Pharma Temperature Sensor G3/8"

Similar documents
Pharma Temperature Sensor G3/8"

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor with M12 hygienic

Temperature Sensor with Thread G1/4" FLEXadapt

Temperature Sensor Tri-Clamp

Temperature Sensor Tri-Clamp

Temperature Sensor G1/2" Standard

Temperature Sensor without thread

Pharma-Temperature Sensor M12 hygienic

Temperature Sensor with M12 hygienic

Temperature Sensor G1/2" Standard

Temperature Sensor with G1/2" hygienic

Temperature Sensor Tri-Clamp

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Pharma Temperature Sensor TFP-EX

Inductive Conductivity Meter ILM

Capacitive Limit Switch Pharma NCS

Continuous Level Sensor NSL-M

Capacitive Limit Switch Pharma NCS

Capacitive Limit Switch Pharma NCS

Continuous Level Sensor NSL-M-00

Magnetic-Inductive flow Meter fmi

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

ph or ORP Transmitter

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Resistance thermometer Model TR30, compact design

Digital inductive conductivity transmitter

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Model TR33, thread-mounted

Conductivity Transmitter

Screw-in resistance thermometers with plug connector

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Valve Island with Electronic I/O

Digital flow ELEMENT transmitter for continuous flow measurement

ED701 General Industry Pressure Transmitter

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

In-Line Resistance Thermometers Model TR25

Resistance thermometer Model TR30, compact design

Digital flow ELEMENT transmitter for continuous flow measurement

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Resistance thermometer Model TR31, miniature design

Pressure transmitter for general industrial applications Model A-10

Technical Information Smartec CLD18

OPTITEMP TT 20 Technical Datasheet

Technical Information Smartec CLD18

Resistance Thermometers Model Series TR7X0, Sheathed Design

Electromagnetic Flow Transmitter

INLINE flowmeter for continuous flow measurement

Technical Information Smartec CLD18

Operating Instructions for Microwave Level Switch. Model: LNM

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Digital flowmeter for continuous flow measurement

Pressure transmitter for general industrial applications Model A-10

Digital conductivity transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

CombiTemp TCR6 Standard RTD temperature sensor

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

INLINE flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

Technical Information Memosens CLS82D

omnigrad M TR 46 Technical Information Hygienic in-line RTD thermometer PCP ( ma), HART or PROFIBUS-PA electronic

Digital flowmeter for continuous flow measurement

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

The transducer component converts the measured signal and displays the actual value.

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Mineral-insulated resistance thermometers to EN

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure transmitter For general industrial applications Model A-10

INSERTION paddle wheel flowmeter for continuous flow measurement

Hygro-ThermoTransmitter-compact xxx

Ultrasonic level transmitter, non-contact

Pressure and level transmitter PASCAL CV LEVEL,

INLINE flowmeter for continuous flow measurement

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Resistance thermometers for process technology

Technical Information Condumax CLS15D/CLS15

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Electrical Temperature Measurement

Flush pressure transmitter For viscous and solids-containing media Model S-11

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

In-line resistance thermometer Model TR25

Conductivity sensor for hygienic applications

prosonic T FMU230, FMU231

Ceramax CPS341D. Technical Information

Digital batch controller

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Pressure transmitter For general industrial applications Model A-10

In-Line Resistance Thermometers Model TR472

Condumax W CLS15 and CLS15D

Flow Measurement SITRANS F M

Transcription:

