High Efficiency Transformer less Inverter for Single-Phase Photovoltaic Systems using Switching Converter

Similar documents
HIGH EFFICIENCY TRANSFORMER LESS INVERTER FOR SINGLE-PHASE PHOTOVOLTAIC SYSTEMS USING SWITCHING CONVERTER

MPPT based New Transformer Less PV Inverter Topology with Low Leakage Current

High Efficiency Single Phase Transformer less PV Multilevel Inverter

Transformerless Grid-Connected Inverters for Photovoltaic Modules: A Review

Experimental Analysis of Single-Phase Non- Transformer Photovoltaic Inverter with Optimum Efficiency

IMPROVED TRANSFORMERLESS INVERTER WITH COMMON-MODE LEAKAGE CURRENT ELIMINATION FOR A PHOTOVOLTAIC GRID-CONNECTED POWER SYSTEM

International Journal of Research Available at

HIGH RELIABILITY AND EFFICIENCY OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS USING SINGLE-PHASETRANSFORMERLESS INVERTER. Abstract

Closed Loop Control of Boost Converter for a Grid Connected Photovoltaic System

Multilevel Inverter for Single Phase System with Reduced Number of Switches

Improved H6 Transformerless Inverter for PV Grid tied power system

Transformer less Grid Connected Inverter with Leakage Current Elimination

A High-Efficiency MOSFET Transformerless Inverter for Nonisolated Microinverter Applications

ISSN Vol.07,Issue.07, July-2015, Pages:

TRANSFORMERLESS THREE LEVEL DIODE CLAMPED INVERTER FOR SINGLE PHASE GRID CONNECTED PHOTOVOLTAIC SYSTEM

Power Electronic Converters for Grid-connected Photovoltaic Systems. Aravinda Perera Ezekiel Muyembe Jacobus Brink Muhammad Shahbaz

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Different Type of Inverter Topologies for PV Transformerless Standalone System

Analysis and Design of Solar Photo Voltaic Grid Connected Inverter

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

Photo Voltaic Systems Power Optimization under Cascaded Inverter Environment

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

Simulation of H6 full bridge Inverter for grid connected PV system using SPWM technique

Design and Analysis of Highly Efficient and Reliable Single-Phase Transformerless Inverter for PV Systems

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Ch.8 INVERTER. 8.1 Introduction. 8.2 The Full-Bridge Converter. 8.3 The Square-Wave Inverter. 8.4 Fourier Series Analysis

IEEE Transactions On Circuits And Systems Ii: Express Briefs, 2007, v. 54 n. 12, p

Jawad Ali, Muhammad Iftikhar Khan, Khadim Ullah Jan

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

Photovoltaic Grid-Connected System Based On Cascaded Quasi-Z-Source Network

Single-Phase Transformer less Inverter with High- Efficiency

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

A Five-Level Single-Phase Grid-Connected Converter for Renewable Distributed Systems

A Single Phase Multistring Seven Level Inverter for Grid Connected PV System

Design and Implementation of Quasi-Z-Source Inverter for Off-grid Photovoltaic Systems

ELIMINATION OF LEAKAGE CURRENT IN SINGLE PHASE GRID TIED INVERTER WITH PN-NPC TOPOLOGY

Photovoltaic Based Single Phase Grid Connected Transformer Less Inverter

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

PERFORMANCE ANALYSIS OF SEVEN LEVEL INVERTER WITH SOFT SWITCHING CONVERTER FOR PHOTOVOLTAIC SYSTEM

Multilevel Current Source Inverter Based on Inductor Cell Topology

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Voltage Unbalance Elimination in Multilevel Inverter using Coupled Inductor and Feedback Control

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

SVPWM Technique for Cuk Converter

Electromagnetic Compatibility and Better Harmonic Performance with Seven Level CHB Converter Based PV-Battery Hybrid System

