WIRE-PRESS SOCKETS (AXW)

Similar documents
CF Series AXC5/AXC6. FEATURES 1. Vertical mating type with a 0.8 mm mated height low profile design

For board-to-fpc. Narrow pitch connectors (0.4mm pitch)

For FPC. FPC connectors (0.3mm pitch) Back lock

FPC connectors (0.3mm pitch) Front lock with FPC tabs

For FPC. FPC connectors (0.2mm pitch) Back lock

For FPC. FPC connectors (0.3mm pitch) Back lock

FPC CONNECTORS Y3FT (0.3 mm pitch) with FPC tabs

For board-to-fpc. Narrow pitch connectors (0.4mm pitch)

2.5mm Pitch Connectors for Full Lock and Discrete Wire Connection

2mm Pitch Connector for Discrete Wire Connection(Product approved by UL CSA Standard)

Modular Plug Connectors compliant to Cat.6 A Standard

15A 3.96mm pitch Wire-to-Board Connectors for Internal Power Supply

5mm Pitch Miniature Potting Connectors for Secondary Power Supply


2.54mm Pitch Board to Board Connector

Small-sized, plastic type, push-pull lock connectors

2.54mm Pitch Board to Board Connector

D-Sub Connectors XM3. D-Sub Connectors That Are Ideal for Office Equipment Interfaces. Space-saving 9-pin Slim D-sub Socket Connectors for Boards

UP TO 8GHz SMALL MICROWAVE RELAYS

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

2.5mm Pitch Connector for Discrete Wire Connection

Palm-sized, 16-channel Relay Terminals

2.5mm Pitch Connector for Discrete Wire Connection

Powerpole Connectors - PP75: up to 120 Amps

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

Miniature Waterproof Shielded Connectors

Powerpole Connectors - PP75: up to 120 Amps

Miniature Waterproof Shielded Connectors

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

Powerpole Connectors - PP75: up to 120 Amps

Setting Standards Connectors M 16

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage


PORTE-CLIPS 12 VOIES MQS GENE II MQS MARK II 12-POSITION RECEPTACLE HOUSING. Traduit par le Service Technique le 16 septembre 2002

M22 Connectors Specification

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

MINIATURE RELAY FOR WIDER APPLICATIONS

M20 Connectors Specification

SB 50 Connectors - up to 120 amps

1.7mm pitch, Low Profile Wire-to-Board Connectors for Power Supplies

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

Transistor drive 2c/4c 5A slim power relays

JULY 2014 SECTION TITLE PAGE. 1 Description of Connectors and Intended Applications 2. 2 Marking of Connector and/or Package 2.

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

RT-3 UNIT RELAY 4-POINT TERMINAL

Slim compact safety relay

1.7 mm pitch, Low Profile Board to Wire Connectors for Power Supplies

2mm Pitch Connector for Discrete Wire Connection(Product approved by UL CSA Standard)

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

RT-3 UNIT RELAY 4-POINT TERMINAL

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

SBS Connectors - up to 110 amps

SECTION TITLE PAGE. 1 Description of Connectors and Intended Applications 2. 2 Marking of Connector and/or Package 2. 3 Ratings 3

1a 8A, 1a1b/2a 5A small polarized power relays

New pin layout (LT type) added. Best seller with broad lineup and AC 2000 V breakdown voltage.

CAT 6 Data Wiring System Connectors

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

SLIM COMPACT SAFETY RELAY

2mm Pitch Connector for Discrete Wire Connection(Product approved by UL CSA Standard)

AVX Wire-to-Board Connectors

COMPONENT SPECIFICATION M20 SERIES CONNECTORS AUGUST 2016 CONTENTS: SECTION TITLE PAGE. 1 Description of Connector and Intended Application 2

2 2.2 mm Pitch, Wire-to-Wire Connectors for Small Spaces

High Speed, Matched-Impedance, Parallel Board-to-board Connector System

Modular Plug Connectors Compliant to Enhanced Category 5 Standards

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

High Sensitivity, with 100mW nominal operating power, in a compact and space saving case

