Union County Vocational - Technical Schools Scotch Plains, New Jersey

Similar documents
A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel and iron.

EXTERIOR PAINTING

A. Section includes surface preparation and the application of paint systems on exterior substrates.

B. Samples: For each exposed product and for each color and texture specified.

B. Samples for Verification: For each type of paint system and each color and gloss of topcoat.

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel.

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB

A. This Section includes surface preparation and the application of paint systems on the following substrates:

SECTION EXTERIOR PAINTING PART 1 - GENERAL

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

A. This Section includes surface preparation and field painting of exposed interior items and surfaces.

SECTION INTERIOR PAINTING

1. Labels: Do not paint over UL, FMG, or other code-required labels or equipment name, identification, performance rating, or nomenclature plates.

Copyright 2004 AIA MASTERSPEC 02/04 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CORONADO PAINT COMPANY

October 30, Addendum # 1 IFB # District-Wide Painting Services (Interior & Exterior)

SECTION PAINTING

DUNN-EDWARDS INTERIOR MASTER HEALTCHARE SPECIFICATION SECTION INTERIOR PAINTING (HEALTHCARE)

State College of Florida Building 11_Music Interior Painting

A: Proposed Scope of Services. B: Site Location Map. C: Selected existing conditions photographs.

PAINTING PAINTING

SECTION PAINTING

SECTION PAINTS AND COATINGS. a. Section Submittal Procedures: Requirements for submittals.

SECTION PAINTS AND COATINGS

HANDLING INSTRUCTIONS:

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION. SPECIFICATIONS FOR Interior Painting CONTRACT

MISSOURI ARMY NATIONAL GUARD MISCELLANEOUS INTERIOR AND EXTERIOR REPAIRS CARTHAGE, MO T SECTION PAINTING PAINTING

SECTION METAL FABRICATIONS

SECTION 025 INDUSTRIAL PAINTING

Construction Standards PAGE

SECTION PAINTING (PROFESSIONAL LINE PRODUCTS) PART 1 - GENERAL 1.1 SUMMARY

DUNN-EDWARDS INTERIOR MASTER SPECIFICATION

SECTION PAINTING 1.4 QUALITY ASSURANCE 1.1 SUMMARY 1.5 DELIVERY, STORAGE AND HANDLING 1.2 REFERENCES 1.6 PROJECT CONDITIONS OR SITE CONDITIONS

DULUX UNIVERSAL UNDERCOAT

Copyright 2011 AIA MASTERSPEC Full Length 02/11 PRODUCT MASTERSPEC LICENSED BY ARCOM TO DUNN-EDWARDS CORPORATION.

A. This Section includes surface preparation and field painting of exposed exterior and interior items and surfaces.

Dunn- Edwards Exterior Master Specification

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION PAINTS AND COATINGS PART 1 GENERAL

Ash Brook Golf Course Scotch Plains, New Jersey

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

A. This Section includes surface preparation and field painting of the following:

Design and Construction Standards SECTION ATHLETIC LOCKERS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

Copyright 2011 AIA MASTERSPEC Full Length 02/11 PRODUCT MASTERSPEC LICENSED BY ARCOM TO DUNN-EDWARDS CORPORATION.

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION BULLET- RESISTANT DOORS

AESS Documents prepared by CISC ad hoc committee

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

A. Provide all finish carpentry needed for a complete and proper installation.

.3 Comply with the requirements of the Manitoba Occupational Health and Safety Act and Regulations for Construction Projects.

PRODUCT DESCRIPTION High quality interior or exterior enamel for surfaces where a glossy durable finish is required

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

REQUEST FOR PROPOSALS

RAPTOR EPOXY PRIMER RAPTOR 4:1 ANTI-CORROSIVE EPOXY PRIMER DESCRIPTION

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

WHAT S ON THE MARKET?