@IJMTER-2016, All rights Reserved 241

Energetic PV Cell Based Power Supply Management Using Modified Quasi-Z-Source Inverter

A Dual Half-bridge Resonant DC-DC Converter for Bi-directional Power Conversion

Harmonic Reduction in Induction Motor: Multilevel Inverter

Investigation of Sst Pwm in qzsi

Harmonic Analysis Of Three Phase Diode Clamped Multilevel Inverters

Levels of Inverter by Using Solar Array Generation System

SINGLE PHASE MULTI STRING FIVE LEVEL INVERTER FOR DISTRIBUTED ENERGY SOURCES

Design and Simulation of High Frequency Inverter for PV System

FPGA based Transformer less grid connected inverter using boost converter for Photo voltaic applications

H6-TYPE IGBT CONFIGURATION FOR SINGLE PHASE GRID CONNECTED TRANSFORMERLESS PHOTOVOLTAIC APPLICATIONS

Analysis of Leakage Current and DC Injection in Transformerless PV Inverter Topologies

Bidirectional Ac/Dc Converter with Reduced Switching Losses using Feed Forward Control

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

HARMONIC ANALYSIS OF GRID CONNECTED PHOTOVOLTAIC INVERTER

REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL

Fuzzy Controlled Capacitor Voltage Balancing Control for a Three Level Boost Converter

NPC FULL-BRIDGE TOPOLOGIES FOR TRANSFORMERLESS PHOTOVOLTAIC GRID-TIED INVERTERS WITH AN LPF

Inverter topologies for photovoltaic modules with p-sim software

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 11 Issue 1 NOVEMBER 2014.

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Analysis and Modeling of Transformerless Photovoltaic Inverter Systems

A Solar Powered Water Pumping System with Efficient Storage and Energy Management

A Modified Single-Phase Quasi z source converter

THREE PHASE INVERTER USING COUPLED INDUCTOR FOR GRID CONNECTED PHOTOVOLTAIC SYSTEM

Bearing Currents and Shaft Voltage Reduction in Dual-Inverter-Fed Open-End Winding Induction Motor With CMV PWM Methods Employing PID

Improved Power Quality Bridgeless Isolated Cuk Converter Fed BLDC Motor Drive

International Journal Of Global Innovations -Vol.6, Issue.II Paper Id: SP-V6-I2-P05 ISSN Online:

Multilevel inverter with cuk converter for grid connected solar PV system

Simulation of Single Phase Grid Connected Photo Voltaic System Based On PWM Control Of Switched Boost Inverter For DC Nanogrid Applications

Single-Carrier Modulation for 9-Level Neutral Point Clamped Inverters in Three Phase Transformerless Photovoltaic Systems

Hybrid Full-Bridge Half-Bridge Converter with Stability Network and Dual Outputs in Series

A Transformerless Grid-Connected Photovoltaic System Based on the Coupled Inductor Single-Stage Boost Single-Phase Inverter

Implementation of Single Stage Three Level Power Factor Correction AC-DC Converter with Phase Shift Modulation

RECENTLY, the harmonics current in a power grid can

PERFORMANCE ANALYSIS OF SOLAR POWER GENERATION SYSTEM WITH A SEVEN-LEVEL INVERTER SUDHEER KUMAR Y, PG STUDENT CHANDRA KIRAN S, ASSISTANT PROFESSOR

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

INTERNATIO NAL JOURNAL O F MERGING TECHNOLOGY AND ADVANCED RESEARCH IN COMPUTING

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

Space Vecor Modulated Three Level Neutral Point Clamped Inverter Using A Single Z Source Network

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

CASCADED H-BRIDGE THREE-PHASE MULTILEVEL INVERTERS CONTROLLED BY MULTI-CARRIER SPWM DEDICATED TO PV

Modelling of Five-Level Inverter for Renewable Power Source

Assessment and Evaluation of Single Phase Grid Linked Transformer less Inverter with PV Input