INSULATION DISPLACEMENT IDC. PITCH d : 1.27X1.27mm, b : 2.00X2.00mm, a : 2.54X2.54mm IDCR IDC RIBBON CONNECTOR IDB IDC D-SUB CONNECTOR

.100" RECEPTACLE STRIPS SINGLE AND DUAL ROW.100" [2.54] CENTERLINE RS SERIES

Gecko Connectors Introduction

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

1.25mm Pitch Miniature Crimping Connector (UL Listed)

Stac64 Unsealed Connector System

2.5mm Pitch Connector for Discrete Wire Connection (Product Compliant with UL/CSA Standard)

High Power/Signal Connectors for Industrial Machinery

1.7mm pitch, Low Profile Wire-to-Board Connectors for Power Supplies

1a 8A, 1a1b/2a 5A small polarized power relays

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

sealed mini usb connectors

FBX1104P FBX1104 FBX1106P FBX1106

CAT 6 Data Wiring System Connectors

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, FLANGE MOUNTING, MINIATURE, CLASSES E, F, G AND R

HEADER & HOUSING SYSTEMS

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

PC BOARD MOUNTING CONNECTORS

15 Industrial Tools. Recognized by Professionals. Work Together. Scribing Needle. Replacement of Scribing Needle. Features. Use A B

0.5mm Pitch Connectors with Ground Plate for 2mm to 3mm High-Speed Board-to-Board Connections

COMPACT PC BOARD POWER RELAY

Cable & Bolt Cutters. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Remote Input/Output Terminal System (RITS) Connectors

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

MX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM

SBS Connectors - up to 110 amps

Transcription:

FOR PC BORD TO WIRE XW WIRE-PRESS SOCKETS (XW) FETURES 1. Pressure welding method for superior wiring and no need to strip wires. pplicable wires: WG #22, #24, #26, #28. 2. Two pressure weldings assure high contact reliability. Labor saving one-touch attachment of the cover and body Strain relief clamp Socket Polarity guide (prevents incorrect insertion) Vertical hood cover type With hood cover With semi-cover Socket Compliance with RoHS Directive The two pressure weldings on the cable assure high reliability. The depth of the contact portion provides stable contact. Holds the cable insulation to protect the pressure welding. Pressure welding contact 3. Labor saving one-touch attachment of the cover and socket body. 4. Even if the number of wires is samll, the stable pressure welding is acquired. djacent mounting is possible to save space. Strain relief band ngled hood cover type 6. Fits MIL headers and low profile headers (box and open types). 7. Useful pressure welding tools are available. If the number of wires is small or if the insulation is thin, the strain relief clamp can be reversed to hold the wires. 5. ngled hood cover type can save space and makes adjacent mounting possible. PPLICTIONS NC machine, automated equipment, office automation equipment, ME equipment, measurement equipment, communications equipment, amusement and game equipment. ORDERING INFORMTION 1. Socket 1: Wire-press sockets (Socket) < (2 digits)> XW <Configuration and polarity guide position> 4: No polarity guide for 10 contact type, types with other number of have 1 polarity guide in middle. 9: Polarity guide in middle for 10 contact type. 1 1 <pplicable cable> Nil: Without contact 2: Pressure welding WG#22 to #24 3: Pressure welding WG#26 to #28 <Surface treatment (Pressure welding portion/terminal portion)> Nil: Without contact 1: u plating/sn plating <Package form> : Individual package

