Sampling Efficiency in Digital Camera Performance Standards

Similar documents
Edge-Raggedness Evaluation Using Slanted-Edge Analysis

Camera Resolution and Distortion: Advanced Edge Fitting

A Study of Slanted-Edge MTF Stability and Repeatability

Measurement of Texture Loss for JPEG 2000 Compression Peter D. Burns and Don Williams* Burns Digital Imaging and *Image Science Associates

Defense Technical Information Center Compilation Part Notice

Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing

Diagnostics for Digital Capture using MTF

ISO INTERNATIONAL STANDARD. Photography Electronic still-picture cameras Resolution measurements

Modified slanted-edge method and multidirectional modulation transfer function estimation

Fast MTF measurement of CMOS imagers using ISO slantededge methodology

Migration from Contrast Transfer Function to ISO Spatial Frequency Response

Intrinsic Camera Resolution Measurement Peter D. Burns a and Judit Martinez Bauza b a Burns Digital Imaging LLC, b Qualcomm Technologies Inc.

Practical Scanner Tests Based on OECF and SFR Measurements

An Evaluation of MTF Determination Methods for 35mm Film Scanners

Module 3: Video Sampling Lecture 18: Filtering operations in Camera and display devices. The Lecture Contains: Effect of Temporal Aperture:

Determination of the MTF of JPEG Compression Using the ISO Spatial Frequency Response Plug-in.

DIGITAL IMAGING. Handbook of. Wiley VOL 1: IMAGE CAPTURE AND STORAGE. Editor-in- Chief

Influence of Image Enhancement Processing on SFR of Digital Cameras

Measuring MTF with wedges: pitfalls and best practices

Reducing Proximity Effects in Optical Lithography

Resolution test with line patterns

Copyright 1997 by the Society of Photo-Optical Instrumentation Engineers.

Parameters of Image Quality

On spatial resolution

For more information about how to cite these materials visit

Secrets of Telescope Resolution

Received 14 October 2016; revised 30 December 2016; accepted 16 January 2017; posted 17 January 2017 (Doc. ID ); published 9 February 2017

MTF Analysis and its Measurements for Digital Still Camera

A Simple Method for the Measurement of Modulation Transfer Functions of Displays

Resolution. [from the New Merriam-Webster Dictionary, 1989 ed.]:

Digital Imaging Performance Report for Indus International, Inc. October 27, by Don Williams Image Science Associates.

INTRODUCTION TO MODERN DIGITAL HOLOGRAPHY

Evaluating Commercial Scanners for Astronomical Images. The underlying technology of the scanners: Pixel sizes:

Defocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique

A Novel Method for Enhancing Satellite & Land Survey Images Using Color Filter Array Interpolation Technique (CFA)

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Instructions for Use of Resolution Chart

Measurement and protocol for evaluating video and still stabilization systems

Debunking of Specsmanship:

PIAS -II. Print Quality Measurements anytime, anywhere objective, reliable, easy. Innovative measurement instruments from

QUANTITATIVE IMAGE TREATMENT FOR PDI-TYPE QUALIFICATION OF VT INSPECTIONS

High Resolution Imaging for Inspection of Laser Beam Melting Systems

1. Redistributions of documents, or parts of documents, must retain the SWGIT cover page containing the disclaimer.

Scanner and Camera Imaging Performance: Benchmarking and Workflow Monitoring Don Williams, Image Science Associates and Peter D.

Optical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation

MULTIPLE SENSORS LENSLETS FOR SECURE DOCUMENT SCANNERS

DISPLAY metrology measurement

A comparison between medical-grade liquid crystal display (LCD) and ipad color imaging

Investigation of Effective DQE (edqe) parameters for a flat panel detector

What is a "Good Image"?

digital film technology Resolution Matters what's in a pattern white paper standing the test of time

The Necessary Resolution to Zoom and Crop Hardcopy Images

Iso pdf. Iso pdf.zip

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Improved Fusing Infrared and Electro-Optic Signals for. High Resolution Night Images

SUPER RESOLUTION INTRODUCTION

Tech Paper. Anti-Sparkle Film Distinctness of Image Characterization

Digital Detector Array Image Quality for Various GOS Scintillators

Dental photography: Dentist Blog. This is what matters when choosing the right camera equipment! Checklist. blog.ivoclarvivadent.

ABOUT RESOLUTION. pco.knowledge base

Paper or poster submitted for Europto-SPIE / AFPAEC May Zurich, CH. Version 9-Apr-98 Printed on 05/15/98 3:49 PM

Visibility of Uncorrelated Image Noise

IEEE P1858 CPIQ Overview

Angle of View & Image Resolution

Sharpness, Resolution and Interpolation

Image Evaluation and Analysis of Ink Jet Printing System (I) MTF Measurement and Analysis of Ink Jet Images

Objective View The McGraw-Hill Companies, Inc. All Rights Reserved.