REDUCTION OF COMMON MODE VOLTAGE IN THREE PHASE GRID CONNECTED CONVERTERS THROUGH NOVEL PWM TECHNIQUES

ADVANCES in NATURAL and APPLIED SCIENCES

Comparison Of DC-DC Boost Converters Using SIMULINK

A NOVEL High Step-Up Converter with a Voltage Multiplier Module for a Photo Voltaic System

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

BIDIRECTIONAL SOFT-SWITCHING SERIES AC-LINK INVERTER WITH PI CONTROLLER

Transcription:

High Efficiency Transformer less Inverter for Single-Phase Photovoltaic Systems using Switching Converter 1 M.Kannan, 2 G.Neelakrishnan, 3 S.Selvaraju, 4 D.Kalidass, 5 Andril Alagusabai, K.Vijayraj 6 Abstract There is a strong trend in the photovoltaic inverter technology to use transformer less topologies in order to acquire higher efficiencies combining with very low ground leakage current. When no transformer is used in a grid/load connected photovoltaic (PV) system, a galvanic connection between the grid and the PV array exists. In these conditions, dangerous leakage currents (common-mode currents) can appear through the stray capacitance between the PV array and the ground. In order to avoid these leakage currents, different inverter topologies that generate no varying common-mode voltages, such as the half-bridge and the bipolar pulse width modulation (PWM) full-bridge topologies, have been proposed. The need of a high-input voltage represents an important drawback of the half-bridge. The bipolar PWM full bridge requires a lower input voltage but exhibits a low efficiency. This paper proposes a new topology with eight switches and two diodes that generates no varying common-mode voltage and exhibits high efficiency. Index Terms About four key words or phrases in alphabetical order, separated by commas. I. INTRODUCTION The importance of renewable energy sources is recognized by both the general public and the power industries. Some researchers believe the concern for environmental damage is now an even greater priority than the need to preserve the finite natural resources for future generations. PHOTOVOLTAIC (PV) inverters become more and more widespread within both private and commercial circles. These grid/load-connected inverters convert the available direct current supplied by the PV panels and feed it into the utility grid/load. There are two main topology groups used in the case of grid/load-connected PV systems, namely, with and without galvanic isolation. Galvanic isolation can be on the dc side in the form of a high-frequency dc dc transformer or on the grid/load side in the form of a big bulky ac transformer. Both of these solutions offer the safety and advantage of galvanic isolation, but the efficiency of the whole system is decreased due to power Losses in these extra components. An improvement in inverter efficiency and a reduction in cost have been achieved by omitting the 50 Hz power transformer (transformer less) and by optimizing the Inverter current control strategies. The inverter described in this project is specifically for grid/load-connected PV Systems, it can be used for other traditional applications such as in uninterruptible Power supplies (UPS), motor controls and voltage regulation systems. The main aim of this project was to develop a new design procedure for a single-phase, transformer less PV inverter system suitable for grid/load connection, which would lead to higher inverter efficiencies, improved output power quality and reduced cost. Detailed performance analyses of both the unipolar and the bipolar switched inverters will be carried out before a final choice is made. Techniques to remove DC offset current will be investigated to ensure that the DC current injected into the grid/load system is maintained within the legal limits irrespective of its source. To improve the quality of inverter output current, a suitable efficient and cost effective ripple current filter design will also be developed. The specific objectives of the project are summarized High efficiency Constant High Frequency Common Mode Voltage Very Small Leakage Current Low Total Harmonic Distortion Inverter or power inverter is a device that converts the DC sources to AC sources. Inverters are used in a wide range of applications, from small switched power supplies for a computer to large electric utility applications to transport bulk power. This makes them very suitable for when you need to use AC power tools or appliances Control of the switches for the sinusoidal PWM output requires a reference signal (modulating or control signal) which is a sinusoidal wave and a carrier signal which a triangular wave that control the switching frequency. The benefit of choosing the PWM over analog control is increased noise immunity which the PWM is sometimes used for communication. Switching from an analog signal to PWM can increase the length of a communications channel dramatically. At the receiving end, a suitable RC (resistor-capacitor) or LC (inductor capacitor) network can remove the modulating high frequency square wave and return the signal to analog form. So, the filter requirement can be reduced and the overall inverter size can be reduced. II. PROPOSED TOPOLOGY A. Proposed Circuit Diagram Transformer less inverters with the single-phase bridge, using the pulse width modulation (PWM) scheme, the 894