XW 2. Socket (Set) 3: Wire-press sockets (Set) < (2 digits)> <Cover shape> 1: Semi-covers 2: Vertical type hood cover 3: ngle type hood cover XW <Configuration and polarity guide position> 4: No polarity guide for 10 contact type, types with other number of have 1 polarity guide in middle. 9: Polarity guide in middle for 10 contact type. <pplicable cable> Nil: Without contact 2: Pressure welding WG#22 to #24 3: Pressure welding WG#26 to #28 <Surface treatment (Pressure welding portion/terminal portion)> Nil: Without contact 1: u plating/sn plating <Package form> : Individual package 3 1 3. Cover 6: Wire-press sockets (Cover) < (2 digits)> <Connecting wires> 0: Pressure welding method <Cover shape> 1: Semi-covers 2: Vertical type hood cover 3: ngle type hood cover <Package form> : Individual package XW 6 0 4. Contact 7: Wire-press sockets (Contact) <Sales form> 2: 5 in line <pplicable cable> 2: Pressure welding WG#22 to #24 3: Pressure welding WG#26 to #28 XW 7 2 1 <Surface treatment (Pressure welding portion/terminal portion)> 1: u plating/sn plating

8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 WIRING ND SSEMBLY 1. When using small amounts (about 150 pins can be pressure welding per hour) 1. Bend the contact back from the carrier, and set it in the pressure welding tool. 2. Insert the wire without removing its insulation unit it stops, and lightly grip the tool. 3. fter press-fitting the wire, insert it into housing. XW 4. ttach the cover to complete the operation. (Note) Necessary parts Process Stapler type XY52000 Contacts (5 in line) Separate wires Housing without Vertical type hood cover block Note) There are 3 types of cover: semi-covers, vertical type hood cover blocks, and angle type hood cover blocks. 2. When using medium to large amounts (when using pliers-type pressure welding tool, about 450 pins per hour) 1. Set the housing with contact in the pressure welding tool. 2. Insert the wires with insulation attached, until they touch the back, then use the tool s pressure welding operation. 3. ttach the cover to complete the operation. (Note) Process Necessary parts Housing with Pliers-type XY51000 Separate wires Note) There are 3 types of cover: semi-covers, vertical type hood cover blocks, and angle type hood cover blocks. Vertical type hood cover block

8 7 6 5 4 3 2 1 XW PPLICBLE HEDERS ND COMBINTIONS Pressure socket for separate wires Vertical type hood cover block ngled type hood cover block + Semi-cover Note) With cover installed on socket 7.4mm high type pplicable headers 2.54mm high type Long lever type MIL header Box type low profile header Open type low profile header Combinations Note) Loose wires omitted from photos

PRODUCT TYPES 1. Individual parts (Standard) Housing Cover Type Housing with Note) Suitable for use of pliers type or desktop type pressure welding tool. Housing without Note) Suitable for use of stapler-type pressure welding tool. Hood cover block Semi-cover Vertical type ngled type Contacts (5 in line) (Notes 5 and 6) 5 10 10 Part No. pplicable cable WG #22, 24 WG #26, 28 XW110421 (Without polarity guide) XW110921 (With polarity guide) XW110431 (Without polarity guide) XW110931 (With polarity guide) 14 XW114421 XW114431 16 XW116421 XW116431 20 XW120421 XW120431 26 XW126421 XW126431 30 XW130421 XW130431 34 XW134421 XW134431 40 XW140421 XW140431 50 XW150421 XW150431 60 XW160421 XW160431 64 XW164421 XW164431 10 XW1104 (Without polarity guide) 10 XW1109 (With polarity guide) 14 XW1144 16 XW1164 20 XW1204 26 XW1264 30 XW1304 34 XW1344 40 XW1404 50 XW1504 60 XW1604 64 XW1644 16 XW61602 20 XW62002 26 XW62602 30 XW63002 34 XW63402 40 XW64002 50 XW65002 60 XW66002 64 XW66402 26 XW62603 30 XW63003 34 XW63403 40 XW64003 50 XW65003 60 XW66003 64 XW66403 10 XW61001 14 XW61401 16 XW61601 20 XW62001 26 XW62601 30 XW63001 34 XW63401 40 XW64001 50 XW65001 60 XW66001 64 XW66401 XW7221 (for WG #22, 24) XW7231 (for WG #26, 28) Inner carton XW Notes) 1. The parts above are packaged individually. (Contact is tray packing) 2. The vertical type hood cover block is packaged with two covers (one with nuts), one wire bunding metal. 3. The angled type hood cover block is packaged with two covers and one wire bunding band. 4. The angled type hood cover for less than 20 and the vertical type hood cover for less than 14 are not available. Please use the semi-cover. 5. There is a mark 22 on for WG #22 and #24, and mark 26 for WG #26 and #28. 6. Remarks for 1) Reel packaging is available. Wire bunding metal Screw M2.6 Packing Outer carton 100 pcs. 400 pcs. 100 pcs. 400 pcs. 100 pcs. 400 pcs. 50 pcs. 200 pcs. 50 pcs. 200 pcs. 100 pcs. 400 pcs. 40 rows (200pcs.) 400 rows (2,000 pcs.) Wire bunding band