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT


SECTION FINISH CARPENTRY

Nations Ford Elementary Replacement School for the Charlotte-Mecklenburg Board of Education WHN Architects # 14139

Get the benefits of oil with the ease of latex

SECTION INTERIOR FINISH CARPENTRY

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

135 North South Street

#85-2-5A: PAINT STRIPPING AND FINISH ANALYSIS AND CORRECTION - (Aug 7, 1985)

PAINTING OF UNPAINTED SURFACES

SECTION WOOD DOORS

Toll-Free

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION HOLLOW METAL DOORS AND FRAMES

UNIT 11: PAINTING, STAINING, AND FINISHING

May 11, Prairie Valley School Division No. 208 (PVSD) Summer 2017 Paint Program

For proudly getting the best finish

Technical Data Sheet. Magnetic glass fabric. Properties / Usage. Technical Parameters / Roll Style. Substrate preparation

Bid No :01 Exterior Roynon Elementary & La Verne Heights (Alternate #1) SCOPE OF WORK

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

SUNBELT transformer WIDTFA3501 PAINTING TRANSFORMERS WITH WATERBORNE PAINT SYSTEMS INTERNAL USE ONLY DOCUMENT HISTORY

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

OSE Submittal July 20, 2018

Installing 3M DI-NOC Architectural Finishes on Doors

SECTION PRE-MANUFACTURED CABINETS

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

SECTION WOOD ARCHITECTURAL CABINETS AND QUARTZ COUNTERTOPS

VERTICAL STILE ABOVE HORIZONTAL TRIM VERTICAL STILE BELOW COVE BASE ADHESIVE. 1" [25.4mm] BASE DETAIL

Agenda. Interior Painting Exterior Painting Typical Problems Low VOC Paints

Construction Standards PAGE

SECTION ARCHITECTURAL WOOD CASEWORK

SECTION CABLE TRAYS

March 2009 Product Information RAPID GREYMATIC 2K Filler

Interior. How to paint

Safety First! Review the Safety Checklist before performing tasks in this chapter.

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

Architecturally Exposed Structural Steelwork (AESS) Sample Specification (for Engineers)

SECTION ARCHITECTURAL WOODWORK

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

High-quality, water-dilutable satin gloss enamel on the basis of a modified alkyd technology.

REFINISH APPLICATION Course Syllabus

Transcription:

SECTION 099123 - INTERIOR PAINTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Steel. 2. Wood. 3. Gypsum board. B. Related Sections: 1. Division 05 Sections for shop priming of metal substrates with primers specified in this Section. 2. Division 08 Sections for factory priming doors with primers specified in this Section. 1.3 DEFINITIONS A. Gloss Level 1: Not more than 5 units at 60 degrees and 10 units at 85 degrees, according to ASTM D 523. B. Gloss Level 2: Not more than 10 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTM D 523. C. Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees, according to ASTM D 523. D. Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D 523. 1.4 ACTION SUBMITTALS A. Product Data: For each type of product. Include preparation requirements and application instructions. B. Samples for Initial Selection: For each type of topcoat product. 1.5 DELIVERY, STORAGE, AND HANDLING A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 deg F. 1. Maintain containers in clean condition, free of foreign materials and residue. 2. Remove rags and waste from storage areas daily. INTERIOR PAINTING 099123-1

1.6 FIELD CONDITIONS A. Apply paints only when temperature of surfaces to be painted and ambient air temperatures are between 50 and 95 deg F. B. Do not apply paints when relative humidity exceeds 85 percent; at temperatures less than 5 deg F above the dew point; or to damp or wet surfaces. PART 2 - PRODUCTS 2.1 PAINT, GENERAL A. MPI Standards: Provide products that comply with MPI standards indicated and that are listed in its "MPI Approved Products List." B. Material Compatibility: 1. Provide materials for use within each paint system that are compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience. 2. For each coat in a paint system, provide products recommended in writing by manufacturers of topcoat for use in paint system and on substrate indicated. 2.2 PRIMERS/SEALERS A. Primer Sealer, Latex, Interior: MPI #50. 2. Environmental Performance Rating: EPR 3. B. Primer Sealer, Latex, Interior, Wood: MPI #39. 1. VOC Content: E Range of E. 2. Environmental Performance Rating: EPR 3. 2.3 WATER-BASED PAINTS A. Latex, Interior, Flat, (Gloss Level 1): MPI #53. B. Latex, Interior, Low Sheen, (Gloss Level 2): MPI #44. C. Latex, Interior, Eggshell (Gloss Level 3): MPI #52. INTERIOR PAINTING 099123-2

