INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Similar documents
INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Installation Instructions for 45H & 47H Mortise Locks

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Installation Instructions

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

INSTALLATION INSTRUCTIONS CRL JACKSON

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Installation Instructions

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Tools Required. * When installing on a fire door, please see instructions below. *

Entry Mortise Handleset

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

Installation Instructions For The 8850FL Series Mortise eboss

MORTISE LOCK INSTALLATION INSTRUCTIONS

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

WD WD7000 Series

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS CRL JACKSON

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Installing Your Electronic Deadbolt

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

Installation Instructions

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Installation Instructions II-2/4/5K-0608

Entry Mortise Lock Set Lever to Lever

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

98/ Customer Service # Dogging Key (use to lock down pushbar)

LATCHBOLT FILLER PLATE ASA FILLER PLATE A. SINGLE DOOR B. DOUBLE DOOR WITH MULLION C. DOUBLE DOOR WITHOUT MULLION END COVER MOUNTING BRACKET

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

7130(F) Series Mortise Exit Devices Installation Instructions

Passage Mortise Lock Set Lever to Lever

PMR ELECTRONIC LOCK USER GUIDE

INSTALLATION INSTRUCTIONS

Installation Instructions

Shetland Stalls Installation Instructions

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Certification Exhibit FCC ID: U4A-SCYPROX2 IC: 6982A-SCYPROX2. FCC Rule Part: IC Radio Standards Specification: RSS-210

CrossOver X25 Lock Installation Need another copy of these installation sheets? You can download one at

For New or Retrofit Construction Retrofits Existing ANSI 4-7/8 Strike Prep No Centerline Relocation

1530(F) Mortise Exit Devices Installation Instructions

8800 Series Mortise Lockset Knob, Lever, Reflections and Security Trims Installation Instructions

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

P USHbutton 500 series

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

Senior Swing. Caution

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

This is a printable pdf document. For Smartphone-friendly version, tap or click here.

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

WOOD DOOR INSTALLATION

MORTISE LOCKS LA1Tx7 //DATASHEET

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

DOOR TECHNOLOGY ORDER CATALOG SECTION Tools & Accessories for Door Lock Installation

CL4500 Installation Instructions

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

MORTISE LOCK INSTALLATION INSTRUCTIONS

Door Hardware Installation Instructions. For Assistance Call:

Melamine Plastic Laminate. Toilet Partition Installation Manual

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

INSTRUCTIONS FOR HIT LOCK MORTISER

INSTALLATION INSTRUCTIONS

Installation Instructions For Profile Series v.g1 Exit Device

Jenny Legs Assembly Instructions

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

ES8000-S V-LOCK ELECTRICAL SPECIFICATION INSTALLATION INSTRUCTIONS

Installation Instructions

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

Preference Collection and Treatment Console INSTALLATION GUIDE

Installation Instructions For Profile Series v.g1 Cylindrical Lock

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

Finish Hardware. Contents. Section 10

BEFORE STARTING INSTALLATION

Rim-Lock Door Set Installation Instructions

MORTISE LOCKS RESIDENTIAL SERIES

Sentinel Series Cigar Humidor End Tables

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Installation Manual for Metal Toilet Partitions Standard Series

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

(Wood Door and Frame)

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

Dublin Stalls Installation Instructions

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

Transcription:

801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com A. Door Preparation: INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK 1. Measure desired height from finished floor, mark a horizontal line on door and door edge. 2. Align template on edge of door with applicable horizontal at height line. Check the chart for drilling trim holes on template and mark only holes for lock function being installed. of door edge Height line of lever or knob Installation template of cylinder of lockcase of lever or knob Vertical centerline 3. Mortise door edge according to measurements on installation template and drill proper holes for trim. 4. Recess for face plate, the dimension is: L 8-1/32" x W 1-5/16" x D 7/32". OPTIONAL DOOR CORE DRILLING GUIDE #7000-DG 7/32" P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