XW 2. Set products (produced after order) Set products are produced after an order is received, so if you have a tight deadline, please order the products on the above as stand-alone products. Set product Part No. Type pplicable cable Socket Cover WG #22, 24 WG #26, 28 16 XW3162421 XW3162431 20 XW3202421 XW3202431 26 XW3262421 XW3262431 30 XW3302421 XW3302431 Vertical type hood cover block 34 XW3342421 XW3342431 40 XW3402421 XW3402431 50 XW3502421 XW3502431 60 XW3602421 XW3602431 64 XW3642421 XW3642431 26 XW3263421 XW3263431 30 XW3303421 XW3303431 34 XW3343421 XW3343431 ngled type hood cover block 40 XW3403421 XW3403431 50 XW3503421 XW3503431 Full set Housing with 60 XW3603421 XW3603431 (Note 1) 64 XW3643421 XW3643431 Half-set (Note 2) Housing without Semi-cover Vertical type hood cover block ngled type hood cover block 10 10 XW3101421 (Without polarity guide) XW3101921 (With polarity guide) XW3101431 (Without polarity guide) XW3101931 (With polarity guide) 14 XW3141421 XW3141431 16 XW3161421 XW3161431 20 XW3201421 XW3201431 26 XW3261421 XW3261431 30 XW3301421 XW3301431 34 XW3341421 XW3341431 40 XW3401421 XW3401431 50 XW3501421 XW3501431 60 XW3601421 XW3601431 64 XW3641421 XW3641431 16 XW31624 20 XW32024 26 XW32624 30 XW33024 34 XW33424 40 XW34024 50 XW35024 60 XW36024 64 XW36424 26 XW32634 30 XW33034 34 XW33434 40 XW34034 50 XW35034 60 XW36034 Inner carton 64 XW36434 10 XW31014 (Without polarity guide) 10 XW31019 (With polarity guide) 14 XW31414 16 XW31614 20 XW32014 Semi-cover 26 XW32614 30 XW33014 34 XW33414 40 XW34014 50 XW35014 60 XW36014 64 XW36414 Notes) 1. Full-set products (Housing with contact and cover included) (1) Suitable for use with pliers type. (2) Produced after an order is received. If you are in a hurry, please order a housing with contact and cover separately from the list above. 2. Half-set products (Housing without contact and cover included) (1) Suitable for use with stapler-type pressure welding tool (2) s half-sets do not include a contact, order the appropriate stand-alone contact from the list above. (3) Produced after an order is received. If you are in a hurry, please order a housing without contact, and cover separately from the list on page 235. Packing Outer carton 50 pcs. 200 pcs. 50 pcs. 200 pcs.