Large Field of View, High Spatial Resolution, Surface Measurements

Congress Best Paper Award

Dealiased spectral images from aliased Fizeau Fourier transform spectroscopy measurements

LCD handheld displays characterization by means of the MTF measurement

Practical Image and Video Processing Using MATLAB

Fundamental and Clinical Studies for Effectiveness of Zero-filling Interpolation on k-space for Improvement of Sharpness in Magnetic Resonance Imaging

Image Processing for feature extraction

4K Resolution, Demystified!

TIPA Camera Test. How we test a camera for TIPA

Preservation Microfilm Scanner Target and Imaging Performance Software (Mscan) User Guide Version May 2010

University of Westminster Eprints

This document is a preview generated by EVS

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

How to Read MTF Curves

Dynamically Reparameterized Light Fields & Fourier Slice Photography. Oliver Barth, 2009 Max Planck Institute Saarbrücken

Optical System Image Irradiance Simulations

Optical design of a high resolution vision lens

Distance Estimation with a Two or Three Aperture SLR Digital Camera

Optical System Case Studies for Speckle Imaging

Simultaneous Capturing of RGB and Additional Band Images Using Hybrid Color Filter Array

Introduction to Video Forgery Detection: Part I

Improving Signal- to- noise Ratio in Remotely Sensed Imagery Using an Invertible Blur Technique

Copyright 2000 by the Society of Photo-Optical Instrumentation Engineers.

Midterm Examination CS 534: Computational Photography

PROCEEDINGS OF SPIE. Front converter lenses for smart phones

Optical Correlator for Image Motion Compensation in the Focal Plane of a Satellite Camera

Relationships between lens performance and different sensor sizes in professional photographic still SLR cameras

CCD Requirements for Digital Photography

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

On-orbit spatial resolution estimation of IRS: CARTOSAT-1 Cameras with images of artificial and man-made targets Preliminary Results

Digital Photography Standards

Focus-Aid Signal for Super Hi-Vision Cameras

Transcription:

Copyright 2008 SPIE and IS&T. This paper was published in Proc. SPIE Vol. 6808, (2008). It is being made available as an electronic reprint with permission of SPIE and IS&T. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purpose, or modification of the content of this paper are prohibited. Sampling Efficiency in Digital Camera Performance Standards Peter D. Burns a and Don Williams b a Carestream Health, Inc., Rochester, NY USA b Image Science Associates, Williamson, NY USA ABSTRACT One of the first ISO digital camera standards to address image microstructure was ISO 12233, which introduced the SFR, spatial frequency response, based on the analysis of edge features in digital images. The SFR, whether derived from edges or periodic signals, describes the capture of image detail as a function of spatial frequency. Often during camera testing, however, there is an interest in distilling SFR results down to a single value that can be compared with acceptable tolerances. As a measure of limiting resolution, it has been suggested that the frequency at which the SFR falls to, e.g., 10%, can be used. We use this limiting resolution to introduce a sampling efficiency measure, being considered under the current ISO 12233 standard revision effort. The measure is the ratio of limiting resolution frequency to that implied by the image (sensor) sampling alone. The rationale and details of this measure are described, as are example measurements. One-dimensional sampling efficiency calculations for multiple directions are included in a two-dimensional analysis. Keywords: camera resolution, SFR, MTF, limiting resolution, sampling efficiency, effective megapixel 1. INTRODUCTION Along with the development and adoption of standard methods for evaluating digital camera imaging performance has come the need for a simple interpretation of the results. ISO 12233 was one of the first to address digital camera performance. It introduced the spatial frequency response (SFR), based on analysis of an edge feature in the digital image. The SFR, whether derived from edge analysis or periodic signals, describes the capture of image detail as a function of spatial frequency. Often during camera testing, however, there is an interest in distilling SFR results down to a single value that can be compared with acceptable tolerances. A measure of limiting resolution is often sought, and it has been suggested that the frequency at which the SFR falls to, e.g., 10%, can serve this purpose. The use of limiting resolution is well established and is usually measured by visual examination of periodic image features such as high contrast lines. The method currently being considered in the ISO 12233 standard revision effort, however, is an extension of the methods established in the current digital camera resolution standard. A limiting resolution value is one measure of the ability of an image capture system to record image detail information. This measure is acknowledged as providing an incomplete description of image sharpness or image quality. It is, nevertheless, natural to compare the limiting image resolution with that implied by the sampling resolution. The sampling resolution, sometimes referred to as the addressable resolution or sampling rate, is based on the digital image sampling. It is the comparison of the measured limiting resolution with the sampling resolution that can be expressed as a sampling efficiency. Before proceeding with the development of the proposed sampling efficiency measure, it is useful to discuss several terms that we will be using. The visual impression of spatial detail in a displayed image is often described by its apparent sharpness for pictorial scene content. The term resolution can also used to indicate the visual impression of imagespatial detail. ISO 12233, however, defines resolution as, a measure of the ability of a digital image capture system, or a 1 component of a digital image capture system, to distinguish picture detail. We will follow this usage with the observation that the standard then proceeds to define the particular measure of resolution as the spatial frequency response. Limiting resolution, also called the minimum resolvable distance, is the minimum separation distance between two objects (often lines) so that they can be seen as distinct. Given that we are concerned with measurements based on image data, we will use the term limiting resolution to mean an indirect measure (or estimate) of this distance, expressed as a peter.burns@carestreamhealth.com