B. Strike Installation: 1. Align strike template on jamb. Be sure to keep 3/8" distance between lock centerline and strike centerline. Recess 5/32" for flush fit of strike and dust box. 2. Mortise jamb according to measurement of strike template. Then fit strike and dust box into frame and secure into place with supplied screws. Jamb 4-7/8" 3-17/32" 1" Holes 1-1/8" Deep Strike C 3/8" L Lock 3/8" C. Install Lockcase Make sure the lock hand matches the door hand, use the following diagram to determine the hand of door. LH Left Hand INSIDE OF DOOR RH Right Hand OUTSIDE OF DOOR INSIDE OF DOOR LHRB Left Hand Reverse Bevel OUTSIDE OF DOOR RHRB Right Hand Reverse Bevel P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 2

C. Install Lockcase (Continued) Instructions for changing lock hand: 1. Change latchbolt handing If the hand of the latchbolt doesn t match the door hand, remove the fixing screw and pull the latchbolt out from lock case. Turn the latchbolt 180 to change the handling. Position latchbolt back, into case and fasten it. Remove screw Pull out and turn 2. Change hand of lock For RH and RHRB, the catch screw will be on the lock case side. For LH and LHRB, the catch screw will be on the lock cover side. P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 3

C. Install Lockcase (Continued) 3. Connect wires as shown on the lock cover diagram. 4. Insert lockcase into mortise cut-out and fasten screws to door. D. Install Spindles 1. Insert spindle into outside hub of lock. 2. Insert inside spindle and tighten screw into outside spindle. E. Install Lever trim 1. Place the reversible spring cage onto the ferrules with arrow pointing in direction of lever rotation. 2. Install outside trim with mounting posts through door and position lever onto the spindle. Reversible spring cage Ferrule Mounting post Screw post P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 4

E. Install Lever trim (Continued) 3. Install inside spring cage onto the spindle with the arrow pointing in the direction of inside lever rotation. 4. Install inside mounting plate onto spindle. Tighten with provided screw. 5. Cap inside rose over mounting plate. 6. Screw inside lever into position and tighten lever collar with spanner wrench. Spanner wrench F. Install Cylinder and Armor Face Plate 1. Screw cylinder into threaded hole of lock case. 2. Tighten the setting screw against cylinder(s) by turning clockwise as shown. 3. Install face plate onto lock case front and fasten with supplied screws. USE THIS CAM. P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 5

INSTALLATION WIRE DIAGRAM Model 7800 Series 12/24VDC STANDARD WIRING MOV* + - RED BLK BLU WHT 12 VDC @.6 AMP MOV* + - RED BLK BLU WHT 24 VDC @.3 AMP LATCHED AND LOCKED STATUS DOOR POSITION STATUS REQUEST-TO-EXIT OUTPUT LLS DPS REX COM SECURE UNSECURE COM NC NO COM NC NO FROM LOCK WHT/BLK ORG/BLK YEL/BLK WHT ORG YEL WHT/RED ORG/RED YEL/RED Dual Coil Solenoid *Install MOV across coil to protect ACS electronics. Install as close as possible to the lock Optional Monitoring WIRING WITH OPTIONAL CABLE AND CONNECTOR MOV* + - RED BLK GRN WHT 12 VDC @.6 AMP MOV* + - RED BLK GRN WHT 24 VDC @.3 AMP LATCHED AND LOCKED STATUS DOOR POSITION STATUS REQUEST-TO-EXIT OUTPUT LLS DPS REX COM SECURE UNSECURE COM NC NO COM NC NO FROM LOCK CABLE ORG BRN YEL RED/YEL RED/BLU RED/GRN VIO GRY PNK Dual Coil Solenoid *Install MOV across each coil to protect ACS electronics. Install as close as possible to the lock Optional Monitoring P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 6