1 Product Information TFP-58P, -68P, -168P, -188P Pharma Temperature Sensor G3/8" P H A R M A Application / Specified Usage Aseptic temperature measurement, inline, high precise and fast without product contact Temperature measuring in pipes and vessels without opening the process with prefabricated thermowells and build-in systems Demounting the sensor without opening the process and without electrical disconnection > avoiding downtime of the equipment at calibration and maintenance! Suitable at small pipe diameters with build-in system ESP (available for pipes DN25...DN100) Authorisations Temperature sensor TFP-58P Application Examples Flexible applicable for nearly every temperature measuring task in pipes and vessels Safe temperature measuring in hotsteam- and pressure pipes (enclosed process) Monitoring of CIP- / SIP-cleaning Hygienic Design / Process Connection Hygienic and easy sterilizable installation by using Negele build-in system ESP CIP-/ SIP-cleaning up to 140 C All wetted materials compliant to FDA Sensor completely made of stainless steel 3-A approval for build-in system ESP-G DN25, ISO20, G1" and ESP-E available Features Short reaction time, very compact measure point Integrated transmitter (optional) Spring mounted gauge slide at TFP-58P Spring mounted sensor tip at TFP-168P and TFP-188P Weight reduced connecting head: non-sensitive to vibrations, hygienic design Electrical connection via M12-plug Material (1.4435), inspection certificate 3.1 in scope of delivery (for all product contacting parts) Quick and easy to install with an orbital welding machine Temperature sensors and build-in system with predefined and concerted standard lengths reducing product variants and saving storage costs and simplify maintenance Protection class IP 69 K Temperature sesor TFP-168P with build-in system ESP-G Options / Accessories 2 x Pt100 (not retrofittable) 2 x Pt100 with two transmitters (not retrofittable) Programmable transmitter MPU-4 and MPU-M with output 4...20 ma, 2-wire Transmitter Profibus PA and HART protocol Programming adapter MPU-P 9701 Transmitter MPU-LCD with integrated display in connecting head Pt100-chip with other classes of accuracy, (1/3 B, 1/10 B) Preassebled cable for M12-plug Fixed cable for TFP-188P in other length and material available NEGELE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720

P H A R M A Specification 2 Temperature Sensor Process Connection build-in system ESP with G3/8" external thread and thermowell Insertion Length standard 37 mm, 83 mm, 97 mm, 160 mm Materials connection head stainless steel 1.4305 (303) protection tube stainless steel 1.4404 cap nut stainless steel 1.4571 spacer stainless steel 1.4301, Ø 10 mm Temperature Ranges ambient -50...+80 C sensor tip -50...+250 C Operating Pressure 50 bar max. Sensing Resistor acc. to DIN EN 60751 1 x Pt100 class A Electrical Connection cable gland M16 x 1,5 cable connection M12-plug 1.4305, 4-pin fixed cable (2,5 m) PTFE 4 x 0,14 mm² Protection Type IP 69 K (with electrical connection M12-plug) Transmitter MPU-4, MPU-10, MPU-H, MPU-M Temperature ranges ambient -40...+85 C storage -55...+90 C Measuring ranges MPU-4, MPU-H, MPU-M standard: -10...40 C, 0...50 / 100 / 150 / 200 C special ranges free programmable MPU-10 standard -200...850 C configuration occurs with Profibus Accuracy input < ±0,25 C Temperature drift zero, span < 0,01 % / K Supply MPU-M, MPU-4 8...35 V DC MPU-10 9...32 V DC accuracy 0,01 % / V (reference: 12 V DC) Output signal analog 4...20 ma (not for MPU-10) accuracy < ±0,1 % of measurement range burden < 600 Ω (at U B = 24 V) Humidity without condensation 0...98 % Accuracy classes of temperature sensors Tolerances for Pt100 acc. to DIN EN 60751 Pt100 A 1/3 B 1/10 B 0 C / 100 Ω ±0,15 K / ±0,06 Ω ±0,10 K / ±0,04 Ω ±0,03 K / ±0,01 Ω 100 C / 138,5 Ω ±0,35 K / ±0,13 Ω ±0,27 K / ±0,10 Ω ±0,08 K / ±0,03 Ω Table Reaction Time ESF-G-DIN2-10 Reaction Time Medium temperature 150 C t 50 4,4 s Medium temperature 150 C t 90 13,1 s We recommend to use heat-conductive paste. This can reduce the response time up to 50 %.