D. Latex, Interior, Semi-Gloss, (Gloss Level 5): MPI #54. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work. B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows: 1. Wood: 15 percent. 2. Gypsum Board: 12 percent. C. Gypsum Board Substrates: Verify that finishing compound is sanded smooth. D. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers. E. Proceed with coating application only after unsatisfactory conditions have been corrected. 1. Application of coating indicates acceptance of surfaces and conditions. 3.2 PREPARATION A. Comply with manufacturer's written instructions and recommendations in "MPI Manual" applicable to substrates indicated. B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surfaceapplied protection before surface preparation and painting. 1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection if any. C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease, and incompatible paints and encapsulants. 1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce paint systems indicated. D. Steel Substrates: Remove rust, loose mill scale, and shop primer, if any. Clean using methods recommended in writing by paint manufacturer. 1. SSPC-SP 2, "Hand Tool Cleaning." 2. SSPC-SP 3, "Power Tool Cleaning." INTERIOR PAINTING 099123-3

E. Shop-Primed Steel Substrates: Clean field welds, bolted connections, and abraded areas of shop paint, and paint exposed areas with the same material as used for shop priming to comply with SSPC-PA 1 for touching up shop-primed surfaces. F. Wood Substrates: 1. Sand surfaces that will be exposed to view, and dust off. 2. Prime edges, ends, faces, undersides, and backsides of wood. 3. After priming, fill holes and imperfections in the finish surfaces with putty or plastic wood filler. Sand smooth when dried. 3.3 APPLICATION A. Apply paints according to manufacturer's written instructions and to recommendations in "MPI Manual." 1. Use applicators and techniques suited for paint and substrate indicated. 2. Paint surfaces behind movable equipment and furniture same as similar exposed surfaces. Before final installation, paint surfaces behind permanently fixed equipment or furniture with prime coat only. 3. Paint front and backsides of access panels, removable or hinged covers, and similar hinged items to match exposed surfaces. 4. Do not paint over labels of independent testing agencies or equipment name, identification, performance rating, or nomenclature plates. 5. Primers specified in painting schedules may be omitted on items that are factory primed or factory finished if acceptable to topcoat manufacturers. B. Tint each undercoat a lighter shade to facilitate identification of each coat if multiple coats of same material are to be applied. Tint undercoats to match color of topcoat, but provide sufficient difference in shade of undercoats to distinguish each separate coat. C. If undercoats or other conditions show through topcoat, apply additional coats until cured film has a uniform paint finish, color, and appearance. D. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks. E. Painting Fire Suppression, Plumbing, HVAC, Electrical, Communication, and Electronic Safety and Security Work: 1. Paint the following work where exposed in equipment rooms: a. Equipment, including panelboards. 2. Paint portions of internal surfaces of metal ducts, without liner, behind air inlets and outlets that are visible from occupied spaces. 3.4 CLEANING AND PROTECTION A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from Project site. INTERIOR PAINTING 099123-4

B. After completing paint application, clean spattered surfaces. Remove spattered paints by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces. C. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition. D. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces. 3.5 INTERIOR PAINTING SCHEDULE A. Concrete Substrates, Floor: 1. Epoxy Floor System: B. Steel Substrates: a. Prime Coat: Floor paint, water-based epoxy, gloss (maximum Gloss Level 4). b. Intermediate and Topcoat: Floor paint, epoxy, gloss (maximum Gloss Level 4). 1. Shop Primed Ferrous Metal: products as recommended by manufacturer of doors and frames: a. Intermediate Coat: Institutional low-odor/voc interior latex matching topcoat. b. Topcoat: Institutional low-odor/voc interior latex. C. Gypsum Board Substrates: MPI INT 9.2M. 1. Latex System: a. Prime Coat: Primer sealer, latex, interior, MPI #50. b. Intermediate Coat: Latex, interior, matching topcoat. c. Topcoat: Latex, interior, flat, (Gloss Level 1), MPI #53 (ceilings). d. Topcoat: Latex, interior, (Gloss Level 3), MPI #52 (walls). D. Wood Substrates: MPI INT 6.3V. 1. Latex System: a. Prime Coat: Interior latex-based wood primer. b. Intermediate Coat: Latex, interior, matching topcoat. c. Topcoat: Latex, interior, (Gloss Level 3), MPI #52 (walls). END OF SECTION 099123 INTERIOR PAINTING 099123-5