electronic switches can be switched using either the bipolar or the unipolar mode. In the bipolar mode, the diagonally opposite switches of the two legs of the inverter bridge are switched as pairs. In the unipolar mode, the two legs of the bridge are not switched simultaneously but are controlled separately. In the unipolar mode, the output voltage swing is half of that in the bipolar mode for the same input DC voltage. Bipolar PWM generates a constant common-mode voltage. But, by using unipolar PWM modulation, the output of the converter will have three levels, but in this case, the generated common-mode voltage will have high-frequency components, which will lead to very high ground leakage currents. To reduce the losses, cost and size of the inverter system, it was decided not to use current loop configurations in which a power transformer is essential. Other types of inverters such as single-phase half bridge inverters with two capacitors connected across the input DC source were considered not suitable. Without the use of a step-up transformer, Half-bridge would need to be supplied with twice the DC voltage from the boost converter compared to the full bridge configuration. This method was therefore considered unsuitable and hence, the Single-phase full bridge inverter was chosen. The full-bridge inverter is a single stage dc ac conversion topology that is used quite often in PV inverters. By using bipolar PWM in the proposed topology, there is a constant common mode voltage which leads to very small leakage current. Figure.2 Positive Half Cycle: Active Vector In this situation, when S 5 and S 6 are on, V AB = V PV and the inductor current, which flows through, S 5, S 1, S 2 & S 6 and increases. The common-mode voltage is V cm = (V AO +V BO )/2 = (V PV +0)/2 = V PV /2 C. Positive Half Cycle: Zero Vectors As shown in figure.3.when S 5 and S 6 are turned off and S 3 and S 4 are turned on, the current splits into three paths: S 2 and the freewheeling diode of S 4, the freewheeling diode of S 3 and S 1 and S 8 and the freewheeling diode of S 7. Thus, S 4 and S 3 are turned on with no current and therefore no switching losses appear. The authors of the accepted manuscripts will be given a copyright form and the form should accompany your final submission. Figure.1. Proposed Circuit Diagram As shown in figure.1 the proposed circuit diagram, which consists of eight switches and two diodes. In this topology, diodes D 7 & D 8 and the capacitive divisor limit the blocking voltage of S 5 & S 6 and to half of the input voltage V pv. B. Positive Half Cycle: Active Vector As shown in figure.2 in the positive half cycle, S 1 & S 2 are on. In order to modulate the input voltage, S 5 and S 6 commutate at the switching frequency with the same commutation orders.s 3 and S 4 commute at the switching frequency together and complementarily to S 5 and S 6. Figure.3. Positive Half Cycle: Zero Vectors In this situation, voltages V AB and V CD tend to zero and diodes D 7 & D 8 fix the voltages V AO and V BO to V PV /2. Since V AB is clamped to zero the current decreases. Now, the common-mode voltage is V AO = V BO = V PV /2 = V cm = V PV /2 D. Negative Half Cycle: Active Vector As shown in figure 4 in the negative half cycle, S 3 and S 4 are on. Figure.4. Negative Half Cycle: Active Vector 895