corresponding spatial frequency. In this paper, since any measure of limiting resolution will be based on automated analysis, we can interpret it as a surrogate for the value that might be derived from a visual evaluation of that image, if it were displayed. Sampling resolution is that implied by the sampling (or size) of the delivered image file. When expressed in terms of pixels, the sampling interval is one pixel. The corresponding spatial frequency is the halfsampling, or Nyquist, frequency of 0.5 cycles/pixel. 1.1 Camera Resolution ISO 12233 The ISO method, 1, 2 based on the analysis of slanted-edge image features, is a special case of edge-gradient analysis. The analysis is performed on a digital image containing a high-quality edge feature. From this edge, one needs to estimate an edge-spread function for the image transition (edge profile). From this edge profile, a sampled line-spread function is found by estimating the first derivative. The modulus of the computed discrete Fourier transform of this line-spread function, after scaling, is the measured, normalized signal-modulation function of spatial frequency. This is the measured spatial frequency response (SFR) called for in the standard. In cases where the objective is to characterize the performance limited by lens, sensor and readout electronics, it is often recommended that some camera features, such as spatial image processing, be disabled during testing. Often this is not easy, but also has the disadvantage that device-testing conditions will then differ from normal usage. Here, we will assume that a system test is to be undertaken, which includes all normal digital camera settings. As we will see, this can influence the measured SFR, when digital image sharpening (or blurring) is present. Figure 1 shows the measured SFR for a digital camera set at two lens positions. One test image was acquired with the camera focused on the test target and the other with the lens set to be out of focus. The spatial frequency axis is shown in terms of cycles/pixel rather than cycles/mm on a test target. The value of 0.5 cy/pixel is the half-sampling frequency and is often taken as the upper limit for unambiguous capture of scene spatial information. We are not addressing artifacts such aliasing that result from image sampling in this paper, so we will simply take 0.5 cy/pixel as the upper frequency of interest. Note that the rise in SFR near 0.1 cy/pixel for the focused image indicates that digital image sharpening has been applied. This is also applied in the second image path, but the effect is reduced by the optical defocus. Figure 1. SFR measurement results for a digital camera with two lens focus positions. An additional method for digital camera SFR evaluation that is likely to be included in the second edition of the ISO 12233 standard is based on polar sinewave image features (Siemens star). 3 Either the edge (E-SFR) or sinewave SFR (S- SFR)could serve as the basis for the limiting resolution and sampling efficiency. For completeness we note that a third, non-sfr based, approach is being considered for inclusion in the revised standard. This visual resolution metric 4 is adopted from a Camera and Imaging Products Association (CIPA) standard, and is correlated with the edge-based 10% SFR measure described in this paper. The reader is referred Ref. 5 in these proceedings for more information.

2. LIMITING RESOLUTION BASED ON SFR The rationale for deriving a measure of limiting resolution from the SFR comes from the optics community. For continuous optical systems, the frequency associated with the 10% MTF response point can generally be interpreted as a summary resolution value consistent with the Rayleigh criterion. 6 If we interpret a measured SFR data set as an estimate of the digital camera s effective (sample) MTF, then it is natural to apply a similar rule. While the idea is simple to express, two points of caution are worth noting. The empirical Rayleigh criterion was derived for visual instruments such as telescopes. The viewing of digital images of continuous scene information may approximate this condition but not if significant artifacts such as aliasing or contouring are present. In addition, image noise introduced during image capture is not accounted for when using this approach. While it is possible to measure a 10% SFR frequency for various cameras, the correspondence of these values to visual limiting resolution data may vary with image noise level. Figure 2 outlines the steps in the procedure. We start with a digital image test file containing the edge feature used in the SFR evaluation. In addition, the critical value of 0.1 is used. Given that the measured SFR is a vector representing the sampled function, it is likely that the frequency where the SFR falls to 0.1 can be interpolated from nearby data. The results of this analysis for a near-horizontal edge from a digital camera image are shown in Fig. 3. In this case, the limiting resolution was found to be 0.44 cy/pixel. If we compare this with sampling resolution as defined by the halfsampling frequency, 0.5 cy/pixel, then the one-dimensional vertical sampling efficiency is, limiting res 0.44cy / pixel E v = = = 88% (1) sampling res 0.5cy / pixel Note that we can calculate sampling efficiency values for the two SFR results shown in Fig. 1. The 10% limiting resolution values are 0.38 and 0.33 for the focused and defocused cases, respectively. The corresponding sampling efficiency values are 0.76 and 0.66, respectively. test file, critical value, α Evaluate SFR f i, SFR i Find critical frequency Interpolate SFR f α f p,where SFR p α ' wheresfr = α Figure 2. Calculation of limiting resolution (frequency) from SFR. Figure 3. Results of 10% SFR calculation as in Fig. 2.