FAIL SAFE/FAIL SECURE CONVERSION Procedure To Change SDC Fail Safe Solenoid To Fail Secure Fail Safe Assembly Remove fail safe solenoid Disassemble fail safe solenoid by unscrewing rod tip assembly from plunger. Fail safe Plunger Solenoid body Rod tip assy. Spring and washer supplied in case for fail secure conversion. Fail Secure Assembly Insert washer and spring onto rod tip assembly and screw into plunger until it bottoms out. Insert plunger/rod tip into solenoid. Solenoid body Plunger Replace solenoid in holder as shown. Spring Washer Rod tip assy. Fail secure P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 REV D 10-13 Page 7

801 Avenida Acaso, Camarillo, Ca. 93041 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com A. Door Preparation: INSTALLATION INSTRUCTIONS 12VDC Z7835 SERIES MORTISE LOCK 1. Measure desired height from finished floor, mark a horizontal line on door and door edge. 2. Align template on edge of door with applicable horizontal at height line. Check the chart for drilling trim holes on template and mark only holes for lock function being installed. of door edge Height line of lever or knob Installation template of cylinder of lockcase of lever or knob Vertical centerline 3. Mortise door edge according to measurements on installation template and drill proper holes for trim. 4. Recess for face plate, the dimension is: L 8-1/32" x W 1-5/16" x D 7/32". OPTIONAL DOOR CORE DRILLING GUIDE #7000-DG 7/32" P:\INSTALLATION INST\Electrified Lockset\INST-Z7835-E (12VDC) REV A 05-13 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

B. Strike Installation: 1. Align strike template on jamb. Be sure to keep 3/8" distance between lock centerline and strike centerline. Recess 5/32" for flush fit of strike and dust box. 2. Mortise jamb according to measurement of strike template. Then fit strike and dust box into frame and secure into place with supplied screws. Jamb 4-7/8" 3-17/32" 1" Holes 1-1/8" Deep Strike C 3/8" L Lock 3/8" C. Install Lockcase Instructions for changing latchbolt handing: 1. Change latchbolt handing If the hand of the latchbolt doesn t match the door hand, remove the fixing screw and pull the latchbolt out from lock case. Turn the latchbolt 180 to change the handling. Position latchbolt back, into case and fasten it. Remove screw Pull out and turn P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (12VDC) REV A 05-13 Page 2

C. Install Lockcase (Continued) 2. Connect wires as shown on the lock cover diagram. 3. Insert lockcase into mortise cut-out and fasten screws to door. D. Install Spindles 1. Insert spindle into outside hub of lock. 2. Insert inside spindle and tighten screw into outside spindle. E. Install Lever trim 1. Place the reversible spring cage onto the ferrules with arrow pointing in direction of lever rotation. 2. Install outside trim with mounting posts through door and position lever onto the spindle. Reversible spring cage Ferrule Mounting post Screw post P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (12VDC) REV A 05-13 Page 3

E. Install Lever trim (Continued) 3. Install inside spring cage onto the spindle with the arrow pointing in the direction of inside lever rotation. 4. Install inside mounting plate onto spindle. Tighten with provided screw. 5. Cap inside rose over mounting plate. 6. Screw inside lever into position and tighten lever collar with spanner wrench. Spanner wrench F. Install Cylinder and Armor Face Plate 1. Screw cylinder into threaded hole of lock case. 2. Tighten the setting screw against cylinder(s) by turning clockwise as shown. 3. Install face plate onto lock case front and fasten with supplied screws. USE THIS CAM. P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (12VDC) REV A 05-13 Page 4

INSTALLATION WIRE DIAGRAM Model Z7835 Series 12VDC ONLY STANDARD WIRING (NO OPTIONS) MOV* + + - 12VDC RED OUTSIDE BLK INSIDE NOT USED WHT 4 PIN CONECTOR *Install MOV across each coil to protect ACS electronics. Install as close as possible to the lock DPS REX LLS GREEN COM BLACK N/C WHITE N/O ORANGE COM BROWN N/C YELLOW N/O RED/YELLOW COM RED/BLACK SECURE RED/GREEN UNSECURE WIRING WITH OPTIONS SOLENOID VIOLET (+) OUTSIDE SOLENOID GREY (-) OUT/INSIDE SOLENOID PINK (+) INSIDE SOLENOID MOV* NOT USED *Install MOV across each coil to protect ACS electronics. Install as close as possible to the lock P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (12VDC) REV A 05-13 Page 5