3 Electrical Connection P H A R M A Elektrischer Electrical connection Anschluss without ohne Kopftransmitter Elektrischer Electrical connection Anschluss with mit Kopftransmitter With 1 x M12 plug Belegung Configuration 1. M12-Stecker 1st plug 1 2 3 4 M12-Stecker With plug Configuration Belegung M12 plug M12-Stecker 1: + supply 2: - supply 4...20 ma 3: not connected 4: not connected With 2 x M12 plug Belegung Configuration 2. M12-Stecker 2nd plug 1 2 3 4 Mit With Kabelverschraubung cable gland 4...20 ma current loop 4...20 ma Stromschleife With cable gland Belegung Configuration Klemmen strip terminal 1 2 3 4 Electrical connection with two transmitter (TFP-68P) With fixed cable Klemmen clamps for für 1st 1. Pt100 Klemmen clamps for für 2nd 2. Pt100 (bei (at version Ausführung 2 x Pt100) 2 x Pt100) Belegung Fixed cable Kabel connection mit 1 with x Pt100 1 x Pt100 With 1 x M12-plug (sensor 1 + sensor 2) With 2 x M12-plug (sensor 1) Configuration M12-plug 1: + supply (sensor 1) 2: - supply 4...20 ma (sensor 1) 3: - supply 4...20 ma (sensor 2) 4: + supply (sensor 2) Configuration M12-plug 1: + supply (sensor 1) 2: - supply 4...20 ma (sensor 1) 3: not connected 4: not connected Belegung Kabel mit 2 x Pt100 (LIYY) Fixed Belegung cable Kabel connection mit with 2 x Pt100 2 x Pt100 (PTFE) (PTFE) With 2 x M12-plug (sensor 2) Configuration M12-plug 1: + supply (sensor 2) 2: - supply 4...20 ma (sensor 2) 3: not connected 4: not connected

P H A R M A Dimensioned Drawings 4 TFP-58P TFP-58P.2 TFP-68P /... / 2 x M12 TFP-168P /... TFP-168P /... / MPU-M TFP-188P /... Insertion length EL + 1 mm spring travel Insertion length EL + 1 mm spring travel Insertion length EL + 1 mm spring travel Insertion length EL + 2 mm spring travel

5 Advices P H A R M A Mechanical Connection / Installation To guarantee a definite function use the Negele PHARMadapt ESP system. Conventional Usage Not suitable for applications in explosive areas. Not suitable for applications in security-relevant equipments (SIL). Transport / Storage No outdoor storage Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage temperature -55...+90 C Relative humidity maximum 98 % Reshipment Sensors shall be clean and must not be contaminated with dangerous media and / or heat-conductive paste. Use suitable transport packaging only to avoid damage of the equipment! Cleaning / Maintenance In case of using pressure washers, dont t point nozzle directly to electrical connections! Standards and Guidelines You have to comply with applicable regulations and directives. Disposal This instrument is not subject to the WEEE directive 2002/96/EC and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. Advice to EMC The device agrees to following standards: EMC directive 2004/108/EG. You have to guarantee the EMC directives for the entire equipement. Conditions for a measuring point according to 3-A-Standard 74-03 The sensors TFP-58P, -68P, -168P, -188P don t need a 3-A approval, because they are not product contacting. Only with the build-in system ESP-G with tube diameter DN25, ISO 20 and G1 and ESP-E allowed. The welding seam by using of ESP-E has to correspond with 3-A-Standard 74-03, D6.1.4: The minimum radii for fillets of welds in product contact surfaces shall be not less than 1/4 in. (6.35 mm) except that the minimum radii for such welds may be 1/8 in. (3.18 mm) when the thickness of one or both parts joined is less than 3/16 in. (4.76 mm). Self draining has to be warranted by the build-in position (pos. 1, 2 or 3)