3. TWO-DIMENSIONAL SAMPLING EFFICIENCY Although the above one-dimensional sampling efficiency value may be useful, it fails to account for differences in performance that often occur as a function of angular direction across a digital image. This calls for some form of twodimensional sampling efficiency, which would also facilitate comparison with a camera s total image pixels ( megapixel value). The proposed two-dimensional sampling efficiency measure under consideration for ISO 12233 revision calls for the following steps: 1. SFR measurement in three principal directions: vertical, horizontal, and diagonal. 2. Estimation of limiting resolution frequency and sampling efficiency in each direction: E v, Eh, Ed. Note that the diagonal sampling efficiency calculation uses the same sampling resolution frequency, 0.5 cy/pixel, as for the horizontal and vertical directions, rather than the extended range of frequency support, [0-0.707 cy/pixel] of the sampled signal spectrum. 3. Calculation of the sampling resolution rating Es as the product of Ev and the average of Ev and Eh : ( E + E ) 100E Es = d v h % (2) 2 A rotationally symmetrical SFR surface is shown in Fig. 4, with its 0.1 and 0.5 value contours. In this case, the 10% limiting resolution frequency is 0.5 cy/pixel for the vertical, horizontal, and diagonal directions. So by Eq. 2, the twodimensional sampling efficiency is 100%. Figure 4. Example of two-dimensional symmetric SFR and corresponding 50% and 10% response contours. For some digital systems, the acquisition SFR or MTF can be assumed to be separable so that, M h ( ) () MTF ( u, v) M ( u) M ( v) = h v (3) where u and M v v are the one-dimensional horizontal and vertical MTFs, respectively, and u and v are the corresponding spatial frequency coordinates. In this case, the diagonal sampling efficiency is computed from the array ( u) SFR ( u) SFR (u) SFRd = h v. (4)

CONCLUSIONS A sampling efficiency measure is introduced as an extension of the current ISO 12233 standard revision effort. The measure is based on the ratio of a 10% SFR-spatial frequency bandwidth to the bandwidth implied by the image sampling alone, for a digital camera under test. While this measure is not intended to include the influence of sampling artifacts and image noise, it can provide guidance when considering the level of image signal detail likely to be delivered by a camera. In addition, it can be used to select between camera operating conditions, e.g., file size selection for an imaging task. The measured sampling efficiency provides a convenient factor for the adjustment of advertised values to yield an effective megapixel value. ACKNOWLEDGMENTS It is a pleasure to acknowledge the helpful comments and suggestions from the members of the ISO 12233 standards revision committee. REFERENCES 1 2 3 4 5 6 ISO 12233, Photography Electronic still picture cameras Resolution measurements, ISO, 1998. P. D. Burns and D. Williams, Refined Slanted-Edge Measurement for Practical Camera and Scanner Testing, Proc. PICS Conf., IS&T, 191-195, (2002). D. Wueller, Proposal for a Standard Procedure to Test Mobile Phone Cameras, Proc. SPIE-IS&T Electronic Imaging Symp., SPIE vol. 6069, 229-241, (2006). CIPA DC-003-Translation-2003 Resolution Measurement Methods fro Digital Cameras, CIPA, Tokyo, available via Internet at, http://www.cipa.jp/english/hyoujunka/kikaku/pdf/dc-003_e.pdf D. Williams, D. Wüller, H. Yoshida, K. Matherson, P. Hubel, A Pilot Study of Digital Camera Resolution Metrology Protocols Proposed Under ISO 12233 Edition 2, Proc. SPIE-IS&T Electronic Imaging Symp., SPIE vol. 6808, (2007) in press. M. Born and E. Wolf, Principles of Optics, 6th ed., Pergamon Press, Oxford, 1980, pg. 333-335.