SPECIFICTIONS 1. Characteristics Electrical characteristics Mechanical characteristics Life time characteristics Environmental characteristics 2. Materials and surface treatment Part name Materials Surface treatment Housing Glass fiber reinforced PBT (UL94V-0) Semi-cover Glass fiber reinforced PBT (UL94V-0) Cover Glass fiber polycarbonate resin (UL94V-0) Hood cover Vertical type hood cover (16, 20 contact) Contact portion: Contact Copper alloy Ni plating on base, u plating on surface Contact pressure portion: Ni plating on base, Sn plating on surface Lead wire bundling metal (enclosed with vertical type hood cover) Steel plate Lead wire bundling band (enclosed with angled type hood cover) Polyimide resin 3. pplicable cable No. Cross section area External figure Rated current Remarks WG#22 0.3 mm 2 3 12 wires/0.18 should used 1.5 to 1.1 dia. WG#24 0.2 mm 2 3 WG#26 0.14mm 2 2 1.3 to 1.1 dia. WG#28 0.08mm 2 1 XW Item Specifications Conditions Rated current WG#22, 24: 3, WG#26: 2, WG#28: 1 Rated voltage 250V C Breakdown voltage 1,000V C for 1 min. Detection current: 1m Insulation resistance Min. 1,000MΩ Using 500V DC megger Contact resistance Max. 20mΩ Measured based on the HP4338B measurement method of JIS C 5402 Unit removal force Min. 0.343N {35gf} Measured by steel-pin-gauge with 0.64±0.01mm square (surface roughness 0.1µm) Composite insertion force Max. 2.94N {300gf} Insertion and removal life 500 times Repeat insertion and removal speed of max. 600 times/hour mbient temperature 50 C to 105 C Vibration resistance Shock resistance Double amplitude: 1.52mm Frequency: 10 to 55Hz (for 3 axes) 490m/s 2 {50G} (for 3 axes) No freezing at low temperatures mbient temperature of cables should be considered No interruption of current longer than 1µs (Max. carrying current 100m should be impressed during the test) No interruption of current longer than 1µs (Max. carrying current 100m should be impressed during the test) DIMENSIONS (Unit: mm) Housing with CD Data The CD data of the products with a CD Data mark can be downloaded from: http:// Dimension table (mm) Polarity guide 10 0 17.3 10.16 10 1 17.3 10.16 14 1 22.4 15.24 16 1 24.9 17.78 20 1 30.0 22.86 26 1 37.6 30.48 30 1 42.7 35.56 34 1 47.8 40.64 40 1 55.4 48.26 50 1 68.1 60.96 60 1 80.8 73.66 64 1 85.9 78.74 B 14.5±0.2 14.2 6.0±0.2 B±0.2 General tolerance: ±0.3 Note) Dimensions of the housing without contact is the same as the right figure.

XW Socket 1) When vertical type hood covers are mated (16, 20, 26, 30, 34, 40, 50, 60 and 64 ) CD Data 16 and 20 26 to 64 Cover M2.6 screw Wire bunding metal 9.6 Screw Nut Wire bunding metal 12.0 Dimension table (mm) D D B C D 16 24.0 24.92 17.78 33.5 20 27.8 30.0 22.86 33.5 26 28.5 37.6 30.48 33.5 30 33.5 42.7 35.56 33.5 34 38.6 47.8 40.64 33.5 40 43.6 55.4 48.26 41.5 50 56.0 68.1 60.96 41.5 60 68.7 80.8 73.66 41.5 64 73.8 85.9 78.74 41.5 B C±0.2 22.7 14.2 14.5±0.2 7.5 6.0±0.2 8.0 B C±0.2 20.6 14.2 14.4±0.2 7.5 6.0±0.2 8.0 General tolerance: ±0.3 2) When angle type hood covers are mated (26, 30, 34, 40, 50, 60 and 64 ) CD Data 12.0 D 3) When semi-covers are mated CD Data 22.7 Dimension table (mm) 14.2 14.5±0.2 B C D 7.5 26 40.5 37.5 30.48 41.5 B 6.0±0.2 30 45.6 42.6 35.56 41.5 C±0.2 8.0 34 50.7 47.7 40.64 41.5 40 62.5 55.3 48.26 52.5 50 75.2 68.0 60.96 52.5 60 87.9 80.7 73.66 52.5 64 93.0 85.8 78.74 52.5 General tolerance: ±0.3 Dimension table (mm) B 8.0 10 17.3 10.16 16.5 14 22.38 15.24 14.5±0.2 16 24.92 17.78 14.2 7.5 20 30.0 22.86 26 37.62 30.48 6.0±0.2 30 42.7 35.56 34 47.78 40.64 B±0.2 40 55.4 48.26 50 68.1 60.96 60 80.8 73.66 64 85.88 78.74 General tolerance: ±0.3