P H A R M A Accessories 6 Temperature Transmitter MPU-LCD with Display Application / Specified Usage 4...20mA transmitter with LCD for Pt100 temperature sensor For installation in temperature sensor Sensor monitoring Option MPU-LCD (display in the connection head) Features 4-digit display with green backlight Temperature measurement in C and F Easy range select by one button Lower costs for wiring because of 2-wire technology Note See product information MPU-LCD for details. Accessories PVC-cable with M12-connection PVC-cable with M12-connection made of 1.4305, IP 69 K, unshielded M12-PVC / 4-5 m PVC-cable 4-pin, length 5 m M12-PVC / 4-10 m PVC-cable 4-pin, length 10 m M12-PVC / 4-25 m PVC-cable 4-pin, length 25 m PVC-cable with M12-connection, brass nickel-plated, IP 67, shielded M12-PVC / 4G-5 m PVC-cable 4-pin, length 5 m M12-PVC / 4G-10 m PVC-cable 4-pin, length 10 m M12-PVC / 4G-25 m PVC-cable 4-pin, length 25 m Programming adapter MPU-P 9701 Programming adapter MPU-P 9701 Programming adapter for MPU-4, MPU-H and MPU-M Build-In systems Suitable build-in systems for temperature sensors TFP-58p, -68P, 168P, and -188P you will find in product information Process Connection PHARMadapt ESP.

7 Order Code P H A R M A Temperature sensor version with 1 x Pt100 TFP-58P TFP-168P TFP-188P (connecting head Ø 55 mm, 1 x Pt100, non-sensitive design to vibrations) (connecting head Ø 18 mm, 1 x Pt100, electrical connection via M12-plug) (connecting head Ø 18 mm, 1 x Pt100, electrical connection via 2,5 m PTFE-cable; no transmitter possible) Sensor length EL in mm 037 059 083 160 Accuracy class A 1/3B 1/10B Electrical connection only for TFP-58P PG M12 (cable gland M16x1,5) (M12-plug 1.4305, standard with MPU-LCD) Transmitter only for TFP-58P X (without) MPU-4 (programmable) MPU-10 (Profibus PA) MPU-H (HART-protocol) MPU-LCD (with display) Transmitter only for TFP-168P X (without) MPU-M (programmable) Measurement range (only for types with transmitter; not selectable at MPU-LCD) -10...40 0...50 0...100 0...150 0...200 xx...yy (measuring range -10...40 C) (measuring range 0...50 C) (measuring range 0...100 C) (measuring range 0...150 C) (measuring range 0...200 C) (special range) TFP-58P / 083 / A / M12 / MPU-4 / 0...100

P H A R M A Product Information TFP-58P, -68P, -168P, -188P 8 Temperature sensor version with 2 x Pt100 TFP-58P.2 TFP-68P (connecting head Ø 55 mm, 2 x Pt100, non-sensitive design to vibrations) (like TFP-58P.2, but with higher connecting head and prepared for 2 x transmitter) Sensor length EL in mm 037 059 083 160 Accuracy class Pt100 A 1/3B 1/10B Electrical connection only for TFP-58P.2 PG (cable gland M16x1,5) 2 x PG (2 x cable gland M16x1,5) 2 x M12 (2 x M12-plug 1.4305) Electrical connection only for TFP-68P M12 2 x M12 (M12-plug 1.4305) (2 x M12-plug 1.4305) Continue if TFP-68P is selected! No further options for TFP-58P.2! 1. Transmitter MPU-4 (programmable) Measuring range 1. MPU -10...40 0...50 0...100 0...150 0...200 xx...yy (measurement range -10...40 C) (measurement range 0...+50 C) (measurement range 0...+100 C) (measurement range 0...+150 C) (measurement range 0...+200 C) (special range) 2. Transmitter MPU-4 (programmable) Measuring range 2.MPU -10...40 0...50 0...100 0...150 0...200 xx...yy (range -10...40 C) (range 0...+50 C) (range 0...+100 C) (range 0...+150 C) (range 0...+200 C) (special range) TFP-68P / 083 / A / M12 / MPU-4 / 0...100 / MPU-4 / 0...100 04.08.11 / 2.0 / CV / at-ac.de Negele Messtechnik GmbH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720