801 Avenida Acaso, Camarillo, Ca. 93041 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com A. Door Preparation: INSTALLATION INSTRUCTIONS 24VDC Z7835 SERIES MORTISE LOCK 1. Measure desired height from finished floor, mark a horizontal line on door and door edge. 2. Align template on edge of door with applicable horizontal at height line. Check the chart for drilling trim holes on template and mark only holes for lock function being installed. of door edge Height line of lever or knob Installation template of cylinder of lockcase of lever or knob Vertical centerline 3. Mortise door edge according to measurements on installation template and drill proper holes for trim. 4. Recess for face plate, the dimension is: L 8-1/32" x W 1-5/16" x D 7/32". OPTIONAL DOOR CORE DRILLING GUIDE #7000-DG 7/32" P:\INSTALLATION INST\Electrified Lockset\INST-Z7835-C (24VDC) REV D 05-13 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

B. Strike Installation: 1. Align strike template on jamb. Be sure to keep 3/8" distance between lock centerline and strike centerline. Recess 5/32" for flush fit of strike and dust box. 2. Mortise jamb according to measurement of strike template. Then fit strike and dust box into frame and secure into place with supplied screws. Jamb 4-7/8" 3-17/32" 1" Holes 1-1/8" Deep Strike C 3/8" L Lock 3/8" C. Install Lockcase Instructions for changing latchbolt handing: 1. Change latchbolt handing If the hand of the latchbolt doesn t match the door hand, remove the fixing screw and pull the latchbolt out from lock case. Turn the latchbolt 180 to change the handling. Position latchbolt back, into case and fasten it. Remove screw Pull out and turn P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (24VDC) REV D 05-13 Page 2

C. Install Lockcase (Continued) 2. Connect wires as shown on the lock cover diagram. 3. Insert lockcase into mortise cut-out and fasten screws to door. D. Install Spindles 1. Insert spindle into outside hub of lock. 2. Insert inside spindle and tighten screw into outside spindle. E. Install Lever trim 1. Place the reversible spring cage onto the ferrules with arrow pointing in direction of lever rotation. 2. Install outside trim with mounting posts through door and position lever onto the spindle. Reversible spring cage Ferrule Mounting post Screw post P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (24VDC) REV D 05-13 Page 3

E. Install Lever trim (Continued) 3. Install inside spring cage onto the spindle with the arrow pointing in the direction of inside lever rotation. 4. Install inside mounting plate onto spindle. Tighten with provided screw. 5. Cap inside rose over mounting plate. 6. Screw inside lever into position and tighten lever collar with spanner wrench. Spanner wrench F. Install Cylinder and Armor Face Plate 1. Screw cylinder into threaded hole of lock case. 2. Tighten the setting screw against cylinder(s) by turning clockwise as shown. 3. Install face plate onto lock case front and fasten with supplied screws. USE THIS CAM. P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (24VDC) REV D 05-13 Page 4

INSTALLATION WIRE DIAGRAM Model Z7835 Series 24VDC ONLY STANDARD WIRING (NO OPTIONS) MOV* MOV + + - 24VDC RED OUTSIDE NOT USED BLK INSIDE WHT 4 PIN CONECTOR *Install MOV across each coil to protect ACS electronics. Install as close as possible to the lock DPS REX LLS GREEN COM BLACK N/C WHITE N/O ORANGE COM BROWN N/C YELLOW N/O RED/YELLOW COM RED/BLACK SECURE RED/GREEN UNSECURE WIRING WITH OPTIONS VIOLET (+) OUTSIDE SOLENOID SOLENOID GREY (-) OUT/INSIDE SOLENOID PINK (+) INSIDE SOLENOID MOV* NOT USED *Install MOV across each coil to protect ACS electronics. Install as close as possible to the lock P:\INSTALLATION INST\Electrified Lockset\INST-Z7835 (24VDC) REV D 05-13 Page 5