4) Contacts (5 in line) CD Data 5.08 4=20.32 2.54 5.08 26 XW 16.7 Position of the breaking Note) On the there are stamps 22 for WG #22 and #24 types, and 26 for WG #26 and #28 types. General tolerance: ±0.3 NOTES 1. Use wires and contact types that match. The contact s clamp is tamped with 22 or 26. Use WG#22 or #24 wire with the type 22 contact and WG #26 or #28 wire with the type 26 contact. n incorrect combination will cause faulty connections. 2. Use wires having a correct outer insulation diameter. The use of a wire with an outer insulation diameter larger than the allowable value or a wire with a hard material for the insulation will cause faulty connections. Furthermore, the use of a wire with an outer insulation diameter less than the allowable value will cause a drop in the clamp strength. Use wires with a suitable outer diameter and insulation material. Suitable wire diameters are shown in the table below. Suitable wire diameters Insulation Size outer Remark diameter WG#22 WG#24 WG#26 WG#28 1.5 dia. to 1.1 dia. 1.3 dia. to 1.1 dia. WG #22 is Stranded wire of 12 stands/0.18 Stranded wire Stranded wire *WG#22 and #24 use different from WG#26 and #28. Refer to the part number chart for the part number. 3. Inserted wire length during wire pressure welding Insert the wire to a proper length and perform the pressure welding. If the inserted length is too short, the wire will be pressure welded only at one location. If the inserted length is too long, the wire will end up on the lance portion and a proper pressure welding will not be obtained. 4. Cut the end of the wire so that it is straight and flat. Be sure no uneven strands remain. 5. When pressure welding a wire, fully insert it to the proper position. Be sure to squeeze the lever unit it reaches the end position of the stroke. 6. fter connecting the wire, check that the wire clamp firmly clamps the wire. 7. It may not be possible to cut a contact from the carrier by folding the contact only once. 8. The contact holder should be replaced as needed. For other details, please verify with the product specification sheets.

XW PRESSURE WELDING TOOLS FOR SEPRTE WIRES PRODUCT TYPES Packaging Product name Part No. Inner carton Outer carton Pliers type pressure welding tool for separate wires (with feed mechanism) XY51000 Pressure welding tool 1 pc. Stapler type pressure welding tool for separate wires XY52000 ccessory Contact holder XY5801 200 pcs. Pliers-type (with feed mechanism) 47 200 Pliers-type pressure welding tool for separate wires (with feed mechanism) XY51000 90 mm Compliance with RoHS Directive FETURES 1. Weight balanced design for lightweight handling. 2. Lever Lock Mechanism llows Reliable Pressure Welding The lever lock mechanism prevents the lever from returning until the predetermined stroke is reached. This allows for reliable pressure welding, preventing variation due to differences between individual workers. 3. utomatic feed mechanism indicates the pressure welding terminal number after a pressure welding. fter each pressure welding, the automatic feed is performed one pitch at a time (2.54mm). t the same time, the number of the connector terminal being pressure-welded is indicated. If the terminal number is set initially, the connector can be moved to any position with the correct terminal number always displayed since the tool is directly linked with the connector. 4. Stroke adjustment feature. The pressure welding stroke can be adjusted to match the diameter of the cable wire for reliable connections. 5. Enables pressure welding of both the socket with ans individual. cable can be connected with the positioned in the socket housing (socket housing with ) or with the individual separated from the socket housing. 6. Contact puller feature. The contact puller permits incorrectly connected or unnecessary to be pulled out. Stapler type 18 69.5 Stapler type pressure welding tool for separate wires XY52000 90 mm FETURES 1. Compact and lightweight, it fits in a pocket. 2. Pressure-weld individual. 3. Convenient for on-site maintenance work since connection is possible in small spaces. 4. Includes a contact puller. Compliance with RoHS Directive NOTES 1. Never disammenble the tool. lso, do not subject it to shock or drop it from a high place. For other details, please verify with the product specification sheets.