Again, S 5 and S 6 commutate at the switching frequency in order to modulate the input voltage. S 1 and S 2 commute at the switching frequency together and complementarily to S 5 and S 6. In this situation, when S 5 and S 6 are on, V AB equals -V PV, and the inductor current, which now flows through, S 5, S 3, S 4 and S 6, decreases. The common-mode voltage is V cm = (V AO +V BO )/2= (0+V PV )/2=V PV /2 E. Negative Half Cycle: Zero Vectors It consists of single phase full bridge inverter with four switches, two bidirectional switches at the output of inverter, two switches and two diodes at the input side. Two diodes and capacitive divisor limit the blocking voltages of two switches at the input side. The input was dc source and the output has two resistive loads and there is a filter element between the bidirectional switches and output. As shown in figure 5 when S 5 and S 6 are turned off and S 1 and S 2 are turned on, the current splits into three paths. The first path consists of S 4 and the freewheeling diode of S 2, and the second of freewheeling diode of S 1 and S 3 and S 7 and the freewheeling diode of S 8. Figure.5 Negative Half Cycle: Zero Vectors Then Consequently, S 1 and S 2 are turned on with no current, so no switching losses appear. In this situation, voltages V AB and V CD tend to zero and diodes D 7 & D 8 fix the voltages and to V AO and V BO to V PV /2. The current decreases because V AB is clamped to zero. Now, the common-mode voltage V AO =V BO =V PV /2=V cm =V PV /2 III. SIMULATION Simulated diagram of Proposed Transformer Less HERIC is shown in figure 6, where PWM technique applied for this topology is bipolar switching. Figure.7 Simulated Output Voltage Figure.7 shows the simulated output voltage, which is measured across the output of two resistive loads by connecting a voltage measurement with scope. Figure.8 Simulated Load Current Figure.8 shows the simulated Load Current, which is the output inductance in series connection. Figure.6 Simulation Diagram of Proposed Transformer Less HERIC Figure.9 Simulated High Frequency Common Mode Voltage Figure.9 shows the simulated High Frequency Common Mode Voltage, which is measured by connecting two voltage measurements with scope between the output of first leg 896

inverter A and negative terminal O in one measurement and in another measurement between the output of second leg inverter B and negative terminal O. The measured voltage is half of the input voltage and constant. So the leakage current is very small and also there is no small pulse in the voltages compared to conventional topology with bipolar switching. Figure.12 shows the simulated diagram of closed loop of Proposed Transformer Less HERIC, where PWM technique applied for this topology is bipolar switching. By using the closed loop, if there is change in input voltage between 250-350v, the output voltage is 220v with +2%. Figure.10 Simulated Leakage Current Figure.10 shows the simulated Leakage Current, which is the mid-point of two output resistances and ground. Figure.13 Simulated Output Voltage Figure.13 shows the simulated output voltage, which is measured across the output of two resistive loads by connecting a voltage measurement with scope. Figure.11 Fast Fourier Transform Analysis Figure.14 Simulated Load Current Figure.14 shows the simulated Load Current, which is the output inductance in series connection. Figure.12 Simulation Diagram of Closed Loop of Proposed Transformer Less Heric Figure.15 Simulated High Frequency Common Mode Voltage 897

