency was not less than the time necessary for the EUT to be exercised and to respond, and was not less than 3s. 5.7.2 Results Test port Voltage (rms) Modulation Frequency Frequency Range Opinion AC power line 3 1 khz, 80%,AM 150 khz - 230 MHz A A: no loss of function. Page 25 of 35

5.8 Voltage dips and Interruption 5.8.1 Measurement procedure Phase switch 1 Power supply switch 2 EUT Voltage meter Oscilloscope Neutral 1. The EUT was placed on a ground reference plane(grp) insulated by an insulating support 0,1 m thick and the GRP was placed on a 0.8m high wooden table for table-top equipment. For floor standing equipment, the EUT was placed on a 0.1m high wooden support above the GRP. 2. The test was performed with the EUT connected to the test generator with the shortest power supply cable as specified by the EUT manufacturer. Voltage change shall occur at zero crossing. 3. The EUT was tested for each selected combination of test level and duration with a sequence of three dips /interruptions with intervals of 10 s minimum. Each representative mode of operation was tested. 5.8.2 Results Reduction of supply voltage of Voltage in % (in V) Duration in parts of period (in ms) Opinion interruption 0 % (0V) 0,5 (10 ms) A 60 % 40 % (92 V) 10 (200 ms) B 30 % 70 % (161 V) 25 (500 ms) B A: no loss of function. B: the appliance could not work normal during voltage dips, but after test it would recover. Page 26 of 35

5.9 Frequency magnetic field The magnetic fields to which equipment is subjected may influence the reliable operation of equipment and systems. 5.9.1 Measurement procedure The electromagnetic conditions of the laboratory shall be such as to guarantee the correct operation of the EUT in order not to influence the test results; otherwise, the tests shall be carried out in a Faraday cage. The plane of the inductive coil shall then be rotated by 90 in order to expose the EUT to the test field with different orientations. 5.9.2 Results Test Frequency Field Level (A/m) Duration (Second) Axis of Orientation Opinion 50/60Hz 3 120 X A 50/60Hz 3 120 Y A 50/60Hz 3 120 Z A A: No degradation of function. Page 27 of 35

6 Test setup Photos Conducted Emission test setup Disturbance power test setup Page 28 of 35

Radiated disturbance test setup Harmonic Current Emissions/ Voltage Changes, Voltage Fluctuations and Flicker test setup Page 29 of 35

Electrostatic Discharge test setup Electrical Fast Transients/ Surge immunity/ Voltage dips and Interruption test setup Page 30 of 35

Injected currents (RF continues conducted) test setup Radio frequency electromagnetic fields test setup Page 31 of 35

Frequency magnetic field test setup Page 32 of 35

7 EUT Photos Overall view Side view Page 33 of 35

Internal view PCB view Page 34 of 35

Charger Page 35 of 35