Figure.15 shows the simulated High Frequency Common Mode Voltage, which is measured by connecting two voltage measurements with scope between the output of first leg inverter A and negative terminal O in one measurement and in another measurement between the output of second leg inverter B and negative terminal O. The measured voltage is half of the input voltage and constant. So the leakage current is also very small. sources:note that the journal t, IEEE Trans. Ind. Electron., vol. 53, no. 4, pp. 1002 1016. [6] Gonzalez.R, Gubia.E, Lopez.J and Marroyo.L, (Jul. 2008) Transformer less single-phase multilevel-based photovoltaic inverter, IEEE Trans. Ind. Electron., vol. 55, no. 7, pp. 2694 2702. [7] Kerekes.T, Teodorescu.R, and Liserre.M, (Jun. 29 Jul. 1, 2008), Common-mode voltage in case of transformer less PV inverters connected to the grid, in Proc. ISIE, pp. 2390 2395. M.Kannan Assistant Professor (EEE), Muthayammal college of Engineering, completed post graduation in Sri Lakshmi Ammal Engineering College after completion of under graduation from Madha Engineering College, possessing membership in Indian Society For Technical Education. G.Neelakrishnan. Assistant Professor (EEE), Muthayammal college of Engineering, completed post graduation and under graduation Muthayammal Engineering College. Figure.16 Simulated Leakage Current Figure.16 shows the simulated Leakage Current, which is the mid-point of two output resistances and ground. IV. CONCLUSION Transformer less inverters offers a better efficiency, compared to those inverters that have a galvanic isolation. On the other hand, in case the transformer is omitted, the generated common-mode behavior of the inverter topology greatly influences the ground leakage current through the parasitic capacitance of the PV. This project proposes a new transformer less, single-phase PV inverter with eight switches and two diodes. The proposed topology generates constant common-mode voltage, exhibits a high efficiency and this topology can be an advantageous power-conversion stage for transformer less, grid/load-connected PV systems. In future the prototype model of a proposed transformer less HERIC is implemented in hardware and the results are analyzed.. REFERENCES [1 ] Kerekes.T, Teodorescu.R, and Borup.U, (Mar 1, 2007) Transformer less photovoltaic inverters connected to the grid, Proc. APEC, Feb. 25, pp. 1733 1737. [2] Sahan.B, Vergara.A.N, Henze.N, Engler.A, and Zacharias.P, (Jul. 2008) A single stage PV module integrated converter based on a low-power current source inverter, IEEE Trans. Ind. Electron., vol. 55, no. 7, pp. 2602 2609. [3] Selvaraj.J and Rahim.N.A, (Jan. 2009) Multilevel inverter for grid-connected PV system employing digital PI controller, IEEE Trans. Ind. Electron., vol. 56, no. 1, pp. 149 158. [4] Gonzalez.R, Gubia.E, Lopez.J and Marroyo.L, (Jul. 2008) Transformer less single-phase multilevel-based photovoltaic inverter, IEEE Trans. Ind. Electron., vol. 55, no. 7, pp. 2694 2702. [5]Carrasco.J.M., Franquelo.L.G, Bialasiewicz.J.T, Galvan.E, Guisado.R.C.P, Prats.M.A.M, Leon.J.I, and Moreno-Alfonso.N., (2008) Power-electronic systems for the grid integration of renewable energy S.Selvaraju has obtained his B.E Electronics and communication engineering in Anand Institute of higher techonology then obtained his M.Tech in Communication Systems at SRM university. Currently he is working as a Assistant Professor in Muthyammal college of engineering in ECE department.he has Published two national conference and one international conference.he has published two international journals in IJERT and IOSR.Currently he is an international active member in IAENG and UACEE.His area of interest is Image processing and wireless network D.Kallidass Assistant Professor (EEE), Muthayammal college of Engineering, completed post graduation in Govt. college of Engineering after completion of under graduation from Muthayammal Engineering College, possessing membership in Indian Society For Technical Education. Andril Alagusabai Assistant Professor (EEE), Muthayammal college of Engineering, completed post graduation in College of Engineering Guindy 898

Anna University after completion of under graduation from Sona College Of Technology. Mr.K.Vijayraj has obtained his B.E Electrical and electronics engineering degree in Saranathan college of engineering then obtained his M.E Applied Electronics engineering degree at Adithya institute of techonology.currently he is working as a Assistant Professor in Muthyammal college of engineering in ECE department.he has two years industrial experience in WTI Advanced techonology(subsidiary of TATA Consultancy Service) as a GIS TECHNICIAN and as a Junior Electrical engineer in KIRUTHIKA ELECTRIC CO. He has published four national conferences and two international conferences. He has published two international journals in IJERT and IOSR. Currently he is an international active member in IAENG and UACEE. His area of interest is Image Processing and Power Electronics. 899